Spelling suggestions: "subject:"emiconductor detectors"" "subject:"emiconductor etectors""
1 |
A study of GaAs detectors for tracking in the ATLAS experimentManolopoulos, Spyros January 1996 (has links)
No description available.
|
2 |
Desenvolvimento do cristal semicondutor de iodeto de mercúrio para aplicação como detector de radiação / Development of the mercury iodine semiconductor crystal for application as a radiation detectorMARTINS, JOAO F.T. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:33:41Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:35Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
|
3 |
Desenvolvimento do cristal semicondutor de iodeto de mercúrio para aplicação como detector de radiação / Development of the mercury iodine semiconductor crystal for application as a radiation detectorMARTINS, JOAO F.T. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:33:41Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:35Z (GMT). No. of bitstreams: 0 / Neste trabalho descreve-se o estudo do estabelecimento de uma técnica para o crescimento e preparo de cristais de HgI2, com o intuito de utilizá-los como detectores semicondutores de radiação que operam a temperatura ambiente. Três métodos de crescimento de cristais foram estudados no desenvolvimento deste trabalho: (1) Transporte Físico de Vapor (Physical Vapor Transport PVT), (2) Solução Saturada de HgI2 empregando dois solventes distintos; Dimetil Sulfóxido (DMSO) (a) e acetona (b) e (3) método de Bridgman. A fim de avaliar os cristais de HgI2 desenvolvidos pelos três métodos, medidas sistemáticas foram realizadas para determinar a estrutura, o plano de orientação, a estequiometria, a morfologia da superfície e as impurezas do cristal. A influência destas propriedades físico-químicas sobre os cristais desenvolvidos foi avaliada em termos de desempenho como detector de radiação. Os difratogramas indicaram que os cristais estão orientados preferencialmente planos (001) e (101) com estrutura tetragonal para todos os cristais desenvolvidos. No entanto, a morfologia com menor nível de deformação foi observada para o cristal obtido pela técnica de PVT. Uma uniformidade na camada de superfície do cristal de PVT foi observada, enquanto na superfície do cristal de DMSO podem ser nitidamente encontradas incrustações de elementos distintos ao cristal. A melhor resposta de radiação foi encontrada para os cristais crescidos pela PVT. Significativa melhora no desempenho do detector de radiação de HgI2 foi encontrada, purificando o cristal por meio de dois crescimentos sucessivos, pela técnica de PVT. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
|
4 |
The application of a semiconductor detector in the estimation of the effective dose in radiographic examination of the extremitiesEyden, Alison C. January 2001 (has links)
No description available.
|
5 |
Modernizace vnitřního detektoru ATLAS / Modernizace vnitřního detektoru ATLASMészárosová, Lucia January 2016 (has links)
The main goal of this master thesis is, at first, to describe upcoming upgrade of ATLAS experiment in CERN in Switzerland and to describe the principle of strip silicon detectors. Then it is measurement and analysis of data from laser tests with two lasers: red and infra-red. Last but not least goal is to document the method of measurement and analysis of laser tests for the future laser tests. The text of the thesis is divided into five chapters. The first chapter is dedicated to the research facility CERN, its present experiment ATLAS and future experiment ATLAS Upgrade. The second chapter explains properties of semiconductors and the principle of strip semiconductor detectors. The third chapter describes whole measurement layout: a lab for testing, equipment needed for the tests and the whole system functioning. In the fourth chapter there are actual results from the laser tests. The tests were done on two end-cap prototype modules for ATLAS Upgrade with strip silicon sensors using two lasers: red and infra-red. The last chapter briefly explains the functions of macros that were created for measuring and analysing data from laser tests.
|
6 |
Avaliação dosimétrica de detectores semicondutores para aplicação na dosimetria e microdosimetria em reatores nucleares e instalações de radiocirugia / Dosimetric evaluation of semiconductor detectors for application in neutron dosimetry and microdosimetry in nuclear reactor and radiosurgical facilitiesCárdenas, José Patricio Náhuel 19 April 2010 (has links)
Este trabalho tem como objetivo a avaliação dosimétrica de componentes semicondutores (detectores Barreira de Superfície e fotodiodos PIN) para aplicação em medições de dose equivalente em campos de baixo fluxo de nêutrons (rápidos e térmicos), utilizando uma fonte de AmBe de alto fluxo, a instalação de Neutrongrafia do reator IEA-R1 (fluxos térmicos/epitérmicos) e fluxo de nêutrons rápidos do núcleo do reator IPEN/MB-01 (UCRI Unidade Crítica). Para a detecção de nêutrons (térmicos, epitérmicos e rápidos) foram usados componentes moderadores e conversores (parafina, boro e polietileno). Os fluxos resultantes da moderação e conversão foram utilizados para a irradiação de componentes semicondutores (SSB - Barreira de Superfície e fotodiodos). Foi utilizado também um conversor misto constituído de uma folha de polietileno borado (marca Kodak). O método de simulação por Monte Carlo foi utilizado para avaliar de forma analítica a espessura ótima da parafina. O resultado obtido foi similar ao verificado experimentalmente e serviu para avaliar o fluxo de nêutrons emergentes do moderador (parafina). Da mesma forma, através de simulação, foi avaliado também o fluxo de nêutrons rápidos que atinge o conversor de polietileno que cobre a face sensível dos semicondutores. O nível de radiação gama foi avaliado cobrindo o detector por inteiro com uma folha de cádmio de 1 mm de espessura. O reator IPEN/MB-01 foi usado para avaliar a resposta dos detectores para nêutrons rápidos de alto fluxo. Os resultados, de uma forma geral, mostraram concordância e similaridade com os trabalhos desenvolvidos por outros grupos de pesquisas. Foi também estabelecida uma abordagem para o cálculo de dose equivalente utilizando os espectros obtidos nas experiências. / The main objetive of this research is the dosimetric evaluation of semiconductor componentes (surface barrier detectors and PIN photodiodes) for applications in dose equivalent measurements on low dose fields (fast and thermal fluxes) using an AmBe neutron source, the IEA-R1 reactor neutrongraphy facility (epithermal and thermal fluxes) and the Critical Unit facility IPEN/MB-01 (fast fluxes). As moderator compound to fast neutrons flux from the AmBe source was used paraffin and boron and polyethylene as converter for thermal and fast neutrons measurements. The resulting fluxes were used to the irradiation of semiconductor components (SSB Surface Barrier Detector and PIN photodiodes). A mixed converter made of a borated polyethylene foil (Kodak) was also used. Monte Carlo simulation metodology was employed to evaluate analytically the optimal paraffin thickness. The obtained results were similar to the experimental data and allowed the evaluation of emerging neutron flux from moderator, as well as the fast neutron flux reaching the polyethylene covering the semiconductor sensitive surface. Gamma radiation levels were evaluated covering the whole detector with cadmium foil 1 mm thick, allowing thermal neutrons blockage and gamma radiation measurements. The IPEN/MB-01 facility was employed to evaluate the detector response for high neutron flux. The results were in good agreement with other studies published. Using the obtained spectra an approach to dose equivalent calculation was established.
|
7 |
Avaliação dosimétrica de detectores semicondutores para aplicação na dosimetria e microdosimetria em reatores nucleares e instalações de radiocirugia / Dosimetric evaluation of semiconductor detectors for application in neutron dosimetry and microdosimetry in nuclear reactor and radiosurgical facilitiesJosé Patricio Náhuel Cárdenas 19 April 2010 (has links)
Este trabalho tem como objetivo a avaliação dosimétrica de componentes semicondutores (detectores Barreira de Superfície e fotodiodos PIN) para aplicação em medições de dose equivalente em campos de baixo fluxo de nêutrons (rápidos e térmicos), utilizando uma fonte de AmBe de alto fluxo, a instalação de Neutrongrafia do reator IEA-R1 (fluxos térmicos/epitérmicos) e fluxo de nêutrons rápidos do núcleo do reator IPEN/MB-01 (UCRI Unidade Crítica). Para a detecção de nêutrons (térmicos, epitérmicos e rápidos) foram usados componentes moderadores e conversores (parafina, boro e polietileno). Os fluxos resultantes da moderação e conversão foram utilizados para a irradiação de componentes semicondutores (SSB - Barreira de Superfície e fotodiodos). Foi utilizado também um conversor misto constituído de uma folha de polietileno borado (marca Kodak). O método de simulação por Monte Carlo foi utilizado para avaliar de forma analítica a espessura ótima da parafina. O resultado obtido foi similar ao verificado experimentalmente e serviu para avaliar o fluxo de nêutrons emergentes do moderador (parafina). Da mesma forma, através de simulação, foi avaliado também o fluxo de nêutrons rápidos que atinge o conversor de polietileno que cobre a face sensível dos semicondutores. O nível de radiação gama foi avaliado cobrindo o detector por inteiro com uma folha de cádmio de 1 mm de espessura. O reator IPEN/MB-01 foi usado para avaliar a resposta dos detectores para nêutrons rápidos de alto fluxo. Os resultados, de uma forma geral, mostraram concordância e similaridade com os trabalhos desenvolvidos por outros grupos de pesquisas. Foi também estabelecida uma abordagem para o cálculo de dose equivalente utilizando os espectros obtidos nas experiências. / The main objetive of this research is the dosimetric evaluation of semiconductor componentes (surface barrier detectors and PIN photodiodes) for applications in dose equivalent measurements on low dose fields (fast and thermal fluxes) using an AmBe neutron source, the IEA-R1 reactor neutrongraphy facility (epithermal and thermal fluxes) and the Critical Unit facility IPEN/MB-01 (fast fluxes). As moderator compound to fast neutrons flux from the AmBe source was used paraffin and boron and polyethylene as converter for thermal and fast neutrons measurements. The resulting fluxes were used to the irradiation of semiconductor components (SSB Surface Barrier Detector and PIN photodiodes). A mixed converter made of a borated polyethylene foil (Kodak) was also used. Monte Carlo simulation metodology was employed to evaluate analytically the optimal paraffin thickness. The obtained results were similar to the experimental data and allowed the evaluation of emerging neutron flux from moderator, as well as the fast neutron flux reaching the polyethylene covering the semiconductor sensitive surface. Gamma radiation levels were evaluated covering the whole detector with cadmium foil 1 mm thick, allowing thermal neutrons blockage and gamma radiation measurements. The IPEN/MB-01 facility was employed to evaluate the detector response for high neutron flux. The results were in good agreement with other studies published. Using the obtained spectra an approach to dose equivalent calculation was established.
|
8 |
Avaliacao dosimetrica de detectores semicondutores para aplicacao na dosimetria e microdosimetria de neutrons em reatores nucleares e instalacoes de radiocirurgia / Dosimetric evaluation of semiconductor detectors for application in neutron dosimetry and microdosimetry in nuclear reactor and radio surgical facilitiesNAHUEL CARDENAS, JOSE P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:27:41Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:28Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
9 |
Desenvolvimento de um sistema dosimetrico multidiodos para garantia da qualidade em equipamentos radioterapeuticosSANTOS, GELSON P. dos 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:47:44Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:39Z (GMT). No. of bitstreams: 1
08314.pdf: 4232246 bytes, checksum: 37d2f607f0221e0096bb76c5f12711e9 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
10 |
Espectrometria de raios-x com diodos de SiMAGALHAES, RODRIGO R. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:12Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:56Z (GMT). No. of bitstreams: 1
06889.pdf: 2660879 bytes, checksum: 1ad6cb9abd7b6c1a92d40f0b7cb82b55 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP / FAPESP:97/12485-4
|
Page generated in 0.0866 seconds