• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • 2
  • Tagged with
  • 22
  • 22
  • 9
  • 9
  • 7
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Comparação do desempenho energético entre sistema de condicionamento de ar com distribuição pelo piso e pelo teto, utilizando o modelo computacional EnergyPlus. / Comparison of the energy performance between air conditioning system with floor and ceiling distribution, using the EnergyPlus computational model.

Gabriel Adão Borges 19 April 2018 (has links)
Em pauta já há algum tempo, os impactos ambientais, possivelmente gerados pela ação humana, são cada vez mais discutidos e estudados. A busca por um desenvolvimento sustentável e formas mais eficientes do consumo de energia é abordada frequentemente. No Brasil, os edifícios comerciais e públicos apresentam alta demanda de energia elétrica e os sistemas de condicionamento de ar são responsáveis por uma parcela relevante do consumo no país. Para mitigar esse consumo, o sistema de ar condicionado distribuído pelo piso tem sido proposto como uma solução, pois este é intrinsecamente mais eficiente que o sistema de ar condicionado convencional, com distribuição de ar pelo teto. O presente trabalho tem como propósito identificar o potencial de economia de energia de um sistema de condicionamento de ar com distribuição pelo piso em relação a um sistema com distribuição pelo teto, por meio da simulação computacional. Avaliaram-se também o impacto do aumento da temperatura de insuflação e do pé-direito da edificação, além do uso de ciclo economizador (controle entálpico) aplicado aos sistemas na economia de energia. Para a modelagem computacional, realizada pela ferramenta computacional EnergyPlus, tomou-se como referência uma sala de aula que contém um sistema de condicionamento de ar com distribuição pelo piso. O primeiro sistema modelado foi pelo piso, e este serviu como base para a modelagem do sistema pelo teto. Após a criação dos modelos foram executadas as simulações cujos resultados permitiram a comparação entre os consumos de energia de cada um dos sistemas. Em conformidade com a literatura, onde se afirmam que os sistemas com distribuição de ar pelo piso são mais eficientes que os convencionais (distribuição de ar pelo teto), este trabalho também concluiu que este sistema é mais eficiente, apresentando um indicador de economia de energia da ordem de 33%, para a condição: pé-direito de 3,50 m; temperatura de insuflação de 19 °C; e controle entálpico. Os resultados desta pesquisa indicam ainda que a utilização do controle entálpico tem maior influência na economia de energia se comparada ao aumento da temperatura de insuflação ou do pé-direito. / On the agenda for some time, the environmental impacts, possibly generated by human action, are increasingly discussed and studied. The demand for sustainable development and more efficient ways of energy consumption is often addressed. In Brazil, commercial and public buildings have high demand for electricity and air conditioning systems are responsible for a significant portion of this consumption in the country. The underfloor air conditioning system has been proposed as a solution to mitigate such consumption because it is intrinsically more efficient than the ceiling-based air conditioning system. The present work aims to identify the energy saving potential of an air conditioning system with underfloor air distribution comparatively to a system with ceiling air distribution, through computational simulation. Also, the impact of increased supply air temperature and the floor to ceiling height, and the use of the economizer cycle (enthalpy control) was evaluated. For the computational modeling, carried out by the EnergyPlus computational tool, a classroom that contains an air conditioning system with floor distribution was used as reference. The first modeled air distribution system was the underfloor air distribution system, and this served as a basis for the modeling of the ceiling air distribution system. After performing the models, the simulations were carried out, whose results allowed the comparison the energy consumptions between the two systems. According to the literature, where it is stated that the systems with underfloor air distribution are more efficient than the conventional ones (ceiling air distribution), this work also concludes that the system with underfloor air distribution is more efficient, presenting an energy saving indicator around 33%, for the following condition: floor to ceiling height of 3.50 m; supply air temperature of 19 ° C; and enthalpy control. The results of this research also indicate that the use of the enthalpy control has a greater influence on the energy savings compared to the increase of the supply air temperature or the floor to ceiling height.
22

Um novo sistema de refrigeração com controle de temperatura, compressor aberto, máquina de indução trifásica com velocidade variável e correção ativa do fator de potência do estágio de entrada

Leandro, Eduardo [UNESP] 25 September 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:35Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-09-25Bitstream added on 2014-06-13T19:26:47Z : No. of bitstreams: 1 leandro_e_me_ilha.pdf: 1745578 bytes, checksum: 2db70f1465f9f7258fdbcda3cdebf72c (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho apresenta uma nova proposta para sistema de refrigeração com controle dinâmico de temperatura, operando com estrutura de compressor aberto, acionado por motor de indução trifásico com velocidade variável, e estágio de entrada retificador com correção ativa do fator de potência. O estágio de entrada é composto por um retificador Boost monofásico com elevado fator de potência, com duas células entrelaçadas, operando no modo de condução crítica, empregando técnica de comutação não dissipativa e controlado por dispositivo FPGA, associado a um estágio de saída inversor de dois níveis convencional trifásico à IGBT, o qual é controlado por um Processador Digital de Sinais (DSP - Digital Signal Processor). A técnica de comutação não dissipativa para o estágio de entrada é baseada em células ZCS (Zero-current-switching). As principais características do retificador incluem a redução da ondulação da corrente de entrada, redução da ondulação da tensão de saída retificada, utilização de componentes com reduzidos esforços, reduzido volume do filtro de entrada para Interferências Eletromagnéticas (EMI - Electromagnetic Interference), elevado Fator de Potência (FP) e reduzida Distorção Harmônica Total (DHT) da corrente de entrada, atendendo os limites da norma IEC61000-3-2. O controle digital para o estágio de saída inversor foi desenvolvido usando duas diferentes técnicas, incluindo a técnica convencional controle escalar Volts/Hertz (V/Hz) e o controle Vetorial com Orientação pelo Fluxo do estator, com o propósito de verificar a aplicabilidade e a performance dos controles digitais propostos, para o controle contínuo da temperatura, aplicados a um protótipo de sistema de refrigeração. / This work presents a new proposal for refrigeration systems with dynamic control of temperature, working with structure of open compressor, driving a three-phase induction motor with variable speed, and input rectifier with active power factor correction. The proposed system is composed of a single-phase high-power-factor boost rectifier, with two cells in interleaved connection, operating in critical conduction mode, and employing a softswitching technique, controlled by a Field Programmable Gate Array (FPGA), associated with a conventional three-phase IGBT bridge inverter (VSI - Voltage Source Inverter), controlled by a Digital Signal Processor (DSP). The soft-switching technique for the input stage is based on zero-current-switching (ZCS) cells. The rectifier s features include reduction in input current ripple, reduction in output voltage ripple, use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the IEC61000-3-2 standards. The digital controller for the output stage inverter has been developed using two different techniques, the conventional Voltage-Frequency control (scalar V/Hz control), and a simplified stator oriented vector control, in order to verify the feasibility and performance of the proposed digital controls, for continuous temperature control, applied at a refrigerator prototype.

Page generated in 0.0969 seconds