• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 5
  • 5
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Communications optiques sous-marines : transmission longue-portée haut débit et analyse des performances / Underwater Wireless Optical Communications : Long-range High-data-rate Transmission and Performance Analysis

Hamza, Tasnim 23 March 2017 (has links)
Aujourd'hui, un large éventail d'activités d'exploration et d'exploitation du milieu sous-marin requière l'établissement de transmissions de données à haut débit. Dans ce contexte, les solutions de communications traditionnelles par câble ou par fibre optique impliquent des déploiements coûteux et une flexibilité très limitée. D'autre part, les communications acoustiques offrent des performances opérationnelles très faibles. Récemment, avec le développement de composants optoélectroniques compacts et peu coûteux, il est devenu possible de réaliser des modems optique pour les communications sans-fil, qui soient compacts et offrent des vitesses de transmission et une efficacité énergétique sans précédentes. Cependant, cette technologie souffre encore de plusieurs limitations, notamment quand il s'agit d'établir des liens de communication sur des distance relativement longues et à des débits de transmission élevés. Pour faire face à certaines de ces faiblesses, cette thèse considère l'utilisation de nouveaux composants optoélectroniques et des techniques de traitement du signal adaptées afin d'améliorer les performances des liaisons de communication optique sans fil sous-marine.En effet, après l'étude de l'effet du bruit solaire sur la performance de ces liaisons, nous étudions l'utilisation d'une nouvelle technologie de photo détection, basée sur les photomultiplicateurs en silicium (SiPM). Nous étudions les performances de ces composants dans différentes conditions de turbidité de l'eau. Par ailleurs, nous proposons des techniques de transmission efficaces basées principalement sur la modulation d'amplitude et l'égalisation dans le domaine fréquentiel. Cette dernière est employée afin de dépasser la limitation imposée sur les débits de transmission par les composants d'émissions et de réception, notamment les LEDs et les SiPMs, et ainsi permettre une transmettre les données à des débits plus élevés. L'efficacité des solutions proposées est ensuite validée par une étude expérimentale. / Today we are witnessing a growing need to high-rate data transmission in underwater missions in a wide range of application areas. Within this context, traditional cable- or fiber-based communications imply costly deployments with very limited flexibility, and the conventional acoustic communications offer very low operational performance. Recently, with the development of small and low-cost optoelectronic components and devices, it has become feasible to realize small and compact wireless optical communication transceivers providing unprecedentedly high transmission rates and energy efficiency. However, there still remain several shortcomings of this technology, in particular to attain high data rates over relatively long communication ranges. In order to overcome some of these limitations, this PhD thesis considers the use of advanced optoelectronic components and signal processing techniques in order to improve the performance of underwater wireless optical communication (UWOC) links. In this view, after studying the effect of solar background noise on the performance of these links, we investigate the use of the recent promising Silicon photo-multipliers (SiPMs) in UWOC receivers and study the corresponding system performance in different conditions of water turbidity. We also propose efficient transmission solutions, mainly based on pulse amplitude modulation and frequency domain equalization in order to surpass the bandwidth limitation of the emitters and SiPMs to allow high rate data transmission. The benefits of the proposed solutions are further validated through experimental measurements.
2

Αξιολόγηση φωτοπολλαπλασιαστών πυριτίου (SiPMs) ως ανιχνευτές υβριδικών απεικονιστικών συστημάτων πυρηνικής ιατρικής

Αργυρόπουλος, Ιωάννης 11 January 2011 (has links)
Οι φωτοπολλαπλασιαστές Πυριτίου (Silicon Photomultipliers, SiPMs) είναι ελκυστικοί υποψήφιοι για την αντικατάσταση των φωτοπολλαπλασιαστών στην πυρηνική ιατρική απεικόνιση. Οι SiPMs είναι συμπαγείς και μικρού μεγέθους, εξασφαλίζουν υψηλό κέρδος με χαμηλή τάση πόλωσης, ενώ έχουν γρήγορη απόκριση. Επιπλέον, δεν επηρεάζονται από τα ισχυρά μαγνητικά πεδία, γεγονός που επιτρέπει τη χρήση τους στο γοργά αναπτυσσόμενο πεδίο του PET-MRI. Ωστόσο, η ανάπτυξη πρωτότυπων μικρών ανιχνευτικών διατάξεων που βασίζονται στους SiPMs παρουσιάζει μεγάλες σχεδιαστικές απαιτήσεις, εφόσον είναι απαραίτητη η αποδοτική σύζευξη του σπινθηριστή και του SiPM, όπως επίσης και η βελτιστοποίηση της ενίσχυσης και ψηφιοποίησης του σήματος. Σε αυτή την εργασία εξετάστηκε η λειτουργικότητα τριών βασικών μονάδων SiPM της εταιρίας SensL κατά τη σύζευξή τους με διάφορους ανιχνευτές σπινθηρισμού, κατάλληλους για συστήματα SPECT και PET. Ως ραδιενεργές πηγές χρησιμοποιήθηκαν τα ισότοπα 99mTc, 111In και 18F. Το σύστημα ανάγνωσης-επεξεργασίας των λαμβανόμενων σημάτων απαρτίζεται από ένα κύκλωμα προενισχυτή της εταιρίας SensL, ενισχυτή και ADC τύπου ΝΙΜ καθώς και το λογισμικό MPA/WIN, το οποίο διαβάζει δεδομένα από μια κάρτα PCI. Οι παράμετροι που μετρήθηκαν είναι το σχήμα του εξερχόμενου παλμού, ο ρυθμός σκότους (Dark Count Rate, DCR), η ανιχνευτική ικανότητα, η γραμμικότητα και η ενεργειακή διακριτική ικανότητα του συστήματος για διαφορετικές τάσεις πόλωσης (Vbias) και ενέργειες φωτονίων γ. Η βέλτιστη ενεργειακή διακριτική ικανότητα για την ενέργεια των 511 keV ήταν 11%, η οποία αυξάνεται στο 23% για ενέργεια 140 keV. Η τάση πόλωσης επηρεάζει ισχυρά το πλάτος του εξερχόμενου παλμού, ενώ η διάρκεια του παλμού παρουσίασε μικρότερες διακυμάνσεις. Η σχετικά αργή χρονική απόκριση των ενισχυτών NIM περιόρισε τη δυνατότητα μετρήσεων σε όλους τους διαθέσιμους σπινθηριστές, αλλά έδωσε το κίνητρο του σχεδιασμού και της κατασκευής στο εργαστήριο νέων κατάλληλων κυκλωμάτων ενίσχυσης και ψηφιοποίησης γρήγορων παλμών. / Silicon Photomultiplier (SiPMs) detectors are attractive candidates for the replacement of Photomultipliers in nuclear imaging. They are compact, they provide high gain with low bias voltage and have fast response. In addition strong magnetic fields don’t influence them, which allows their use in the emerging field of PET-MRI. The development of small prototypes based on SiPMs has several design challenges, since it is necessary to optimize scintillator and SiPM coupling, as well as signal amplification and digitization. In this work we have investigated the performance of three basic SiPM modules constructed by SensL corporation coupled to various scintillator detectors, suitable for SPECT and PET systems. The radioactive sources that we used were 99mTc, 111In and 18F. The readout system includes the SensL preamplifier circuit, a NIM amplifier and ADC and MPA/WIN software. The parameters that have been measured are output pulse shape, dark count rate (DCR), detection efficiency, linearity and energy resolution for different bias voltages (Vbias) and energies. Best energy resolution for 511keV was 11% and was increased to 23% for 140keV. Vbias strongly affects output pulse amplitude, while time duration has smaller variations. The performance of a custom amplifier is presented and further optimizations in readout electronics are discussed.
3

Development of a Silicon Photomultiplier Based Gamma Camera

Tao, Ashley T. 04 1900 (has links)
<p>Dual modality imaging systems such as SPECT/CT have become commonplace in medical imaging as it aids in diagnosing diseases by combining anatomical images with functional images. We are interested in developing a dual modality imaging system combining SPECT and MR imaging because MR does not require any ionizing radiation to image anatomical structures and it is known to have superior soft tissue contrast to CT. However, one of the fundamental challenges in developing a SPECT/MR system is that traditional gamma cameras with photomultiplier tubes are not compatible within magnetic fields. New development in solid state detectors has led to the silicon photomultiplier (SiPM), which is insensitive to magnetic fields.</p> <p>We have developed a small area gamma camera with a tileable 4x4 array of SiPM pixels coupled with a CsI(Tl) scintillation crystal. A number of simulated gamma camera geometries were performed using both pixelated and monolithic scintillation crystals. Several event positioning algorithms were also investigated as an alternative to conventional Anger logic positioning. Simulations have shown that we can adequately resolve intrinsic spatial resolution down to 1mm, even in the presence of noise. Based on the results of these simulations, we have built a prototype SiPM system comprised of 16 detection channels coupled to discrete crystals. A charge sensitive preamplifier, pulse height detection circuit and a digital acquisition system make up our pulse processing components in our gamma camera system. With this system, we can adequately distinguish each crystal element in the array and have obtained an energy resolution of 30±1 (FWHM) with Tc-99m (140keV). In the presence of a magnetic field, we have seen no spatial distortion of the resultant image and have obtained an energy resolution of 31±3.</p> / Master of Science (MSc)
4

Retrieving Information from Scattered Photons in Medical Imaging

Jha, Abhinav K. January 2013 (has links)
In many medical imaging modalities, as photons travel from the emission source to the detector, they are scattered by the biological tissue. Often this scatter is viewed as a phenomenon that degrades image quality, and most research is focused on designing methods for either discarding the scattered photons or correcting for scatter. However, the scattered photons also carry information about the tissue that they pass through, which can perhaps be extracted. In this research, we investigate methods to retrieve information from the scattered photons in two specific medical imaging modalities: diffuse optical tomography (DOT) and single photon emission computed tomography (SPECT). To model the scattering of photons in biological tissue, we investigate using the Neumann-series form of the radiative transport equation (RTE). Since the scattering phenomenon are different in DOT and SPECT, the models are individually designed for each modality. In the DOT study, we use the developed photon-propagation model to investigate signal detectability in tissue. To study this detectability, we demonstrate the application of a surrogate figure of merit, based on Fisher information, which approximates the Bayesian ideal observer performance. In the SPECT study, our aim is to determine if only the SPECT emission data acquired in list-mode (LM) format, including the scattered-photon data, can be used to compute the tissue-attenuation map. We first propose a path-based formalism to process scattered photon data, and follow it with deriving expressions for the Fisher information that help determine the information content of LM data. We then derive a maximum-likelihood expectation-maximization algorithm that can jointly reconstruct the activity and attenuation map using LM SPECT emission data. While the DOT study can provide a boost in transition of DOT to clinical imaging, the SPECT study will provide insights on whether it is worth exposing the patient to extra X-ray radiation dose in order to obtain an attenuation map. Finally, although the RTE can be used to model light propagation in tissues, it is computationally intensive and therefore time consuming. To increase the speed of computation in the DOT study, we develop software to implement the RTE on parallel computing architectures, specifically the NVIDIA graphics processing units (GPUs).
5

Development and evaluation of a small animal PET protype compatible with strong magnetic fields / Ανάπτυξη και αξιολόγηση πρωτότυπου συστήματος PET απεικόνισης μικρών ζώων συμβατού με ισχυρά μαγνητικά πεδία

Ευθυμίου, Νικόλαος 25 May 2015 (has links)
A valid definition of molecular imaging could be the noninvasive, real-time visualization of biochemical events at the cellular and molecular level within living cells, tissues, and/or intact subjects.The words molecular imaging mean different things to various groups, and thus the areas of research and medicine that fall under the umbrella of molecular imaging are incredibly vast and varied.Generally speaking, molecular imaging involves specialized instrumentation, used alone or in combination with targeted imaging agents, to visualize tissue characteristics and/or biochemical processes. The data provided from molecular imaging studies can be used to help understand biological phenomena, identify regions of pathology, and provide insight regarding the mechanisms of pathogens. The PET-MRI combination requires the implementation of four technologic achivements that influence current state-of-the-art PET and MRI. First, the photomultiplier technology must be replaced with magnetic field–insensitive avalanche photodiodes. Second, compact PET detectors must be constructed in such a way to be transparent to the MRI and so to not interfere with the field gradients or MR radiofrequency. Third, the MRI scanner must be adapted to accommodate the PET detectors and to allow simultaneous and concurrent data acquisition. Finally, investigation on the optimum reconstruction strategies to accompany such a system incorporating completely new procedures for PET attenuation correction, based solely on MRI information, have to be performed. The development of integrated PET-MRI is, therefore, a comprehensive endeavor that requires a significant advancement of PET detector technology, MRI system integration, and new software approaches. Historically, PET systems have generally developed as circular “rings”. The earliest tomographs consisted of few detectors that rotated and translated to obtain a complete set of projection data, but soon full ring systems were developed. Yet, dual head PET scanners, due to their smaller size, compact geometry and closer proximity to the source can provide optimum dedicated scanning. In other cases imaging can be performed where convensional full ring geometries cannot be used. The have been proven valuable tools in preclinical imaging and are emerging in clinical cases like in PEM (Positron Emission Mammography). For the current Ph.D. thessis a planar dual head PET system was used for the evaluation of the reconstruction algorithms as well as the validation of the simulation models. It was developed by the Detector and Imaging Group of the Thomas Jefferson National Accelerator Facility (USA) in collaboration with the Medical Instruments Technology dep. of the Technological Educational Institute of Athens and is currently installed at the Institute of Radioisotopes - Radiodiagnostic prod. at the National Center for Scientific Research “Demokritos”. The system has two planar detectors. Each head contains one Hamamatsu H8500 PSPMT with 50$\times$50 mm$^2$ active size; an LSO:Ce crystal array with 20x20 pixels, 2x2x10 mm^3 in size. The septa between the crystals are 0.2 mm. The two detector heads were mounted on a gantry made initially from wood and afterwards from plastic. The materials were selected for their magnetic tolerance and low cost. In addition, their construction allow the easy adjustment of the head separation distance according to the needs of the experiment. The minimum separation distance between the two heads can be 7 cm and the maximum 14 cm. Moreover, it is capable to accept two additional heads in order to support a quad head system. The system is able to provide images without rotation using the Focal Plane Tomography algorithm. While using step and shoot acquisition it can provide tomographic images based on the acquired planar projection data or data obtained in listmode format and sorted in 3D sinograms similar to cylindrical PET systems. Evaluation of the system under planar imaging showed that for head separation distance 5 cm, the system maintains its linear performance for activities up to 3.5 MBq, which is sufficient for mice applications. For larger separations distances this value is well above 4 MBq. It is fully capable of providing fast planar coincidence images as well as non-kinetic tomographic images using a step and shoot rotation. The main drawback of the rotating head approach remains of low sensitivity compared to the full-ring systems. The best spatial resolution, in the center of the FOV, is 2.5 mm in the planar mode and 1.9 mm in the tomographic mode. For head separation distances below 8 cm the FOV appears to be uniform in the central 4x4 cm^2 area in planar and in tomographic acquisitions. Further on the edges the sensitivity is reduced to the 10%. The performance of the system in imaging small animals, despite any limitations on the reconstruction, is considered satisfactory.Fast planar images, for pharmaceutical kinetic analysis, can be obtained. While using the rotating capabilities of the gantry, all the important anatomical structures are imaged in detail. The geometry of the prototype system was simulated using GATE 6.0. Two simulation models were implemented and validated. With and without the ^176Lu radioactivity, since the LSO intrinsic radioactivity is not included by default to GATE simulations. The two models were validated with reference experimental data in terms of dark count rate, count rate performance (cps) and scatter fraction (sf). In addition the effect of the low level discriminator (LLD) threshold on signal as well as image quality is compared to the effect of the software energy window. The intrinsic radioactivity concentration of the ^176Lu was found in literature as 277Bq/cm^3. The intrinsic activity was uniformly distributed within the volume of the crystal array, accounting for the septa volume between the crystals. Close investigation on the origin of the detected events in the simulated data, concluded that the use of high LLD thresholds and a wide energy window improves the sensitivity of the system in terms of NECR, since greater number of true events are detected while randoms and scatters are early rejected. Investigation on the SNR properties, using a additional water phantom,to approximate the small animal body, showed that the value peaks when the low energy window limit is at 350 keV. Below that limit the scatters are strongly increased and above a portion of the trues is rejected. The minimum detectable activity of the system was assessed to 12.4 KBq, under the aforementioned imaging conditions. Using a more complex phantom, rather than a capillary source, the minimum detectable activity is expected to take higher values. Simulation were carried out incorporating the influence of a static magnetic field. The results suggested great improvement on the minimum detectable activity, in the case were there is not sufficient medium around the source for positron annihilation. Hence, improvements on the detectability of small lesions in the lungs of near the skin, are to be expected in an PET/MR module. This is a positive side effect of the magnetic field which has not been stressed out in literature. In addition, the results showed that the spatial resolution of the system got improved, as expected. In order to address the limitations of the rotating planar reconstruction, STIR reconstruction toolkit was introduced. STIR is a well validated reconstruction toolkit providing the OSEM algorithm, accompanied with a great variety of applicable options and filters. For the current studies only OSEM with 2 iterations was used. Possible image improvements on the image quality with the use of filters and priors was out of the scopes of this thesis. In addition, a component based normalization technique and an attenuation correction approximation were applied during the reconstruction. In order to produce the normalization sinograms two different source were simulated. First, an ideal cylindrical source, covering the entire FOV for the extraction of the axial geometric factors and the detector efficiencies. Second, a planar rotating source in order to calculate the transverse geometric factors and crystal interference functions. For the calculation of the experimental PET's detector efficiencies an plastic planar source was constructed rotated mathematically around the FOV, in order to approximate the ideal cylindrical of the simulation. The components of the normalization were geometric (transverse and axial), detector efficiencies and crystal interference functions. The normalized reconstructed images images, simulated as well as experimental, demonstrate uniform sensitivity inside the FOV. The final, part of a small animal imaging PET system, compatible with strong magnetic fields, which was under investigation, was the part of the detector. Current trends lead to the SiPMs as the next generation of PET detectors due to the magnetic tolerance. SiPM detectors purchased from SensL were evaluated in terms of their output pulse and noise characteristics, photon detection efficiency and linearity over the bias voltage and the energy of the irradiating source. Two SiPM detectors were evaluated SPMM-3020 and SPMM-3035. The differences reside on the difference size, wherefore and total number, of SPAD elements. In order to overcome limitations on the manufacturer's electronics a custom amplifier was designed and implemented. The amplifier was able to condition the signals from both SiPM to be acquired correctly from the DAQ. SPMM-3020, which had more and smaller SPAD elements showed a more linear response under a wide variety of conditions ranging to different operational voltages to crystals with higher light output irradiated from sources with different γ-photon energy. In addition, under normal room temperature the noise propertied were superior over SiPM-3035. The results indicate that this detector would be the preferable choice for a SPECT system, which the imaging protocols require the linear and accurate detect many different $\gamma$-photon energies. SPMM-2035, which had less and larger SPAD elements displayed better energy resolution and a narrower but adjustable (through the operating voltage) linear area. The provided signal was higher, hence less amplification was demanded for it to be recorded, even after long transition though cables. These merits make it a suitable candidate for PET-MR scanners since in PET imaging the energy of the detected γ-photons is only 511 keV and the linear area can be adjusted according to the crystal's light output. / Ένας έγκυρος ορισμός της μοριακής απεικόνισης θα μπορούσε να είναι "η μη επεμβατική, σε πραγματικό χρόνο απεικόνιση των βιοχημικών γεγονότων σε κυτταρικό και μοριακό επίπεδο μέσα σε ζωντανά κύτταρα, ιστούς, ή/και άθικτα δοκίμια". Ο τίτλος της μοριακή απεικόνιση υπονοεί διαφορετικά πράγματα για διάφορες ομάδες και πεδία έρευνας, έτσι οι τομείς της έρευνας και της ιατρικής που εμπίπτουν κάτω από την ομπρέλα της μοριακής απεικόνισης είναι πολλοί και ποικιλόμορφοι. Γενικά μιλώντας, μοριακή απεικόνιση περιλαμβάνει εξειδικευμένα συστήματα, που χρησιμοποιούνται από μόνα τους ή σε συνδυασμό με στοχευμένους παράγοντες απεικόνισης, για να απεικονίσουν λειτουργικά χαρακτηριστικά κάποιων ιστών ή/και ενδοκυτταρικές βιοχημικές διεργασίες. Τα δεδομένα που παρέχονται από τις μελέτες μοριακής απεικόνισης μπορεί να χρησιμοποιηθούν για να βοηθήσουν στην κατανόηση των βιολογικών φαινομένων, να προσδιορίσουν παθολογικές καταστάσεις, και να παρέχουν πληροφορίες σχετικά με τους μηχανισμούς των παθολογικών παραγόντων. Τα πιο δημοφιλή κλινικά συστήματα που χρησιμοποιούνται στην μοριακή απεικόνιση είναι την τομογραφία ανίχνευσης μονού φωτονίου (SPECT), η τομογραφία εκπομπής ποζιτρονίου (PET) και η απεικόνιση μαγνητικού συντονισμού (MRI). Σε προκλινικές εφαρμογές η λίστα εμπλουτίζεται με την χρήση υπερήχων και οπτικής τομογραφίας. Λόγω του ότι η λειτουργική απεικόνιση συνήθως δεν παρέχει επαρκεί ανατομική πληροφορία, είναι εξαιρετικά διαδεδομένα τα συνδυαστικά συστήματα. Η πιο διαδεδομένη υλοποίηση είναι το σύστημα PET/CT. Δηλαδή ο συνδυασμός ενός PET και ενός αξονικού τομογράφου. Με αυτό το τρόπο είναι δυνατή η λειτουργική απεικόνιση και ο ακριβής εντοπισμός της θέσης των διεργασιών αυτών. Το PET/CT παρουσιάστηκε αρχικά στις αρχές της δεκαετίας του '90 και το πρώτο σύστημα έγινε εμπορικά διαθέσιμο το 1998. Εκτός από την ανατομική πληροφορία το CT προσφέρει στο PET και ακριβείς συντελεστές εξασθένησης για την διόρθωση εξασθένησης, που βελτίωσε σημαντικά στην τελική ιατρική εικόνα του PET. Τα τελευταία χρόνια το ενδιαφέρον της επιστημονικής κοινότητας έχει στραφεί στον συνδυασμός του PET με τον μαγνητικό τομογράφο (PET/MR). Τα πλεονεκτήματα που μπορεί να προσφέρει αυτός ο συνδυασμός είναι ποικίλα. Το πιο σημαντικό, πιστεύουμε είναι, η παροχή ταυτόχρονης λειτουργικής και ανατομικής απεικόνισης. Δηλαδή, οι εικόνες PET πλέον θα έχουν πληροφορίες σχετικές και με την κίνηση είτε φυσική παραμόρφωση των ιστών (π.χ. κύκλος αναπνοής). Επίσης πληροφορίες απο το MRI μπορούν να βοηθήσουν στην διόρθωση μερικού όγκου (PVC) που παρουσιάζει το PET όταν απεικονίζει δομές μικρού όγκου. Με την χρήση ειδικών νανοσωματιδίων με μαγνητικό πυρήνα και της ταυτόχρονης απεικόνισης, δημιουργούνται νέες προοπτικές στοχευμένη θεραπείας και ταυτόχρονης απεικόνισής της. Οι δυνατότητες, αυτών των μεθόδων ακόμα είναι υπό μελέτη και ανάπτυξη, αλλά είναι εξαιρετικά υποσχόμενες. To PET/MRI απαιτεί όμως, την εφαρμογή τεσσάρων τεχνολογικών επιτευγμάτων που επηρεάζουν την τρέχουσα τεχνολογία αιχμής και όσον αφορά το ΡΕΤ αλλά και MRI, ως ανεξάρτητων συστημάτων. Πρώτον, η παλαιά τεχνολογία των φωτοπολλαπλασιαστών πρέπει να αντικατασταθεί με τους μαγνητικά μη ευαίσθητους ανιχνευτές SiPM. Δεύτερον, συμπαγείς ανιχνευτές PET πρέπει να είναι κατασκευασμένοι κατά τέτοιο τρόπο ώστε να είναι διαφανείς για το MRI ώστε να μην παρεμβαίνουν με το σταθερό πεδίο είτε με τις μαγνητικές ραδιοσυχνοτήτες. Τρίτον, ο σαρωτής MRI πρέπει να προσαρμοστεί για να φιλοξενήσει τους ανιχνευτές ΡΕΤ και να επιτρέψει την ταυτόχρονη και παράλληλη απόκτηση δεδομένων. Τέλος, η έρευνα σχετικά με τις βέλτιστες στρατηγικές για την τομογραφική ανακατασκευή εικόνας πρέπει να συνοδεύσουν ένα τέτοιο σύστημα. Η ανάπτυξη ολοκληρωμένων PET-MRI είναι, ως εκ τούτου, μια πολύπλευρη προσπάθεια που απαιτεί την σημαντική πρόοδο της τεχνολογίας του ΡΕΤ και του MRI και των δύο σε συνδυασμό. Ιστορικά, στα κλινικά PET συστήματα έχει επικρατήσει η κυλινδρική γεωμετρία, η οποία αποτελείται από διαδοχικούς δακτυλίους ανιχνευτών. Μεταξύ των οποίων μπορεί να υπάρχουν κινούμενα πετάσματα για την απομόνωση τους (2Δ είτε 3Δ λήψη δεδομένων). Πρώιμα συστήματα αποτελούνταν από ομαδοποιημένους (block) ανιχνευτές, οι οποίοι μπορεί και να περιστρέφονταν γύρω από το αντικείμενο προς απεικόνιση, ώστε να συλλέξουν προβολικά δεδομένα από διάφορες γωνίες, αλλά σύντομα, οι πλήρεις δακτύλιοι κατασκευάστηκαν. Πολλοί ερευνητές συνεχίσουν να κατασκευάζουν επίπεδα συστήματα PET, γιατί αίρουν αρκετούς περιορισμούς που έχουν τα κυλινδρικά συστήματα. Όπως, θέματα γεωμετρίας στα εφαπτομενικά πεδία καθώς η πηγή απομακρύνεται από το κέντρο του FOV. Η προβολή των κρυστάλλων, πάνω στην διάμετρο του συστήματος μικραίνει με αποτέλεσμα να παραμορφώνονται οι εικόνες στα άκρα του FOV, άμα κατάλληλοι αλγόριθμοι διόρθωσης δεν εφαρμοστούν. Επίσης, όσο πιο κοντά στην άκρη βρίσκεται η πηγή η γωνία μεταξύ της επιφάνειας των κρυστάλλων και τη των φωτονίων μεγαλώνει, οδηγώντας σε σφάλματα βάθους αλληλεπίδρασης (DOI). Τα προβλήματα αυτά εξομαλύνονται άμα η ακτίνα του κυλίνδρου είναι σημαντικά μεγαλύτερη από την ακτίνα του FOV. Αλλά με αυτό το τρόπο μειώνεται σημαντικά η ευαισθησία. Οι γεωμετρίες με ανεξάρτητες κεφαλές, στην απλή του μορφή, χρησιμοποιούν δύο ανιχνευτές χωρικά ευαίσθητους και μια μέθοδο ανακατασκευής εικόνας περιορισμένης γωνίας. Οι κεφαλές βρίσκονται εκατέρωθεν και μπορεί προαιρετικά να περιστρέφονται. Για ίδιο αριθμό ανιχνευτών, σε σχέση με τα κυλινδρικά συστήματα, έχουν τουλάχιστον διπλή ογκομετρική ευαισθησία το οποίο συνεπάγεται καλύτερες καμπύλες αντίθεσης και θορύβου. Αναπτύχθηκαν κυρίως στην δεκαετία του 70 ως μια προέκταση της κάμερας του Anger. Λίγα συστήματα είχαν αναπτυχθεί μέχρι την δεκαετία του 90 λόγω του υψηλού κόστους και των περιορισμένων εφαρμογών. Με την ανάπτυξη νέων ακτινοδιαγνωστικών προϊόντων, της ανάγκης λειτουργικής απεικόνισης μικρών ζώων και την πτώση του κόστους των υπολογιστών η απαίτηση για πολυμορφικά συστήματα PET μικρής κλίμακας επανέφερε δυναμική τις γεωμετρίες ανεξάρτητων κεφαλών, ιδιαίτερα δύο και τεσσάρων. Τα PET δύο είτε τεσσάρων ανεξάρτητων κεφαλών, όμως, λόγω της κοντινότερης απόστασης από την πηγή εκπομπής, μικρότερο μέγεθος και ευέλικτη γεωμετρία, μπορούν να χρησιμοποιηθούν στην βέλτιστη εξειδικευμένη απεικόνιση και στην απεικόνιση μικρών ζώων. Σε άλλες περιπτώσεις μπορούν να χρησιμοποιηθούν εκεί που η χρήση της κυλινδρικής γεωμετρίας, μπορεί να είναι και αδύνατη. Ως συστήματα, έχουν βρει εφαρμογές, στην προκλινική απεικόνιση μικρών ζώων και στην ανερχόμενη κλινική εφαρμογή της Μαστογραφίας Ανίχνευσης Ποζιτρονίου (PEM - Positron Emission Mammography). Στην παρούσα διδακτορική διατριβή χρησιμοποιήθηκε για την αξιολόγηση των αλγορίθμων ανακατασκευής καθώς και την επαλήθευση των μοντέλων προσομοίωσης, ένα επίπεδο σύστημα PET δύο κεφαλών. Η σχεδίαση του συστήματος είναι προσαρμοσμένη στην απεικόνιση μικρών ζώων. Το σύστημα αναπτύχθηκε από την Detector and Imaging Group του Εθνικού Κέντρου Επιτάχυνσης "Thomas Jefferson" (USA) σε συνεργασία με το τμήμα Ιατρικών Οργάνων του ΤΕΙ Αθηνών. Βρίσκεται εγκατεστημένο στο Ινστιτούτο Ραδιοϊσοτόπων και Ραδιοδιαγνωστικών προϊόντων του ερευνητικού κέντρου "Δημόκριτος". Αποτελείτε από δύο κεφαλές, θωρακισμένες με Βολφράμιο πάχους 4 mm. Κάθε κεφαλή αποτελείτε από ένα χωρικά ευαίσθητο φωτοπολλαπλασιαστή (PSPMT) H8500 της Hamamatsu, μια μήτρα 20x20 κρυστάλλων LSO:Ce διαστάσεων 2x2x10 mm^3. Η Πρόσθια επιφάνεια του H8500 είναι 50x50 mm^2. Ανάμεσα στους κρυστάλλους υπάρχει λευκό ανακλαστικό υλικό 0.2 mm. Η σύζευξη μεταξύ του φωτοπολλαπλασιαστή και της μήτρας κρυστάλλων έγινε με γυαλί πάχους 5 mm. Λόγω του ότι η επιφάνεια της μήτρας είναι μικρότερη από του φωτοπολλαπλασιαστή το γυαλί έχει σχήμα τραπέζιο. Για την αναβάθμιση του συστήματος σε τομογραφικό κατασκευάστηκαν δύο ικριώματα. Το πρώτο ήταν φτιαγμένο από ξύλο και το δεύτερο από plexiglass. Τα υλικά επιλέχτηκαν για την μαγνητική τους συμβατότητα, το χαμηλό κόστος και την ευκολία στην αναπαραγωγή τους. Για την κατασκευή του χρησιμοποιήθηκε το ίδιο σχέδιο. Το οποίο βασίζεται σε δύο κυκλικές επιφάνειας ανάμεσα στις οποίες σταθεροποιούνται οι κεφαλές. Οι επιφάνειες, αυτές, περιστρέφονται πάνω σε δύο ράουλα, τα οποία είναι στερεωμένα σε μια κοινή βάση. Ο έλεγχος της κίνησης γίνεται με ένα βηματικό κινητήρα. Τα ικριώματα σχεδιάστηκαν με κύριο γνώμονα την εύκολη μεταβολή της απόστασης μεταξύ των κεφαλών, ώστε να μπορεί να προσαρμοστεί στις ανάγκες του κάθε πειράματος. Η ελάχιστη απόσταση που μπορούν να έχουν οι κεφαλές είναι τα 7 cm και η μέγιστη τα 14 cm. Στο σχέδιο προβλέφθηκαν υποδοχές για ακόμα δύο κεφαλές ώστε να μπορεί να μετατραπεί σε τετρακέφαλο PET. Το σύστημα μπορεί να καταγράψει προβολικές εικόνες χωρίς περιστροφή, με την χρήση του αλγορίθμου Focal Plane Tomography(FPT). Ο αλγόριθμός FPT χρησιμοποιεί το Πυθαγόρειο θεώρημα για υπολογίσει την απόσταση μεταξύ των συντεταγμένων που υπολογίζονται από τον τύπου του κέντρου βάρους, κάθε κεφαλής. Στην συνέχεια, το φωτόνιο κατανέμεται στην μέση της απόστασης μεταξύ των κεφαλών. Οι τελικές εικόνες απαντώνται στην βιβλιογραφία και ως "εικόνες σύμπτωσης" (coincidence images). Λόγω του, ο αλγόριθμος, κάνει την υπόθεση ότι η πηγή βρίσκεται ολόκληρη στην μέση της απόστασης μεταξύ των κεφαλών, παρουσιάζει καλή απόδοση, μόνο όταν η πηγή είναι αρκετά λεπτή σε σχέση με την απόσταση των κεφαλών και βρίσκεται στο κέντρο του FOV. Καθώς, όμως, η πηγή πλησιάζει στην μια από τις δύο κεφαλές η ευαισθησία, η ομοιομορφία πεδίου και ιδιαίτερα η χωρική διακριτική ικανότητα γρήγορα υποβαθμίζονται. Η αξιολόγηση του συστήματος σε στατική απεικόνιση έδειξε ότι όταν οι κεφαλές έχουν απόσταση 5 cm, η απόκριση του συστήματος είναι γραμμική μέχρι τα 3.5 ΜBq, στην οποία παρουσιάζεται ο κορεσμός. Η ενεργότατο αυτή κρίνεται επαρκής για όλες τις απεικονίσεις μικρών ζώων. Όταν η απόσταση μεταξύ των κεφαλών είναι μεγαλύτερη το σύστημα είναι γραμμικό για πάνω από 4 MBq. Ένα περιορισμός της μεθόδου παρουσιάζεται στην ευαισθησία του συστήματος. Σε απόλυτους αριθμούς, οι εικόνες σύμπτωσης έχουν λιγότερα γεγονότα στης μικρές αποστάσεις κεφαλών, παρόλο που η ροή φωτονίων από τη πηγή είναι αρκετά μεγαλύτερη. Αυτό συμβαίνει, λόγω της μέγιστης γωνίας αποδοχής. Η μέγιστη γωνία αποδοχής είναι η γωνία την οποία άμα έχει μια LOR τότε αυτή απορρίπτεται. Η οριακή, αυτή, κατάσταση χρησιμοποιείτε για να αντιμετωπιστούν τα έντονα φαινόμενα παραλλαγής (parallax) που θα εμφανίζονταν αλλιώς. Το φαινόμενο παραλλαγής παρουσιάζεται, λόγω του ότι οι ανιχνευτές είναι επίπεδη και ώς εκ' τούτου όταν η γωνία της LOR είναι μεγάλη τότε το $\gamma$-φωτόνιο μπορεί να περάσει μέσα από 1 είτε περισσότερους κρυστάλλους, πριν τελικά απορροφηθεί. Οδηγώντας σε σφάλμα στον εντοπισμό της πραγματικής του θέσης. Ένας άλλος λόγος που χρησιμοποιείτε η μέγιστη γωνία αποδοχής είναι ότι η ευαισθησία στο κέντρο του FOV είναι πολύ μεγαλύτερη. Οπότε άμα δεχόμασταν όλες τις LOR θα δημιουργούσαμε αλλοιώσεις στην τελική εικόνα. Η χωρική διακριτική ικανότητα του συστήματος σε στατική απεικόνιση είναι τα 2.5 mm και 1.9 mm σε τομογραφική. Για απόσταση κεφαλών 8 cm οι στατικές, όπως και οι τομογραφικές εικόνες έχουν ομοιόμορφη ευαισθησία στη κεντρική 4x4 cm^2 περιοχή. Στις άκρες η ομοιομορφία της ευαισθησίας πέφτει στο 10%. Με την λήψη διαδοχικών προβολών FPT, από διάφορες γωνίες γύρω από το FOV, ώστε κάθε προβολή να αποτελείτε από δεδομένα που λήφθηκαν σε μια συγκεκριμένη γωνία καταμήκος όλων των τομών, μπορούμε να υπολογίσουμε 2Δ ημιτονογράμματα. Τα ημιτονογράμματα στην συνέχεια μπορούν να ανακατασκευαστούν σε τομογραφικές τομές, με χρήση αλγορίθμων ανάλογων των SPECT συστημάτων. Συνέπεια του ότι για την κατασκευή των ημιτονογραμμάτων χρησιμοποιούνται οι προβολές FPT, είναι ότι οι περιορισμοί αυτής της μεθόδου κληροδοτούνται και στην τομογραφική ανακατασκευή. Επιπλέον, δεν είναι δυνατόν να γίνει 3Δ ανακατασκευή, γιατί η πληροφορία των LOR έχει χαθεί κατά την δημιουργία των εικόνων σύμπτωσης. Παρόλους τους περιορισμούς, στον στατικό και τομογραφικό αλγόριθμο, το σύστημα είναι ικανό να απεικονίσει μικρά ζώα με ακρίβεια. Για να καλυφθεί ολόκληρο το σώμα, μαζί με την ουρά, ενός μικρού ποντικιού χρειάζονται τρεις θέσεις κρεβατιού, αλλά όλες οι κύριες λειτουργικές δομές καλύπτονταισ με δύο θέσεις. Οι στατικές εικόνες μπορούν να χρησιμοποιηθούν και εξαγωγή φαρμακοκινητικών μοντέλων, ενώ η τομογραφία με περιστροφή, για εξαγωγή εικόνων υψηλότερη ακρίβειας. Η γεωμετρία του πρωτότυπου συστήματος προσομοιώθηκε με την χρήση του πακέτου GATE (εκ. 6.0). Το GATE είναι μια εφαρμογή που βασίζεται σε τεχνικές Monte Carlo για την προσομοίωση φυσικών διαδικασιών. Επιπλέον, παρέχει μια σειρά από εργαλεία για την δημιουργία γεωμετριών που χρησιμοποιούνται σε συστήματα πυρηνική ιατρικής. Βιβλιογραφικά έχει βρει εφαρμογή στην μελέτη φυσικών διαδικασιών στην πυρηνική ιατρική, μελέτη/ανάπτυξη νέων συστημάτων, ανάπτυξη και αξιολόγηση αλγορίθμων ιατρικής ανακατασκευής εικόνας και μελέτες σχετικές με την οργανολογία στην πυρηνική ιατρική. Δύο μοντέλα δημιουργήθηκαν, επαληθεύτηκαν και μελετήθηκαν. Το πρώτο συμπεριλάμβανε την φυσική ραδιενέργεια του ^176Lu, που βρίσκεται μέσα στους κρυστάλλους LSO:Ce. Ενώ στο δεύτερο μοντέλο η ενεργότατο αυτή παραλήφθηκε. Η προεπιλογή του GATE είναι να μην την συμπεριλαμβάνει. Η συγκέντρωση της φυσικής ραδιενέργειας του $^{176}$Lu βρέθηκε στην βιβλιογραφία ως 277Bq/cm^3. Η ραδιενέργεια αυτή κατανεμήθηκε ομοιόμορφα μέσα στον συνολικό όγκο της μήτρας των κρυστάλλων, λαμβάνοντας υπόψιν τον όγκο των διαχωριστικών. Τα δύο μοντέλα επαληθεύθηκαν με την χρήση των πειραματικών δεδομένων, της αξιολόγησης του συστήματος, σε όρους ρυθμού γεγονότων σκότους, ρυθμού γεγονότων με πηγή (cps), κλάσματος σκεδαζόμενων (sf). Για να επαληθεύσουν τα πειραματικά δεδομένα, τα δύο μοντέλα έπρεπε να χρησιμοποιηθεί διαφορετικός νεκρός χρόνος (dead time). Παρότι η ενεργότητα του ^176Lu ήταν αρκετά μικρότερη από αυτή της πηγής. Στις ενεργότητες κάτω από 100 kBq η επιρροή από την φυσική ραδιενέργεια του ^176Lu, γίνεται σημαντική και τα αποτελέσματα των δύο μοντέλων αποκλίνουν σημαντικά. Ενεργότητες αυτού του επιπέδου δεν είναι σπάνιο να βρεθούν σε απεικονίσεις μικρών ζώων, ιδιαίτερα σε περιστροφικά συστήματα που η τομογραφική λήψη δεδομένων γίνεται σειριακά. Συνεπώς, η ελάχιστη ανιχνεύσιμη ενεργότητα μεταξύ των δύο μοντέλων διαφέρει σημαντικά. Αποκλίσεις παρατηρούνται και στην καμπύλη NECR. Στην οποία τα δυο μοντέλα ταυτίζονται στο γραμμικό κομμάτι της απόκρισης του συστήματος αλλά δεν αποκλίνουν και στο σημείο της κορυφής. Καθώς ανεβαίνει η ενεργότητα της πηγής και ο νεκρός χρόνος της κάμερας γίνεται πιο σημαντικός για την καταγραφή των δεδομένων. Έτσι, το μοντέλο που ο νεκρός χρόνος είναι μεγαλύτερος υποεκτιμάει τα ανιχνευθέντα γεγονότα. Αποκλίσεις παρατηρούνται και στην γραμμική περιοχή καθώς η έλλειψη της φυσικής ραδιενέργειας ενισχύει την εκτίμηση της χωρικής διακριτικής ικανότητας και τον λόγω σήματος προς θορύβου. Με αναλυτική διερεύνηση της προέλευσης των ανιχνευθέντων φωτονίων στα αποτελέσματα των προσομοιώσεων, συμπεράναμε ότι με την χρήση υψηλού κατωφλίου στους ανιχνευτές και διευρυμένου ενεργειακού παραθύρου βελτιώνει την ευαισθησία του συστήματος σε όρους NECR, αφού περισσότερα αληθή γεγονότα ανιχνεύονται ενώ τα τυχαία και σκεδασμένα φωτόνια απορρίπτονται από νωρίς, χωρίς να επιβαρύνουν περαιτέρω τον νεκρό χρόνο του συστήματος. Διερεύνηση με όρους SNR, με την επιπλέον προσθήκη κυλίνδρου με διάμετρο 4 cm, ως σκεδαστή έδειξαν ότι ο βέλτιστος λόγος σήματος προς θόρυβο επιτυγχάνεται όταν το κατώφλι του ενεργειακού παραθύρου είναι 350 keV. Κάτω από αυτό το όριο τα σκεδασμένα αυξάνονται σημαντικά και πιο πάνω μεγάλο μέρος από αληθή γεγονότα, απορρίπτονται. Χρησιμοποιώντας μια γραμμική πηγή, η ελάχιστη ανιχνεύσιμη ενεργότητα προσδιορίστηκε 12.4 MBq, χρησιμοποιόντας τις ρυθμίσεις που αναφέρθηκαν προηγουμένως. Χρησιμοποιώντας ένα πιο πολύπλοκο ομοίωμα η ελάχιστη ενεργότητα περιμένουμε να πάρει μεγαλύτερες τιμές. Προσομοιώσεις πραγματοποιήθηκαν ώστε να προσδιοριστεί και η επίδραση ενός σταθερού μαγνητικού πεδίου στις επιδόσεις του συστήματος. Το μαγνητικό πεδίο είχε τιμές 1.5, 3.0, 7.0 και 9.0 T που είναι συνήθεις τιμές που βρίσκονται σε εμπορικά συστήματα MRI. Το πεδίο εφαρμόστηκε κατά τον διαμήκη άξονα z. Τα αποτελέσματα δείχνουν ότι όταν δεν υπάρχει γύρω από την πηγή αρκετό υλικό (π.χ. νερό) ώστε να προκαλέσει εξαϋλώσεις των ποζιτρονίων, τότε η ελάχιστη ανιχνεύσιμη ενεργότητα βελτιώνεται σημαντικά. Αυτό συμβαίνει διότι το μαγνητικό πεδίο μειώνει την μέση απόσταση εξαΰλωσης. Με συνέπεια λιγότερα ποζιτρόνια να δραπετεύουν. Η παρατήρηση αυτή έχει σημαντικές βελτιώσεις στην απεικόνιση μικρών όγκων εντός των πνευμόνων, είτε σε όγκους που βρίσκονται στην επιδερμίδα. Τα αποτελέσματα επίσης έδειξαν ότι η διακριτική ικανότητα βελτιώνεται σημαντικά. Με σκοπό την απαλοιφή των περιορισμών της ανακατασκευής με χρήση διαδοχικών προβολών FPT γύρω από το FOV μελετήθηκε η χρήση του πακέτου STIR. Το STIR είναι μια εργαλειοθήκη λογισμικών με σκοπό την ιατρική ανακατασκευή εικόνων PET. Παρέχει πολλά φίλτρα και εργαλεία για την βελτίωση της εικόνας, αλλά στα πλαίσια της διατριβής χρησιμοποιήθηκε μόνο ο αλγόριθμος OSEM. Λόγω του ότι το STIR υποστηρίζει μόνο ανακατασκευή εικόνας σε κυλινδρικές γεωμετρίες, βρέθηκε τρόπος να ταξινομηθούν τα δεδομένα με συμβατό τρόπο. Για τον σκοπό αυτό χρησιμοποιήθηκαν οι πολικές συντεταγμένες του κάθε κρυστάλλου σε σχέση με την ακτίνα περιστροφής και την γωνία από την οποία λαμβάνουν δεδομένα οι κεφαλές. Με βάση αυτή την συνάρτηση τα δεδομένα κατανεμήθηκαν σε 3Δ ημιτονογράμματα. Λάβαμε υπ' όψιν μια τυπική διόρθωση εξασθένησης, υποθέτοντας ότι στο FOV υπάρχει μόνο αέρας. Η διόρθωση αυτή έγινε μαθηματικά οπισθοπροβάλοντας τον συντελεστή εξασθένησης του αέρα σε 3Δ ημιτονογράμματα. Για τ

Page generated in 0.0894 seconds