• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

"Influência do método de remoção de cárie na resistência adesiva de um sistema autocondicionante" / Microtensile bond strength of self-etching adhesives to caries-affected dentine

Tachibana, Arlene 10 June 2005 (has links)
Novos métodos de remoção do tecido cariado tem sido propostos, entre eles a utilização de lasers, abrasão a ar e químico-mecânico. Este trabalho teve o objetivo de avaliar a influência de diferentes métodos de remoção de cárie na resistência de união de um sistema adesivo autocondicionante. Cinquenta molares humanos cariados extraídos foram desgastados para expor uma superfície plana onde a lesão de cárie se encontrava rodeada por dentina hígida. Os dentes foram divididos em 05 grupos (n=10), com um total de 50 dados, de acordo com o método de remoção do tecido cariado, como segue: G1 - sem remoção; G2 - remoção com lixa; G3 – broca de aço esférica em baixa rotação; G4 - laser de Er, Cr: YSGG e G5 - Carisolv. Procedimentos adesivos foram realizados com o sistema autocondicionante (Clearfil SE Bond – Kuraray – Japão), de acordo com as instruções do fabricante. Um cilíndro de resina composta (Z250- 3M do Brasil) foi construído sobre a superfície com o sistema adesivo e estocados em água (24 horas a 37 0 C). Os corpos de prova foram seccionados verticalmente para obtenção de fatias e em seguida confeccionadas ampulhetas em dentina infectada, afetada e sadia, com área aproximada de 1mm 2. As ampulhetas foram montadas em dispositivos de micro-tração e ensaiados na máquina de teste (Mini-Instron) com velocidade de 0,5mm/min. Os resultados obtidos mostraram que existem diferenças estatisticamente significantes entre os substratos sadio e infectado para o grupo G1e sadio e afetado para os grupos G2, G3 e G5. Em dentina sadia, o método utilizado em G3 resultou em valores de adesão superiores com relação a G4 e G2 foi estatisticamente superior com relação a todos os grupos. Os métodos de remoção de dentina infectada utilizados em G2 e G3 resultaram em valores de adesão superiores com relação a G1(dentina infectada). Desta forma podemos concluir que: o tipo de substrato influencia significativamente na resistência adesiva do sistema autocondicionante testado. A adesão à dentina sadia é mais efetiva que à dentina infectada (G1) e à dentina afetada obtida após remoção do tecido infectado com lixa (G2), broca (G3) e Carisolv (G5). Entretanto, para o laser de Er,Cr:YSGG (G4) não houve evidência amostral que sugerisse maior efetividade na adesão da dentina sadia com relação à dentina afetada. A adesão em dentina sadia mostrou-se mais efetiva quando esta foi instrumentada com lixa. Porém, trata-se de um recurso laboratorial de padronização dos espécimes. A utilização da broca de aço resultou em uma superfície mais favorável a adesão, quando comparada à obtida após irradiação com laser de Er, Cr: YSGG, em dentina sadia. A adesão em dentina infectada é pobre, ficando ressaltada a necessidade da remoção deste tipo de dentina, preferencialmente com lixa ou broca, previamente a adesão com sistema autocondicionante. Para os demais métodos de remoção da dentina infectada testados, não houve evidência amostral para se detectar a existência de diferenças significantes na resistência adesiva em dentina afetada. / New methods for carious dentine removal have been proposed, such as, lasers and chemo-mechanical. This in vitro study aimed to evaluate the influence of caries removal methods (steel burs, Er, Cr: YSGG laser and Carisolv) on microtensile bond strength of self-etching adhesive systems. 50 extracted carious human molars were ground to expose flat surfaces where caries lesion was surrounded by normal dentine. Teeth were divided into 5 groups (n=10), with 50 original data, according to the removal method used: G1 - no removal; G2 - abrasive paper, G3 - steel burs; G4 – Er, Cr: YSGG laser (79, 61 J/cm 2 ) and G5 – Carisolv. Surfaces were bonded with Clearfil SE Bond, according to manufacturers’ instructions. A crown was built up using composite resin (Z250- 3M Brasil). After storage in water (24 h, 37 0 C), teeth were vertically serially sectioned into slices and trimmed into an hourglass shape with about of 1mm 2 area at the adhesion interface, that contained either infected, caries affected and normal dentine. Samples were tested in tension in a Instron machine at 0,5mm/min. Results showed that there is a significant difference between tested groups (p< 0.005). Significantly lower results were found for caries infected dentin when compared to normal dentin values (G1). A significant difference was also found when caries affected and normal dentin were compared (G2, G3, G5). In normal dentin, G2 showed better bond strenght than another groups and G4 showed lower results than G3. G2 and G3 caries infected dentin removal methods showed better bond strength than the other groups when compared with G1 (caries infected dentin). The results indicated that: bond strength of a self-etching system to normal dentin was better than to caries infected (G1) and caries affected dentin after the use of abrasive paper (G2), round steel bur (G3) and Carisolv (G4). However, there was no difference between caries affected and normal dentin after the use of ErCr:YSGG laser (G4); abrasive paper is a laboratorial method to create smear layer and it was responsable for the best bond strength to normal dentin. The usage of Er, Cr: YSGG laser negatively altered adhesion of self-etching system on normal dentin when compared with round steel bur; infected dentin is not an adequate substrate for adhesion. Abrasive paper and round steel bur are the best caries infected dentin removal methods. There were no difference in bond strength to caries affected dentin when the other methods were used.
2

"Influência do método de remoção de cárie na resistência adesiva de um sistema autocondicionante" / Microtensile bond strength of self-etching adhesives to caries-affected dentine

Arlene Tachibana 10 June 2005 (has links)
Novos métodos de remoção do tecido cariado tem sido propostos, entre eles a utilização de lasers, abrasão a ar e químico-mecânico. Este trabalho teve o objetivo de avaliar a influência de diferentes métodos de remoção de cárie na resistência de união de um sistema adesivo autocondicionante. Cinquenta molares humanos cariados extraídos foram desgastados para expor uma superfície plana onde a lesão de cárie se encontrava rodeada por dentina hígida. Os dentes foram divididos em 05 grupos (n=10), com um total de 50 dados, de acordo com o método de remoção do tecido cariado, como segue: G1 - sem remoção; G2 - remoção com lixa; G3 – broca de aço esférica em baixa rotação; G4 - laser de Er, Cr: YSGG e G5 - Carisolv. Procedimentos adesivos foram realizados com o sistema autocondicionante (Clearfil SE Bond – Kuraray – Japão), de acordo com as instruções do fabricante. Um cilíndro de resina composta (Z250- 3M do Brasil) foi construído sobre a superfície com o sistema adesivo e estocados em água (24 horas a 37 0 C). Os corpos de prova foram seccionados verticalmente para obtenção de fatias e em seguida confeccionadas ampulhetas em dentina infectada, afetada e sadia, com área aproximada de 1mm 2. As ampulhetas foram montadas em dispositivos de micro-tração e ensaiados na máquina de teste (Mini-Instron) com velocidade de 0,5mm/min. Os resultados obtidos mostraram que existem diferenças estatisticamente significantes entre os substratos sadio e infectado para o grupo G1e sadio e afetado para os grupos G2, G3 e G5. Em dentina sadia, o método utilizado em G3 resultou em valores de adesão superiores com relação a G4 e G2 foi estatisticamente superior com relação a todos os grupos. Os métodos de remoção de dentina infectada utilizados em G2 e G3 resultaram em valores de adesão superiores com relação a G1(dentina infectada). Desta forma podemos concluir que: o tipo de substrato influencia significativamente na resistência adesiva do sistema autocondicionante testado. A adesão à dentina sadia é mais efetiva que à dentina infectada (G1) e à dentina afetada obtida após remoção do tecido infectado com lixa (G2), broca (G3) e Carisolv (G5). Entretanto, para o laser de Er,Cr:YSGG (G4) não houve evidência amostral que sugerisse maior efetividade na adesão da dentina sadia com relação à dentina afetada. A adesão em dentina sadia mostrou-se mais efetiva quando esta foi instrumentada com lixa. Porém, trata-se de um recurso laboratorial de padronização dos espécimes. A utilização da broca de aço resultou em uma superfície mais favorável a adesão, quando comparada à obtida após irradiação com laser de Er, Cr: YSGG, em dentina sadia. A adesão em dentina infectada é pobre, ficando ressaltada a necessidade da remoção deste tipo de dentina, preferencialmente com lixa ou broca, previamente a adesão com sistema autocondicionante. Para os demais métodos de remoção da dentina infectada testados, não houve evidência amostral para se detectar a existência de diferenças significantes na resistência adesiva em dentina afetada. / New methods for carious dentine removal have been proposed, such as, lasers and chemo-mechanical. This in vitro study aimed to evaluate the influence of caries removal methods (steel burs, Er, Cr: YSGG laser and Carisolv) on microtensile bond strength of self-etching adhesive systems. 50 extracted carious human molars were ground to expose flat surfaces where caries lesion was surrounded by normal dentine. Teeth were divided into 5 groups (n=10), with 50 original data, according to the removal method used: G1 - no removal; G2 - abrasive paper, G3 - steel burs; G4 – Er, Cr: YSGG laser (79, 61 J/cm 2 ) and G5 – Carisolv. Surfaces were bonded with Clearfil SE Bond, according to manufacturers’ instructions. A crown was built up using composite resin (Z250- 3M Brasil). After storage in water (24 h, 37 0 C), teeth were vertically serially sectioned into slices and trimmed into an hourglass shape with about of 1mm 2 area at the adhesion interface, that contained either infected, caries affected and normal dentine. Samples were tested in tension in a Instron machine at 0,5mm/min. Results showed that there is a significant difference between tested groups (p< 0.005). Significantly lower results were found for caries infected dentin when compared to normal dentin values (G1). A significant difference was also found when caries affected and normal dentin were compared (G2, G3, G5). In normal dentin, G2 showed better bond strenght than another groups and G4 showed lower results than G3. G2 and G3 caries infected dentin removal methods showed better bond strength than the other groups when compared with G1 (caries infected dentin). The results indicated that: bond strength of a self-etching system to normal dentin was better than to caries infected (G1) and caries affected dentin after the use of abrasive paper (G2), round steel bur (G3) and Carisolv (G4). However, there was no difference between caries affected and normal dentin after the use of ErCr:YSGG laser (G4); abrasive paper is a laboratorial method to create smear layer and it was responsable for the best bond strength to normal dentin. The usage of Er, Cr: YSGG laser negatively altered adhesion of self-etching system on normal dentin when compared with round steel bur; infected dentin is not an adequate substrate for adhesion. Abrasive paper and round steel bur are the best caries infected dentin removal methods. There were no difference in bond strength to caries affected dentin when the other methods were used.
3

Influência da contaminação com sangue e de diferentes agentes de limpeza na adesão de um sistema autocondicionante aos tecidos dentais / Blood contamination and cleaning substances influence on adhesion

Tachibana, Arlene 04 August 2008 (has links)
A presença de lesões de cárie localizadas em áreas de difícil acesso para realização de isolamento absoluto torna a contaminação do campo operatório um fator de grande importância para o sucesso de uma restauração adesiva, apesar da grande variedade de sistemas adesivos de uso simplificado existentes atualmente no mercado odontológico. Os estudos que envolvem contaminação por sangue existentes na literatura expõem diferentes métodos de manipulação do contaminante, quanto a adição ou não de um anticoagulante bem como quanto a possibilidade de armazenamento deste. Este trabalho teve como objetivo avaliar, através do ensaio de microcisalhamento, a metodologia mais adequada para obtenção, manipulação do sangue e a eficiência de diferentes substâncias de uso corrente no consultório odontológico para remoção do contaminante de uma superfície dental. No experimento 1 deste trabalho, 6 dentes foram seccionados ao meio, no sentido do longo eixo e distribuídos em grupos, de acordo com o período de armazenamento do sangue heparinizado (0 hora, 24 horas, 7 dias) utilizado para contaminá-los previamente a aplicação do sistema adesivo autocondicionante de passo único (Clearfill S3 Bond). No expermiento 2, 18 dentes foram seccionados da mesma forma e distribuídos em grupos de acordo com o contaminante utilizado (ausência de contaminante, sangue fresco e sangue heparinizado-este utilizado pelo período máximo de tempo determinado pelo experimento anterior). No experimento 3 deste trabalho, 39 dentes foram seccionados e distribuídos em grupos de acordo com o agente de limpeza utilizado para remoção do contaminante (água oxigenada, Dakin e tergentol). Nesta fase foi avaliada a eficiência dos agentes de limpeza na restauração dos valores de adesão dos tecidos dentais aos valores obtidos em condições sem contaminação. Em todos os experimentos, inicialmente foram realizados os testes em esmalte e em seguida os dentes foram desgastados para realização dos testes em dentina, nas mesmas condições. Após a realização dos testes de microcisalhamento, observamos os tipos de fraturas ocorridas e as médias dos valores de resistência adesiva obtidos por cada metade de dente calculada. Os resultados obtidos nos permitiram concluir que o sangue heparinizado pode ser armazenado para posterior utilização por até 7 dias sem perder suas características de contaminante. A escolha relativa ao tipo de sangue que se deve utilizar - sangue fresco ou sangue heparinizado fica a critério do pesquisador e suas conveniências experimentais. Todas as substâncias testadas como agente de limpeza (líquido de Dakin, Tergentol e água oxigenada) na remoção do contaminante sobre esmalte e dentina foram eficientes para restabelecer os valores de resistência de união do sistema adesivo autocondicionante de passo único. Adicionalmente, a simples aplicação do jato de água sobre a superfície de esmalte e dentina contaminada é suficiente para a recuperação dos valores de resistência adesiva. / Although new self-etching adhesive systems provide a faster application due to a reduced number of components and application steps, the risk of contamination by oral fluids is not eliminated. Achieving good moisture control is a common problem in restorative dentistry. Blood contamination can occur especially when rubber dam isolation is not feasible, like carious lesions found near to gingival margin. To simulate gingival bleeding in laboratory study, some investigators have used freshly capillary blood, on the other hand other investigators have used venous blood sample with an anticoagulant. Among the studies that used venous blood with anticoagulant, some authors used this blood immediately after. However, other authors used the collected blood sample within one week. Based on this variety of blood manipulation, the aim of the present study was to investigate, in the first phase, the influence of storage period of the heparinized blood on microshear bond strength of a 1-step self-etching adhesive system to enamel and dentin. In second phase, the influence of heparinized venous blood vs. fresh capillary blood on microshear bond strength of a 1-step self-etching adhesive system to enamel and dentin was tested. In the third phase of this study the efficiency of different cleaning agents (Dakins solution, Tergentol and Hidrogen peroxide) on microshear bond strength of a 1-step self-etching adhesive system to enamel and dentin contaminated by blood was investigated. The results show that heparinized blood can be used to simulate gingival bleeding in laboratory study for up to 7 days without difference in its deleterious influence on adhesion tests. Contamination with fresh blood or heparinized blood resulted in lower values of adhesion, compared to enamel and dentin without contamination. All cleaning agents used in this study were efficient to recover the lost microshear bond strengths of blood contaminated enamel and dentin.
4

Influência da contaminação com sangue e de diferentes agentes de limpeza na adesão de um sistema autocondicionante aos tecidos dentais / Blood contamination and cleaning substances influence on adhesion

Arlene Tachibana 04 August 2008 (has links)
A presença de lesões de cárie localizadas em áreas de difícil acesso para realização de isolamento absoluto torna a contaminação do campo operatório um fator de grande importância para o sucesso de uma restauração adesiva, apesar da grande variedade de sistemas adesivos de uso simplificado existentes atualmente no mercado odontológico. Os estudos que envolvem contaminação por sangue existentes na literatura expõem diferentes métodos de manipulação do contaminante, quanto a adição ou não de um anticoagulante bem como quanto a possibilidade de armazenamento deste. Este trabalho teve como objetivo avaliar, através do ensaio de microcisalhamento, a metodologia mais adequada para obtenção, manipulação do sangue e a eficiência de diferentes substâncias de uso corrente no consultório odontológico para remoção do contaminante de uma superfície dental. No experimento 1 deste trabalho, 6 dentes foram seccionados ao meio, no sentido do longo eixo e distribuídos em grupos, de acordo com o período de armazenamento do sangue heparinizado (0 hora, 24 horas, 7 dias) utilizado para contaminá-los previamente a aplicação do sistema adesivo autocondicionante de passo único (Clearfill S3 Bond). No expermiento 2, 18 dentes foram seccionados da mesma forma e distribuídos em grupos de acordo com o contaminante utilizado (ausência de contaminante, sangue fresco e sangue heparinizado-este utilizado pelo período máximo de tempo determinado pelo experimento anterior). No experimento 3 deste trabalho, 39 dentes foram seccionados e distribuídos em grupos de acordo com o agente de limpeza utilizado para remoção do contaminante (água oxigenada, Dakin e tergentol). Nesta fase foi avaliada a eficiência dos agentes de limpeza na restauração dos valores de adesão dos tecidos dentais aos valores obtidos em condições sem contaminação. Em todos os experimentos, inicialmente foram realizados os testes em esmalte e em seguida os dentes foram desgastados para realização dos testes em dentina, nas mesmas condições. Após a realização dos testes de microcisalhamento, observamos os tipos de fraturas ocorridas e as médias dos valores de resistência adesiva obtidos por cada metade de dente calculada. Os resultados obtidos nos permitiram concluir que o sangue heparinizado pode ser armazenado para posterior utilização por até 7 dias sem perder suas características de contaminante. A escolha relativa ao tipo de sangue que se deve utilizar - sangue fresco ou sangue heparinizado fica a critério do pesquisador e suas conveniências experimentais. Todas as substâncias testadas como agente de limpeza (líquido de Dakin, Tergentol e água oxigenada) na remoção do contaminante sobre esmalte e dentina foram eficientes para restabelecer os valores de resistência de união do sistema adesivo autocondicionante de passo único. Adicionalmente, a simples aplicação do jato de água sobre a superfície de esmalte e dentina contaminada é suficiente para a recuperação dos valores de resistência adesiva. / Although new self-etching adhesive systems provide a faster application due to a reduced number of components and application steps, the risk of contamination by oral fluids is not eliminated. Achieving good moisture control is a common problem in restorative dentistry. Blood contamination can occur especially when rubber dam isolation is not feasible, like carious lesions found near to gingival margin. To simulate gingival bleeding in laboratory study, some investigators have used freshly capillary blood, on the other hand other investigators have used venous blood sample with an anticoagulant. Among the studies that used venous blood with anticoagulant, some authors used this blood immediately after. However, other authors used the collected blood sample within one week. Based on this variety of blood manipulation, the aim of the present study was to investigate, in the first phase, the influence of storage period of the heparinized blood on microshear bond strength of a 1-step self-etching adhesive system to enamel and dentin. In second phase, the influence of heparinized venous blood vs. fresh capillary blood on microshear bond strength of a 1-step self-etching adhesive system to enamel and dentin was tested. In the third phase of this study the efficiency of different cleaning agents (Dakins solution, Tergentol and Hidrogen peroxide) on microshear bond strength of a 1-step self-etching adhesive system to enamel and dentin contaminated by blood was investigated. The results show that heparinized blood can be used to simulate gingival bleeding in laboratory study for up to 7 days without difference in its deleterious influence on adhesion tests. Contamination with fresh blood or heparinized blood resulted in lower values of adhesion, compared to enamel and dentin without contamination. All cleaning agents used in this study were efficient to recover the lost microshear bond strengths of blood contaminated enamel and dentin.

Page generated in 0.0776 seconds