Spelling suggestions: "subject:"cistemas dde energia elétrica"" "subject:"cistemas dee energia elétrica""
191 |
Analise da estabilidade de tensão e areas criticas da rede eletrica do Estado de São Paulo / Assessment of voltage stability critical areas of São Paulo State transmission networkSilva, Luciano Jose da 20 December 2006 (has links)
Orientador: Luiz Carlos Pereira da Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-08T01:32:40Z (GMT). No. of bitstreams: 1
Silva_LucianoJoseda_M.pdf: 4123648 bytes, checksum: 8230dacb74058918f80eb46ac227e7d6 (MD5)
Previous issue date: 2006 / Resumo: O objetivo desta dissertação é investigar o grau de segurança da rede elétrica do Estado de São Paulo em relação ao risco da ocorrência de colapso de tensão. São considerados no estudo um número significativo de casos base (N-0) e casos com contingências simples (N-1). Métodos baseados no cálculo de curvas PV são utilizados para a avaliação das margens de estabilidade dos diferentes cenários de operação. No entanto, estes métodos não propiciam a identificação de barras ou áreas críticas do sistema do ponto de vista da estabilidade de tensão, as quais representam as melhores opções para a aplicação de medidas de reforço e/ou corretivas contra o problema de instabilidade. A técnica de análise modal é aplicada para a identificação de áreas críticas em relação à estabilidade de tensão, permitindo capturar as regiões da rede elétrica do Estado de São Paulo que requerem maior
atenção. Utilizando a metodologia de análise modal foi ainda possível verificar a abrangência das contingências capturadas através do método da curva PV, possibilitando mensurar o impacto de cadacontingência como local, de área ou sistêmico. Os resultados desta pesquisa permitem concluir que a malha principal do Estado é redundante, não havendo a perda sistêmica da estabilidade de tensão para cenários de contingências simples / Abstract: This work investigates the security level of the transmission network of the State of São Paulo with respect to the occurrence of voltage collapse. A number of credible scenarios including base cases (N-0) and single contingency (N-1) cases are considered. PV curve methods are employed for evaluating the voltage stability margin for the selected set of operative scenarios. However, these methods do not provide the identification of critical buses or areas from the perspective of voltage stability, which represent the best options for the application of reinforcement/corrective measures against the instability problem. The modal analysis technique is applied for the identification of critical areas with respect to voltage instability, allowing the selection of the areas of the grid that request special attention. The modal analysis method also provide the means of quantifying the impact area of the contingencies captured through the PV curve method, providing a way of separating a set of credible contingencies into three groups as far as their impact: branch-wide contingencies, area-wide contingencies and system-wide contingencies. The results of this research leads to the conclusion that the main transmission network of the State of São Paulo is redundant, since no cases occurred of systemic loss of voltage stability due to single contingencies / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
|
192 |
Controle integrado de tensão e potência reativa através de aprendizado de máquina / Integrated voltage and reactive power control using machine learningPinto, Adriano Costa, 1989- 27 August 2018 (has links)
Orientador: Walmir de Freitas Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-27T12:29:12Z (GMT). No. of bitstreams: 1
Pinto_AdrianoCosta_M.pdf: 2073375 bytes, checksum: e1c68a8598816ca4909e74ba53dee76d (MD5)
Previous issue date: 2015 / Resumo: A crescente demanda por energia elétrica, por vezes em ritmo mais acelerado que os investimentos em expansão das redes de distribuição, tem levado as distribuidoras a operarem próximo aos limites aceitáveis, o que torna toda a operação da rede mais complexa. Um dos desafios atuais é estabelecer um efetivo controle de tensão e potência reativa (Volt/var) na rede buscando melhorar o nível de operação e de eficiência energética da rede. Muitas propostas para encontrar a solução do problema partiram de uma abordagem de forma desacoplada: o controle de tensão e o controle de potência reativa foram resolvidos separadamente. Neste trabalho, porém, foram estudados métodos de solução do problema visando à segurança da operação e à otimização global dos recursos da rede de modo integrado, ou seja, considerando a dependência entre tensão e potência reativa. Na literatura, grande parte dos trabalhos reportam soluções baseadas em modelos elétricos da rede de distribuição. Os métodos estudados nessa dissertação são baseados em técnicas de aprendizado de máquina com o objetivo de construir um modelo capaz de utilizar apenas as medições de tensão e corrente provenientes dos medidores instalados ao longo da rede e obter o melhor despacho dos ajustes dos dispositivos de controle, sem a necessidade de um modelo elétrico do sistema. A grande vantagem de não depender dos dados e modelo elétrico do sistema está associada às imprecisões tipicamente existentes na base de dados elétricos das concessionárias de distribuição de energia elétrica. Neste contexto, primeiramente, propõe-se o uso de aprendizado por reforço, no qual o agente interage com a rede enquanto acumula experiência de operação dos controles. A implementação através do algoritmo Q-Learning permite a construção de um operador virtual da rede de distribuição a partir dos dados provenientes dos medidores instalados em determinadas barras do sistema, dos quais é extraído o estado corrente da condição de carregamento da rede. Os principais aspectos da aplicação do método ao problema de controle integrado de tensão e potência reativa são simulados em redes típicas e as capacidades de aplicação prática ao cenário atual do sistema elétrico são discutidas. Em uma segunda etapa, propõe-se utilizar um algoritmo de aprendizado supervisionado através de Máquinas de Vetores de Suporte (em inglês, Support Vector Machine ¿ SVM), uma técnica eficientemente aplicada a problemas de mineração de dados. O modelo é implementado através de técnicas de classificação, que extraem características relevantes nos conjuntos de dados, a fim de otimizar a operação da rede para cada condição de carregamento, eliminando a necessidade de repetir o treinamento do modelo ou calcular uma nova solução do problema de otimização a cada novo cenário. Discute-se o desempenho do método baseado em SVM para diferentes características de entrada. Investiga-se ainda a generalização do modelo proposto na presença de ruídos nos dados e no caso de reconfiguração da rede. Estudos em sistemas típicos de distribuição mostram que o método proposto é eficiente na solução de problemas práticos do dia-a-dia das concessionárias, principalmente em ambientes com grande volume de dados / Abstract: The growing demand for electricity, sometimes at a faster rate than investments in distribution network expansion, has led utilities operating close to acceptable limits, which makes the network operation more complex. One of current challenges is to establish an effective voltage and reactive power control, improving the operation as well as the efficiency of the distribution network. There are many methods reported to find a solutions for the voltage and reactive power problem. Most of them have adopted a decoupled form, solving the voltage control and reactive power (Volt/var) control separately. However, in this work, methods for the problem solution aiming the operation safety and the global assets optimization are approached in an integrated fashion, i. e., considering the dependence between voltage and reactive power. Most papers reports solution based on electrical models of distribution network. In this dissertation, the methods studied are based on machine learning techniques aiming to build a model with directly power meter data using capability, and set optimal dispatch of controls devices adjustments, without the need of an electrical model of the system and, therefore, not susceptible to inaccuracies of the model of the distribution network under study. Firstly, it proposes a reinforcement learning use, in which the agent interacts with the network while earns control operating experience. The implementation, thought de Q-Learning algorithm allows a construction of a distribution network virtual operation from data obtained from the meters installed on buses. From the meter data, is extracted the current state of the network loading condition. The main aspects of the application of the method to the integrated voltage and reactive power control are simulated in a typical network and the possibilities of practical application in the current scenario of the electrical system are discussed. In a second step, an algorithm for supervised learning via the Support Vector Machine (SVM), a technique applied efficiently to problems in data mining is proposed. The model is implemented by classification techniques, extracting relevant features in the data sets from the power meters in order to optimize the operation of the network for each loading condition. Thus it eliminates the need to retraining model or calculating a new optimization problem solution for each new scenario. Discusses the performance based on different features for SVM model input. Also the generalization capabilities of the proposed model in the presence of noise and in the case of network reconfiguration are studied. Studies in typical distribution systems show that proposed method is a good candidate to solve the practical problem of the system, especially in large networks with large amounts of data / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
|
193 |
Avaliação termoeconomica de um sistema de cogeração proposto para um polo industrialGuarinelo Júnior, Flávio Fernando 08 September 1997 (has links)
Orientador: Silvia Azucena Nebra de Perez / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-23T05:59:33Z (GMT). No. of bitstreams: 1
GuarineloJunior_FlavioFernando_M.pdf: 13289619 bytes, checksum: 071272a1f97f1b5a7cc53461f4f94b0e (MD5)
Previous issue date: 1997 / Resumo: Este trabalho trata da aplicação de conceitos da termoeconomia à um estudo preliminar de um sistema de cogeração baseado em turbina a gás aeroderivativa e caldeira de recuperação, que visa suprir as demandas térmica e elétrica de um pólo industrial situado na cidade de Cabo -PE. É introduzida a análise energética, exergética e termoeconomica, para avaliar as eficiências segundo métodos e critérios específicos à sistemas de potência, para duas situações hipoteticamente admitidas quanto ao nível de geração de eletricidade - com e sem injeção de vapor na turbina a gás, que representam os perfis médios de demanda, segundo o fator de capacidade apresentado. Na análise termoeconôrnica são introduzidos alternativas de financiamento que possibilitam avaliar os reflexos dos custos de capital e combustível na composição dos custos da eletricidade e do vapor, segundo os métodos de alocação passíveis de serem aplicados a sistemas de cogeração. As alternativas de financiamento são ainda submetidas à técnicas conhecidas de análise de investimentos / Abstract: The main purpose of this work is to apply the Thermoeconomics concepts to a preliminary study of a cogeneration system, based on a gas turbine and HRSG, which objects to attend the thermal and electrical demand of an industrial complex, sited in Cabo-PE. The power plant is evaluated on the basis of the First and Second Law. Also the Thermoeconomic analysis, was applied for two hypothetical operation conditions, as regards the leveI of electric power generation - with and without steam injection in the gas turbine, which represents the middle demand outline, according to presented capacity factor. In the thermoeconomic analysis is introduced project finance options generally used in Brasil, what permits an evaluation of capital and fuel costs considering in the electricity and steam costs, according to allocation methods susceptible to be applied in cogeneration systems. The financirtg options, are subjected to known technics of investments analysis / Mestrado / Energia / Mestre em Engenharia Mecânica
|
194 |
Gestão estratégica de energia elétrica e seus reflexos no desenvolvimento regional /Bagattoli, Sandro Geraldo, Deschamps, Eduardo, Universidade Regional de Blumenau. Programa de Pós-Graduação em Desenvolvimento Regional. January 2005 (has links) (PDF)
Orientador: Eduardo Deschamps. / Dissertação (mestrado) - Universidade Regional de Blumenau, Centro de Ciências Humanas e da Comunicação, Programa de Pós-Graduação em Desenvolvimento Regional.
|
195 |
Múltiplos controladores aplicados ao conversor BOOST CC-CC operando com larga faixa de carga :uma abordagem baseada em algoritmo genético e lógica FUZZY /Dupont, Fabrício Hoff, Oliveira, Sérgio Vidal Garcia, 1974-, Montagner, Vinícius Foletto, Universidade Regional de Blumenau. Programa de Pós-Graduação em Engenharia Elétrica. January 2010 (has links) (PDF)
Orientador: Sérgio Vidal Garcia Oliveira. / Co-orientador: Vinícius Foletto Montagner. / Dissertação (mestrado) - Universidade Regional de Blumenau, Centro de Ciências Tecnológicas, Programa de Pós-Graduação em Engenharia Elétrica.
|
196 |
Desenvolvimento de um simulador de redes elétricas para estudos da propagação de harmônicosLIMA, Diorge de Souza 23 August 2016 (has links)
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-01-04T13:44:49Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_DesenvolviementoSimuladorRedes.pdf: 3993762 bytes, checksum: d833db03c025ab4cf9cb2cc2e7498a7e (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-01-10T17:41:03Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_DesenvolviementoSimuladorRedes.pdf: 3993762 bytes, checksum: d833db03c025ab4cf9cb2cc2e7498a7e (MD5) / Made available in DSpace on 2017-01-10T17:41:03Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_DesenvolviementoSimuladorRedes.pdf: 3993762 bytes, checksum: d833db03c025ab4cf9cb2cc2e7498a7e (MD5)
Previous issue date: 2016-08-23 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O setor elétrico brasileiro tem enfrentado grandes mudanças devido a modernização dos equipamentos elétricos, principalmente quando se refere aos consumidores residenciais. Isso tem proporcionado um aumento considerável do nível de distorção de harmônicos nas redes elétricas de distribuição, o que pode ser justificado pelo uso acentuado de equipamentos baseados na eletrônica de potência, na tentativa de torná-los cada vez mais eficientes e compactos. Portanto, torna-se necessário a realização de diagnóstico quanto aos níveis de distorções harmônicas em sistemas elétricos. O monitoramento por analisadores de energia é a melhor forma de obter os dados do sistema elétrico, entretanto a simulação computacional é uma eficiente ferramenta capaz de reproduzir os distúrbios e o comportamento da rede elétrica para diferentes modos de operação. Logo, este trabalho tem como objetivo apresentar um ambiente computacional que auxilie nos estudos de propagação de harmônicos nos sistemas elétricos. Para isso, utilizou-se o software ATP (Alternative Transient Program) para a modelagem do sistema elétrico, o comportamento harmônico de uma carga não linear é representado por valores eficazes de medidas de correntes harmônicas em função do tempo. As medidas foram obtidas por meio de analisares de qualidade da energia conectados em uma rede de distribuição da região norte do Brasil. Logo, para esse conjunto de medidas, foi realizado um conjunto de simulações, disponibilizando ao usuário valores de tensões harmônicas para todos os barramentos do sistema elétrico. Portanto, com o simulador de redes elétricas será possível realizar estudos de propagação de harmônicos em diversos sistemas elétricos, podendo auxiliar como uma ferramenta de planejamento estratégico quanto ao uso de medidas mitigadoras ou mesmo para o controle estratégico das distorções harmônicas, a partir das avaliações dos principais momentos críticos de distorções harmônicas em todos os pontos da rede elétrica. Para demonstrar a utilização, o sistema industrial de 13 barras foi utilizado como um sistema teste para as análises nesta dissertação. / The electricity sector in Brazil has faced many changes due to the modernization of electrical equipment, especially when it refers to residential consumers. This has provided a considerable increase in the level of harmonic distortion in the electric distribution networks, which can be explained by the large use of devices based on power electronics in an attempt to make them more efficient and compact. Therefore, it becomes necessary execute analysis of the levels of harmonic distortion in the power systems. Monitoring by power quality analyzer is the best way to collect data of the electrical system; however, the computer simulation is an efficient tool capable of reproducing the disturbances and behavior of the electric networks for different operating modes. Thus, this paper aims to present a computational environment that helps the harmonic propagation studies in electrical systems. For this, it was used the software ATP (Alternative Transient Program) for modeling the electrical system, the harmonic behavior of a nonlinear load is represented by effective values of harmonic currents in function of time. The measurements were obtained through power quality analysis of a distribution network in the North Region of Brazil. Thus, for this set of measures, a set of simulations was performed, providing for the users the values of harmonic voltages for all buses of the electrical system. Therefore, with the simulator of electrical networks it is possible perform harmonic propagation studies in several electrical systems, and it can work as a strategic planning tool for the use of mitigating measures or for the strategic control of harmonic distortion, from evaluations of most critical moments of harmonic distortion at all points of the network. To demonstrate its use, the industrial system of 13 bar was used as a test system for analysis in this dissertation.
|
197 |
Projeto de um controlador amortecedor robusto aplicado a um sistema de potência sujeito a incertezas paramétricasCUNHA, Leiliane Borges 16 March 2016 (has links)
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-03-28T12:32:17Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_ProjetoControladorAmortecedor.pdf: 2067411 bytes, checksum: 2542d90e45a2de378970e108dbe724bd (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-28T13:43:43Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_ProjetoControladorAmortecedor.pdf: 2067411 bytes, checksum: 2542d90e45a2de378970e108dbe724bd (MD5) / Made available in DSpace on 2017-03-28T13:43:43Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_ProjetoControladorAmortecedor.pdf: 2067411 bytes, checksum: 2542d90e45a2de378970e108dbe724bd (MD5)
Previous issue date: 2016-03-16 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho apresenta o projeto de um Estabilizador para o amortecimento das oscilações eletromecânicas em sistemas elétricos de potência usando técnicas de controle robusto baseadas em incertezas paramétricas afins. Esses sistemas são representados por modelos que apresentam incertezas em seus parâmetros, referentes às variações das condições de operação. A metodologia de projeto é estruturada de forma a fornecer um estabilizador que forneça o máximo amortecimento ao sistema, especificado por um politopo de polinômios característicos. Para isso, usa-se a técnica de alocação robusta de polos e o teorema de Chebyshev, integrados à solução de técnicas de programação linear, para o projeto do controlador. Esta técnica permite incorporar restrições ao desempenho do sistema, correspondendo às incertezas presentes no sistema, deixando o projeto do controlador mais robusto. Comparações do controlador robusto com um controlador tradicional são feitas a fim de avaliar os resultados obtidos e validar as vantagens do uso de controladores robustos. Os resultados e as comparações são realizados em ambientes de simulação usando o software MATLAB/SIMULINK, que permite modelar e simular todos os tipos de sistemas dinâmicos. / This work presents the design of a Stabilizer for the damping of the electromechanical oscillations in electric power systems using robust control technical based on affine parametric uncertainties. These systems are represented by models that have uncertainties in yours parameters, relating to changes in operating conditions. The project methodology is structured to provide a stabilizer that provides the maximum damping to the system, specified by a polytope of characteristic polynomials. For this, it is used poles robust allocation techniques and Chebyshev's theorem, integrated into the solution of linear programming techniques, for the controller design. This technique allows incorporating restrictions on system performance, corresponding to the uncertainties present in the system, making the controller design more robust. Comparisons of the robust controller with a classic controller are made in order to evaluate the results and validate the advantages of the use of controllers designed by the technique proposal. The results and comparisons are performed in simulation environments using MATLAB / SIMULINK software, which allows to model and simulate all kinds of dynamic systems.
|
198 |
Planejamento de redes de distribuição de energia elétrica de média e baixa tensãoCossi, Antonio Marcos [UNESP] 20 June 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:50Z (GMT). No. of bitstreams: 0
Previous issue date: 2008-06-20Bitstream added on 2014-06-13T20:21:17Z : No. of bitstreams: 1
cossi_am_dr_ilha.pdf: 1798466 bytes, checksum: 3b0c96085dcf5e4f3e999327f4a5b0f4 (MD5) / Fundação de Ensino Pesquisa e Extensão de Ilha Solteira (FEPISA) / Neste trabalho apresentam-se os conceitos teóricos, modelos matemáticos, técnicas de solução e resultados de pesquisas desenvolvidas envolvendo o planejamento de redes de distribuição de energia elétrica de MT e planejamento e projeto de circuitos secundários de BT. O problema de planejamento de redes de MT e planejamento e projetos de circuitos de BT, é abordado através de uma modelagem completa e as propostas de solução são através de “meta heurísticas” mono e multi-objetivos. As restrições consideradas nestes modelos referem-se à radialidade dos sistemas planejados, suprimento da demanda nas barras de consumo em cada estágio do programa de planejamento, limites máximos de queda de tensão permitidos nos alimentadores restrições físicas de operação de equipamentos, condutores e restrições de natureza financeira. O modelo de planejamento de redes de MT é abordado como um problema de programação não linear inteiro misto (PNLIM) multi-objetivo. Os objetivos referem-se aos custos de investimentos e de confiabilidade da rede. Para solução do problema utiliza-se um algoritmo Tabu Search (TS) reativo em que os múltiplos objetivos são considerados através dos conceitos de fronteira ótima de Pareto. Para avaliar as propostas de soluções é utilizado como ferramenta auxiliar um algoritmo de fluxo de potência monofásico. No modelo que trata do problema de planejamento e projetos de circuitos secundários, são considerados tanto ações de planejamentos como de projetos. Para tal é proposta uma metodologia em três etapas seqüenciais: a primeira refere-se ao balanceamento de cargas nas fases abc do circuito, a segunda à localização (Geralmente no centro de cargas), capacidade e quantidade de transformadores abaixadores na rede e a terceira define as rotas e o tipo de cabo dos alimentadores secundários. O modelo é formulado como um problema... / This work presents the theory, the mathematical model, the solution techniques and the results of the developed research dealing with MV (medium voltage) electrical energy distribution network planning and the secondary circuit project of LV (low voltage). The problem of planning MV networks and planning and project LV circuits is approached by a complete modeling and the solution proposals are effectuated by mono and multi objective meta heuristics. The restrictions considered in these models are referred to the radial form of the planned systems, demand supplying on the busses in each stage of the planning program, maximum limits of voltage drops allowed on the feeders, physical restrictions of operation on the equipments and financial restrictions. The planning model of MV network is approached as a multi objective nonlinear integer mist programming problem (NLIMPP). The objectives are referred to the investment costs, and reliability costs. To solve the problem a reactive Tabu Search (TS) algorithm is used where the multiple objectives are considered by the optimal frontier Pareto concept. To evaluate the solution proposals a monophasic power flow algorithm is used as an auxiliary tool. The secondary circuit planning and project models consider as much as planning and project actions. For this a three stage methodology is proposed: the first is referred to load balancing on abc phases of the circuit; the second to the location (generally on the load center) capacity and quantity of lower transformers on the network, and the third defines the directions and the type of the secondary feeders. The model is formulated as a nonlinear integer mist programming problem (NLIMPP), and for the solution is proposed a TS algorithm. To evaluate the solution proposals a three phase power flow with four conductors (three phases and one neutral) is used as an auxiliary algorithm. The integrated... (Complete abstract click electronic access below)
|
199 |
Regulador MPC de tensão e velocidade integrado para unidades geradoras hidrelétricasMenarin, Henrique Augusto January 2013 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia de Automação e Sistemas, Florianópolis, 2013. / Made available in DSpace on 2014-08-06T17:33:48Z (GMT). No. of bitstreams: 1
325188.pdf: 6857768 bytes, checksum: 028cd5e4880d01d901291738cd104bee (MD5)
Previous issue date: 2013 / Um conjunto razoável de objetivos de controle está associado à geração de energia hidrelétrica. Isto envolve o seguimento às referências de tensão, velocidade e potência, o amortecimento de oscilações eletromecânicas e o atendimento a restrições dos atuadores e de capabilidade do gerador. Adicionalmente, o processo é não linear e há acoplamento entre as variáveis controladas. Tradicionalmente, cada objetivo é tratado por malhas de controle específicas, cada qual com seus parâmetros de sintonia. Propõe-se o uso de um Controlador Preditivo baseado em Modelo (MPC) visando a atender todos os objetivos de controle de forma integrada. O controle proposto utiliza um modelo não linear simplificado da unidade geradora para o cálculo das predições. O controlador foi testado em vários cenários em comparação com o esquema de controle convencional. Obteve-se excelente desempenho de controle, sem o uso de malhas auxiliares. Também é discutida a influência dos parâmetros de sintonia sobre a resposta do processo. Verifica-se pelos resultados de simulações que a estratégia proposta é viável e permite melhorar o desempenho do sistema de controle, em comparação com controladores convencionais.<br> / Abstract : A wide set of control objectives is associated with the hydropower generation. This involves the tracking of terminal voltage, speed and active power references, the damping of electromechanical oscillations limitation of the generator operating point and actuators output. Additionally, the controlled process is non-linear and the variables are dynamically coupled. Each control objective is traditionally handled by dedicated control loops, each of them with isolated tuning parameters. The use of a Model Predictive Control (MPC) scheme is proposed as to consider all control objectives in an integrated calculation. The proposed controller uses a simplified non-linear model of the generating unit for calculating the predictions. The controller was tested in various cases, comparing its performance with the conventional control scheme. An excellent control performance was obtained, without need of auxiliar control loops. The influence of the tuning parameters on response characteristics is also discussed. The simulation results indicate that the strategy is viable and can improve the performance of the control system, compared to conventional controllers.
|
200 |
Um modelo de otimização estocástica para o apoio à decisão na comercialização de energia de pequenas centrais hidrelétricasGonzalez Sierra, Mauro Antonio January 2013 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2013. / Made available in DSpace on 2014-08-06T17:34:12Z (GMT). No. of bitstreams: 1
325456.pdf: 2130689 bytes, checksum: 8b174ed0b6403f6bbc4dd79b8d3465ef (MD5)
Previous issue date: 2013 / No Setor Elétrico Brasileiro (SEB), a comercialização de energia é efetivada através de dois ambientes de contratação: o Ambiente de Contratação Regulado (ACR) e o Ambiente de Contratação Livre (ACL). Os agentes de geração podem comercializar sua energia tanto no ACR quanto no ACL com comercializadores e consumidores livres, sendo que uma pequena parcela denominada de fontes incentivadas pode vender também para consumidores especiais. Dentre as fontes incentivadas encontram-se as Pequenas Centrais Hidrelétricas (PCHs). Esse tipo de fonte participa do Mercado de Curto Prazo (MCP), que valora as diferenças entre as quantidades contratadas e as efetivamente geradas ao Preço de Liquidação das Diferenças (PLD), considerado neste problema como uma variável aleatória. Para mitigar os riscos envolvidos com a exposição a baixos valores do PLD no MCP o agente pode assinar contratos bilaterais no ACL, comercializar energia por meio de leilões realizados no ACR ou ambos. A impossibilidade do domínio da produção de cada agente de geração devido ao despacho centralizado levou à criação do Mecanismo de Realocação de Energia (MRE). Este mecanismo procura compartilhar entre seus integrantes os riscos hidrológicos, onde as PCHs podem decidir se participam do MRE. Este mecanismo garante que todas as usinas participantes comercializem no mínimo uma geração alocada igual à garantia física sazonalizada no mês. Diante dessa realidade, o foco principal deste trabalho consiste em abordar a otimização de portfólios para a comercialização de energia considerando a participação ou não de um grupo de PCHs no MRE, com o objetivo de maximizar a receita do agente em um horizonte plurianual discretizado mensalmente. Destacam-se nos resultados o benefício na receita no caso em que o agente participa do MRE considerando uma sazonalização estratégica para o caso de estudo apresentado neste trabalho.<br> / Abstract : In the Brazilian Electric Sector (BES), the commercialization of energy is effective through two contracting atmosphere: the Regulated Contracting Atmosphere (RCA) and the Free Contracting Atmosphere (FCA). The generation agents can trade their energy in both the RCA and the FCA through commercialization agents and free consumers, knowing that a small portion called stimulated sourcesare also able to sell to special consumers. Within the stimulated sources, given basically by renewable resources, are found the Small Hydro Units (SHU). This kind of source, which is part of the spot market (SM), values the differences between the
contracted quantities and the effectively generated quantitiesby the spot price, which is considered a random variable. To reduce the risk involving the exposition of the low spot prices in the spot market, the agent can celebrate bilateral contracts in the FCA, conduct auctions in the RCA or both. The impossibility of controlling the production by each generating agent due to the centralized delivery resulted in the creation of the Energy Reallocation Mechanism (ERM). This mechanism seeks to share among its members the hydrological risks where the SHU can decide whether to participate in the ERM or not. This mechanism guarantees that all the plants involved commercialize at least their assigned energy in a given month. Before this reality, the main issue of this dissertation consists of embarking in the optimization
of the portfolios for the commercialization of energy considering the participation or exclusion of a group of SHU in the ERM whose only objective is maximizing the revenue of the agent in a yearly scenariodivided monthly. Stand out in the results that the benefit in revenue is more significant when the agent participates in the ERM considering a strategic seasonality for the case study presented in this dissertation.
|
Page generated in 0.1331 seconds