Thermodynamic Analysis And Simulation Of A Solar Thermal Power SystemHarith, Akila 01 1900 (has links) (PDF)
Solar energy is a virtually inexhaustible energy resource, and thus, has great potential in helping meet many of our future energy requirements. Current technology used for solar energy conversion, however, is not cost effective. In addition, solar thermal power systems are also generally less efficient as compared to fossil fuel based thermal power plants. There is a large variety of systems for solar thermal power generation, each with certain advantages and disadvantages. A distinct advantage of solar thermal power generation systems is that they can be easily integrated with a storage system and/or with an auxiliary heating system (as in hybrid power systems) to provide stable and reliable power. Also, as the power block of a solar thermal plant resembles that of a conventional thermal power plant, most of the equipment and technology used is already well defined, and hence does not require major break through research for effective utilisation. Manufacturing of components, too, can be easily indigenized.
A solar collector field is generally used for solar thermal energy conversion. The field converts high grade radiation energy to low grade heat energy, which will inevitably involve energy losses as per the laws of thermodynamics. The 2nd law of thermodynamics requires that a certain amount of heat energy cannot be utilised and has to be rejected as waste heat. This limits the efficiency of solar thermal energy technology. However, in many situations, the waste heat can be effectively utilized to perform refrigeration and desalination using absorption or solid sorption systems, with technologies popularly known as “polygeneration”.
There is extensive research done in the area of solar collectors, including but not limiting to thermal analysis, testing of solar collectors, and economic analysis of solar collectors. Exergy and optimization analyses have also been done for certain solar collector configurations. Research on solar thermal power plants includes energy analysis at system level with certain configurations. Research containing analysis with insolation varying throughout the day is limited. Hence, there is scope for analysis incorporating diurnal variation of insolation for a solar thermal power system.
This thesis centres on the thermodynamic analysis at system level of a solar thermal power system using a concentrating solar collector field and a simple Rankine cycle power generation (with steam as the working fluid) for Indian conditions. The aim is to develop a tool for thermodynamic analysis of solar thermal power systems, with a generalised approach that can also be used with different solar collector types, different heat transfer fluids in the primary loop, and also different working fluids in the secondary loop.
This analysis emphasises the solar collector field and a basic sensible heat storage system, and investigates the various energy and exergy losses present. Comparisons have been made with and without a storage unit and resulting performance issues of solar thermal power plants have been studied. Differences between the system under consideration and commercially used thermal power plants have also been discussed, which brought out certain limitations of the technology currently in use. A solution from an optimization analysis has been utilized and modified for maximization of exergy generated at collector field.
The analysis has been done with models incorporating equations using the laws of thermodynamics. MATLAB has been used to program and simulate the models. Solar radiation data used is from NREL’s Indian Solar Resource Data, which is obtained using their SUNY model by interpreting satellite imagery.
The performance of the system has been analysed for Bangalore for four different days with different daylight durations, each day having certain differences in the incident solar radiation or insolation received. A particular solution of an optimization analysis has been modified using the simulation model developed and analysed with the objective of maximization of exergy generated at collector field.
It has been found that the performance of the solar thermal power system was largely dependent on the variation of incident solar radiation. The storage system provided a stableperformance for short duration interruptions of solar radiation occurred on Autumn Equinox (23-09-2002).The duration of the interruption was within the limits of storage unit capacity. The major disruption in insolation transpired on Summer Solstice (21-06-2002) caused a significantly large drop in the solar thermal system performance; practically the system ceased to function due to lack of energy resource. Hence, the use of an auxiliary heating system hasbeen considered desirable.
The absence of a storage unit has been shown to cause a significant loss in gross performance of the power system. The Rankine cycle turbine had many issues coping with a highly fluctuating energy input, and thus caused efficiency losses and even ceased power generation. A storage unit has been found to be ideal for steady power generation purposes. Some commercial configurations may lack a storage system, but they have been compensated by the auxiliary heating system to ensure stable power generation.
The optimization of the solar collector determines that optimal collector temperatures vary in accordance to the incident solar radiation. Hence, the collector fluid outlet temperature must not be fixed so as to handle varying insolation for optimal exergy extraction. The optimal temperatures determined for Bangalore are around 576 K which is close to the values obtained by the simulation of the solar thermal power system.
The tools for analysis and simulation of solar thermal power plants developed in this thesis is fairly generalised, as it can be adapted for various types of solar collectors and for different working fluids (other than steam), such as for Organic Rankine Cycle (ORC). The model can also be easily extended to other types of power cycles such as Brayton and Stirling cycles.
|
2 |
Thermodynamics of Distributed Solar Thermal Power Systems with StorageGarg, Pardeep January 2015 (has links) (PDF)
Distributed power generation through renewable sources of energy has the potential of meeting the challenge of providing electricity access to the off-grid population, estimated to be around 1.2 billion residing across the globe with 300 million in India, in a sustainable way. Technological solutions developed around these energy challenges often involve thermal systems that convert heat available from sources like solar, biomass, geothermal or unused industrial processes into electricity. Conventional steam based thermodynamic cycle at distributed scale (< 1 MWe) suffers from low efficiency driving scientific research to develop new, scalable, efficient and economically viable power cycles. This PhD work conducts one such study which provides a database of thermal power blocks optimized for the lowest initial investment cost to developers of distributed power plants. The work is divided in two steps; a) feasibility study of various thermodynamic cycles for distributed power generation covering different operating temperature regimes and b) perform their detailed thermo-economic modelling for the heat sources mentioned above.
Thermodynamic cycles are classified into three temperature domains namely, low (< 450 K), medium (< 600 K) and high (< 1000 K) T cycles. Any fluid whose triple point temperature is below the typical ambient temperatures is a potential working fluid in the power cycle. Most of the organic and the inorganic fluids satisfy this criterion and can be perceived as potential power cycle fluids. The general notion is that organic fluids are more suited for low or medium temperature cycles whereas inorganic fluids for high temperature ones. Organic fluids can further be classified into hydrofluorocarbon and hydrocarbon. While the former has high global warming potential (GWP), the latter is flammable in nature. Their mixture in certain compositions is found to obviate both the demerits and perform equally well on thermodynamic scales for low T cycles. On the similar lines, mixture of HCs and inorganic fluids, such as propane+CO2 and isopentane+CO2 are found to be more appropriate for medium T applications if the issues like pinch temperature in the regenerator arising due to temperature glide are taken care of.
In the high temperature domain, high efficiency Brayton cycle (supercritical CO2) and transcritical condensing cycles are studied with the latter being 2 % more efficient than the former. However, application of the condensing cycle is limited to low temperature ambient locations owing to low critical temperature of CO2 (304 K). In the same cycle configuration,
mixture of CO2 and propane (52 and 48%) with a critical temperature of ~ 320 K is observed to retain the thermodynamic performance with the increased heat rejection temperature matched to the tropical ambient conditions. However, these cycles are plagued by the high operating pressures (~300 bar) calling for high temperature steel making the power block uneconomical. In this regard, the advanced CO2 cycles are developed wherein the optimum operating pressures are limited to 150 bar with an increased cycle efficiency of 6 % over the S-CO2 cycle. Feasibility study carried out on these cycles in the Indian context indicates the low and medium T cycles to be better suited for distributed power generation over the high T cycles.
In the second part of work, a comprehensive study is performed to optimize the low and the medium T cycles on a thermo-economic basis for the minimum specific investment cost ($/We). Such a study involves development of component level models which are then integrated to form the system of interest, thus, following a bottom-up approach. A major emphasis is given on the development of scroll expander and low cost pebble bed thermal energy storage system that are the reported in the literature as the areas with high uncertainties while connecting them to the system. Subsequently, the key design parameters influencing the specific cost of power from an air-cooled ORC are identified and used to formulate a 7-dimensional space to search for the minimum costs for applications with a) geothermal/waste or biogas heat sources and b) solar ORCs. Corresponding maps of operating parameters are generated to facilitate distributed power engineers in the design of economic systems within constraints such as available heat source temperatures, maximum expander inlet pressures imposed, etc. Further, the effect of power scaling on these specific costs is evaluated for ORC capacities between 5 and 500 kWe.
|