1

Simulação energética para análise da arquitetura de edifícios de escritório além da comprovação de conformidade com códigos de desempenho / Building performance simulation for analysis of the architecture of office buildings beyond code compliance checking

Cavalcante, Rodrigo de Castro Dantas 07 April 2010 (has links)
No Brasil e em São Paulo, a ASHRAE Standard 90.1 Energy Standard for Buildings Except Low-Rise Residential Buildings ganhou rápida aceitação nos últimos anos. A norma é referenciada pelo sistema de certificação Leadership in Energy and Environmental Design - LEED para estabelecer padrões mínimos de desempenho energético. Apesar do desenvolvimento de atividade de consultoria para comprovação de conformidade com esse código, a consultoria tem se limitado a intervir no projeto de arquitetura após sua concepção. A fim de investigar a influência da arquitetura no desempenho de edifícios de escritório e justificar a consultoria desde as primeiras etapas do projeto, o desempenho de uma série de modelos é estimado com auxílio da ferramenta de simulação computacional EnergyPlus. As alternativas avaliadas incluem diferentes percentagens de área de fachada envidraçada, propriedades ópticas e térmicas dos fechamentos transparentes, persianas automatizadas, orientação do edifício e proporções do pavimento tipo. Os resultados comprovaram a influência da arquitetura no desempenho energético de edifícios de escritório. Portanto, as decisões tomadas durante a fase de concepção do projeto têm impacto considerável no desempenho final do edifício e, apesar do tempo e dos esforços necessários, devem ser estudadas. / In Brazil and Sao Paulo, ASHRAE Standard 90.1 Energy Standard for Buildings Except Low-Rise Residential Buildings has rapidly gained acceptance in recent years. The standard is referred by the Leadership in Energy and Environmental Design - LEED rating system to set minimum energy performance levels. Although consulting activity was developed to demonstrate compliance to the code, it has been limited to intervene in the architectural design after its conception. With the aim of investigating the influence of architecture on the performance of office buildings and justify the consultancy since early design stages, the performance of a set of models is estimated using EnergyPlus computer simulation tool. The assessed alternatives include different Window-to-Wall Ratios - WWR, optical and thermal properties of glazing systems, automated roller shades, building orientation and proportions of typical floors. The results confirmed the influence of architecture on the energy performance of office buildings. Therefore, decisions taken during early design stages have considerable impact on the final performance of buildings and, despite the time and effort involved, should be studied.
2

Simulação energética para análise da arquitetura de edifícios de escritório além da comprovação de conformidade com códigos de desempenho / Building performance simulation for analysis of the architecture of office buildings beyond code compliance checking

Rodrigo de Castro Dantas Cavalcante 07 April 2010 (has links)
No Brasil e em São Paulo, a ASHRAE Standard 90.1 Energy Standard for Buildings Except Low-Rise Residential Buildings ganhou rápida aceitação nos últimos anos. A norma é referenciada pelo sistema de certificação Leadership in Energy and Environmental Design - LEED para estabelecer padrões mínimos de desempenho energético. Apesar do desenvolvimento de atividade de consultoria para comprovação de conformidade com esse código, a consultoria tem se limitado a intervir no projeto de arquitetura após sua concepção. A fim de investigar a influência da arquitetura no desempenho de edifícios de escritório e justificar a consultoria desde as primeiras etapas do projeto, o desempenho de uma série de modelos é estimado com auxílio da ferramenta de simulação computacional EnergyPlus. As alternativas avaliadas incluem diferentes percentagens de área de fachada envidraçada, propriedades ópticas e térmicas dos fechamentos transparentes, persianas automatizadas, orientação do edifício e proporções do pavimento tipo. Os resultados comprovaram a influência da arquitetura no desempenho energético de edifícios de escritório. Portanto, as decisões tomadas durante a fase de concepção do projeto têm impacto considerável no desempenho final do edifício e, apesar do tempo e dos esforços necessários, devem ser estudadas. / In Brazil and Sao Paulo, ASHRAE Standard 90.1 Energy Standard for Buildings Except Low-Rise Residential Buildings has rapidly gained acceptance in recent years. The standard is referred by the Leadership in Energy and Environmental Design - LEED rating system to set minimum energy performance levels. Although consulting activity was developed to demonstrate compliance to the code, it has been limited to intervene in the architectural design after its conception. With the aim of investigating the influence of architecture on the performance of office buildings and justify the consultancy since early design stages, the performance of a set of models is estimated using EnergyPlus computer simulation tool. The assessed alternatives include different Window-to-Wall Ratios - WWR, optical and thermal properties of glazing systems, automated roller shades, building orientation and proportions of typical floors. The results confirmed the influence of architecture on the energy performance of office buildings. Therefore, decisions taken during early design stages have considerable impact on the final performance of buildings and, despite the time and effort involved, should be studied.
3

Simulação termoenergética e proposta de melhoria em espaços de ensino e aprendizagem : estudo de caso campus Unisinos São Leopoldo

Fagundes, Suzana Fetter 05 January 2017 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2017-05-18T16:40:43Z No. of bitstreams: 1 Suzana Fetter Fagundes_.pdf: 5489681 bytes, checksum: 21bf7754ce6c0314a38ac237cc458c4d (MD5) / Made available in DSpace on 2017-05-18T16:40:43Z (GMT). No. of bitstreams: 1 Suzana Fetter Fagundes_.pdf: 5489681 bytes, checksum: 21bf7754ce6c0314a38ac237cc458c4d (MD5) Previous issue date: 2017-01-05 / Nenhuma / A habitabilidade do espaço construído afeta a capacidade produtiva das pessoas. Neste sentido, cabe verificar alternativas para otimizar o desempenho térmico das edificações, garantindo condições adequadas de conforto. Pesquisas realizadas no campus São Leopoldo da Universidade do Rio dos Sinos (UNISINOS), junto ao corpo discente, apontaram a necessidade de climatização das salas de aula. Este estudo se propõe a avaliar as condições atuais de temperatura dessas salas e investigar alternativas, através de simulações termoenergéticas, para aprimorar o desempenho térmico das edificações existentes. Com o uso do software Energy Plus foram analisados cenários alterando as características da envoltória da edificação com objetivo de aprimorar seu desempenho térmico e, com isso, reduzir a necessidade de sistemas artificiais de climatização. O estudo ponderou aspectos de viabilidade técnica e econômica de implantação e operação dos sistemas em um bloco de salas de aula tomado como piloto. Além disso, realizou uma comparação dos sistemas simulados com propostas técnicas obtidas no mercado. Os resultados mostram que, ao associar um sistema de climatização com a alteração da cor da cobertura para branco, é possível reduzir o consumo de energia em até 37,34%. O investimento necessário para a implantação dessa solução, pintura da cobertura e instalação de aparelhos de ar condicionado, gera um payback de 13,1 anos. / Built space habitability affects productive capacity of people. In this sense, it is necessary to search for alternatives to optimize the thermal performance of buildings, aiming to ensure adequate comfort conditions. Surveys carried out with the student body of Universidade do Vale do Rio dos Sinos (UNISINOS), at São Leopoldo campus, pointed out the need of classrooms thermal comfort enhancement. This study proposes to evaluate the current temperature conditions of those rooms and to investigate alternatives to improve thermal performance of existing buildings by means of thermoenergetic simulations. Using Energy Plus software, settings were analyzed considering possible changes on characteristics of the building envelope in order to improve its thermal performance and, therefore, reduce the need for artificial climatization systems. The study considered aspects of technical and economic feasibility of implantation and operation of the systems in a set of classrooms taken as pilot. In addition, the simulated systems were compared with technical proposals obtained in the market. The results show that combining air conditioning with changing the color of the roof the white, it is possible to reduce energy consumption by up to 37.34%. The payback for implementation of this solution, painting the roof white and installing the air conditioning equipment is 13.1 years.
4

Análise do COP anual de condicionadores de ar tipo Split fixo e inverter nas diferentes zonas bioclimáticas brasileiras

Rech, Letícia Dotta 12 April 2018 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2018-08-01T14:35:36Z No. of bitstreams: 1 Letícia Dotta Rech_.pdf: 7163933 bytes, checksum: b8456d05a1d302c866b6a463943d0889 (MD5) / Made available in DSpace on 2018-08-01T14:35:36Z (GMT). No. of bitstreams: 1 Letícia Dotta Rech_.pdf: 7163933 bytes, checksum: b8456d05a1d302c866b6a463943d0889 (MD5) Previous issue date: 2018-04-12 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho apresenta uma análise da relação entre o desempenho de equipamentos de condicionamento de ar tipo Split, fixo e inverter, para a climatização de uma edificação comercial nas diferentes zonas bioclimáticas brasileiras. As análises foram realizadas por simulação computacional, através do programa EnergyPlus. Foram simulados oito casos seguidos pelo modelo de referência. O modelo de referência adotado foi criado a partir de um levantamento fotográfico de edificações comerciais padrões com mais de quatro pavimentos. A partir deste levantamento, a tipologia que foi adotada representa um edifício de dez pavimentos com perímetro de dimensões de 27 por 7,50 metros e, pé-direito de 2,60 metros. Para analisar o comportamento energético do modelo de referência foram inseridos dados dos componentes construtivos, do padrão de ocupação, das cargas energéticas do sistema de iluminação e dos equipamentos, do condicionamento de ar, com as suas respectivas curvas de desempenho, conforme fornecedor, e de infiltração, conforme norma. Com esses dados inseridos no EnergyPlus, foi possível dimensionar a carga térmica dos equipamentos de ar condicionado e seu desempenho energético, analisados através do COP anual simulado desses equipamentos. Com a simulação foi possível destacar os fatores que influenciam no consumo de energia de um sistema de ar condicionado no que diz respeito às condições climáticas, principalemente o impacto da temperatura externo no desempenho do equipamento. Nos resultados encontrados foi possível identificar que existe uma influência bastante significativa, principalmente quando se comparam regiões de alta temperatura externa e com de baixa temperatura externa e, em um segundo momento, valores altos e baixos de umidade relativa interna do ar ambiente, sendo que, altas umidades favorecem o desempenho do equipamento avaliado. Resultados bastante significativos foram encontrados na substituição de aparelhos Split fixo por aparelhos Split inverter, nos quais se alcançou uma redução de até 44% de economia em regiões específicas do país, seu COP anual simulado apresentou um indicador mais eficiente em todas as horas simuladas. / This work presents an analysis of the relationship between the performance of split, fixed and inverter air conditioning equipment for the air conditioning of a commercial building in the different Brazilian bioclimatic zones. Analyzes were performed by computer simulation using the EnergyPlus program. Eight cases followed by the reference model were simulated. The reference model adopted was created from a photographic survey of standard commercial buildings with more than four floors. From this survey, the typology that was adopted represents a ten-storey building with a perimeter of dimensions of 27 by 7.50 meters and, at the foot of 2.60 meters. In order to analyze the energy performance of the reference model, data were included on the building components, occupancy pattern, energy loads of the lighting system and equipment, air conditioning, with their respective performance curves, as supplier, and infiltration, according to norm. With these data inserted in the EnergyPlus, it was possible to measure the thermal load of the air conditioning equipment and their energy performance, analyzed through the simulated annual COP of this equipment. With the simulation, it was possible to highlight the factors that influence the energy consumption of an air conditioning system with regard to climatic conditions, mainly the impact of external temperature on the performance of the equipment. In the results, it was possible to identify that there is a significant influence, especially when comparing high temperature and external low temperature regions, and in a second moment, high and low values of internal relative humidity of the ambient air, high performance favors the performance of the equipment evaluated. Significant results were found in the replacement of fixed split devices with split inverter devices, in which a reduction of up to 44% of savings was achieved in specific regions of the country, its annual simulated COP showed a more efficient indicator at all simulated hours.
5

Análise da eficiência energética do sistema de condicionamento de ar com distribuição pelo piso em ambiente de escritório, na cidade de São Paulo, utilizando o modelo computacional Energyplus. / Energy efficiency analysis of underfloor air distribution (ufad) system for office rooms, at São Paulo city, using the ENERGYPLUS software.

Inatomi, Thais Aya Hassan 06 May 2008 (has links)
Este trabalho tem por finalidade avaliar o desempenho energético do sistema de condicionamento de ar com distribuição pelo piso (Underfloor Air Distribution System UFAD) em ambientes de escritório, considerando diferentes possibilidades de arquitetura do sistema e seus modos de operação com ciclos economizadores. Por meio de simulação computacional, as avaliações foram realizadas para o clima da cidade de São Paulo ao longo de um ano metereológico típico, mantendo as condições de conforto térmico no ambiente. O programa de simulação selecionado como ferramenta foi o EnergyPlus 2.1.0.023, visto que modelos numéricos nele implementados representam adequadamente o sistema UFAD e os ciclos economizadores. Como referência para o desenvolvimento dos modelos de simulação foi utilizada uma câmara de testes representativa de um ambiente de escritórios. Esta câmara foi desenvolvida por Leite (2003) para avaliação do conforto térmico propiciado pelo sistema UFAD. As curvas de distribuição de temperatura resultantes das simulações foram similares às curvas resultantes das medições executadas por esta autora. As simulações foram realizadas para duas arquiteturas diferentes do circuito de ar (com e sem desvio do ar de retorno) combinados com três diferentes modos de operação relacionados à vazão do ar exterior. A análise dos dados climáticos da cidade de São Paulo demonstra que a tomada de ar exterior pode ser majorada com a utilização de ciclos economizadores, reduzindo o consumo de energia do sistema. Os resultados desta pesquisa indicam uma estreita relação entre arquitetura do sistema, controle dos ciclos economizadores, e dados climáticos, revelando que a combinação entre esses parâmetros pode reduzir em 34,5% o consumo de energia elétrica do sistema UFAD na cidade de São Paulo. / The purpose of this research is to evaluate the energy performance of the Underfloor Air Distribution (UFAD) system at office buildings, considering different air loops design and economizer cycles while keeping thermal comfort for the weather data of São Paulo city, Brazil. Simulations were held using the EnergyPlus software version 2.1.0.023, since its numerical models can well represent UFAD systems and economizer cycles. One chamber representing an office room was used as reference for the simulation models. This chamber was developed by Leite (2003) to evaluate the thermal comfort conditions provided by the UFAD system. The curves of temperature distribution obtained from simulation were similar to those experimentally obtained by Leite (2003). Simulations were performed for two different air loops (with and without return air bypass) combined with three different outside air controls. The São Paulo weather data analysis demonstrates that the outside air flow can be increased with the use of economizer cycles, reducing electric energy consumption of the UFAD system. The results of this research indicate that there is a tight relationship between the system air loop design, economizer cycle control and weather data, which reveals that the combination between these parameters can reduce about 34,5% the electric energy consumption of UFAD system at São Paulo city.
6

Avaliação técnica e financeira da geração fotovoltaica integrada à fachada de edifícios de escritórios corporativos na cidade de São Paulo / Technical and financial evaluation of Building-Integrated Photovoltaics (BIPV) in corporate buildings in the city of São Paulo

Santos, Arthur Henrique Cursino dos 17 November 2015 (has links)
As edificações comerciais, públicas e residenciais foram responsáveis em 2014 por 50% do consumo de eletricidade no país. Considerando os últimos dez anos, enquanto o consumo médio dos diferentes setores da economia cresceu 3,5% ao ano, o consumo do setor comercial cresceu 5,4%. Os edifícios de escritórios corporativos representam grandes consumidores de energia, chegando a valores superiores aos 200 kWh/m2.ano. A geração distribuída é uma solução que vem sendo estudada no país, primeiramente pela aprovação da Resolução Técnica 482:2012 da ANEEL, que regulamenta a geração de eletricidade na baixa tensão e depois pela aprovação da Portaria 381:2015 que dispõe sobre a geração de eletricidade na média tensão. Apesar do crescimento da geração por fontes fotovoltaicas no mundo, no Brasil essa geração ainda é mínima frente às fontes hídricas e térmicas. Nos edifícios de escritórios corporativos a instalação de painéis fotovoltaicos na cobertura é bastante limitada, devido à disputa de espaço com outros serviços, como as áreas técnicas e heliponto. Nesse contexto, as fachadas aparecem como oportunidade para geração de eletricidade, através da tecnologia fotovoltaica integrada na arquitetura (BIPV). Nesse estudo foi avaliada a viabilidade técnica e financeira da geração integrada à arquitetura dos edifícios de escritórios corporativos da cidade de São Paulo a partir do uso de vidros fotovoltaicos. Os resultados indicam que existe um potencial de redução de 15% no consumo de eletricidade anual, considerando tanto a geração de eletricidade, quanto a redução do consumo do sistema de ar condicionado, que tem sua carga térmica reduzida com o uso dos vidros fotovoltaicos. A tecnologia já é viável financeiramente no mercado brasileiro quando associada ao vidro refletivo, apresentando um tempo de retorno simples de 2,9 anos, uma TIR de 34,2% e um VPL de 1.779.257,53, para um edifício em torre com 28.010 m2 de área condicionada e 21 andares. / Commercial, public and residential buildings accounted in 2014 for 50% of electricity consumption in Brazil. Considering the last ten years, while the average consumption of the different sectors of the economy increased by 3.5% per year, the consumption of the commercial sector grew 5.4%. Corporate buildings are major energy consumers, reaching values in the range of 200 kWh/m2.year. Distributed generation is a solution that has been studied in the country, primarily with the approval of the Technical Resolution 482:2012, which regulates the generation of electricity at low voltage and then with the approval of the General Ordinance 381:2015 which regulates the generation of electricity at medium voltage. Despite the growth in generation from photovoltaic sources in the world, in Brazil this generation is still minimal when compared to other sources, like hydro and thermal plants. In commercial buildings, the space to install photovoltaic panels on the roof is quite limited. In this context the facades appear as an opportunity to generate electricity through photovoltaic technology integrated in the architecture (BIPV). In this study we evaluated the technical and financial feasibility of the integrated generation to the architecture of corporate buildings in the city of Sao Paulo. The results indicate a 15% reduction potential in annual electricity consumption, considering both the electricity generation and the reduction of the consumption by the air conditioning system, which has a reduced thermal load when photovoltaic glass is used. The BIPV technology is already feasible in the Brazilian market when coupled with reflective glass, showing a simple payback of 2.9 years, an IRR of 34.2% and a NPV of 1,779,257.53, for a building with 28,010 m2 and 21 floors.
7

Análise da eficiência energética do sistema de condicionamento de ar com distribuição pelo piso em ambiente de escritório, na cidade de São Paulo, utilizando o modelo computacional Energyplus. / Energy efficiency analysis of underfloor air distribution (ufad) system for office rooms, at São Paulo city, using the ENERGYPLUS software.

Thais Aya Hassan Inatomi 06 May 2008 (has links)
Este trabalho tem por finalidade avaliar o desempenho energético do sistema de condicionamento de ar com distribuição pelo piso (Underfloor Air Distribution System UFAD) em ambientes de escritório, considerando diferentes possibilidades de arquitetura do sistema e seus modos de operação com ciclos economizadores. Por meio de simulação computacional, as avaliações foram realizadas para o clima da cidade de São Paulo ao longo de um ano metereológico típico, mantendo as condições de conforto térmico no ambiente. O programa de simulação selecionado como ferramenta foi o EnergyPlus 2.1.0.023, visto que modelos numéricos nele implementados representam adequadamente o sistema UFAD e os ciclos economizadores. Como referência para o desenvolvimento dos modelos de simulação foi utilizada uma câmara de testes representativa de um ambiente de escritórios. Esta câmara foi desenvolvida por Leite (2003) para avaliação do conforto térmico propiciado pelo sistema UFAD. As curvas de distribuição de temperatura resultantes das simulações foram similares às curvas resultantes das medições executadas por esta autora. As simulações foram realizadas para duas arquiteturas diferentes do circuito de ar (com e sem desvio do ar de retorno) combinados com três diferentes modos de operação relacionados à vazão do ar exterior. A análise dos dados climáticos da cidade de São Paulo demonstra que a tomada de ar exterior pode ser majorada com a utilização de ciclos economizadores, reduzindo o consumo de energia do sistema. Os resultados desta pesquisa indicam uma estreita relação entre arquitetura do sistema, controle dos ciclos economizadores, e dados climáticos, revelando que a combinação entre esses parâmetros pode reduzir em 34,5% o consumo de energia elétrica do sistema UFAD na cidade de São Paulo. / The purpose of this research is to evaluate the energy performance of the Underfloor Air Distribution (UFAD) system at office buildings, considering different air loops design and economizer cycles while keeping thermal comfort for the weather data of São Paulo city, Brazil. Simulations were held using the EnergyPlus software version 2.1.0.023, since its numerical models can well represent UFAD systems and economizer cycles. One chamber representing an office room was used as reference for the simulation models. This chamber was developed by Leite (2003) to evaluate the thermal comfort conditions provided by the UFAD system. The curves of temperature distribution obtained from simulation were similar to those experimentally obtained by Leite (2003). Simulations were performed for two different air loops (with and without return air bypass) combined with three different outside air controls. The São Paulo weather data analysis demonstrates that the outside air flow can be increased with the use of economizer cycles, reducing electric energy consumption of the UFAD system. The results of this research indicate that there is a tight relationship between the system air loop design, economizer cycle control and weather data, which reveals that the combination between these parameters can reduce about 34,5% the electric energy consumption of UFAD system at São Paulo city.
8

Metodologia para análise termoeconômica de sistemas de resfriamento distrital. / Thermoeconomic methodology for district cooling systems analysis.

Santos, Arthur Garuti dos 18 March 2019 (has links)
Com o constante desenvolvimento das áreas urbanas e aumento do consumo energético destinado a conforto térmico, um estudo foi realizado para formulação de uma metodologia de análise termoeconômica de sistemas distritais de resfriamento. O objetivo principal é descrever uma metodologia referente à implantação de sistemas distritais no Brasil, por sua vez, o objetivo secundário é aplicar a metodologia no estado de São Paulo, analisando as premissas utilizadas na metodologia. Primeiramente, apresentou-se uma visão geral e revisão de literatura dos sistemas de aquecimento e resfriamento distrital, indicando suas vantagens e desvantagens, bem como as diversas aplicações e desafios para sua implantação. Aplicações no cenário mundial foram expostas e analisadas, demonstrando que sua utilização em diversos países se estende por décadas. As principais vantagens observadas nas aplicações existentes estão relacionadas a maior eficiência energética e exergética global, redução das emissões de gases poluentes e confiabilidade do sistema. Por fim, a metodologia aplicada está apresentada em cinco etapas, de forma ordenada, baseando-se nas etapas de um projeto de sistemas distritais. Seu resultado é baseado em rotinas, simulações de processos e procedimentos de otimização, bem como aplicação de indicadores energéticos. Ao final das etapas e seu desenvolvimento matemático obtém-se um estudo preliminar de viabilidade da implantação de um sistema distrital. O estudo de caso apresentado aplica a metodologia para a cidade de São Paulo buscando descrever com detalhamento as premissas e etapas descritas. / The constant development of urban areas and increased energy consumption for thermal comfort encourage studies that formulate a methodology for thermoeconomic analysis of district cooling systems. The main objective is to describe a thermoeconomic methodology related to the implementation of district systems in Brazil. The secondary objective is to apply the methodology in the state of São Paulo, analyzing the premises used in the methodology. At first, an overview and literature review of district heating and cooling systems was presented, indicating their advantages and disadvantages, just as the various applications and challenges for their implementation. Applications on the world stage have been introduced and analyzed, demonstrating that their use in several countries extends for decades. The main advantages observed in the existing applications are related to global energy and exergy efficiency, reduction in greenhouse gases and reliability of the systems. Finally, the applied methodology is presented in five steps in an orderly manner based on the steps of a district system project. Its result is based on routines, process simulations and optimization procedures, as well as application of energy indicators. At the end of the steps and their mathematical development a preliminary study of the feasibility of the implantation of a district system is obtained. The present case study applies the methodology for the city of São Paulo and describe in detail the premises and steps.
9

Avaliação técnica e financeira da geração fotovoltaica integrada à fachada de edifícios de escritórios corporativos na cidade de São Paulo / Technical and financial evaluation of Building-Integrated Photovoltaics (BIPV) in corporate buildings in the city of São Paulo

Arthur Henrique Cursino dos Santos 17 November 2015 (has links)
As edificações comerciais, públicas e residenciais foram responsáveis em 2014 por 50% do consumo de eletricidade no país. Considerando os últimos dez anos, enquanto o consumo médio dos diferentes setores da economia cresceu 3,5% ao ano, o consumo do setor comercial cresceu 5,4%. Os edifícios de escritórios corporativos representam grandes consumidores de energia, chegando a valores superiores aos 200 kWh/m2.ano. A geração distribuída é uma solução que vem sendo estudada no país, primeiramente pela aprovação da Resolução Técnica 482:2012 da ANEEL, que regulamenta a geração de eletricidade na baixa tensão e depois pela aprovação da Portaria 381:2015 que dispõe sobre a geração de eletricidade na média tensão. Apesar do crescimento da geração por fontes fotovoltaicas no mundo, no Brasil essa geração ainda é mínima frente às fontes hídricas e térmicas. Nos edifícios de escritórios corporativos a instalação de painéis fotovoltaicos na cobertura é bastante limitada, devido à disputa de espaço com outros serviços, como as áreas técnicas e heliponto. Nesse contexto, as fachadas aparecem como oportunidade para geração de eletricidade, através da tecnologia fotovoltaica integrada na arquitetura (BIPV). Nesse estudo foi avaliada a viabilidade técnica e financeira da geração integrada à arquitetura dos edifícios de escritórios corporativos da cidade de São Paulo a partir do uso de vidros fotovoltaicos. Os resultados indicam que existe um potencial de redução de 15% no consumo de eletricidade anual, considerando tanto a geração de eletricidade, quanto a redução do consumo do sistema de ar condicionado, que tem sua carga térmica reduzida com o uso dos vidros fotovoltaicos. A tecnologia já é viável financeiramente no mercado brasileiro quando associada ao vidro refletivo, apresentando um tempo de retorno simples de 2,9 anos, uma TIR de 34,2% e um VPL de 1.779.257,53, para um edifício em torre com 28.010 m2 de área condicionada e 21 andares. / Commercial, public and residential buildings accounted in 2014 for 50% of electricity consumption in Brazil. Considering the last ten years, while the average consumption of the different sectors of the economy increased by 3.5% per year, the consumption of the commercial sector grew 5.4%. Corporate buildings are major energy consumers, reaching values in the range of 200 kWh/m2.year. Distributed generation is a solution that has been studied in the country, primarily with the approval of the Technical Resolution 482:2012, which regulates the generation of electricity at low voltage and then with the approval of the General Ordinance 381:2015 which regulates the generation of electricity at medium voltage. Despite the growth in generation from photovoltaic sources in the world, in Brazil this generation is still minimal when compared to other sources, like hydro and thermal plants. In commercial buildings, the space to install photovoltaic panels on the roof is quite limited. In this context the facades appear as an opportunity to generate electricity through photovoltaic technology integrated in the architecture (BIPV). In this study we evaluated the technical and financial feasibility of the integrated generation to the architecture of corporate buildings in the city of Sao Paulo. The results indicate a 15% reduction potential in annual electricity consumption, considering both the electricity generation and the reduction of the consumption by the air conditioning system, which has a reduced thermal load when photovoltaic glass is used. The BIPV technology is already feasible in the Brazilian market when coupled with reflective glass, showing a simple payback of 2.9 years, an IRR of 34.2% and a NPV of 1,779,257.53, for a building with 28,010 m2 and 21 floors.