• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Computational Methods for Sensitivity Analysis with Applications to Elliptic Boundary Value Problems

Stanley, Lisa Gayle 26 August 1999 (has links)
Sensitivity analysis is a useful mathematical tool for many designers, engineers and mathematicians. This work presents a study of sensitivity equation methods for elliptic boundary value problems posed on parameter dependent domains. The current focus of our efforts is the construction of a rigorous mathematical framework for sensitivity analysis and the subsequent development of efficient, accurate algorithms for sensitivity computation. In order to construct the framework, we use the classical theory of partial differential equations along with the method of mappings and the Implicit Function Theorem. Examples are given which illustrate the use of the framework, and some of the shortcomings of the theory are also identified. An overview of some computational methods which make use of the method of mappings is also included. Numerical results for a specific example show that convergence (energy norm) of the sensitivity approximations can be influenced by the specific structure of the computational scheme. / Ph. D.
2

Estimação de parâmetros de modelos compartimentais para tomografia por emissão de pósitrons. / Parameter estimation of compartmental models for positron emission tomography.

Silva, João Eduardo Maeda Moreira da 23 April 2010 (has links)
O presente trabalho possui como metas o estudo, simulação, identificação de parâmetros e comparação estatística de modelos compartimentais utilizados em tomografia por emissão de pósitrons (PET). Para tanto, propõe-se utilizar a metodologia de equações de sensibilidade e o método de Levenberg-Marquardt para a tarefa de estimação de parâmetros característicos das equações diferenciais descritoras dos referidos sistemas. Para comparação entre modelos, foi empregado o critério de informação de Akaike. São consideradas três estruturas compartimentais compostas, respectivamente, por dois compartimentos e duas constantes características, três compartimentos e quatro constantes características e quatro compartimentos e seis constantes características. Os dados considerados neste texto foram sintetizados preocupando-se em reunir as principais características de um exame de tomografia real, tais como tipo e nível de ruído e morfologia de função de excitação do sistema. Para tanto, foram utilizados exames de pacientes do setor de Medicina Nuclear do Instituto do Coração da Faculdade de Medicina da Universidade de São Paulo. Aplicando-se a metodologia proposta em três níveis de ruído (baixo, médio e alto), obteve-se concordância do melhor modelo em graus forte e considerável (com índices de Kappa iguais a 0.95, 0.93 e 0.63, respectivamente). Observou-se que, com elevado nível de ruído e modelos mais complexos (quatro compartimentos), a classificação se deteriora devido ao pequeno número de dados para a decisão. Foram desenvolvidos programas e uma interface gráfica que podem ser utilizadas na investigação, elaboração, simulação e identificação de parâmetros de modelos compartimentais para apoio e análise de diagnósticos clínicos e práticas científicas. / This work has as goals the study, simulation, parameter identification and statistical comparison of compartmental models used in positron emission tomography (PET). We propose to use the methodology of sensitivity equations and the method of Levenberg-Marquardt for the task of estimating the characteristic parameters of the differential equations describing such systems. For model comparison, Akaikes information criterion is applied. We have considered three compartmental structures represented, respectively, by two compartments and two characteristic constants, three compartments and four characteristic constants and four compartments and six characteristics constants. The data considered in this work were synthesized taking into account key features of a real tomography exam, such as type and level of noise and morphology of the input function of the system. To this end, we used tests of patients in the sector of Nuclear Medicine of the Heart Institute of the Faculty of Medicine, University of São Paulo. Applying the proposed methodology with three noise levels (low, medium and high), we obtained agreement of the best model with strong and considerable degrees (with Kappa indexes equal to 0.95, 0.93 and 0.63, respectively). It was observed that, with high noise level and more complex models (four compartments), the classification is deteriorated due to lack of data for the decision. Programs have been developed and a graphical interface that can be used in research, development, simulation and parameter identification of compartmental models, supporting analysis of clinical diagnostics and scientific practices.
3

Estimação de parâmetros de modelos compartimentais para tomografia por emissão de pósitrons. / Parameter estimation of compartmental models for positron emission tomography.

João Eduardo Maeda Moreira da Silva 23 April 2010 (has links)
O presente trabalho possui como metas o estudo, simulação, identificação de parâmetros e comparação estatística de modelos compartimentais utilizados em tomografia por emissão de pósitrons (PET). Para tanto, propõe-se utilizar a metodologia de equações de sensibilidade e o método de Levenberg-Marquardt para a tarefa de estimação de parâmetros característicos das equações diferenciais descritoras dos referidos sistemas. Para comparação entre modelos, foi empregado o critério de informação de Akaike. São consideradas três estruturas compartimentais compostas, respectivamente, por dois compartimentos e duas constantes características, três compartimentos e quatro constantes características e quatro compartimentos e seis constantes características. Os dados considerados neste texto foram sintetizados preocupando-se em reunir as principais características de um exame de tomografia real, tais como tipo e nível de ruído e morfologia de função de excitação do sistema. Para tanto, foram utilizados exames de pacientes do setor de Medicina Nuclear do Instituto do Coração da Faculdade de Medicina da Universidade de São Paulo. Aplicando-se a metodologia proposta em três níveis de ruído (baixo, médio e alto), obteve-se concordância do melhor modelo em graus forte e considerável (com índices de Kappa iguais a 0.95, 0.93 e 0.63, respectivamente). Observou-se que, com elevado nível de ruído e modelos mais complexos (quatro compartimentos), a classificação se deteriora devido ao pequeno número de dados para a decisão. Foram desenvolvidos programas e uma interface gráfica que podem ser utilizadas na investigação, elaboração, simulação e identificação de parâmetros de modelos compartimentais para apoio e análise de diagnósticos clínicos e práticas científicas. / This work has as goals the study, simulation, parameter identification and statistical comparison of compartmental models used in positron emission tomography (PET). We propose to use the methodology of sensitivity equations and the method of Levenberg-Marquardt for the task of estimating the characteristic parameters of the differential equations describing such systems. For model comparison, Akaikes information criterion is applied. We have considered three compartmental structures represented, respectively, by two compartments and two characteristic constants, three compartments and four characteristic constants and four compartments and six characteristics constants. The data considered in this work were synthesized taking into account key features of a real tomography exam, such as type and level of noise and morphology of the input function of the system. To this end, we used tests of patients in the sector of Nuclear Medicine of the Heart Institute of the Faculty of Medicine, University of São Paulo. Applying the proposed methodology with three noise levels (low, medium and high), we obtained agreement of the best model with strong and considerable degrees (with Kappa indexes equal to 0.95, 0.93 and 0.63, respectively). It was observed that, with high noise level and more complex models (four compartments), the classification is deteriorated due to lack of data for the decision. Programs have been developed and a graphical interface that can be used in research, development, simulation and parameter identification of compartmental models, supporting analysis of clinical diagnostics and scientific practices.

Page generated in 0.1138 seconds