• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • 1
  • Tagged with
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de sensores eletroquímicos à base de filmes com TCNX (tetracianoquinodimetano e tetracianoetileno) para a determinação de compostos fenólicos / Development of electrochemical sensors based on films containing TCNX (Tetracyanoquinodimethane and tetracyanoethylene) for phenolics compound determination

Luz, Rita de Cássia Silva 26 August 2018 (has links)
Orientador: Lauro Tatsuo Kubota / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-26T13:05:51Z (GMT). No. of bitstreams: 1 Luz_RitadeCassiaSilva_D.pdf: 824556 bytes, checksum: 44fa44dc39ee4ef1973fbd79f8c3e5ba (MD5) Previous issue date: 2007 / Resumo: Neste trabalho é descrito o desenvolvimento de sensores eletroquímicos à base de compostos com TCNX (tetracianoetileno e tetracianoquinodimetano) para a determinação de compostos fenólicos. Para este propósito foram preparados eletrodos de carbono vítreo modificados com tetracianoetileneto de lítio (LiTCNE) e bis(tetracianoquinodimetaneto) de bis(fenantrolina) de cobre (lI) [Cu(phen)2(TCNQ)2], ambos imobilizados em filmes de poli-l-lisina (PLL). Após esta etapa, o eletrodo modificado com LiTCNE/PLL foi testado para verificar a capacidade de eletrocatálise da reação de redução de p-nitrofenol enquanto que o eletrodo modificado com Cu(phen)2(TCNQ)2/PLL foi utilizado para a oxidação de catecol. As técnicas utilizadas para a realização deste trabalho foram a voltametria cíclica, voltametria de varredura linear, amperometria, voltametria de pulso diferencial e voltametria de onda quadrada, as quais foram utilizadas para estudar o comportamento dos eletrodos modificados, para a otimização dos parâmetros experimentais, obtenção dos parâmetros cinéticos e caracterização analítica dos sensores. Os hidrodinâmicos foram realizados com o objetivo de obter maiores informações sobre os processos de redução e oxidação de p-nitrofenol e catecol, respectivamente, sobre os eletrodos modificados. Através do gráfico de Koutech-Levich foi possível obter os valores para o coeficiente de difusão e constante de velocidade da reação (k) para os analitos em estudo. Os valores do coeficiente de difusão e de k, determinados para o p-nitrofenol, foram de 9,03 x 10 cm s e 1,65 x 10 mol L s, enquanto que para o catecol, os valores do coeficiente de difusão e de k, foram de 4,6 x 10 cm s e 1,3 x 10 mol L s, respectivamente. O aumento na velocidade de reação, tanto para o p-nitrofenol como para o catecol, foi atribuído à eficiente transferência eletrônica entre as espécies estudadas e os compostos eletroativos imobilizados nas superficies dos eletrodos de carbono vítreo. O eletrodo modificado com filme de LiTCNE/PLL apresentou uma ampla faixa de resposta linear, sensibilidade, limite de detecção e quantificação de 0,001 a 5 mmol L, 42,90 mA cm L mmol, 0,3 e 1,0 nmol L (n= 10), respectivamente, para o de p-nitrofenol, enquanto que o eletrodo modificado com Cu(phen)2(TCNQ)2/PLL apresentou uma faixa de resposta linear, sensibilidade, limite de detecção e quantificação de 0,005 a 5 mmol L (n=8), 16,10 mA cm, 1,5 e 5,0 nmol L, para o catecol. Após a aplicação destes sensores em amostras de interesse, estudos de adição e recuperação dos analitos foram realizados para avaliar a exatidão dos métodos e verificou-se que em ambos os casos foi possível uma percentagem de recuperação entre 98,87 e 104,5% para o p-nitrofenol e 99,1 e 100,1 % para o catecol / Abstract: In this work is describing the development of electrochemical sensors based on TCNX (tetracyanoquinodimethane and tetracyanoethylene) for phenolics compound determination. For this purpose glass carbon electrodes were modified with lithium tetracyanoethylenide (LiTCNE) and bis (tetracyanoquinodimethanide) of bis (phenantroline) of copper (II) [Cu(phen)2(TCNQ)2], both immobilized at films of poly-l-lysine (PLL). After this step, the modified electrode with LiTCNE/PLL was tested to verify the electrocatalysis capacity of the reduction of p-nitrofenol and the electrode modified with Cu (phen)2(TCNQ)2/PLL for the catechol oxidation. The techniques used for the accomplishment of this work were the cyclic voltametry, linear sweep voltametry, amperometry, differential pulse voltametry, and square wave voltametry, which were used to study the behavior of the modified electrodes, for the experimental parameters optimization, for the attainment of the kinetic parameters and analytical characterization of the sensors. Hydrodynamic studies were carried out with the aim to get information on the reduction processes and oxidation of p-nitrofenol and catechol, respectively, on the modified electrodes. Through the Koutech-Levich plot it was possible to obtain the values for the diffusion coefficient (Do) and kinetic constant of the reaction (k) for the analyte in study. The values of the diffusion coefficient and k, determined for p-nitrofenol, were 9,03 x 10 cm s and 1,65 10 x mol L s, whereas for catechol, the values of Do and k were 4,6 x 10 cm s e 1,3 x 10 mol L s, respectively. The increase of the reaction rate for p-nitrofenol and catechol was attributed to the efficient electron transfer between the studied species and immobilized electroactives species on superface the glassy carbon electrodes surface. The electrode modified with LiTCNE/PLL presented a wide linear response range, as well as sensitivity, detection and quantification limit of 0,001 up to 5 mmol L, 42,90 mA cm L mmol, 0,3 and 1,0 nmol L (n=10) for the p-nitrophenol, whereas the electrode modified with [Cu(phen)2(TCNQ)2], presented a linear range, sensitivity, detection and quantification limit of 0,005 a 5 mmol L (n=8), 16,10 mA cm, 1,5 e 5,0 nmol L, respectively, for catechol. After the application of these sensors in samples of interest, studies of addition and recovery of the analytes were carried out to evaluate the error of the methods and was verified that in both the cases a recovery percentages between 98,8 and 104,5% for p-nitrofenol and, 99,1 e 100,1 % for catechol / Doutorado / Quimica Analitica / Doutora em Ciências
2

Material carbono ceramico condutor SiO2/ZrO2/C-grafite : sintese, caracterização e aplicações / SiO2/ZrO2/C-graphite conducting carbon ceramic material : synthesi characterization and application

Marafon, Eduardo 13 August 2018 (has links)
Orientador: Yoshitaka Gushikem / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-13T19:15:08Z (GMT). No. of bitstreams: 1 Marafon_Eduardo_D.pdf: 4220393 bytes, checksum: 1adee837c254c6481f606e3e1cf1dac1 (MD5) Previous issue date: 2008 / Resumo: O material carbono cerâmico condutor SiO2/ZrO2/C-grafite foi preparado pelo método sol-gel em duas composições: (A) SZC30 (SiO2 = 50 %, ZrO2 = 20 %, C = 30 %) e (B) SZC20 (SiO2 = 60 %, ZrO2 = 20 %, C = 20 %) em % m/m, caracterizado e utilizado para preparar eletrodos. O material carbono cerâmico foi aquecido nas temperaturas de 400, 600, 800 e 1000 °C, em atmosfera de nitrogênio, e foi verificado que o mesmo apresenta alta estabilidade térmica. Verificando-se a cristalização de ZrO2 em 1000 °C, na fase tetragonal, enquanto que SiO2 permanece amorfo. A área superficial específica dos materiais carbono cerâmico SZC20 e SZC30 como preparados, foram respectivamente 45 e 12 mg, enquanto que em temperaturas acima de 600 °C, devido ao colapso dos poros, a área superficial específica dos materiais diminuem para 3 e 4 mcm. As imagens de microscopia eletrônica de transmissão de alta resolução mostraram que as nanopartículas de grafite estão bem dispersas no interior da matriz de SiO2/ZrO2, sendo responsáveis pela elevada condutividade elétrica dos materiais carbono cerâmico SZC 20 e SZC30 prensados na forma de discos, 4 e 18 S cm, respectivamente. Com o material SZC30 foram preparados eletrodos e os mesmos foram modificados com hexacianoferrato(II) de cobre (CuHCF) e flavina adenina dinucleotídeo (FAD). A espessura do filme de CuHCF formado sobre a superfície do eletrodo SZC30 foi estimada como sendo 101 nm, e ele apresentou boa estabilidade química e baixa resistência de transferência de carga. O eletrodo SZC30 modificado com FAD mostrou ser eficiente nas reações de redução eletrocatalítica de íons bromato e iodato, em solução aquosa. A eletroredução de ambos os íons ocorreu num potencial de -0,41 V vs. Eletrodo de calomelano saturado. Os experimentos de cronoamperometria mostraram que o eletrodo carbono cerâmico modificado com FAD apresenta potencial para ser empregado como sensor amperométrico para determinação de bromato e iodato, apresentando limites de detecção de 2,3 e 1,5 mmol L, respectivamente / Abstract: SiO2/ZrO2/C-graphite was prepared by the sol-gel method in two compositions: (A) SZC30 (SiO2 = 50 %, ZrO2 = 20 %, C = 30 %) e (B) SZC20 (SiO2 = 60 %, ZrO2 = 20 %, C = 20 %) in % m/m, characterized and used to prepare electrodes. The carbon ceramic material was thermally treated at 400, 600, 800 and 1000 °C in nitrogen atmosphere, and it was observed that it presents high thermal stability and the crystallization of ZrO2 occurred at 1000 °C in tetragonal phase, while SiO2 remained amorphous. The specific surface area of SZC20 and SZC30 the carbon ceramic materials was, respectively, 45 and 12 mg, as prepared. For materials treated at temperatures higher than 600 °C, due to the collapse of the porous, specific surface area of the materials decrease to 3 and 4 mg. High resolution transmission electron microscopy micrographs showed that the graphite nanoparticles are well dispersed inside SiO2/ZrO2 matrix, and these nanoparticles are responsible for the high electrical conductivity of pressed disks of carbon ceramic materials, 4 and 18 S cm, respectively. The SZC30 material was used to prepare electrodes and they were modified with copper hexacyanoferrate(II) (CuHCF) and flavin adenine dinucleotide (FAD). The thickness of the CuHCF film was estimated as 101 nm, presenting good chemical stability and low charge transfer resistance. FAD modified SZC30 carbon ceramic electrode was efficient for electrocatalytic reduction of bromate and iodate ions, in aqueous solution. The electroreduction of both ions occurred at a peak potential of - 0,41 V vs. saturated calomel electrode. The cronoamperometry experiments showed that FAD modified SZC30 carbon ceramic electrode can be used as an amperometric sensor for bromate and iodate, presenting detection limit of 2,3 and 1,5 mmol L, respectively / Doutorado / Quimica Inorganica / Doutor em Ciencias Quimicas
3

Desenvolvimento de materiais e métodos de fabricação de sensores químicos/bioquímicos baseados em silício e nanoestruturas de carbono (ISFET, CNTFET e GraFET) = Development of materials and methods of fabrication of chemical/biochemical sensors based on silicon and carbon nanostructures (ISFET, CNTFET and GraFET) / Development of materials and methods of fabrication of chemical/biochemical sensors based on silicon and carbon nanostructures (ISFET, CNTFET and GraFET)

Souza, Jair Fernandes de 21 August 2018 (has links)
Orientadores: Peter Jürgen Tatsch, José Alexandre Diniz / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-21T00:22:30Z (GMT). No. of bitstreams: 1 Souza_JairFernandesde_D.pdf: 13128989 bytes, checksum: 25325c1093f208d379ae77adc08c90ff (MD5) Previous issue date: 2012 / Resumo: Este trabalho teve como objetivo o desenvolvimento de materiais e métodos avançados de fabricação de sensores químicos/bioquímicos. Utilizando equipamentos disponíveis no Centro de Componentes Semicondutores da UNICAMP, foram desenvolvidos e caracterizados filmes finos de alta constante dielétrica e filmes metálicos. Os materiais desenvolvidos foram empregados na fabricação de sensores baseados em transistores de efeito de campo sensíveis a íons (ISFET) e em dispositivos de efeito de campo que incorporam nanoestruturas de carbono como elemento funcional [grafeno (GraFET) e nanotubos de carbono (CNTFET)]. A aplicação dos materiais como camada sensível, dielétrico de porta e eletrodos, assim como a utilização de nanoestruturas, tem por objetivo aumentar a sensibilidade e a biocompatibilidade dos dispositivos, construir dispositivos robustos que possam ser empregados em ambientes agressivos e obter sensores com resposta linear e estável com o tempo e temperatura. Foram fabricados, caracterizados e encapsulados ISFET's com camada sensível constituída por filmes finos de nitreto de silício (SiNx)/nitreto de alumínio (AlN) e com eletrodos formados por filmes metálicos de alumínio. Filmes finos de óxido de titânio (TiOx) e óxido de tântalo (TaOx), cujas características são de interesse para aplicação como filme sensível em determinadas aplicações, também foram estudados. Os filmes foram obtidos pelas técnicas de deposição química em fase vapor (LPCVD), sputtering dc e oxidação térmica rápida (RTO). Foram desenvolvidas técnicas de fabricação de dispositivos de efeito de campo baseados em grafeno e nanotubos de carbono, utilizando como dielétrico de porta os filmes finos desenvolvidos para formar a camada sensível dos ISFET's. Entretanto, os eletrodos foram construídos empregando-se filmes finos de nitreto de tântalo (TaN) depositados por sputtering dc. Filmes sensíveis de SiNx são quimicamente estáveis e tornam os sensores robustos com sensibilidade em tensão próxima ao limite de Nernst (59 mV/pH). Entretanto, a grande sensibilidade em tensão obtida (50 mV/pH) não é transformada em alta sensibilidade em corrente (1,35 ?A/pH), devido ao baixo valor de transcondutância observado (19 ?S). Por outro lado, quando se utiliza AlN depositado a temperatura ambiente, tem-se um baixo valor de sensibilidade em tensão (20 mV/pH) que é transformado em uma alta sensibilidade em corrente (28 ?A/pH), em razão da alta transcondutância dos dispositivos (329 ?S). GraFET's e CNTFET's demonstraram a modulação da corrente entre os eletrodos de fonte e dreno pela ação do campo elétrico perpendicular, aplicado com o auxílio do eletrodo de porta. Entretanto, o efeito de campo observado é ambipolar, ou seja, existem dois regimes possíveis de operação dos dispositivos, um regime dominado pelo transporte de lacunas e outro dominado pelo transporte de elétrons. A característica ambipolar possibilita a detecção de moléculas carregadas positiva e negativamente, enquanto que o baixo coeficiente de temperatura do filme de TaN possibilita a utilização dos dispositivos em processos realizados em altas temperaturas / Abstract: The main aim of this work is the development of advanced materials and methods for the fabrication of chemical/biochemical sensors. By using equipments available in the Center of Semiconductor Components of UNICAMP, high dielectric constant thin films and metallic films have been developed and characterized. The materials developed were employed in the fabrication of sensors based on ion-sensitive field effect transistors (ISFET) and in field-effect devices incorporating carbon nanostructures as functional elements [Graphene (GraFET) and carbon nanotubes (CNTFET)]. The application of these materials as sensitive layer, gate dielectric and electrodes, as well as the use of nanostructures, aims to increase the sensitivity and biocompatibility of the devices, to build robust devices that can be used in harsh environments and obtain sensors with linear and stable response over time and temperature. ISFET's with sensitive layer consisting of thin films of silicon nitride (SiNx)/aluminum nitride (AlN) and with electrodes formed by aluminum metallic films were fabricated, characterized and packaged. Thin films of titanium oxide (TiOx) and tantalum oxide (TaOx), whose characteristics are interesting in certain applications, were also studied. The films were obtained by chemical deposition techniques in vapor phase (LPCVD), dc sputtering and rapid thermal oxidation (RTO). Techniques have been developed for manufacturing field effect devices based on graphene and carbon nanotubes, the thin films developed to form the ISFET's sensitive layer were used as gate dielectric. However, the electrodes were built by using thin film of tantalum nitride (TaN) deposited by dc sputtering. SiNx sensitive films are chemically stable and make sensors robust with sensitivity in voltage near to the Nernst limit (59 mV/pH). However, the great sensitivity in voltage (50 mV/pH) is not transformed into high current sensitivity (1.35 ?A/pH), due to the low value of transconductance (19 ?S). On the other hand, when AlN deposited at room temperature is used, a low voltage sensitivity value is obtained (20 mV/pH) that is transformed into a high sensitivity in current (28 ?A/pH), due to high transconductance of the devices (329 ?S). GraFETs and CNTFETs demonstrated the current modulation between the source and drain electrodes by the action of perpendicular electric field, applied with the aid of the gate electrode. However, the field effect observed is ambipolar, in other words, there are two possible operation regime, a regime dominated by the transport of holes and another dominated by transport of electrons. The ambipolar feature enables the detection of positively and negatively charged molecules, while the low temperature coefficient of TaN film allows the use of devices in processes carried out at high temperatures / Doutorado / Eletrônica, Microeletrônica e Optoeletrônica / Doutor em Engenharia Elétrica
4

SiO2/MPc/C e electrically conductive ceramic material (Pc: phthalocyanine, M=Mn(II), Co(II), Cu(II)) a new substrate for the preparation of electrochemical sensors and biosensors = Material cerâmico eletricamente condutor SiO2/MPc/C (Pc: ftalocianina, M=Mn(II), Co(II), Cu(II) um novo substrato para o preparo de sensores e biosensores eletroquímicos / Material cerâmico eletricamente condutor SiO2/MPc/C (Pc: ftalocianina, M=Mn(II), Co(II), Cu(II) um novo substrato para o preparo de sensores e biosensores eletroquímicos

Rahim, Abdur, 1980- 21 August 2018 (has links)
Orientador: Yoshitaka Gushikem / Texto em inglês / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-21T20:29:33Z (GMT). No. of bitstreams: 1 Rahim_Abdur_D.pdf: 2383649 bytes, checksum: 98658562d78717c6e16d2a66e1d8cfa6 (MD5) Previous issue date: 2013 / Resumo: Este trabalho descreve as sínteses, caracterizações e as aplicações dos materiais carbono cerâmicos mesoporosos identificados como: SiO2/20wt%C (SBET= 160 mg) e SiO2/50wt%C (SBET= 170 mg), em que C corresponde ao carbono grafite. Tais materiais foram preparados através do método sol-gel e empregados como matrizes para o desenvolvimento de sensores e biosensores eletroquímicos. Imagens obtidas através da microscopia eletrônica de varredura (MEV) acoplada com a espectrosocopia de energia dispersiva (EDS) mostraram que, com relação as resoluções utilizadas, não foram detectadas segregação de fases. Os materiais que contem 20 e 50 wt% de C apresentaram condutividades elétricas de 9,2 x 10 S cm e 0,49 S cm, respectivamente. Esses materiais foram utilizados como matrizes para suportar ftalocianinas de: cobalto (CoPc), cobre (CuPc) e manganês (MnPc), as quais foram preparadas in situ ao longo de suas superfícies de forma que fosse assegurada dispersão homogênea dos complexos eletroativos nos poros das matrizes. As densidades superficiais da ftalocianina de cobalto em ambas as superfícies da matriz foram: 0,014 mol cm e 0,015 mol cm, para os materiais contendo 20 e 50 % m/m de C, respectivamente. Foram empregados como eletrodos de trabalho pastilhas preparadas a partir dos eletrodos carbono cerâmicos, considerando-se os seguintes materiais: SiO2/C/CoPc, SiO2/C/CuPc e SiO2/C/MnPc. A técnica de XPS foi usada para determinar as proporções de Mn/Si atómicos dos materiais MnPc modificados. O material SiO2/C/CoPc foi testado como um sensor de ácido oxálico e de oxigenio, e os materiais e SiO2/C/CuPc e SiO2/C/MnPc foram testados como sensores para a dopamina e nitrito, respectivamente. Esses materiais tem se mostrado como alternativas promissoras para o desenvolvimento de sensores eletroquímicos e de biosensores, atuando como substratos robustos e versáteis para a construção de novos eletrodos carbono cerâmicos. / Abstract: This work describes the synthesis, characterization and applications of mesoporous carbon ceramic materials identified as: SiO2/20wt%C (SBET = 160 mg) and SiO2/50wt%C (SBET= 170 mg), where C represents the carbon graphite. These materials were prepared by the sol-gel method and used as support for the development of electrochemical sensors and biosensors. Images obtained by scanning electron microscopy (SEM) coupled with energy dispersive spectroscopy (EDS) showed that, within the magnification used, no phase segregation was detectable. The materials containing 20 and 50 wt% of C presented electric conductivities of 9.2×10and 0.49 S cm, respectively. These materials were used as matrices to support manganese phthalocyanines (MnPc), cobalt phthalocyanines (CoPc), and copper phthalocyanines (CuPc), prepared in situ on their surfaces, to assure homogeneous dispersion of the electroactive complex in the pores of matrices. The surface densities of cobalt phthalocyanine on both matrix surfaces were: 0.014 mol cm and 0.015 mol cm, for materials containing 20 and 50% wt% of C, respectively. The pressed disk carbon ceramic electrode: SiO2/C/MnPc, SiO2/C/CoPc, and SiO2/C/CuPc were used as working electrode. XPS was used to determine the Mn/Si atomic ratios of the MnPc-modified materials. The material SiO2/C/CoPc was tested as a sensor for oxalic acid and oxygen and the materials SiO2/C/CuPc and SiO2/C/MnPc were tested as sensors for dopamine and nitrite, respectively. These materials have shown to be promising alternative in the development of electrochemical sensors and biosensor, acting as a robust and versatile conducting substrate for the construction of new carbon ceramic electrodes. / Doutorado / Quimica Inorganica / Doutor em Ciências
5

[pt] DESENVOLVIMENTO DE MÉTODOS ELETRO-ANALÍTICOS USANDO SENSORES MODIFICADOS COM NANOMATERIAIS PARA DETERMINAÇÃO DE PRIMAQUINA, INHHQ, TIOMERSAL E CREATININA / [en] DEVELOPMENT OF ELECTRO-ANALYTICAL METHODS USING SENSORS MODIFIED WITH NANOMATERIALS FOR DETERMINATION OF PRIMAQUINE, INHHQ, THIOMERSAL AND CREATININE

MARLIN JEANNETTE PEDROZO PEÑAFIEL 28 December 2020 (has links)
[pt] O objetivo deste trabalho foi o desenvolvimento de métodos eletro-analíticos utilizando eletrodos modificados com nanomateriais a base de carbono para determinação de analitos de interesse biológico (creatinina) e farmacológico (primaquina, INHHQ, tiomersal). A determinação de primaquina (antimalárico) e de INHHQ (potencial medicamento para o tratamento de doenças neurodegenerativas) foi proposta usando eletrodo de carbono vítreo (GC) modificado com nanotubos de carbono de paredes múltiplas (MWCNTs) o qual promoveu uma melhora significativa na corrente faradaica e na resolução de pico obtida usando voltametria de onda quadrada (SWV) em tampão Britton-Robinson (BR) 0.02 mol L-1; pH 7.00 e KCl (0.25 mol L-1). Embora vários métodos para quantificar primaquina estejam reportados, muitos deles dependem de procedimentos considerados complexos e trabalhosos, portanto, a modificação proposta de GC usando MWCNTs é comparativamente fácil, levando a uma modificação robusta que produz resultados repetitivos, fornecendo também amplificação do sinal eletroquímico devido à área ativa aumentada e a taxa de transferência eletrônica aprimorada. Os GC/MWCNTs também forneceram, ao trabalhar em um pH adequado, maior resolução na detecção das diferentes etapas eletroquímicas envolvidas no processo redox da primaquina. O eletrodo permitiu o limite de detecção (LOD) de 28 nmol L-1 para a primaquina e, quando associado a um procedimento simples baseado na extração líquido-líquido (LLE) e cromatografia em camada fina (TLC), foi alcançada a seletividade e a capacidade de determinar os níveis mais baixos esperados em amostras de urina. No caso do INHHQ, um método para quantificação por SWV foi relatado pela primeira vez. Além do uso do eletrodo GC/MWCNTs um prévio procedimento de TLC, permitiu a seletividade necessária para determinar o INHHQ no tecido cerebral de ratos Wistar. O LOD foi de 0.85 μmol L-1 e a faixa dinâmica linear cobriu duas ordens de magnitude (10-6 a 10-5 mol L-1). Os pontos quânticos de grafeno (GQDs) foram escolhidos para modificar quimicamente os eletrodos utilizados para determinar tiomersal e creatinina. GQDs são fragmentos nanométricos de grafeno (presentes em dispersões como monocamada, poucas camadas ou multicamadas) onde o transporte de elétrons é confinado em suas dimensões. GQDs são estruturas baseadas em carbono que são biocompatíveis e apresentam baixa toxicidade. A pesquisa apresenta uma nova abordagem para a determinação de tiomersal (conservante em vacinas e cosméticos) em vacinas contra influenza usando GQDs como modificador do eletrodo de GC e explorando o efeito sinérgico entre GQDs, radiação visível e a diferença de potencial aplicado. Este sistema promove a oxidação do tiomersal, produzindo um aumento significativo na resposta (par redox Hg/Hg2positivo) em termos de intensidade de corrente usando SWV e tampão BR (0.02 mol L-1; pH 4.00 com KCl a 0.25 mol L-1). O LOD foi de 0.85 μmol L-1 e a faixa dinâmica linear cobriu três ordens de grandeza (10-6 a 10-4 mol L-1). Para a creatinina (um biomarcador para a disfunção renal), um composto de GQDs-cobre foi usado para modificar um eletrodo de ouro. A determinação da creatinina foi realizada utilizando SWV (tampão BR 0.02 mol L-1; pH 4.00 com KCl a 0.25 mol L-1). O método contou com a diminuição do pico de oxidação Cu/Cu2positivo na presença de creatinina, permitindo LOD de 50 nmol L-1 e faixa dinâmica linear, cobrindo três ordens de magnitude (10-6 a 10-4 mol L-1). A resposta SWV da creatinina foi atribuída à formação do complexo creatinina-Cu2+, sendo razoavelmente seletiva em relação a este analito. Todos os procedimentos desenvolvidos por voltametria foram adequadamente comparados com métodos de referência, sendo estatisticamente compatíveis. / [en] The goal of this work was the development of electro-analytical methods using electrodes modified with carbon-based nanomaterials for determination of analytes of biological (creatinine) and pharmacological interest (primaquine, INHHQ, thiomersal). The determination of primaquine (antimalarial) and INHHQ (potential drug for treatment of neurodegenerative diseases) was proposed using glassy carbon (GC) electrode modified with multi-walled carbon nanotubes (MWCNTs) that promoted significant improvement in faradaic current and better peak resolution obtained using square-wave voltammetry (SWV) in Britton-Robinson (BR) buffer 0.02 mol L-1; pH 7.00 and KCl (0.25 mol L-1). Although several methods to quantify primaquine are reported, many of these depend on procedure considered complex and laborious, therefore, the proposed GC modification using MWCNTs is comparatively easy, leading to a robust modification that produce repetitive results also providing amplification of the electrochemical signal due to the increased active area and improved electron-transfer rate. The GC/MWCNTs also provided, when working on a proper pH, higher resolution in detecting the different electrochemical steps involved in the redox process of primaquine. The electrode enabled limit of detection (LOD) of 28 nmol L-1 for primaquine and, when associated with a simple developed procedure, relying of liquid-liquid extraction (LLE) and thin-layer chromatography (TLC), it was achieved the selectivity and the capability to determine the lower levels expected in urine samples. In the case of INHHQ, a method for quantification by SWV was reported for the first time. In addition to the use of GC/MWCNTs electrode, a previous TLC procedure, enabled the selectivity required to determine INHHQ in brain tissue from Wistar rats. The LOD was 0.85 mol L-1 and the linear dynamic range covered two orders of magnitude (10-6 to 10-5 mol L-1). Graphene quantum dots (GQDs) was chosen to chemically modify electrodes used to determine thiomersal and creatinine. GQDs are nanometric fragments of graphene (present in dispersions as monolayer, few layer or multilayer) where electron transport is confined in their dimensions. GQDs are carbon-based structure that are bio-compatible and present low toxicity. The research presents a new approach for the determination of thimerosal (preservative in vaccines and cosmetics) in influenza vaccines using GQDs as a modifier of the GC electrode and exploring the synergistic effect between GQDs, visible radiation and the applied potential difference. This system promotes thiomersal oxidation, producing a significant increase in response (Hg/Hg2 positive redox pair) in terms of current intensity using SWV and BR buffer (0.02 mol L-1; pH 4.00 with KCl at 0.25 mol L-1). The LOD was 0.85 μmol L-1 with linear dynamic range covering three orders of magnitude (10-6 to 10-4 mol L-1). For creatinine, a biomarker for the renal dysfunction, a GQDs-copper composite was used to modify a gold electrode. Determination of creatinine was made using SWV (BR buffer 0.02 mol L-1; pH 4.00 with KCl at 0.25 mol L-1). The method relied on the decreasing of the Cu2+/Cu oxidation peak in the presence of creatinine, enabling LOD of 50 nmol L-1 and linear dynamic range covering three orders of magnitude (10-6 to 10-4 mol L-1). The SWV response of creatinine was attributed to the formation of creatinine-Cu2 positive complex being reasonably selective towards this analyte. All procedures developed by voltammetry were adequately compared with reference methods, being statistically compatible.

Page generated in 0.0827 seconds