Spelling suggestions: "subject:"pinus floor augmentation"" "subject:"minus floor augmentation""
1 |
PLA/PGA copolymer as a bone substitute in maxillary sinus augmentation: histological, histometric and immunohistochemistry study in rabbitsFerreira, Sabrina [UNESP] 03 February 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:29Z (GMT). No. of bitstreams: 0
Previous issue date: 2014-02-03Bitstream added on 2015-03-03T12:06:37Z : No. of bitstreams: 1
000800427.pdf: 8452943 bytes, checksum: c40ffd64f5262a9010864dacab63d5d7 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A proposta deste estudo foi avaliar a capacidade osteocondutora da forma sólida do copolímero de PLA/PGA em um modelo experimental de enxerto em seio maxilar . Vinte coelhos machos, branco, da raça Nova Zelândia, cada um pesando cerca de 3,0 kg, foram utilizados e foram divididos em dois grupos de acordo com o material de preenchimento do seio, como segue: ósseo autógeno particulado e copolímero PLA/PGA . A área aumentada diferiu entre os grupos após 3, 7 e 15 dias (p = 0,004) . No entanto, os valores tornaram-se semelhante aos 40 dias (p = 0,458). Depois de 3 e 7 dias, a porcentagem óssea foi estatisticamente significativa entre osso autógeno e PLA / PGA copolímero (P = 0,004 e P = 0,004). Após 15 e 40 dias os valores foram semelhantes nos dois períodos (P = 0,087 e P = 0,087 ). Imunohistoquímica confirma os resultados sobre os dados histomorfométricos. Em conclusão, o copolímero de PLA/PGA parece ser adequado como material reabsorvível capaz de induzir o crescimento do osso em defeitos ósseos. Esta observação sugere que o material tem propriedades osteocondutoras também apropriado para aplicação em cirurgia maxilo-facial / The proposition of this study was evaluate the osteoconductive capability of the solid form of PLA/PGA copolymer in an experimental model of maxillary sinus grafting. Twenty male white New Zealand rabbits, each weighing about 3.0kg, were used and were divided into two groups, according to the sinus filling material, as follows: autogenous bone chips and PLA/PGA copolymers. Augmented area differ between the groups after 3, 7 and 15 days (P=0.004). However, the values became similar on day 40 (P=0.458). After 3 and 7 days the percentage of bone was statistically significant between autogenous bone and PLA/PGA copolymer (P=0.004 and P=0.004). After 15 and 40 days the values were comparable in the two periods (P=0.087 and P=0.087). Immunohistochemistry confirms the results on the histomorphometric data. In conclusion, PLA/PGA copolymer seems to be suitable as resorbable material able to induce bone growth in bone defects. This observation suggests that the material have osteoconductive properties also suitable for application in maxillofacial surgery
|
2 |
PLA/PGA copolymer as a bone substitute in maxillary sinus augmentation : histological, histometric and immunohistochemistry study in rabbits /Ferreira, Sabrina. January 2014 (has links)
Orientador: Idelmo Rangel Garcia Júnior / Banca: Wilson Roberto Poi / Banca: Ronaldo Célio Mariano / A dissertação foi escrita em inglês / Resumo: A proposta deste estudo foi avaliar a capacidade osteocondutora da forma sólida do copolímero de PLA/PGA em um modelo experimental de enxerto em seio maxilar . Vinte coelhos machos, branco, da raça Nova Zelândia, cada um pesando cerca de 3,0 kg, foram utilizados e foram divididos em dois grupos de acordo com o material de preenchimento do seio, como segue: ósseo autógeno particulado e copolímero PLA/PGA . A área aumentada diferiu entre os grupos após 3, 7 e 15 dias (p = 0,004) . No entanto, os valores tornaram-se semelhante aos 40 dias (p = 0,458). Depois de 3 e 7 dias, a porcentagem óssea foi estatisticamente significativa entre osso autógeno e PLA / PGA copolímero (P = 0,004 e P = 0,004). Após 15 e 40 dias os valores foram semelhantes nos dois períodos (P = 0,087 e P = 0,087 ). Imunohistoquímica confirma os resultados sobre os dados histomorfométricos. Em conclusão, o copolímero de PLA/PGA parece ser adequado como material reabsorvível capaz de induzir o crescimento do osso em defeitos ósseos. Esta observação sugere que o material tem propriedades osteocondutoras também apropriado para aplicação em cirurgia maxilo-facial / Abstract: The proposition of this study was evaluate the osteoconductive capability of the solid form of PLA/PGA copolymer in an experimental model of maxillary sinus grafting. Twenty male white New Zealand rabbits, each weighing about 3.0kg, were used and were divided into two groups, according to the sinus filling material, as follows: autogenous bone chips and PLA/PGA copolymers. Augmented area differ between the groups after 3, 7 and 15 days (P=0.004). However, the values became similar on day 40 (P=0.458). After 3 and 7 days the percentage of bone was statistically significant between autogenous bone and PLA/PGA copolymer (P=0.004 and P=0.004). After 15 and 40 days the values were comparable in the two periods (P=0.087 and P=0.087). Immunohistochemistry confirms the results on the histomorphometric data. In conclusion, PLA/PGA copolymer seems to be suitable as resorbable material able to induce bone growth in bone defects. This observation suggests that the material have osteoconductive properties also suitable for application in maxillofacial surgery / Mestre
|
3 |
Utilização do plasma rico em plaquetas nos procedimentos cirúrgicos de elevação do seio maxilar: estudo histomorfométrico em humanosMartins, Marilia Compagnoni [UNESP] 09 September 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:29Z (GMT). No. of bitstreams: 0
Previous issue date: 2003-09-09Bitstream added on 2014-06-13T20:05:26Z : No. of bitstreams: 1
martins_mc_dr_arafo.pdf: 2338184 bytes, checksum: d19d1faa6e5b721d78be39854a2bfb47 (MD5) / O propósito do presente estudo foi o de avaliar histomorfometricamente a neoformação óssea da região posterior de maxila após os procedimentos cirúrgicos de elevação de seio maxilar e enxerto ósseo autógeno inlay associado ou não ao Plasma Rico em Plaquetas, em dois períodos de tempo: 6 e 8 meses. Foram selecionados 20 pacientes, com idade média de 42 anos, em boas condições de saúde geral. Os pacientes foram divididos, aleatoriamente em três grupos sendo: Grupo 1: enxerto ósseo autógeno e biópsia da área 8 meses após a cirurgia, 4 pacientes (grupo controle). Grupo 2: enxerto ósseo autógeno associado ao plasma rico em plaquetas e biópsia da área 6 meses após a cirurgia, 8 pacientes. Grupo 3: enxerto ósseo autógeno associado ao plasma rico em plaquetas e biópsia da área 8 meses após a cirurgia, 8 pacientes. Encontrou-se diferenças significantes nos períodos (G2 vs G3) em relação ao tecido ósseo (p=0,05) e em relação aos tecidos não calcificados (p=0,045), e nos tratamento (G1 vs G3) em relação a presença de material de enxerto (p=0,041). Baseado nos resultados obtidos, pôde-se concluir que em relação à quantidade e qualidade do tecido ósseo formado o uso do Plasma Rico em Plaquetas não apresentou benefícios adicionais à utilização do osso autógeno nos procedimentos cirúrgicos de elevação de seio maxilar. / The aim of the present study was to evaluated, histologic and histomorphometrically, bone formation after maxillary sinus floor augmentation by grafting with an association of PRP and autogenous bone from the symphyseal area. Out of 20 patients were used in this study, and they were distributed in three groups, G1: control - autogenous bone graft, 8 months healing period, G2 - autogenous bone graft and PRP, 6 months healing period, and G3: autogenous bone graft and PRP, 8 months healing period. Before surgery the blood was collected and proper stored, until PRP preparation. Subantral augmentation was performed and the graft was collected. The blood was centrifuged, the concentrate platelet-rich plasma layer was removed and associated to the autogenous graft. The mixture assumed a gel-like consistency, which was used to fill the sinus. After the period healing, implants were placed and core biopsies were taken from the area. Routine histological processing and staining were performed. There were no significant differences between the treatments (G1 vs G3). In regard to the healing period (G2 vs G3) we found significant differences due to bone (p=0,05) and non-calcified tissues (p=0,045), in regard to the type of treatment (G1 vs G3) we found significant differences due to the presence of grafted material (p=0,041). Within the limits of this study the association of PRP and autogenous bone did not bring any additional benefits in regard to bone formation.
|
4 |
Regeneração óssea guiada com o uso de membrana de copolímero PLA/PGA em levantamento da membrana do seio maxilar : estudo experimental com análises histomorfométrica e imunoistoquímica /Bomfim, Bianca Bravim. January 2015 (has links)
Orientador: Idelmo Rangel Garcia Júnior / Banca: Wilson Roberto Poi / Banca: Roberta Okamoto / Banca: Martha Alayde Alcantara Salim / Banca: Sergio Luiz Melo Gonçalves / Resumo: A utilização de biomateriais em implantodontia, principalmente em casos em que o leito receptor do implante apresenta quantidade e qualidade ósseas inadequadas, se torna importante. Diversos estudos mostram a possibilidade do usar copolímeros de PLA/PGA, no entanto, estes mesmos estudos mostram que a proporção de PLA e PGA irá influenciar a taxa de degradação do copolímero. Portanto, objetivo desse estudo foi avaliar o comportamento biológico do copolímero de PLA/PGA como substitutos ósseos para técnica de levantamento da membrana do seio maxilar por meio de análises histomorfométrica e imunoistoquímica. Vinte coelhos machos, branco, da raça Nova Zelândia, cada um pesando cerca de 3,0 kg, foram utilizados e foram divididos em dois grupos de acordo com o material de preenchimento do seio: grupo coágulo (GC) e grupo copolímero (GP). Foi realizado descolamento bilateral da membrana sinusal com períodos de eutanásia aso 3, 10, 20 e 40 dias para as análises histomorfométricas e imunoistoquímica para a expressão de osteocalcina (OC). De uma forma geral, para todas as variáveis avaliadas, a diferença estatisticamente significante mostrou-se entre 3 e 10 dias pós-operatórios (p<0,05), como pode ser demostrado também na expressão de OC. Foi possível concluir que o copolímero PLA/PGA mostrou-se capaz de conduzir o processo de formação óssea, mantendo o volume inicial, impedindo o colabamento da membrana com a parede do seio, como pode ser observado em GC / Abstract: The use of biomaterials in dental implantology, especially in cases where the receptor region of implant has inadequate bone quantity and quality, becomes important. Several studies have shown the possibility to use copolymers of PLA / PGA, however these same studies show that the proportion of PLA and PGA copolymer will influence the degradation rate. So the aim of this study was to evaluate the biological behavior of PLA / PGA copolymer as bone substitutes for lifting technique of the maxillary sinus membrane through histomorphometric and immunohistochemical analyzes. Twenty male rabbits, white, New Zealand race, each weighing about 3.0 kg, were used and were divided into two groups in accordance with within the filling material: Clot group (CG) and a copolymer group (PG) . Were realized the bilateral sinus lift of rabbits and inserted the respective materials with euthanasia periods as 3, 10, 20 and 40 days for histomorphometric and immunohistochemical analysis for the expression of osteocalcin (OC). In general, for all variables, a statistically significant difference was shown between 3 and 10 days postoperatively (p <0.05), as can be demonstrated also in OC expression. It was concluded that the PLA / PGA copolymer was shown to be able to conduct the process of bone formation, maintaining the initial volume, preventing the collapse of the membrane with the sinus wall, as can be observed in GC / Doutor
|
5 |
Utilização do plasma rico em plaquetas nos procedimentos cirúrgicos de elevação do seio maxilar : estudo histomorfométrico em humanos /Martins, Marilia Compagnoni. January 2003 (has links)
Resumo: O propósito do presente estudo foi o de avaliar histomorfometricamente a neoformação óssea da região posterior de maxila após os procedimentos cirúrgicos de elevação de seio maxilar e enxerto ósseo autógeno inlay associado ou não ao Plasma Rico em Plaquetas, em dois períodos de tempo: 6 e 8 meses. Foram selecionados 20 pacientes, com idade média de 42 anos, em boas condições de saúde geral. Os pacientes foram divididos, aleatoriamente em três grupos sendo: Grupo 1: enxerto ósseo autógeno e biópsia da área 8 meses após a cirurgia, 4 pacientes (grupo controle). Grupo 2: enxerto ósseo autógeno associado ao plasma rico em plaquetas e biópsia da área 6 meses após a cirurgia, 8 pacientes. Grupo 3: enxerto ósseo autógeno associado ao plasma rico em plaquetas e biópsia da área 8 meses após a cirurgia, 8 pacientes. Encontrou-se diferenças significantes nos períodos (G2 vs G3) em relação ao tecido ósseo (p=0,05) e em relação aos tecidos não calcificados (p=0,045), e nos tratamento (G1 vs G3) em relação a presença de material de enxerto (p=0,041). Baseado nos resultados obtidos, pôde-se concluir que em relação à quantidade e qualidade do tecido ósseo formado o uso do Plasma Rico em Plaquetas não apresentou benefícios adicionais à utilização do osso autógeno nos procedimentos cirúrgicos de elevação de seio maxilar. / Abstract: The aim of the present study was to evaluated, histologic and histomorphometrically, bone formation after maxillary sinus floor augmentation by grafting with an association of PRP and autogenous bone from the symphyseal area. Out of 20 patients were used in this study, and they were distributed in three groups, G1: control - autogenous bone graft, 8 months healing period, G2 - autogenous bone graft and PRP, 6 months healing period, and G3: autogenous bone graft and PRP, 8 months healing period. Before surgery the blood was collected and proper stored, until PRP preparation. Subantral augmentation was performed and the graft was collected. The blood was centrifuged, the concentrate platelet-rich plasma layer was removed and associated to the autogenous graft. The mixture assumed a gel-like consistency, which was used to fill the sinus. After the period healing, implants were placed and core biopsies were taken from the area. Routine histological processing and staining were performed. There were no significant differences between the treatments (G1 vs G3). In regard to the healing period (G2 vs G3) we found significant differences due to bone (p=0,05) and non-calcified tissues (p=0,045), in regard to the type of treatment (G1 vs G3) we found significant differences due to the presence of grafted material (p=0,041). Within the limits of this study the association of PRP and autogenous bone did not bring any additional benefits in regard to bone formation. / Orientador: Ricardo Samih Georges Abi Rached / Coorientador: Elcio Marcantonio Junior / Banca: Luís Carlos Spolidorio / Banca: Joni Augusto Cirelli / Banca: Luís Antônio Violin Dias Pereira / Banca: Elton Gonçalves Zenóbio / Doutor
|
6 |
Maxillary sinus floor augmentation with different bone grafting materials for dental implant treatment: A systematic reviewBanihashem, Tina, Zulfijaj, Florida January 2013 (has links)
Sammanfattning Syfte: Syftet med denna systematiska litteraturöversikt var att testa hypotesen att det inte är någon skillnad rörande lyckandefrekvensen gällande implantatbehandling vid sinuslyft med olika bentransplantatmaterial Material och metod: Studien baseras på sökningar i PubMed, Cochrane Library och Web of Science i kombination med en manuell granskning av relevanta publikationer. Inkluderade publikationer var prospektiva studier av ≥ 10 patienter och med en uppföljningstid på ≥ 1 år. Autologt bentransplantat från mandibel/maxilla, oorganiskt ben (Bio-Oss), en kombination av dessa två samt sinuslyft utan insättning av bentransplant utvärderades. Kvaliteten på varje publikation bedömas enligt kriterier baserade på en modifiering av STROBE-statment. Resultat: Sökningen resulterade i 818 titlar och 15 inkluderade publikationer relevanta enligt förutbestämda inklusionskriterier. En studie var en randomiserad kontrollerad studie (RCT) och en var en kontrollerad klinisk studie (CCT). De återstående 13 studierna var observationsstudier. Uppföljningen varierade mellan ett och nio år, och antalet patienter mellan 10 och 191. Sinuslyft utan insättning av bentransplantat hade en implantatöverlevnad på 97,7% -100% och studier rörande autologt bentransplantat 98,8%. Bio-Oss resulterade i 86,3% -98,1% överlevnad och en kombination av Bio-Oss och autologt ben resulterade i en överlevnad på 90,7%. Slutsats: Enligt denna undersökning fanns ingen skillnad i implantat överlevnad mellan de olika bentransplantaten. Beroende på studiernas karaktär behövs fler RCT och CCT studier, som analyserar implantatutfallet, involverar sinuslyft och olika bentransplantat rörande implantatöverlevnad och lyckandefrekvens. / AbstractAims: The objective was to test the hypothesis that there is no difference in implant treatment outcome using different bone graft material for sinus floor augmentation.Material and methods: This systematic review is based on searches in PubMed, the Cochrane Library and the Web of Science and a hand search of relevant publications. Autologous bone, anorganic bovine bone (Bio-Oss), a combination of these two and elevation of the Schneiderian membrane with no graft material was evaluated. The quality of each publication was assessed according to criteria based on the STROBE-statements.Results: The search provided 818 titles and 15 were found relevant according to the predetermined inclusion criteria. One study was a randomized controlled trial (RCT) and one was a controlled clinical trial (CCT). The remaining 13 studies were observation studies. The follow-up time varied between one and nine years and the number of patients between 10 and 191. Studies on elevation of the Schneiderian membrane with no bone graft material reported an implant survival rate between 97.7% and100% and studies on only autologous bone graft material 98.8%. Bio-Oss as bone graft material resulted in 86.3%-98.1% survival rate and a combination of Bio-Oss and autologous bone graft resulted in a survival rate of 90.7%.Conclusion: There was no difference in implant outcome of the different bone graft material. More studies designed as RCT and CCT, which analyze the implant outcome involving sinus floor augmentation and different bone graft material are needed to improve evidence on survival and success rate.
|
7 |
Avaliação microtomográfica e histomorfométrica comparativa de levantamento de seio maxilar em coelhos utilizando diferentes cerâmicas a base de fosfato de cálcio / Comparative microtomographic and histomorphometric evaluation of maxillary sinus augmentation using different calcium phosphate-based ceramicsSantos, Paula Sanches dos 25 May 2016 (has links)
A técnica de levantamento de seio maxilar (LSM) visa aumentar a altura óssea junto à superfície sinusal de maxila posterior atrófica utilizando diferentes materiais de preenchimento, para possibilitar a instalação de implantes dentários. Esses materiais de preenchimento podem variar quanto à origem e às propriedades físicoquímicas, resultando em diferentes respostas biológicas. O objetivo do atual trabalho foi avaliar a eficiência do Gen-Ox®inorg e GenPhos XP® na técnica de elevação do seio maxilar em comparação ao Bio-Oss®. Em 24 coelhos foi realizado o levantamento bilateral dos seios maxilares (SMs) utilizando 200 mm3 de material de preenchimento por seio, conforme os grupos experimentais Bio-Oss (6SMs/período), Gen-Ox (5SMs/período) e GenPhos (5SMs/período), e a janela óssea de acesso foi recoberta com uma membrana reabsorvível. Os animais de cada grupo foram eutanasiados aos 15, 30 e 60 dias e a região dos SMs foi coletada e fixada em formalina a 10% tamponada. As peças foram submetidas à análise microtomográfica para determinação do volume total do SM elevado e em seguida ao processamento histológico, sendo cortes coronais dos SMs obtidos e avaliados morfometricamente pelo método de volumetria de pontos. Todos os três materiais apresentaram excelente biocompatibilidade e promoveram a manutenção do volume do seio preenchido ao longo do tempo, sendo em média de 214,1 mm3. Em todos os grupos a formação óssea ocorreu em íntimo contato com as partículas de material. Ao término de 60 dias, o tecido ósseo formado mostrava-se maduro e preenchia parcialmente os espaços entre as partículas. A forma e tamanho das partículas de Gen-Ox gerou maior espaço entre as partículas que pode ter levado a formação de maior volume de tecido ósseo e de tecido conjuntivo (53,0 ± 10,1 mm3 e 74,1 ± 21,5 mm3) comparado ao Bio-Oss (43,7 ± 11,6 mm3 e 61,2 ± 23,3 mm3) e GenPhos (47,5 ± 10,4 mm3 e 58,5 ± 25,7 mm3). Baseado na estabilidade do volume sinusal elevado, na capacidade osteocondutora e na formação e maturidade óssea ao longo do tempo promovidos pelo Gen-Ox®inorg e GenPhos®, comparável ao do Bio-Oss®, conclui-se que esses dois biomateriais significam uma alternativa segura na técnica de LSM. / Maxillary sinus augmentation (MSA) for implant placement using bone graft or bone substitutes is a common procedure to increase the bone volume in the atrophic posterior part of the maxilla. Various bone substitutes have been used in sinus floor elevation procedures. Nonetheless, the biological performance of bone substitutes may vary according to origin, physical and chemical properties. The goal of this study was to evaluate the efficiency of both Gen-Ox®inorg and GenPhos XP® in maxillary sinus augmentation technique compared to Bio-Oss®. In 24 rabbits, it was conducted a bilateral lifting of the maxillary sinuses (MSs) using 200 mm3 of filling material for sinus in accordance with the experimental groups Bio-Oss (6SMs/period), Gen-Ox (5MSs/period) and GenPhos (5MSs/period). The sinus access window was covered with a resorbable membrane. The animals of each group were euthanized at 15, 30 and 60 days and the MSs were collected and fixed in 10% buffered formalin. The samples were submitted to microtomographic analysis to calculate the MS augmentation volume. Histological coronal sections of MS augmentation were used for morphological analysis and determination of volume density of each structure by point counting volumetry method. All three materials had excellent biocompatibility and promoted maintenance of the MS augmentation volume over time, averaging 214.1 mm3. In all groups the bone formation occurred in close contact with the material particles. At the end of 60 days, the bone tissue formed was mature and it partially filled the spaces between the particles. The shape and size of Gen-Ox particles generated greater space between the particles that may have led to a higher formation of bone volume and connective tissue (53.0 ± 10.1 mm3 and 74.1 ± 21.5 mm3) than Bio-Oss (43.7 ± 11.6 mm3 and 61.2 ± 23.3 mm3) and GenPhos (47.5 ± 10.4 mm3 and 58.5 ± 25.7 mm3). Based on the stability of the MS volume, the osteoconductive capacity and the bone formation and maturation over time promoted by Gen-Ox®inorg and GenPhos®, and comparable to Bio-Oss®, it is concluded that these two biomaterials may be a safe alternative in MSA technique.
|
8 |
Spätresultate nach minimalinvasiver Sinusbodenaugmentation / Long-term results after minimally invasive sinus floor augmentationBlendermann, Katja 15 November 2011 (has links)
No description available.
|
9 |
Reconstrução alveolar por aumento do assoalho do seio maxilar com beta-tricálcio fosfato ou osso autógeno para reabilitação com prótese implantossuportada / Alveolar reconstruction by enlargement of the maxillary sinus floor with beta-tricalcium phosphate or autogenous bone for rehabilitation with implant-supported prosthesisFerreira, Sabrina [UNESP] 06 October 2017 (has links)
Submitted by SABRINA FERREIRA null (sabrife@bol.com.br) on 2017-10-26T16:31:30Z
No. of bitstreams: 1
TESE FINAL.docx: 68772200 bytes, checksum: f6722c6fe1365b9fe81b2aa5d5b01539 (MD5) / Rejected by Monique Sasaki (sayumi_sasaki@hotmail.com), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo:
A versão final da dissertação/tese deve ser submetida no formato PDF (Portable Document Format).
O arquivo PDF não deve estar protegido e a dissertação/tese deve estar em um único arquivo, inclusive os apêndices e anexos, se houver.
Por favor, corrija o formato do arquivo e realize uma nova submissão.
Agradecemos a compreensão. on 2017-10-31T17:57:48Z (GMT) / Submitted by SABRINA FERREIRA null (sabrife@bol.com.br) on 2017-11-02T18:44:52Z
No. of bitstreams: 1
TESE FINAL.pdf: 1299336 bytes, checksum: 6585035d2ca784a2d052292a49407084 (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-11-10T18:05:35Z (GMT) No. of bitstreams: 1
ferreira_s_dr_araca.pdf: 1299336 bytes, checksum: 6585035d2ca784a2d052292a49407084 (MD5) / Made available in DSpace on 2017-11-10T18:05:35Z (GMT). No. of bitstreams: 1
ferreira_s_dr_araca.pdf: 1299336 bytes, checksum: 6585035d2ca784a2d052292a49407084 (MD5)
Previous issue date: 2017-10-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A altura insuficiente do osso alveolar é um fator limitante para a reabilitação oral com próteses implantossuportadas. Taxas de sucesso clínico com uso de biomateriais à base de beta-tricálcio fosfato (b-TCP) para elevação do assoalho do seio maxilar (EASM) mostraram que são excelentes alternativas ao osso autógeno (OA). Portanto, objetivo foi avaliar a formação óssea do enxerto de b-TCP em bloco, seis meses após EASM, comparada ao OA por meio de análises tomográfica, microtomográfica e histomorfométrica. Para isso, Oito seios maxilares foram enxertados com b-TCF e sete OA. Após 6 meses, foram obtidas biópsias durante à instalação de implantes dentários. Não houve diferença significante (ANOVA) entre a contração do volume dos seios maxilares preenchidos por OA e b-TCP (p=0,113), bem como para todos os parâmetros microtomográfico (ANOVA) BV/TV (p=0.089), Tb.Th (p=1.000), Tb.Sp (p=0,989) e Tb.N (p=0.917). Na histomorfometria quando comparada a porcentagem ósseo em OA e b-TCP também não foi encontrada diferença estatística (ANOVA, p=0,794). Em conclusão, os resultados deste estudo indicam que ambos OA e b-TCP são adequados para o uso com segurança para o procedimento de EASM pela técnica da janela lateral. O material sintético apresenta boa estabilidade volumétrica com formação óssea semelhante ao OA suportada pelos parâmetros em análises 2D e 3D que se complementam. No entanto, a metodologia da análise volumétrica utilizada neste estudo parece representar a estabilidade volumétrica geral do procedimento, não somente do biomaterial, quando na técnica for utilizado o enxerto em bloco e não particulado. / The insufficient height of the alveolar bone is a limiting factor for oral rehabilitation with implants. Clinical success rates using beta-tricalcium phosphate (b-TCP) biomaterials for maxillary sinus floor elevation (MSFE) have been shown to be excellent alternatives to autogenous bone (AB). Therefore, the objective was to evaluate bone formation of the b-TCP graft in a block, six months after MSFE, compared to AB by means of tomographic, microtomographic and histomorphometric analyzes. For this, eight maxillary sinuses were grafted with b-TCF and seven AB. After 6 months, biopsies were obtained during the installation of dental implants. There was no significant difference (ANOVA) between the volume contraction of the maxillary sinus filled by AB and b-TCP (p = 0.113), as well as for all microtomographic parameters (ANOVA) BV/TV (p = 0.089), Tb.Th (p = 1.000), Tb.Sp (p = 0.989) and Tb.N (p = 0.917). In histomorphometry, when comparing bone percentage in AB and b-TCP, no statistical difference was found (ANOVA , p = 0.794). In conclusion, the results of this study indicate that both AB and b-TCP are suitable for safe use for the MSFE procedure by the side window technique. The synthetic material presents good volumetric stability with bone formation similar to AB supported by the parameters in 2D and 3D analyzes that complement each other. However, the volumetric analysis methodology used in this study seems to represent the general volumetric stability of the procedure, not only of the biomaterial, when in graft and non-particulate graft technique.
|
10 |
Avaliação microtomográfica e histomorfométrica comparativa de levantamento de seio maxilar em coelhos utilizando diferentes cerâmicas a base de fosfato de cálcio / Comparative microtomographic and histomorphometric evaluation of maxillary sinus augmentation using different calcium phosphate-based ceramicsPaula Sanches dos Santos 25 May 2016 (has links)
A técnica de levantamento de seio maxilar (LSM) visa aumentar a altura óssea junto à superfície sinusal de maxila posterior atrófica utilizando diferentes materiais de preenchimento, para possibilitar a instalação de implantes dentários. Esses materiais de preenchimento podem variar quanto à origem e às propriedades físicoquímicas, resultando em diferentes respostas biológicas. O objetivo do atual trabalho foi avaliar a eficiência do Gen-Ox®inorg e GenPhos XP® na técnica de elevação do seio maxilar em comparação ao Bio-Oss®. Em 24 coelhos foi realizado o levantamento bilateral dos seios maxilares (SMs) utilizando 200 mm3 de material de preenchimento por seio, conforme os grupos experimentais Bio-Oss (6SMs/período), Gen-Ox (5SMs/período) e GenPhos (5SMs/período), e a janela óssea de acesso foi recoberta com uma membrana reabsorvível. Os animais de cada grupo foram eutanasiados aos 15, 30 e 60 dias e a região dos SMs foi coletada e fixada em formalina a 10% tamponada. As peças foram submetidas à análise microtomográfica para determinação do volume total do SM elevado e em seguida ao processamento histológico, sendo cortes coronais dos SMs obtidos e avaliados morfometricamente pelo método de volumetria de pontos. Todos os três materiais apresentaram excelente biocompatibilidade e promoveram a manutenção do volume do seio preenchido ao longo do tempo, sendo em média de 214,1 mm3. Em todos os grupos a formação óssea ocorreu em íntimo contato com as partículas de material. Ao término de 60 dias, o tecido ósseo formado mostrava-se maduro e preenchia parcialmente os espaços entre as partículas. A forma e tamanho das partículas de Gen-Ox gerou maior espaço entre as partículas que pode ter levado a formação de maior volume de tecido ósseo e de tecido conjuntivo (53,0 ± 10,1 mm3 e 74,1 ± 21,5 mm3) comparado ao Bio-Oss (43,7 ± 11,6 mm3 e 61,2 ± 23,3 mm3) e GenPhos (47,5 ± 10,4 mm3 e 58,5 ± 25,7 mm3). Baseado na estabilidade do volume sinusal elevado, na capacidade osteocondutora e na formação e maturidade óssea ao longo do tempo promovidos pelo Gen-Ox®inorg e GenPhos®, comparável ao do Bio-Oss®, conclui-se que esses dois biomateriais significam uma alternativa segura na técnica de LSM. / Maxillary sinus augmentation (MSA) for implant placement using bone graft or bone substitutes is a common procedure to increase the bone volume in the atrophic posterior part of the maxilla. Various bone substitutes have been used in sinus floor elevation procedures. Nonetheless, the biological performance of bone substitutes may vary according to origin, physical and chemical properties. The goal of this study was to evaluate the efficiency of both Gen-Ox®inorg and GenPhos XP® in maxillary sinus augmentation technique compared to Bio-Oss®. In 24 rabbits, it was conducted a bilateral lifting of the maxillary sinuses (MSs) using 200 mm3 of filling material for sinus in accordance with the experimental groups Bio-Oss (6SMs/period), Gen-Ox (5MSs/period) and GenPhos (5MSs/period). The sinus access window was covered with a resorbable membrane. The animals of each group were euthanized at 15, 30 and 60 days and the MSs were collected and fixed in 10% buffered formalin. The samples were submitted to microtomographic analysis to calculate the MS augmentation volume. Histological coronal sections of MS augmentation were used for morphological analysis and determination of volume density of each structure by point counting volumetry method. All three materials had excellent biocompatibility and promoted maintenance of the MS augmentation volume over time, averaging 214.1 mm3. In all groups the bone formation occurred in close contact with the material particles. At the end of 60 days, the bone tissue formed was mature and it partially filled the spaces between the particles. The shape and size of Gen-Ox particles generated greater space between the particles that may have led to a higher formation of bone volume and connective tissue (53.0 ± 10.1 mm3 and 74.1 ± 21.5 mm3) than Bio-Oss (43.7 ± 11.6 mm3 and 61.2 ± 23.3 mm3) and GenPhos (47.5 ± 10.4 mm3 and 58.5 ± 25.7 mm3). Based on the stability of the MS volume, the osteoconductive capacity and the bone formation and maturation over time promoted by Gen-Ox®inorg and GenPhos®, and comparable to Bio-Oss®, it is concluded that these two biomaterials may be a safe alternative in MSA technique.
|
Page generated in 0.1346 seconds