Spelling suggestions: "subject:"shortcircuit fault"" "subject:"shortcircuit fault""
1 |
Energy Management in More Electric Aircraft through PMSM Fault Diagnosis, Adaptive Load Shedding and Efficient Aircraft DesignGe, Yuxue 03 June 2019 (has links) (PDF)
More electric aircraft is an electrification scheme of aircraft system with high technical feasibility and good economy. It can reduce the weight of aircraft structure, improve maintenance efficiency and reduce fire hazards. However, the electrification of aircraft system will drastically increase the proportion of electrical equipment, the total power demand and the difficulty of fault diagnosis. This paper uses the energy management method to take up the challenge, with focus on fault diagnosis of permanent-magnet synchronous machines (PMSMs), adaptive load shedding and energy efficient aircraft design. A literature review of the concept evolution from all/more-electric aircraft to energy-optimized aircraft is presented. The main issues of the aircraft electrification process are summarized, and followed by an introduction to the current research and methods. The model of the aircraft electrical system is qualitatively and mathematically recalled, including the generator, the battery, the DC motor, the AC motor, and the electric power converter. The accuracy and computation cost of the aircraft model depends on the complexity of the subsystem models that are involved. Therefore, the level of detail that is necessary for a good precision-versus-simulation-time ratio is discussed by taking the electric system of an industrial level hybrid energy quadcoptor UAV as an example. The analysis shows that the bi-directional instruments, i.e. the electric machine, should be modeled in details while other components can be simplified. PMSMs are a group of on-board electric machines with promising future prospects because of high power density and stability. The model of PMSMs is further developed in this work, especially in the inter-turn and phase-to-phase short-circuit conditions. In case of inter-turn short-circuit fault, a winding-function-based and a fault-current-based model are separately developed. The accuracy of both models are verified and compared through experimental results. The fault-current-based modeling method is applied to the phase-to-phase short-circuit fault and experimentally examined and discussed. General condition monitoring methods require the use of a large number of sensors. A fault detection and isolation method that can have low requirement of sensor is recalled and inherited. The description of the fault phase identification index using this method is relatively imprecise, which is not applicable to the inter-turn short-circuit fault. In this work, the analytical expression of the faulty phase identification index is derived based on the fault models. A method to isolate inter-turn and phase-to-phase short-circuit faults is proposed by a combination of the current- and the voltage-signature residuals. This development expands the application scope of the original fault detection and isolation tool and improves its accuracy. The validity of this fault diagnosis method has been verified by experimental results.Load management is developed to guarantee the normal operation of critical loads by shedding some other loads in case of emergency. Generally, binary decisions are made: either something has gone wrong or everything is fine. However, different types of fault influence the working performance of the load and the entire network in different ways. There are multiple states between totally wrong and pure fine, and the load management decision should be adaptive to each state. In this work, fuzzy logic method is used to degrade the load priority according to the instantaneous working state. Combining it with the fault detection and isolation process, a fault-tolerant adaptive load management is achieved. Finally, this work discusses the aircraft design from the energy management point of view, which consists of the energy efficiency analysis and the multidisciplinary energy efficient design of the integrated aircraft system. The first thermodynamic efficiency has been widely used as a common parameter for depicting the energy utilization, i.e. the ratio of output to input power of the system. However, it ignores the irreversible increase of the entropy and cannot reveal the upper limit of the available work of the system.Based on the second thermodynamic law, this work uses the exergy parameters to analyze the energy utilization of a MEA design scheme. Based on the exergy analysis, an energy-efficient aircraft design method is proposed by optimizing the exergy lost of the whole design. The method could provide a global optimization reference for the integrated aircraft design of a MEA. / Doctorat en Sciences de l'ingénieur et technologie / info:eu-repo/semantics/nonPublished
|
2 |
Fault Diagnosis for Lithium-ion Battery System of Hybrid Electric Aircraft.Cheng, Ye 24 August 2022 (has links)
No description available.
|
3 |
Identification de défauts dans les convertisseurs statiques DC/DC à composants SiC destinés aux applications pile à combustible / Fault identification in static DC/DC converters with SiC components for fuel cell applicationsYahyaoui, Rabeb 27 June 2018 (has links)
L’utilisation des convertisseurs de puissance dans les applications de transport électrique à base de pile à combustible ouvre les portes de recherche sur la problématique de leur fiabilité puisqu’un défaut dans ces circuits pourrait provoquer une panne ou un disfonctionnement se répercutant sur l’ensemble de la chaine de traction. Le convertisseur statique considéré est un hacheur élévateur à six bras parallèles et entrelacés à fréquence de découpage égale à 100kHz ayant un gain en tension élevé (égal à 5). Il comporte avec le choix des éléments passifs une ondulation de courant d’entrée faible et interface une pile à combustible de 21kW (70V, 300A) et une charge résistive de 350V (valeur proche des réseaux comportant des batteries Li-ion). Ces systèmes incorporent des interrupteurs de puissance semi-conducteurs qui sont les composants les plus fragiles et qui sont soumis à des contraintes électriques et thermiques sévères pour les applications automobiles. L’utilisation de la technologie en carbure de silicium pour ces cellules semi-conductrices élémentaires accompagne un réel besoin industriel des filières de développement des systèmes miniaturisés et intègre les préoccupations des constructeurs automobiles autour de la mise en œuvre opérationnelles des technologies innovantes embarquées et fiables. En effet, cette technologie des composants semi-conducteurs, dit «grand-gap», est à coup sûr un candidat sérieux pour optimiser l’efficacité énergétique et l’intégration de puissance des convertisseurs, pour pile à combustible, plus robustes vis-à-vis des contraintes de l’usage transport. Dans mes travaux de thèse, les défauts de type court-circuit et circuit-ouvert d’interrupteurs de puissance en carbure de silicium sont alors considérés pour satisfaire la continuité de service et annuler l’influence de cette dégradation d’une part sur la source électrochimique et d’autre part sur la charge. Les méthodes de détection proposées sont des méthodes simples et non intrusives. Elles utilisent la tension drain et source VDS de l’interrupteur de puissance comme indicateur de défaut pour juger de la présence d'un court-circuit ou un circuit-ouvert. Le principe de détection consiste à comparer la tension VDS à une tension seuil paramétrable (à fixer pour le composant en carbure de silicium). Une fois la phase inductive défectueuse est identifiée, un processus de de gestion des défauts par la commande est mis en œuvre. Dans le cas de court-circuit une stratégie de soulagement par la commande est appliquée pour adoucir la coupure de courant de la branche inductive en défaut. Puis suivra l’isolation de cette ligne via des interrupteurs spécifiques qui supportent une ouverture du circuit à fort courant (exemple: fusible ultra-rapide) et une reconfiguration par la commande du convertisseur de puissance (passage de 6 à 6-i phases, avec i nombre de défauts). Dans le cas de circuit-ouvert, qui un défaut qui isole automatiquement le bras défectueux, si aucune action préventive n’est planifiée la continuité de service est assurée mais à plus d’ondulations de courant sur les bras du convertisseur statique. Pour éviter cet effet, la reconfiguration par la commande est nécessaire. / The use of power converters in fuel cell electrical transport applications drives research to study the problem of their reliability, since a fault in these circuits could cause a breakdown or a malfunction that affects the entire system of the powertrain. The converter under consideration is a six-phase interleaved boost converter operating in unidirectional power flow in continuous conduction mode with a 100 kHz switching frequency and a high voltage gain (equal to 5). It allows, with the choice of passive elements, a low input current ripple and interfaces a 21kW fuel cell (70V, 300A) and a resistive load of 350V (value close to the networks with batteries Li-ion). These systems contain semiconductor power switches which are the most fragile components and are subject to severe electrical and thermal stresses for automotive applications. The use of silicon carbide technology for these semiconductor components accompanies a real industrial need for development of a miniaturized system and integrates the concerns of manufacturers of electric vehicles around the implementation of innovative, embedded and reliable technologies. Indeed, this technology of semiconductor components is certainly a serious candidate to optimize the energy efficiency and power integration of converters, for fuel cells, more robust against constraints of the transport use. In my thesis work, switch short-circuit and switch open-circuit faults of silicon carbide power switches are considered to satisfy the continuity of service and to cancel the influence of this degradation on both the fuel cell source and the charge. The proposed detection methods are simple and non-intrusive. They use the drain to source voltage VDS of the power switch as a fault indicator to judge the presence or not of a short-circuit or an open-circuit switch fault. The detection principle consists in comparing the VDS voltage with a configurable threshold voltage (to fix it for the silicon carbide component). Once the faulty inductive phase is identified, a fault management process by the control is implemented. In the case of switch short-circuit fault, firstly a control strategy is applied to soften the break of current of the faulty inductive phase. After faulty phase isolation using specific switches that support breaking of the high-current circuit (example: high-speed fuse) and a reconfiguration by the control of the power converter (transition from 6 to 6-i phases, with i number of faults). In the case of switch open-circuit fault, which automatically isolates the defective phase, if any preventive action is planned the continuity of service is ensured but to more current ripple on the arms of the DC/DC converter. To avoid this effect, reconfiguration by the command is necessary.
|
4 |
Contribution au Diagnotic des Défauts de la Machine Asynchrone Doublement Alimentée de l'Eolienne à Vitesse Variable. / Fault diagnosis of a Doubly Fed Induction Generator (DFIG) in a variable speed wind turbineIdrissi, Imane 21 September 2019 (has links)
Actuellement, les machines Asynchrones à Double Alimentation (MADA) sont omniprésentes dans le secteur éolien, grâce à leur simplicité de construction, leur faible coût d’achat et leur robustesse mécanique ainsi que le nombre faible d’interventions pour la maintenance. Cependant, comme toute autre machine électrique, ces génératrices sont sujettes aux défauts de différent ordre (électrique, mécanique, électromagnétique…) ou de différents types (capteur, actionneur ou composants du système). C’est pourquoi, il est primordial de concevoir une approche de diagnostic permettant de manière anticipée, de détecter, localiser et identifier tout défaut ou anomalie pouvant altérer le fonctionnement sain de ce type de machine. Motivés par les points forts des méthodes de diagnostic de défauts à base d’observateurs, nous proposons d’une part, dans cette thèse, une approche de détection, localisation et identification des défauts de la MADA d’une éolienne à vitesse variable, à base des observateurs de Kalman, performants et largement utilisés. Les erreurs d’estimation d’état du filtre de Kalman linéaire et de ses variantes non-linéaires, à noter : le Filtre de Kalman Etendu (EKF) et le Filtre de Kalman sans-Parfum (UKF), sont utilisés comme résidus sensibles aux défauts. En vue d’éviter les fausses alarmes et de découpler les défauts des perturbations et des bruits, l’analyse des résidus générés est réalisée par des tests statistiques tels que : Test de Page Hinkley (PH) et Test DCS (Dynamic Cumulative Sum). Pour la localisation des défauts multiples et simultanés, la Structure d’Observateurs Dédiés (DOS) et la Structure d’Observateurs Généralisés (GOS) sont appliquées. De plus, l’amplitude du défaut est déterminée dans l’étape d’identification de défaut. Les défauts capteurs, actionneurs et composants de la MADA, sont traités dans ce travail de recherche. D’autre part, une étude comparative entre les différents observateurs de Kalman, est élaborée. La comparaison porte sur les critères suivants : le temps de calcul, la précision et la vitesse de convergence des estimations. / Actually, the Doubly Fed Induction Generators (DFIG) are omnipresent in the wind power market, owing to their construction simplicity, their low purchase cost and their mechanical robustness. However, as any other electrical machine, these generators are subject to defects of different order (electrical, mechanical, electromagnetic ...) or of different type (sensor, actuator or system). That’s why, it is important to design an effective diagnostic approach, able to early detect, locate and identify any defect or abnormal behavior, which could undermine the healthy operation of this machine On the one hand, motivated by the observer-based fault diagnosis methods strengths, we proposed, in this thesis, a diagnostic approach for the faults detection, localization and identification of the DFIG used in variable speed wind turbine. This approach is based on the use of the efficient and widely used Kalman observers. The state estimation errors of the linear Kalman filter and the non-linear Kalman filters, named: The Extended Kalman Filter (EKF) and the Unscented Kalman Filter (UKF) are used as faults sensitive residuals. In order to avoid false alarms and to decouple faults from disturbances and noises, the faults detection is carried out by the analysis of the residuals generated, by the mean of statistical tests such as: Hinkley Page Test (PH) and DCS Test (Dynamic) Cumulative Sum). For the localization step in case of multiple and simultaneous faults, the Dedicated Observer scheme (DOS) and the Generalized Observer scheme (GOS) are applied. In addition, the fault level is determined in the fault identification step. Sensor faults, actuator and system faults of DFIG, are treated in this research work. On the other hand, a comparative study between the three Kalman observers proposed is performed. The comparison was done in terms of (1) the computation time, (2) the estimation accuracy, and (3) the convergence speed.
|
5 |
Robustní řízení synchronního stroje s permanentními magnety a spínaným tokem / Fault-Tolerant Control of a Flux-switching Permanent Magnet Synchronous MachineAboelhassan, Mustafa Osman Elrayah January 2013 (has links)
Je jasné, že nejúspěšnější konstrukce zahrnuje postup vícefázového řízení, ve kterém každá fáze může být považována za samostatný modul. Provoz kterékoliv z jednotek musí mít minimální vliv na ostatní, a to tak, že v případě selhání jedné jednotky ostatní mohou být v provozu neovlivněny. Modulární řešení vyžaduje minimální elektrické, magnetické a tepelné ovlivnění mezi fázemi řízení (měniče). Synchronní stroje s pulzním tokem a permanentními magnety se jeví jako atraktivní typ stroje, jejíž přednostmi jsou vysoký kroutící moment, jednoduchá a robustní konstrukce rotoru a skutečnost, že permanentní magnety i cívky jsou umístěny společně na statoru. FS-PMSM jsou poměrně nové typy střídavého stroje stator-permanentní magnet, které představují významné přednosti na rozdíl od konvenčních rotorů - velký kroutící moment, vysoký točivý moment, v podstatě sinusové zpětné EMF křivky, zároveň kompaktní a robustní konstrukce díky umístění magnetů a vinutí kotvy na statoru. Srovnání výsledků mezi FS-PMSM a klasickými motory na povrchu upevněnými PM (SPM) se stejnými parametry ukazuje, že FS-PMSM vykazuje větší vzduchové mezery hustoty toku, vyšší točivý moment na ztráty v mědi, ale také vyšší pulzaci díky reluktančnímu momentu. Pro stroje buzené permanentními magnety se jedná o tradiční rozpor mezi požadavkem na vysoký kroutící moment pod základní rychlostí (oblast konstantního momentu) a provozem nad základní rychlostí (oblast konstantního výkonu), zejména pro aplikace v hybridních vozidlech. Je předložena nová topologie synchronního stroje s permanentními magnety a spínaným tokem odolného proti poruchám, která je schopná provozu během vinutí naprázdno a zkratovaného vinutí i poruchách měniče. Schéma je založeno na dvojitě vinutém motoru napájeném ze dvou oddělených vektorově řízených napěťových zdrojů. Vinutí jsou uspořádána takovým způsobem, aby tvořila dvě nezávislé a oddělené sady. Simulace a experimentální výzkum zpřesní výkon během obou scénářů jak za normálního provozu, tak za poruch včetně zkratových závad a ukáží robustnost pohonu za těchto podmínek. Tato práce byla publikována v deseti konferenčních příspěvcích, dvou časopisech a knižní kapitole, kde byly představeny jak topologie pohonu a aplikovaná řídící schémata, tak analýzy jeho schopnosti odolávat poruchám.
|
Page generated in 0.0445 seconds