• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Sistema detector de vazamentos em instala??es prediais de ?gua fria

Ara?jo, ?caro Bezerra Queiroz de 30 January 2015 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2016-02-22T21:52:17Z No. of bitstreams: 1 IcaroBezerraQueirozDeAraujo_DISSERT.pdf: 4303113 bytes, checksum: 5b62bbefe395aa81a970303e398aa064 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2016-02-23T23:56:53Z (GMT) No. of bitstreams: 1 IcaroBezerraQueirozDeAraujo_DISSERT.pdf: 4303113 bytes, checksum: 5b62bbefe395aa81a970303e398aa064 (MD5) / Made available in DSpace on 2016-02-23T23:56:53Z (GMT). No. of bitstreams: 1 IcaroBezerraQueirozDeAraujo_DISSERT.pdf: 4303113 bytes, checksum: 5b62bbefe395aa81a970303e398aa064 (MD5) Previous issue date: 2015-01-30 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Instala??es prediais de ?gua fria s?o partes fundamentais em qualquer modelo de habita??o, sejam resid?ncias ou condom?nios. Por?m, tais sistemas est?o sujeitos a falhas, que podem variar desde um vazamento em um aparelho, at? falhas na estrutura dos reservat?rios de ?gua e sistema de distribui??o. Estas falhas s?o respons?veis por altos custos econ?micos e ambientais. Visando reduzir estas perdas, este trabalho prop?e o desenvolvimento de um sistema capaz de detectar a presen?a e identificar alguns tipos de vazamentos de ?gua que venham a ocorrer. Para implementa??o e testes, no simulador desenvolvido, foi utilizado um modelo de consumo capaz de reproduzir o comportamento semelhante ao processo real, assim como suas consequentes falhas. A detec??o dos vazamentos ? feita com base em um modelo semelhante a um sistema especialista que possui dois m?dulos de detec??o, um passivo e outro ativo, os quais utilizam sensores e atuadores (v?lvulas). Para teste e implementa??o, foi desenvolvido um software capaz de acoplar o sistema simulador e o detector. A partir dos resultados obtidos nota-se que o sistema proposto neste trabalho, al?m de funcionar de forma satisfat?ria, pode ser facilmente implementando em microcontroladores ou sistemas embarcados devido a sua simplicidade. / Building installations of cold water are key parts in any model of housing, are homes or condos. However, these systems are subject to failure, which can range from a leak in a device until faults in the structure of water reservoirs and distribution system. These faults are responsible for great economic and environmental costs. In order to reduce these losses, this work proposes the development of a system able to detect the presence and identify some types of water leaks that may occur. For implementation and testing, consumption model was used in a simulator capable of reproducing a similar behavior to a real model and its consequent failures. The detection of leaks is done based on an expert like model having two detection modules, one active and one passive, which use an array of sensors and actuators (valves) to do the sensing. For testing and implementation has been developed a software capable of coupling the system simulator and detector. From the results it can be seen that the system proposed in this work, as well as functioning satisfactorily, can be easily implemented in microcontrollers or embedded systems due to its simplicity.
2

Metodologia para aferi??o do n?vel de maturidade associado ? interoperabilidade t?cnica nas a??es de Governo Eletr?nico / Assessment methodology for E-Government technical interoperability maturity level

Corr?a, Andreiwid Sheffer 23 November 2012 (has links)
Made available in DSpace on 2016-04-04T18:31:32Z (GMT). No. of bitstreams: 1 Andreiwid Sheffer Correa.pdf: 4501821 bytes, checksum: 3d9f7fecc118ff0dc70b11ea481d5e67 (MD5) Previous issue date: 2012-11-23 / The unstructured and unplanned implementation of technological solutions leads to wastage of resources and imposes itself as a barrier to achieving the potential benefits of information technologies and communication. The problem increases when managers who operate these technologies are part of the public administration, as structural issues make this scenario open for merely temporary, strictly proprietary, experimental or doomed to obsolescence solutions, resulting in interoperability problems. Thus, the possible damage extrapolates financial issues and compromise expected social return. In an attempt to avoid this problem, several countries are developing and adopting government interoperability frameworks to guide their actions in electronic government. These architectures expose successful solutions for technical, semantic and organizational dimension of interoperability, and reflect on the best path according to the understanding of its government. However, specifically for the technical dimension, there is no way to evaluate the effectiveness of these architectures and assess how the solutions are interoperable. This work aims to propose a maturity model for technical interoperability in order to assess the use of standards and assist software and systems engineers, as well as professionals in general, to focus their efforts on the use of recommended technologies by good practices. It has been based on e-PING architecture, which is the Brazilian standard for interoperability. In addition, this work proposes the development and use of a rule-based system that implements fuzzy logic to assist evaluation and adherence to the model. To verify model feasibility and validate the developed system, this paper also uses a real scenario as the basis of analysis of interoperability. / A implementa??o desestruturada e n?o planejada de solu??es tecnol?gicas ? fonte de desperd?cio de recursos e imp?e-se como barreira para obten??o dos potenciais benef?cios do uso das tecnologias da informa??o e comunica??o. O problema acentua-se quando gestores dessas tecnologias atuam para a administra??o p?blica, pois quest?es estruturais fazem com que este cen?rio abra espa?o para solu??es pontuais e transit?rias, estritamente propriet?rias, experimentais ou fadadas ? obsolesc?ncia, o que resulta em problemas de interoperabilidade. Desse modo, os poss?veis danos extrapolam o sentido financeiro por comprometer o retorno social esperado. Na tentativa de contornar essa quest?o, v?rios pa?ses v?m desenvolvendo e adotando as arquiteturas de interoperabilidade governamentais para orientar suas a??es de governo eletr?nico. Essas arquiteturas buscam evidenciar, a partir dos aspectos t?cnicos, sem?nticos ou organizacionais, as solu??es bem sucedidas e aceitas universalmente, al?m de refletirem o melhor caminho para a interoperabilidade, segundo o entendimento de cada governo. No entanto, especificamente para o aspecto t?cnico, n?o existe um meio para avaliar a efetiva utiliza??o dessas arquiteturas e aferir o qu?o interoper?veis as solu??es se encontram. Este trabalho visa propor um modelo de maturidade para interoperabilidade t?cnica com o objetivo de medir o uso de padr?es de interoperabilidade e auxiliar engenheiros de softwares e de sistemas, assim como profissionais em geral, a direcionar seus esfor?os no emprego de tecnologias consagradas pelas boas pr?ticas de mercado. Tem-se, como base para a constru??o do modelo, a arquitetura e-PING, que ? o padr?o brasileiro de interoperabilidade. Adicionalmente, este trabalho prop?e o desenvolvimento e utiliza??o de um sistema baseado em regras que emprega l?gica nebulosa para auxiliar no processo de avalia??o da ader?ncia ao modelo. Para verifica??o da viabilidade do modelo e valida??o do sistema desenvolvido, este trabalho tamb?m utiliza um cen?rio real para servir de base de an?lise da interoperabilidade.
3

FUZZYVISA: modelo de avaliação de risco da vigilância sanitária para inspeção de resíduos de serviços de saúde utilizando lógica Fuzzy / FUZZYVISA: model risk assessment of the sanitary inspection of waste health services using Fuzzy logic

Natércia Fonseca de Carvalho da Silva 25 March 2010 (has links)
Este trabalho apresenta um modelo de inspeção sanitária, utilizando lógica fuzzy, sobre gerenciamento de resíduos de serviços de saúde, construído com as informações e experiência de especialista, baseadas nas inspeções de estabelecimentos assistenciais de saúde no Estado do Rio de Janeiro. A partir da estruturação de regras utilizadas na inspeção sanitária sobre Resíduos de Serviços de Saúde (RSS), e do regulamento técnico sobre gerenciamento de RSS, a RDC 306/04 da ANVISA, foi construído um modelo que simula a atuação de um agente especialista da vigilância sanitária, contemplando os elementos difusos que compõem os fatores analisados na inspeção sanitária. O objetivo deste trabalho é apresentar um instrumento, estruturado com base na prática da inspeção sanitária sobre gerenciamento de RSS, utilizando a lógica fuzzy, capaz otimizar a inspeção, gerar indicadores de controle sanitário que permitam monitorar a condição satisfatória do gerenciamento destes resíduos, dar aporte ao planejamento das ações de vigilância sanitária sobre os RSS e acima de tudo propor um instrumento que possa reverter-se em mecanismo eficiente de fiscalização sanitária. O modelo fuzzy foi desenvolvido com uso do software Matlab 2007b, sendo testado com dados de 10 relatórios de inspeções realizadas no período de maio a novembro de 2009. / This study shows a health inspections model of waste management of health establishments in Rio de Janeiro state. The model was built by fuzzys logic and with experts information. It was based in ANVISA rules about waste management in health services: RSS, a RDC 306/04. It makes a simulation of an expert actuation with the diffuse elements of health inspection. The objective of this study is to show a health inspection management waste practice structured instrument, using fuzzys logic, able to optimize the inspection, produce indicators of health control to monitor the satisfactory condition of healh services waste management and guide the planning actions. The fuzzy model was developed with Matlab software and tasted with 10 inspection reports dated of 2009, between may and november.
4

Sistema Especialista para Supress?o Online de Alarmes em Processos Industriais

Souza, Danilo Curvelo de 01 February 2013 (has links)
Made available in DSpace on 2014-12-17T14:56:12Z (GMT). No. of bitstreams: 1 DaniloCS_DISSERT.pdf: 3897603 bytes, checksum: cd98fa05a1dee36b5186c50e95b2f03b (MD5) Previous issue date: 2013-02-01 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / Operating industrial processes is becoming more complex each day, and one of the factors that contribute to this growth in complexity is the integration of new technologies and smart solutions employed in the industry, such as the decision support systems. In this regard, this dissertation aims to develop a decision support system based on an computational tool called expert system. The main goal is to turn operation more reliable and secure while maximizing the amount of relevant information to each situation by using an expert system based on rules designed for a particular area of expertise. For the modeling of such rules has been proposed a high-level environment, which allows the creation and manipulation of rules in an easier way through visual programming. Despite its wide range of possible applications, this dissertation focuses only in the context of real-time filtering of alarms during the operation, properly validated in a case study based on a real scenario occurred in an industrial plant of an oil and gas refinery / A opera??o de processos industriais vem se tornando mais complexa ao longo dos anos, e um dos elementos que possibilitam este aumento de complexidade ? a integra??o de novas tecnologias e solu??es inteligentes empregadas no setor, como ? o caso dos sistemas de apoio ? decis?o. Neste sentido, esta disserta??o visa o desenvolvimento de um sistema de aux?lio ? opera??o baseado em uma ferramenta computacional chamada de sistema especialista. O objetivo principal ? tornar a opera??o mais confi?vel e segura ao maximizar a quantidade de informa??es relevantes a cada situa??o atrav?s da utiliza??o de um sistema especialista baseado em regras pr?-moldadas para uma determinada ?rea de conhecimento. Para a modelagem de tais regras foi proposto um ambiente de alto-n?vel, que permite a cria??o e manipula??o de regras de forma facilitada atrav?s de programa??o visual. A despeito de sua ampla gama de poss?veis aplica??es, esta disserta??o tem como foco o contexto de filtragem em tempo real de alarmes durante a opera??o, devidamente validada em um estudo de caso baseado em um cen?rio real ocorrido em uma planta industrial de uma refinaria de petr?leo e g?s
5

FUZZYVISA: modelo de avaliação de risco da vigilância sanitária para inspeção de resíduos de serviços de saúde utilizando lógica Fuzzy / FUZZYVISA: model risk assessment of the sanitary inspection of waste health services using Fuzzy logic

Natércia Fonseca de Carvalho da Silva 25 March 2010 (has links)
Este trabalho apresenta um modelo de inspeção sanitária, utilizando lógica fuzzy, sobre gerenciamento de resíduos de serviços de saúde, construído com as informações e experiência de especialista, baseadas nas inspeções de estabelecimentos assistenciais de saúde no Estado do Rio de Janeiro. A partir da estruturação de regras utilizadas na inspeção sanitária sobre Resíduos de Serviços de Saúde (RSS), e do regulamento técnico sobre gerenciamento de RSS, a RDC 306/04 da ANVISA, foi construído um modelo que simula a atuação de um agente especialista da vigilância sanitária, contemplando os elementos difusos que compõem os fatores analisados na inspeção sanitária. O objetivo deste trabalho é apresentar um instrumento, estruturado com base na prática da inspeção sanitária sobre gerenciamento de RSS, utilizando a lógica fuzzy, capaz otimizar a inspeção, gerar indicadores de controle sanitário que permitam monitorar a condição satisfatória do gerenciamento destes resíduos, dar aporte ao planejamento das ações de vigilância sanitária sobre os RSS e acima de tudo propor um instrumento que possa reverter-se em mecanismo eficiente de fiscalização sanitária. O modelo fuzzy foi desenvolvido com uso do software Matlab 2007b, sendo testado com dados de 10 relatórios de inspeções realizadas no período de maio a novembro de 2009. / This study shows a health inspections model of waste management of health establishments in Rio de Janeiro state. The model was built by fuzzys logic and with experts information. It was based in ANVISA rules about waste management in health services: RSS, a RDC 306/04. It makes a simulation of an expert actuation with the diffuse elements of health inspection. The objective of this study is to show a health inspection management waste practice structured instrument, using fuzzys logic, able to optimize the inspection, produce indicators of health control to monitor the satisfactory condition of healh services waste management and guide the planning actions. The fuzzy model was developed with Matlab software and tasted with 10 inspection reports dated of 2009, between may and november.
6

Descoberta de causa-raiz em ocorrências de sistemas elétricos. / Root cause discovery in occurrences of electrical systems.

PIRES, Stéfani Silva. 16 August 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-08-16T13:58:48Z No. of bitstreams: 1 STEFANI SILVA PIRES - DISSERTAÇÃO PGCC 2010..pdf: 819684 bytes, checksum: 625f468cb174d699bf5b98131d1adf61 (MD5) / Made available in DSpace on 2018-08-16T13:58:48Z (GMT). No. of bitstreams: 1 STEFANI SILVA PIRES - DISSERTAÇÃO PGCC 2010..pdf: 819684 bytes, checksum: 625f468cb174d699bf5b98131d1adf61 (MD5) Previous issue date: 2010-08-19 / Este trabalho apresenta uma técnica de análise de causa-raiz para sistemas elétricos de potência. A análise de causa-raiz é uma forma de auxiliar o operador na compreensão da ocorrênciadefalha,interpretandoasocorrênciascomefeito"cascata"entreoselementosda rede. A técnica proposta utiliza o raciocínio baseado em regras, onde regras parametrizadas constroem um modelo de propagação com os diagnósticos de uma ocorrência de falha. A técnica permite apontar o elemento causador da ocorrência, e detalhar a sua propagação para os demais elementos em um modelo de causa-efeito. A utilização de regras parametrizadas traz grandes vantagens ao processo, permitindo que a técnica seja adaptável a alterações na topologia do sistema, e contribuindo para sua escalabilidade. Um estudo de caso foi elaborado para sua avaliação, no contexto da Companhia Hidro Elétrica do São Francisco (CHESF), onde foi desenvolvido um protótipo que implementa a técnica, e levantados um conjunto de regras parametrizadas e um conjunto de cenários de falha utilizando uma ferramenta de simulação de um ambiente real, o Simulop. Utilizamos também na avaliação, um conjunto de regressões, que são dados históricos armazenados pela CHESF. As regressões foramimportantesnaprimeirafasededefiniçãodatécnica,masapresentamproblemascomo afaltadedados,ecomportamentosinesperadosdosistema,ondeamargemdeacertodatécnica foi de 74%. Para o conjunto de cenários levantados com oSimulop, a técnica proposta conseguiu realizar com sucesso o processo de análise de causa-raiz, identificando a causaraiz da ocorrência em 100% dos cenários de falha, e detalhando sua propagação para todos os outros elementos da rede envolvidos em 89% dos cenários, onde a margem de erro é composta de cenários cuja propagação foi identificada apenas parcialmente, devido à falta de regras que contemplassem os cenários. Dessa forma, a técnica proposta se mostrou uma abordagem viável para a análise de causa-raiz em sistemas elétricos. A margem de acerto reduzida nas regressões, indica que, para ser aplicada em um ambiente operacional real, faz-se necessária a elaboração de um conjunto de regras mais abrangente e que possa contornar esses problemas. / This paper presents a root cause analysis technique for electric power systems. The root cause analysis is a way to assist the operator in understanding the occurrence of failure, interpreting the events cascade occurrences. The proposed technique uses a rule based reasoning, where parameterized rules construct a propagation model with diagnosis of an occurrence of failure. The technique allows to point out the element that causes the occurrence, and detailing its propagation to other elements in a cause and effect model. The use of parameterized rules brings major benefits to the process, allowing the technique to be adaptable to changes in system topology, and contributing to its scalability A case study was prepared for evaluation in the context of the Companhia Hidro Elétrica do São Francisco (CHESF). We developed a prototype that implements the technique, and raised a set of parameterized rules and a set of failure scenarios using a tool to simulate a real environment, the Simulop. We also used in the evaluation process, a set of regressions, which are historical data stored by CHESF. The regressions were important in the first phase of the technique, but they have problems such as lack of data, and unexpected behavior of the system, where the accuracy of the technique was 74%. For the set of scenarios created with Simulop, the proposed technique has achieved success in the root cause analysis process, identifying the root cause of the occurrence in 100% of failure scenarios, and detailing their propagation to all other equipments involved in 89% of scenarios, where the margin of error is composed of scenarios whose propagation has been identified only in part due to the lack of rules that contemplate these scenarios. Thus, the proposed technique proved to be a viable approach to root cause analysis in electrical systems. The reduced margin of success in the regressions , indicates that, to be applied to an operational environment, it is necessary to elaborate a comprehensive set of rules that can deal these problems.

Page generated in 0.1012 seconds