• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • Tagged with
  • 12
  • 12
  • 6
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Diagnóstico bolométrico no TCABR / Bolometric diagnosis in the TCABR

Bellintani Junior, Valdemar 26 August 2005 (has links)
Foi projetado, construído e instalado um sistema bolométrico para a análise das descargas de plasma do TCABR. Este sistema possibilita a observação da coluna de plasma através de cordas caracterizadas por diferentes direções e ângulos. Os bolômetros utilizados são fotodiodos especiais, acondicionados em câmeras dotadas de colimadores para observação do plasma. A faixa espectral da sensibilidade dos fotodiôdos abrange desde o visível até a região de raios-X moles, energia de fótons desde 7 eV até 6.000 eV. Para este diagnóstico, foi construída uma eletrônica específica para amplificação dos sinais bolométricos. A resolução temporal do diagnóstico é de 3 ms devido a interferência gerada pelo tokamak. Com este sistema, foi obtido pela primeira vez no TCABR, o perfil da potência emitida pela coluna de plasma, sendo este o principal resultado deste trabalho. Para isto, foi desenvolvido um programa destinado a inverter os dados bolométricos utilizando como princípio o método de Abel. Uma série de descargas ôhmicas ( 0,9 X \"10 POT.19\" < ne < 2,0 X 10 POT.19\" \"m POT.3\" e 67 < \"I IND.p\" < 100 kA) foram estudadas com o diagnóstico. Obteve-se para o volume da coluna uma fração Prad/Poh não maior que 30%, valor semelhante ao obtido para o tokamak TCA. Observou-se também diferenças acentuadas para o perfil de potência emitido por descargas com baixos e altos valores da corrente de plasma. Estas diferenças são atribuídas principalmente ao aumento da temperatura eletrônica. A concentração de impurezas metálicas foi calculada no eixo da coluna, obtendo-se valores entre 0,9-1,2 X \"10 POT.17\" \"m POT.-3\" / In this work, a bolometric diagnostic system was projected, built and installed in the TCABR tokamak, in order to measure the total power radiation loss from the plasma. The system allows plasma observation through 27 lines of sight with different directions and angles. The detector used was a silicon p-n junction photodiode array, for applications in the vacuum ultraviolet and the soft x-ray (XUV, energy range 7 eV to 6 keV) spectral region. An electronic system for amplification of the bolometer signal was also projected and built. This system was projected taking into account the strong electromagnetic noise due to the tokamak operation. Using this bolometric system, the shape of the emitted power was obtained for the first time in the TCABR, and this is the main result of this work. To deal with the bolometric data, we developed a program based on the Abel inversion. A serie of ohmic discharges were studied with this diagnostic. The value of the Prad/Poh obtained for this serie was below 30%, in agreement with the old TCA data. The shape for discharges with high and low plasma current were also analyzed. We find a big difference in the two cases, showing the effect of electron temperature change. The metallic impurity density on axis were calculated using the value of Prad(0) experimentally obtained. For the serie of discharges analyzed, this value remained between 0,9-1,2 X \"10 POT.17\" \"m POT.-3\"
2

Desenvolvimento e otimização de um fotodetector de silício bidimensional sensível à posição

Silva, Ricardo Cunha Gonçalves da January 2004 (has links)
O conhecimento da física de semicondutores foi usado para desenvolver e otimizar um sensor ótico de silício capaz de determinar com precisão a posição bidimensional de incidência de um feixe de luz em sua superfície. O sensor usa o efeito de fototensão lateral para gerar um sinal elétrico de saída que é função da posição de incidência da luz. Tecnologia planar do silício foi usada na fabricação do dispositivo, incluindo implantação iônica, difusão, fotolitografia, deposição de filmes metálicos e crescimento de dielétricos. A caracterização elétrica do sensor inclui medidas estáticas, com a distribuição de portadores em regime estacionário, medidas dinâmicas, onde é analisado o transiente do sinal elétrico e medidas espectroscópicas para analisar a resposta do sensor em função do comprimento de onda da luz incidente. Simulações dos processos de fabricação, parâmetros dos passos tecnológicos, distribuição dos portadores e do potencial elétrico bidimensional no sensor foram usadas para a otimização das características do sensor.
3

Síntese de líquidos iônicos anfifílicos derivados de Oxa (tia) zolidinas e estudo da interação com BSA e lipossomas

Borba, Laise Costa January 2018 (has links)
Os líquidos iônicos, por geralmente apresentar, em sua estrutura, uma cadeia alquílica apolar e uma parte polar, como o cátion imidazólio, podem ser considerados estruturas anfifílicas, e apresentam semelhanças com os tensoativos. Tais estruturas, devido a este caráter anfifílico, podem interagir com estruturas do tipo Lipossomas ou até mesmo com biomoléculas, como a BSA. Neste trabalho, foram sintetizados três líquidos iônicos inéditos, com rendimentos de 52 a 66%, acoplados a sistemas quirais derivados de aminoácidos naturais e de fácil obtenção, como a L-Cisteína, a L-Serina e a L-Treonina. Estes foram caracterizados tanto do ponto de vista estrutural, quanto por suas propriedades fotofísicas. Como procedimento metodológico utilizou-se de ciclocondensação de aminoácidos, esterificação de Steglich e alquilação para inserção de cadeia carbônica ao anel metil-imidazol. Para investigação e confirmação dessas estruturas utilizou-se de estudos de Ressonância Magnética de 1H e de 13C, Infravermelho, além das espectroscopias de absorção na região do UV-Vis e de emissão de fluorescência. Por fim, estes novos líquidos iônicos foram testados com lipossomas e BSA, cujos resultados mostraram boa interação com essas biomoléculas. / Ionic liquids can be considered as amphiphilic structures and have similarities with the surfactants, once they generally have an apolar alkyl chain and a polar moiety, such as the imidazolium cation. Such structures, due to this amphiphilic character, may interact with liposome structures or even with biomolecules, such as BSA. In this work, three new ionic liquids containing chiral systems derived from naturally occurring amino acids, such as L-Cysteine, L-Serine and L-Threonine were synthesized, with yields ranging from 52 to 66%. They were fully characterized both from the structural point of view, and by its photophysical properties. As methodological procedures, amino acid cyclocondensation, Steglich esterification and alkylation were used. In order to investigate and confirm these structures, magnetic resonance studies of 1H and 13C, infrared, as well as absorption spectroscopies in the UV-Vis region and fluorescence emission were used. At last, these new ionic liquids were tested with liposomes and BSA, and the results showed good interaction with these biomolecules.
4

Desenvolvimento e otimização de um fotodetector de silício bidimensional sensível à posição

Silva, Ricardo Cunha Gonçalves da January 2004 (has links)
O conhecimento da física de semicondutores foi usado para desenvolver e otimizar um sensor ótico de silício capaz de determinar com precisão a posição bidimensional de incidência de um feixe de luz em sua superfície. O sensor usa o efeito de fototensão lateral para gerar um sinal elétrico de saída que é função da posição de incidência da luz. Tecnologia planar do silício foi usada na fabricação do dispositivo, incluindo implantação iônica, difusão, fotolitografia, deposição de filmes metálicos e crescimento de dielétricos. A caracterização elétrica do sensor inclui medidas estáticas, com a distribuição de portadores em regime estacionário, medidas dinâmicas, onde é analisado o transiente do sinal elétrico e medidas espectroscópicas para analisar a resposta do sensor em função do comprimento de onda da luz incidente. Simulações dos processos de fabricação, parâmetros dos passos tecnológicos, distribuição dos portadores e do potencial elétrico bidimensional no sensor foram usadas para a otimização das características do sensor.
5

Síntese de líquidos iônicos anfifílicos derivados de Oxa (tia) zolidinas e estudo da interação com BSA e lipossomas

Borba, Laise Costa January 2018 (has links)
Os líquidos iônicos, por geralmente apresentar, em sua estrutura, uma cadeia alquílica apolar e uma parte polar, como o cátion imidazólio, podem ser considerados estruturas anfifílicas, e apresentam semelhanças com os tensoativos. Tais estruturas, devido a este caráter anfifílico, podem interagir com estruturas do tipo Lipossomas ou até mesmo com biomoléculas, como a BSA. Neste trabalho, foram sintetizados três líquidos iônicos inéditos, com rendimentos de 52 a 66%, acoplados a sistemas quirais derivados de aminoácidos naturais e de fácil obtenção, como a L-Cisteína, a L-Serina e a L-Treonina. Estes foram caracterizados tanto do ponto de vista estrutural, quanto por suas propriedades fotofísicas. Como procedimento metodológico utilizou-se de ciclocondensação de aminoácidos, esterificação de Steglich e alquilação para inserção de cadeia carbônica ao anel metil-imidazol. Para investigação e confirmação dessas estruturas utilizou-se de estudos de Ressonância Magnética de 1H e de 13C, Infravermelho, além das espectroscopias de absorção na região do UV-Vis e de emissão de fluorescência. Por fim, estes novos líquidos iônicos foram testados com lipossomas e BSA, cujos resultados mostraram boa interação com essas biomoléculas. / Ionic liquids can be considered as amphiphilic structures and have similarities with the surfactants, once they generally have an apolar alkyl chain and a polar moiety, such as the imidazolium cation. Such structures, due to this amphiphilic character, may interact with liposome structures or even with biomolecules, such as BSA. In this work, three new ionic liquids containing chiral systems derived from naturally occurring amino acids, such as L-Cysteine, L-Serine and L-Threonine were synthesized, with yields ranging from 52 to 66%. They were fully characterized both from the structural point of view, and by its photophysical properties. As methodological procedures, amino acid cyclocondensation, Steglich esterification and alkylation were used. In order to investigate and confirm these structures, magnetic resonance studies of 1H and 13C, infrared, as well as absorption spectroscopies in the UV-Vis region and fluorescence emission were used. At last, these new ionic liquids were tested with liposomes and BSA, and the results showed good interaction with these biomolecules.
6

Diagnóstico bolométrico no TCABR / Bolometric diagnosis in the TCABR

Valdemar Bellintani Junior 26 August 2005 (has links)
Foi projetado, construído e instalado um sistema bolométrico para a análise das descargas de plasma do TCABR. Este sistema possibilita a observação da coluna de plasma através de cordas caracterizadas por diferentes direções e ângulos. Os bolômetros utilizados são fotodiodos especiais, acondicionados em câmeras dotadas de colimadores para observação do plasma. A faixa espectral da sensibilidade dos fotodiôdos abrange desde o visível até a região de raios-X moles, energia de fótons desde 7 eV até 6.000 eV. Para este diagnóstico, foi construída uma eletrônica específica para amplificação dos sinais bolométricos. A resolução temporal do diagnóstico é de 3 ms devido a interferência gerada pelo tokamak. Com este sistema, foi obtido pela primeira vez no TCABR, o perfil da potência emitida pela coluna de plasma, sendo este o principal resultado deste trabalho. Para isto, foi desenvolvido um programa destinado a inverter os dados bolométricos utilizando como princípio o método de Abel. Uma série de descargas ôhmicas ( 0,9 X \"10 POT.19\" < ne < 2,0 X 10 POT.19\" \"m POT.3\" e 67 < \"I IND.p\" < 100 kA) foram estudadas com o diagnóstico. Obteve-se para o volume da coluna uma fração Prad/Poh não maior que 30%, valor semelhante ao obtido para o tokamak TCA. Observou-se também diferenças acentuadas para o perfil de potência emitido por descargas com baixos e altos valores da corrente de plasma. Estas diferenças são atribuídas principalmente ao aumento da temperatura eletrônica. A concentração de impurezas metálicas foi calculada no eixo da coluna, obtendo-se valores entre 0,9-1,2 X \"10 POT.17\" \"m POT.-3\" / In this work, a bolometric diagnostic system was projected, built and installed in the TCABR tokamak, in order to measure the total power radiation loss from the plasma. The system allows plasma observation through 27 lines of sight with different directions and angles. The detector used was a silicon p-n junction photodiode array, for applications in the vacuum ultraviolet and the soft x-ray (XUV, energy range 7 eV to 6 keV) spectral region. An electronic system for amplification of the bolometer signal was also projected and built. This system was projected taking into account the strong electromagnetic noise due to the tokamak operation. Using this bolometric system, the shape of the emitted power was obtained for the first time in the TCABR, and this is the main result of this work. To deal with the bolometric data, we developed a program based on the Abel inversion. A serie of ohmic discharges were studied with this diagnostic. The value of the Prad/Poh obtained for this serie was below 30%, in agreement with the old TCA data. The shape for discharges with high and low plasma current were also analyzed. We find a big difference in the two cases, showing the effect of electron temperature change. The metallic impurity density on axis were calculated using the value of Prad(0) experimentally obtained. For the serie of discharges analyzed, this value remained between 0,9-1,2 X \"10 POT.17\" \"m POT.-3\"
7

Desenvolvimento e otimização de um fotodetector de silício bidimensional sensível à posição

Silva, Ricardo Cunha Gonçalves da January 2004 (has links)
O conhecimento da física de semicondutores foi usado para desenvolver e otimizar um sensor ótico de silício capaz de determinar com precisão a posição bidimensional de incidência de um feixe de luz em sua superfície. O sensor usa o efeito de fototensão lateral para gerar um sinal elétrico de saída que é função da posição de incidência da luz. Tecnologia planar do silício foi usada na fabricação do dispositivo, incluindo implantação iônica, difusão, fotolitografia, deposição de filmes metálicos e crescimento de dielétricos. A caracterização elétrica do sensor inclui medidas estáticas, com a distribuição de portadores em regime estacionário, medidas dinâmicas, onde é analisado o transiente do sinal elétrico e medidas espectroscópicas para analisar a resposta do sensor em função do comprimento de onda da luz incidente. Simulações dos processos de fabricação, parâmetros dos passos tecnológicos, distribuição dos portadores e do potencial elétrico bidimensional no sensor foram usadas para a otimização das características do sensor.
8

Síntese de líquidos iônicos anfifílicos derivados de Oxa (tia) zolidinas e estudo da interação com BSA e lipossomas

Borba, Laise Costa January 2018 (has links)
Os líquidos iônicos, por geralmente apresentar, em sua estrutura, uma cadeia alquílica apolar e uma parte polar, como o cátion imidazólio, podem ser considerados estruturas anfifílicas, e apresentam semelhanças com os tensoativos. Tais estruturas, devido a este caráter anfifílico, podem interagir com estruturas do tipo Lipossomas ou até mesmo com biomoléculas, como a BSA. Neste trabalho, foram sintetizados três líquidos iônicos inéditos, com rendimentos de 52 a 66%, acoplados a sistemas quirais derivados de aminoácidos naturais e de fácil obtenção, como a L-Cisteína, a L-Serina e a L-Treonina. Estes foram caracterizados tanto do ponto de vista estrutural, quanto por suas propriedades fotofísicas. Como procedimento metodológico utilizou-se de ciclocondensação de aminoácidos, esterificação de Steglich e alquilação para inserção de cadeia carbônica ao anel metil-imidazol. Para investigação e confirmação dessas estruturas utilizou-se de estudos de Ressonância Magnética de 1H e de 13C, Infravermelho, além das espectroscopias de absorção na região do UV-Vis e de emissão de fluorescência. Por fim, estes novos líquidos iônicos foram testados com lipossomas e BSA, cujos resultados mostraram boa interação com essas biomoléculas. / Ionic liquids can be considered as amphiphilic structures and have similarities with the surfactants, once they generally have an apolar alkyl chain and a polar moiety, such as the imidazolium cation. Such structures, due to this amphiphilic character, may interact with liposome structures or even with biomolecules, such as BSA. In this work, three new ionic liquids containing chiral systems derived from naturally occurring amino acids, such as L-Cysteine, L-Serine and L-Threonine were synthesized, with yields ranging from 52 to 66%. They were fully characterized both from the structural point of view, and by its photophysical properties. As methodological procedures, amino acid cyclocondensation, Steglich esterification and alkylation were used. In order to investigate and confirm these structures, magnetic resonance studies of 1H and 13C, infrared, as well as absorption spectroscopies in the UV-Vis region and fluorescence emission were used. At last, these new ionic liquids were tested with liposomes and BSA, and the results showed good interaction with these biomolecules.
9

Detecção de minério portador de elementos de terras raras do depósito de Pitinga/AM, Brasil assistido por tecnologia de sensor-based sorting

Veras, Moacir Medeiros January 2018 (has links)
Este trabalho avalia a afinidade da tecnologia de sensor-based sorting (SBS) assistido com sensor de imagem Charge Couple Device CCD e de Dual Energy-Xray Transmission (DE-XRT) para detectar minérios portadores de elementos de terras raras (ETR). As amostras foram coletadas in situ no depósito de Pitinga/AM-Brasil e enviadas para o LAPROM/UFRGS. Os testes foram realizados sob as mesmas condições operacionais com ambos sensores. As partículas examinadas estão na fração de tamanho entre -10 +5 (cm), limpas e secas antes dos testes. A alimentação para o sorting foi feita manualmente, uma partícula por partícula, garantindo que o sensor capturasse as imagens sob as mesmas condições para cada partícula. Os dados capturados foram processados com software COMEX OSX e CRX, tendo como primeiro estágio a identificação dos melhores parâmetros para a detecção de minérios portadores do mineral de xenotima, rico em elementos de terras raras. A caracterização do material foi realizada por análise química da espectroscopia de massa de plasma acoplado indutivamente (ICP-MS) no Actlabs - Activation Laboratories LTD, além de dados de balanço de massa e cálculos de recuperação. Os resultados mostraram que o sensor óptico reconheceu com sucesso os clastos com características de estéril, porém verificou-se que a detectabilidade efetiva para rochas com mineralização do mineral de xenotima não foi viável. Por outro lado, o sensor DE-XRT mostrou uma forte afinidade de detecção de partículas portadores de elementos leves e pesados de terras raras (ETRL - ETRP) com recuperação mássica acumulada de aproximadamente 15% e recuperação metalúrgica superior a 79% (ETRL) e 89% (ETRP), respectivamente no segundo estágio, e com aproximadamente ~ 66% de recuperação de massa acumulada no terceiro estágio, o teor metalúrgico de ETR leves e pesados foi da ordem de 94% e 96%. Essas recuperações correspondem a um aumento de 514,79 ppm, dos ETRL e 5113,6 ppm dos ETRP, no material investigado representando um upgrade de 10.067,8 ppm nos ETRLe 118.008,3 ppm nos ETRP. Complementarmente foi possível avaliar também que o sensor DE-XRT permite detectar os clastos portadores de ETR sem presença de minérios polimetálicos e deletérios, ficando estes dois últimos associados, considerando a possibilidade de separação empregada usando o sensor de DE-XRT. / This work evaluates the affinity of optical and dual energy x-ray transmission (DE-XRT) sensors to the detection of rare earth element (REE) bearing ores. The samples were collected in situ at the Pitinga/AM-Brazil mine and sent to LAPROM/UFRGS for study. The tests were carried out under the same operating conditions to both sensors. The particles examined were in the size fraction -10 +5 (cm) and were cleaned and dried prior to scanning. The feeding to the sorter was done manually, one particle at a time, ensuring that the sensor captured the images under the same conditions for each particle. The captured data were processed using Comex OSX and CRX software, the first priority being the identification of the best parameters for detecting xenotime mineral, which are rich in rare earth elements. The characterization of the material was performed by chemical analysis of inductively coupled plasma mass spectroscopy (ICP-MS) in the laboratory Actlabs - Activation Laboratories Ltd and mass balance data and recovery calculations. The results showed that the optical sensor successfully recognized the waste particle, but it lacked the capacity to detect rocks of mineralization of xenotime mineral. On the other hand, the DE-XRT sensor showed a strong particle detection capacity for both light and heavy Rare Earth Elements (LREE, HREE) with accumulated mass recovery of approximately 15% and metallurgical recovery higher than 79% (LREE) and 89% (HREE), respectively in the second stage, and ~66% accumulated mass recovery in the third stage with metallurgical content of light and heavy REE in the order of 94% and 96%. In addition, it was also possible to evaluate that the DE-XRT sensor allows the detection of ETR-bearing clasts without the presence of polymetallic and deleterious ores, the latter being associated considering the possibility of separation using the DE-XRT sensor.
10

Detecção de minério portador de elementos de terras raras do depósito de Pitinga/AM, Brasil assistido por tecnologia de sensor-based sorting

Veras, Moacir Medeiros January 2018 (has links)
Este trabalho avalia a afinidade da tecnologia de sensor-based sorting (SBS) assistido com sensor de imagem Charge Couple Device CCD e de Dual Energy-Xray Transmission (DE-XRT) para detectar minérios portadores de elementos de terras raras (ETR). As amostras foram coletadas in situ no depósito de Pitinga/AM-Brasil e enviadas para o LAPROM/UFRGS. Os testes foram realizados sob as mesmas condições operacionais com ambos sensores. As partículas examinadas estão na fração de tamanho entre -10 +5 (cm), limpas e secas antes dos testes. A alimentação para o sorting foi feita manualmente, uma partícula por partícula, garantindo que o sensor capturasse as imagens sob as mesmas condições para cada partícula. Os dados capturados foram processados com software COMEX OSX e CRX, tendo como primeiro estágio a identificação dos melhores parâmetros para a detecção de minérios portadores do mineral de xenotima, rico em elementos de terras raras. A caracterização do material foi realizada por análise química da espectroscopia de massa de plasma acoplado indutivamente (ICP-MS) no Actlabs - Activation Laboratories LTD, além de dados de balanço de massa e cálculos de recuperação. Os resultados mostraram que o sensor óptico reconheceu com sucesso os clastos com características de estéril, porém verificou-se que a detectabilidade efetiva para rochas com mineralização do mineral de xenotima não foi viável. Por outro lado, o sensor DE-XRT mostrou uma forte afinidade de detecção de partículas portadores de elementos leves e pesados de terras raras (ETRL - ETRP) com recuperação mássica acumulada de aproximadamente 15% e recuperação metalúrgica superior a 79% (ETRL) e 89% (ETRP), respectivamente no segundo estágio, e com aproximadamente ~ 66% de recuperação de massa acumulada no terceiro estágio, o teor metalúrgico de ETR leves e pesados foi da ordem de 94% e 96%. Essas recuperações correspondem a um aumento de 514,79 ppm, dos ETRL e 5113,6 ppm dos ETRP, no material investigado representando um upgrade de 10.067,8 ppm nos ETRLe 118.008,3 ppm nos ETRP. Complementarmente foi possível avaliar também que o sensor DE-XRT permite detectar os clastos portadores de ETR sem presença de minérios polimetálicos e deletérios, ficando estes dois últimos associados, considerando a possibilidade de separação empregada usando o sensor de DE-XRT. / This work evaluates the affinity of optical and dual energy x-ray transmission (DE-XRT) sensors to the detection of rare earth element (REE) bearing ores. The samples were collected in situ at the Pitinga/AM-Brazil mine and sent to LAPROM/UFRGS for study. The tests were carried out under the same operating conditions to both sensors. The particles examined were in the size fraction -10 +5 (cm) and were cleaned and dried prior to scanning. The feeding to the sorter was done manually, one particle at a time, ensuring that the sensor captured the images under the same conditions for each particle. The captured data were processed using Comex OSX and CRX software, the first priority being the identification of the best parameters for detecting xenotime mineral, which are rich in rare earth elements. The characterization of the material was performed by chemical analysis of inductively coupled plasma mass spectroscopy (ICP-MS) in the laboratory Actlabs - Activation Laboratories Ltd and mass balance data and recovery calculations. The results showed that the optical sensor successfully recognized the waste particle, but it lacked the capacity to detect rocks of mineralization of xenotime mineral. On the other hand, the DE-XRT sensor showed a strong particle detection capacity for both light and heavy Rare Earth Elements (LREE, HREE) with accumulated mass recovery of approximately 15% and metallurgical recovery higher than 79% (LREE) and 89% (HREE), respectively in the second stage, and ~66% accumulated mass recovery in the third stage with metallurgical content of light and heavy REE in the order of 94% and 96%. In addition, it was also possible to evaluate that the DE-XRT sensor allows the detection of ETR-bearing clasts without the presence of polymetallic and deleterious ores, the latter being associated considering the possibility of separation using the DE-XRT sensor.

Page generated in 0.049 seconds