• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Evaluación comparativa entre sistemas estructurales tradicionales de concreto armado vs estructura con aislación sísmica en base para el Hospital Huari de categoría II-1 en Ancash / Comparative evaluation between traditional structural systems of reinforced concrete vs structure with seismic isolation based on the Huari Hospital category II-1 in Ancash

Márquez Antaurco, Edwin, Velarde Arellano, Omar Flavio 08 July 2020 (has links)
El Perú se encuentra en una zona altamente sísmica, ubicado dentro del cinturón de fuego del pacífico, que contempla aproximadamente el 85% de la actividad sísmica mundial. En nuestro país no existe un historial de eventos sísmicos por lo que, nuestra investigación consiste en la restructuración de una edificación hospitalaria categoría II, de 3 niveles con aislación sísmica en la base, sobre un suelo intermedio; en el distrito y provincia de Huari, Ancash. Se evaluará la viabilidad de construir edificaciones hospitalarias con el método tradicional con el fin de que la entidad pueda elegir la opción que mejor le convenga para su ejecución. Dado que, en nuestro país no existe mayor información cuantitativa y comparativa del comportamiento de hospitales con aislación o sin aislación sísmica para establecer u obligar el uso de aisladores en infraestructuras hospitalarias. Adicionalmente, existen antecedentes de hospitales que fueron diseñados y construidos con el actual código sísmico nacional y que luego de un evento sísmico siguieron operativos. El análisis comparativo, demuestra la capacidad del sistema tradicional que diseñado adecuadamente tendrá la capacidad de cumplir con las exigencias de eventos sísmicos severos, manteniéndose así operativo luego de un sismo; por lo tanto, el sistema aislado sería una solución costosa para un problema sencillo. Sin embargo, el actual código sísmico peruano exige el uso de aisladores sísmicos para toda edificación hospitalaria, especialmente en zonas sísmicas 4 y 3. / Peru is located in a highly seismic zone, located within the Pacific ring of fire, which accounts for approximately 85% of the world's seismic activity. In our country there is no history of seismic events, therefore, our investigation consists of the restructuring of a category II hospital building, with 3 levels with seismic isolation at the base, on an intermediate floor; in the district and province of Huari, Ancash. The feasibility of building hospital buildings with the traditional method will be evaluated so that the entity can choose the option that best suits it for its execution. Given that in our country there is no more quantitative and comparative information on the behavior of hospitals with or without seismic isolation to establish or force the use of isolators in hospital infrastructures. Additionally, there is a history of hospitals that were designed and built with the current national seismic code and that continued operating after a seismic event. The comparative analysis demonstrates the capacity of the traditional system, which, properly designed, will have the capacity to meet the demands of severe seismic events, thus remaining operational after an earthquake; therefore, the isolated system would be an expensive solution to a simple problem. However, the current Peruvian seismic code requires the use of seismic isolators for all hospital buildings, especially in seismic zones 4 and 3. / Tesis
2

Elemento estructural mixto de hormigón y madera. Análisis estructural y criterios de diseño

Martínez Juan, Bernardo 22 July 2016 (has links)
El interés por las estructuras mixtas de hormigón y madera está plenamente justificado por su aplicación técnica en rehabilitación de forjados antiguos de madera, en nuevos forjados o en cualquier otra tipología estructural al amparo, entre otros, de criterios ambientales y de sostenibilidad, al ser la madera un material de menor coste energético que los clásicos hormigón o acero. En éste tipo de estructuras la conexión entre materiales es la que hace posible el trabajo conjunto de todos ellos. En la presente tesis se ha realizado una revisión pormenorizada de las características mecánicas de los conectores utilizados para este tipo de estructuras, en términos de resistencia a esfuerzo rasante, rigidez y modo de rotura, encontrando que estas propiedades mecánicas son manifiestamente mejorables. A partir de una idea preconcebida, se realizan ensayos con el material necesario y se desarrolla el diseño de un nuevo conector que, colocado inclinado respecto del plano de contacto entre materiales, trabaja a flexotracción y supera los inconvenientes de los precedentes. Se analiza con detalle cuáles han de ser sus características geométricas y cuáles son las propiedades mecánicas de la conexión resultante. Se comparan estas propiedades con las de algunas de las conexiones precedentes encontrando que su resistencia por unidad de área es superior a la de cualquier conexión anterior. Además con dicha disposición se moviliza un rozamiento en el plano de contacto que es en parte responsable de esas altas propiedades mecánicas conjuntas Mediante otra serie de ensayos se evalúa experimentalmente la magnitud del coeficiente de rozamiento para distintos acabados superficiales y sucesivos ciclos de carga. Se obtiene que la resistencia a rasante aportada por el rozamiento potencial puede llegar a ser del mismo orden que la propia resistencia del elemento en la dirección del deslizamiento. Se han fabricado dos prototipos de forjado mixto a escala real unidos con las conexiones diseñadas y se ensayan a flexión simple analizando su comportamiento, registrando en ambos casos las flechas resultantes en centro de vano. A partir de la teoría clásica de estructuras mixtas, se ha desarrollado un modelo matemático para el comportamiento a flexión del forjado con conexiones cuyo comportamiento rasante-deslizamiento se encuentra en rango elástico lineal, elastoplástico o plástico. Se ha aplicado a la conexión diseñada y, a pesar de las hipótesis realizadas para su desarrollo, el modelo predice con suficiente aproximación las flechas observadas y es, por tanto, una buena herramienta de diseño de los forjados de hormigón-madera.

Page generated in 0.0627 seconds