• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo da resistência às forças de cisalhamento de três sistemas condicionantes indicados para a colagem de acessórios ortodônticos /

Bertoz, André Pinheiro de Magalhães. January 2004 (has links)
Orientador: Eduardo César Almada Santos / Resumo: Os recentes materiais de colagem dos acessórios ortodônticos têm visado reduzir o tempo de trabalho do clínico, simplificando o procedimento do condicionamento ácido por meio dos sistemas adesivos autocondicionantes. Todavia, as qualidades adesivas desses materiais ainda demandam ser avaliada. Assim, o presente estudo objetivou avaliar a resistência às forças de compressão de três sistemas adesivos. Cento e oitenta incisivos inferiores bovinos foram seccionados e incluídos em matrizes de resina acrílica, nos quais acessórios ortodônticos foram colados com os sistemas Transbond XT (2 grupos de 30), Transbond XT Plus Self Etching Primer (2 grupos de 30) e Tyrian (2 grupos de 30). Para cada sistema, os testes de resistência foram realizados imediatamente (30 dentes) e 24 horas (30 dentes) após a colagem, em uma máquina de ensaio Versat 2000 (Pantec), utilizando célula de carga de 500 Kgf com uma velocidade de 1mm/minuto, de acordo com a literatura. Os sistemas convencional Transbond XT, Transbond XT Self Etching Primer e Tyrian apresentaram, respectivamente, valor médio de resistência à compressão de 7,43, 7,09 e 3,41 MPa no tempo imediatamente após a colagem, e 7,42, 8,81, 5,35 MPa no tempo 24 horas após a colagem, sendo as diferenças estatísticas significantes ao nível de 5% entre os grupos Tyrian e Transbond para ambos os tempos de estudo. Concluiu-se que o material Tyrian apresentou resistência à compressão significativamente inferior em relação aos grupos Transbond que foram similares. / Abstract: Recent orthodontic bonding materials have aimed to reduce the working time of the clinician, by simplifying the acid etching procedure by applying self-etching primer adhesive systems. However, the adhesion quality of these materials still demands investigation. Thus, the present study aimed to evaluate the bond strengths of three different adhesive systems. A hundred and eighty bovine lower incisors were cut and embebbed in acrylic resin matrices, in which orthodontic brackets were bonded with Transbond XT (2n = 60), Transbond XT Self Etching Primer (2n = 60) e Tyrian (2n = 60). For each composite, bond strength tests were executed immediately (n = 30) and 24 hours (n = 30) after the bonding, in the assay machine Versat 2000 (Pantec), by applying 500 Kgf of load at 1mm/min of velocity. Transbond XT, Transbond XT Self Etching Primer and Tyrian presented, respectively, average values of bond strength of 7.43, 7.09 and 3.41 MPa at the time immediately, and 7.42, 8.81 and 5.35 MPa at 24 hours after the bonding, where differences were statistically significant at 5% between Tyrian and Transbond groups at both observation times. It was concluded that Tyrian was the material that presented significant lower bond strength with regard to Transbond groups that were similar. / Mestre
2

Influencia dos metodos de secagem da dentina na resistencia ao cisalhamento de sistemas adesivos

Pereira, Gisele Damiana da Silveira 24 June 1999 (has links)
Orientador: Luis Alexandre Maffei Sartini Paulillo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T05:36:54Z (GMT). No. of bitstreams: 1 Pereira_GiseleDamianadaSilveira_M.pdf: 6881862 bytes, checksum: 025b37d2970888f849e6c9a21a3db961 (MD5) Previous issue date: 1999 / Resumo: O objetivo deste estudo foi avaliar a influência dos métodos de secagem da dentina na resistência às forças de cisalhamento de dois sistemas adesivos dentinários. Foram utilizadas as superfícies vestibular, lingual ou palatina em dentina de 105 terceiros molares íntegros recém-extraídos e armazenados em solução de formol a 10% com pH neutro. Após o condicionamento com ácido fosfórico a 35% por 15 segundos e lavagem com jatos de água por 20 segundos, foram empregados sete métodos de secagem dentinária: jatos de ar por 30 segundos (grupos 1 e 2); jatos de ar por 5 segundos (grupos 3 e 4); sem secagem (dentina sobremolhada, grupos 5 e 6); bolinhas de algodão seco (grupos 7 e 8); bolinhas de algodão úmido (grupos 9 e 10); esponja (pincel tipo "microbrush", grupos 11 e 12) e papel absorvente (grupos 13 e 14). Em seguida, o sistema adesivo Prime & Bond 2.1 foi aplicado nos grupos ímpares e nos grupos pares utilizou-se o sistema adesivo Scotchbond Multi Uso. Cilindros com 3mm de diâmetro e 5 mm de altura foram confeccionados com a resina composta Z-100 na área delimitada para a adesão, obtendo um total de 210 corpos-de-prova. Após 7 dias de armazenamento em ambiente a 37 'GRAUS'C com 100% de umidade relativa, os corpos-de-prova foram submetidos ao ensaio de resistência ao cisalhamento a uma velocidade de 0,5 mm/min. O teste t-Student apontou os resultados: Grupo 9= 23,2 MPa (a), Grupo 3= 21,3 MPa (ab), Grupo 2= 19,5 MPa (bc), Grupo 10= 18,6 MPa (bc), Grupo 14= 16,3 MPa (cd), Grupo 8= 16,1 MPa (cd), Grupo 4= 14,6 MPa (de), Grupo 13= 14,0 MPa (de), Grupo 11= 13,9 MPa (de), Grupo 7= 13,5 MPa (de), Grupo 12= 12,1 MPa (e), Grupo 1= 8,2 MPa (f), Grupo 5= 2,7 MPa (g), Grupo 6= 2,4 MPa (g). Através da análise estatística concluiu se que os valores de adesão para o sistema Prime & Bond 2.1 foram estatisticamente maiores quando esse adesivo foi aplicado nas superfícies dentinárias deixadas úmidas pelo método de secagem. Por outro lado, médias satisfatórias de resistência ao cisalhamento. para o sistema Scotchbond Multi Uso foram obtidas quando este foi aplicado ao substrato seco, contudo, esses valores não apresentaram diferença estatística significativa para os resultados dos grupos onde a dentina permaneceu; mais úmida após sua secagem. Ambos os adesivos apresentaram uma menor resistência adesiva quando aplicados ao substrato sobremolhado, onde nenhum método de secagem foi empregado / Abstract: The aim of the present study was to evaluate the shear bond strength of two adhesive systems when applied to dentin with different degrees of wetness. Buccal, lingual and palatine surfaces of 105 intact third molars recently extracted and stored in 10% formaline were utilized. After conditioning with 35% acid phosphoric for 15 seconds, seven methods of drying dentine substrate were used: Air spray for 30 seconds (Groups 1 and 2); air spray for 5 seconds (Groups 3 and 4); dry cotton pellets (Groups 7 and 8); wet cotton pellets (Groups 9 and 10); sponge (microbrush) (Groups 11 and 12); facial tissue (Groups 13 and 14); and the last group was not dried and the surfaces were left overwet (Groups 5 and 6). Thereafter, the Prime & Bond 2.1 System was applied in odd groups and the Scotchbond Multi Purpose was used in pair groups. Z-100composite cilinders with 3 mm diameter and 5mm height were built in the adhesive area (n=210). After seven days stored in a stove with 37 'DEGREE'C and 35% relative humidity, the especimens were submitted to the shear bond test in a 0,5 mm/min speed. The t-Student test presented the following results: Group 9=23.2 MPa (a); Group 3=21.3 MPa (ab); Group 2=19.5 MPa (bc); Group 10=18;6 MPa (bc); Group 14=16.3 MPa (cd); Group 8=16.1 MPa (cd); Group 4=14.6 MPa (de); Group 13=14.0 MPa (de); Group 11=13.9 MPa (de); Group 7=13.5 MPa {de}; Group 12=12.1MPa (e); Group 1-=8.2 MPa (f); Group 5=2.7 MPa (~); Group 6=2.4 MPa (g). Through the statistical analysis it was concluded that the adhesion values to Prime & Bond 2.1 were greater when this system was applied in a moister surface. On the other hand, the Scotchbond Multi Purpose showed good results to both wet and dry surfaces. The lower shear bond strength values were obtained when both adhesives were applied in a overwet surface, where the water excess was not removed. / Mestrado / Mestre em Clínica Odontológica
3

Estudo da resistência às forças de cisalhamento de três sistemas condicionantes indicados para a colagem de acessórios ortodônticos

Bertoz, André Pinheiro de Magalhães [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T20:36:31Z : No. of bitstreams: 1 bertoz_apm_me_araca.pdf: 3969582 bytes, checksum: bceb452a18ac260c5d9321687a89fc4b (MD5) / Os recentes materiais de colagem dos acessórios ortodônticos têm visado reduzir o tempo de trabalho do clínico, simplificando o procedimento do condicionamento ácido por meio dos sistemas adesivos autocondicionantes. Todavia, as qualidades adesivas desses materiais ainda demandam ser avaliada. Assim, o presente estudo objetivou avaliar a resistência às forças de compressão de três sistemas adesivos. Cento e oitenta incisivos inferiores bovinos foram seccionados e incluídos em matrizes de resina acrílica, nos quais acessórios ortodônticos foram colados com os sistemas Transbond XT (2 grupos de 30), Transbond XT Plus Self Etching Primer (2 grupos de 30) e Tyrian (2 grupos de 30). Para cada sistema, os testes de resistência foram realizados imediatamente (30 dentes) e 24 horas (30 dentes) após a colagem, em uma máquina de ensaio Versat 2000 (Pantec), utilizando célula de carga de 500 Kgf com uma velocidade de 1mm/minuto, de acordo com a literatura. Os sistemas convencional Transbond XT, Transbond XT Self Etching Primer e Tyrian apresentaram, respectivamente, valor médio de resistência à compressão de 7,43, 7,09 e 3,41 MPa no tempo imediatamente após a colagem, e 7,42, 8,81, 5,35 MPa no tempo 24 horas após a colagem, sendo as diferenças estatísticas significantes ao nível de 5% entre os grupos Tyrian e Transbond para ambos os tempos de estudo. Concluiu-se que o material Tyrian apresentou resistência à compressão significativamente inferior em relação aos grupos Transbond que foram similares. / Recent orthodontic bonding materials have aimed to reduce the working time of the clinician, by simplifying the acid etching procedure by applying self-etching primer adhesive systems. However, the adhesion quality of these materials still demands investigation. Thus, the present study aimed to evaluate the bond strengths of three different adhesive systems. A hundred and eighty bovine lower incisors were cut and embebbed in acrylic resin matrices, in which orthodontic brackets were bonded with Transbond XT (2n = 60), Transbond XT Self Etching Primer (2n = 60) e Tyrian (2n = 60). For each composite, bond strength tests were executed immediately (n = 30) and 24 hours (n = 30) after the bonding, in the assay machine Versat 2000 (Pantec), by applying 500 Kgf of load at 1mm/min of velocity. Transbond XT, Transbond XT Self Etching Primer and Tyrian presented, respectively, average values of bond strength of 7.43, 7.09 and 3.41 MPa at the time immediately, and 7.42, 8.81 and 5.35 MPa at 24 hours after the bonding, where differences were statistically significant at 5% between Tyrian and Transbond groups at both observation times. It was concluded that Tyrian was the material that presented significant lower bond strength with regard to Transbond groups that were similar.
4

Asfaltová souvrství s využitím sklovláknitých kompozitních materiálů / Asphalt Layers using Fibreglass Composite Materials

Sadil, Dominik Unknown Date (has links)
The diploma thesis deals with using of reinforcing composite materials in asphalt layers. These geosynthetic materials are in road construction used especially to reduce spreading cracks and extend the service life of the construction. As par of this work, test specimens of different types of asphalt layers were produced. These samples were subjected to laboratory testing, where the results of different reinforced asphalt slabs were compared. Within the diploma thesis primarily deals with the testing of the shear bond strength between asphalt layers in order to determine what are the other influencing factors of the test. Another part of the thesis is the 4-point bending test, during which a special technology in the form of a DIC camera was used to monitor the behavior of the asphalt layer over time.

Page generated in 0.0922 seconds