41

Estudo da resistência ao cisalhamento e da condutividade hidráulica de solos coluvionares não saturados da Formação Serra Geral / Shear strength and hydraulic conductivity of unsaturated colluvium soils from Serra Geral Formation

Feverharmel, Carolina January 2007 (has links)
Esta tese apresenta um estudo sobre a resistência ao cisalhamento e a condutividade hidráulica de dois solos coluvionares não saturados situados na divisa dos estados do Rio Grande do Sul e Santa Catarina, em um dos trechos do Gasoduto Bolívia-Brasil. Esses solos são constituídos por sedimentos oriundos da Formação Serra Geral (basalto – Solo RO) e da Formação Botucatu (arenito – Solo AV). O trabalho de pesquisa realizado com esses solos tem seu enfoque dividido em duas partes principais: (1) obtenção direta da resistência ao cisalhamento e da função condutividade hidráulica em diferentes níveis de sucção, e (2) previsão indireta dessas propriedades a partir da determinação da curva característica do solo e de parâmetros geotécnicos saturados. As curvas características dos solos AV e RO, nas condições indeformada e remoldada (sem e com secagem prévia do solo), foram obtidas pelo uso combinado do método do papel filtro e da placa de sucção. Para as condições indeformada e remoldada sem secagem prévia, essas curvas exibiram um formato bimodal. A dessaturação é controlada pelos macroporos, para baixas sucções, e pelos microporos, para altas sucções. Para valores de sucção intermediários, praticamente não ocorre remoção de água do solo, devido, provavelmente, à ausência de poros com tamanho intermediário. Já as curvas características das amostras remoldadas com secagem prévia do solo tendem a apresentar um formato mais próximo do unimodal. A influência do índice de vazios inicial e da história de umedecimento e secagem no formato da curva é também discutida. A resistência ao cisalhamento dos solos estudados foi determinada em laboratório através de ensaios de cisalhamento direto convencionais e com sucção controlada. Os resultados, obtidos para amostras indeformadas e remoldadas sem secagem prévia, permitiram a determinação dos parâmetros de resistência ao cisalhamento c’, f’ e fb. Para determinação direta da função condutividade hidráulica do Solo AV foi construído um permeâmetro triaxial com controle de sucção, baseado no modelo apresentado por Huang et al. (1998). Esse equipamento foi utilizado para determinação da função condutividade hidráulica do Solo AV não saturado, em diferentes trajetórias de umedecimento e secagem. Os resultados evidenciaram que as amostras do Solo AV nas três condições de moldagem - indeformada, remoldada sem e com secagem - tendem a reproduzir o comportamento de dessaturação exibido nas curvas características. A função condutividade hidráulica apresenta inicialmente um decréscimo para sucções até 50 kPa, seguido por um valor praticamente constante, para sucções até 90 kPa. / This thesis presents a study about the shear strength and hydraulic conductivity of two unsaturated colluvium soils situated at the border between the states of Rio Grande do Sul and Santa Catarina, along one of the Bolivia-Brazil Gas Pipeline stretches. These soils are constituted by sediments originated from Serra Geral (basalt – sample RO) and Botucatu formations (sandstone - sample AV). The research performed with these soils had its focus divided in two main parts: (1) direct measurements of shear strength and hydraulic conductivity function at different suction levels and (2) indirect prediction of these properties from the soil-water characteristic curves and saturated geotechnical parameters. The soilwater characteristic curves of AV and RO Samples, in undisturbed and remolded conditions (without and with previous drying), were determined with both the filter-paper technique and the suction-plate technique. The undisturbed and remolded samples without previous drying showed a bimodal shape. The desaturation is controlled by the macropores for low suction values and by the micropores, for higher values. For intermediary suctions values, practically no removal of water from the sample occurs, possibly due to the lack of intermediate pore sizes. The remolded samples with previous drying tend to present a shape close to unimodal. The influences of void ratio and the drying and wetting history in the shape of the soil-water characteristic curve are also discussed. The shear strength of the studied soils was determined with conventional and suction-controlled direct shear tests. The results obtained for undisturbed and remolded samples without previous drying allowed the determination of shear strength parameters c’, f’ e fb. For the direct measurement of hydraulic conductivity function, a flexible-wall permeameter was built, based on the model presented by Huang et al. (1998). This equipment was used for determining the unsaturated hydraulic conductivity function of Sample AV in different drying and wetting paths. The results showed that Samples AV in the three molding conditions - undisturbed and remolded without and with previous drying – reproduced the desaturation behavior showed by the soil-water characteristic curves. The hydraulic conductivity function presents initially a decrease for suctions up to 50 kPa, followed by a practically constant value, for suctions up to 90 kPa.
42

Camada de cobertura de aterro de resíduos sólidos: estudo preliminar de casos / Solid waste landfill cover layer: preliminary study of cases.

Isabela Maria Barroso 18 March 2008 (has links)
Apresenta uma revisão sobre os conceitos teóricos de solos não saturados e sobre camadas de cobertura de Aterro. Ressalta a tecnologia de utilização de camadas evapotranspirativas e apresenta os tipos existentes desta camada. / It is a review about the non saturated soils concepts and waste landfill cover system. It points out the technology of using evaptranspirative cover systems and presents the existing kinds of this covers.
43

Estudo da resistência ao cisalhamento e da condutividade hidráulica de solos coluvionares não saturados da Formação Serra Geral / Shear strength and hydraulic conductivity of unsaturated colluvium soils from Serra Geral Formation

Feverharmel, Carolina January 2007 (has links)
Esta tese apresenta um estudo sobre a resistência ao cisalhamento e a condutividade hidráulica de dois solos coluvionares não saturados situados na divisa dos estados do Rio Grande do Sul e Santa Catarina, em um dos trechos do Gasoduto Bolívia-Brasil. Esses solos são constituídos por sedimentos oriundos da Formação Serra Geral (basalto – Solo RO) e da Formação Botucatu (arenito – Solo AV). O trabalho de pesquisa realizado com esses solos tem seu enfoque dividido em duas partes principais: (1) obtenção direta da resistência ao cisalhamento e da função condutividade hidráulica em diferentes níveis de sucção, e (2) previsão indireta dessas propriedades a partir da determinação da curva característica do solo e de parâmetros geotécnicos saturados. As curvas características dos solos AV e RO, nas condições indeformada e remoldada (sem e com secagem prévia do solo), foram obtidas pelo uso combinado do método do papel filtro e da placa de sucção. Para as condições indeformada e remoldada sem secagem prévia, essas curvas exibiram um formato bimodal. A dessaturação é controlada pelos macroporos, para baixas sucções, e pelos microporos, para altas sucções. Para valores de sucção intermediários, praticamente não ocorre remoção de água do solo, devido, provavelmente, à ausência de poros com tamanho intermediário. Já as curvas características das amostras remoldadas com secagem prévia do solo tendem a apresentar um formato mais próximo do unimodal. A influência do índice de vazios inicial e da história de umedecimento e secagem no formato da curva é também discutida. A resistência ao cisalhamento dos solos estudados foi determinada em laboratório através de ensaios de cisalhamento direto convencionais e com sucção controlada. Os resultados, obtidos para amostras indeformadas e remoldadas sem secagem prévia, permitiram a determinação dos parâmetros de resistência ao cisalhamento c’, f’ e fb. Para determinação direta da função condutividade hidráulica do Solo AV foi construído um permeâmetro triaxial com controle de sucção, baseado no modelo apresentado por Huang et al. (1998). Esse equipamento foi utilizado para determinação da função condutividade hidráulica do Solo AV não saturado, em diferentes trajetórias de umedecimento e secagem. Os resultados evidenciaram que as amostras do Solo AV nas três condições de moldagem - indeformada, remoldada sem e com secagem - tendem a reproduzir o comportamento de dessaturação exibido nas curvas características. A função condutividade hidráulica apresenta inicialmente um decréscimo para sucções até 50 kPa, seguido por um valor praticamente constante, para sucções até 90 kPa. / This thesis presents a study about the shear strength and hydraulic conductivity of two unsaturated colluvium soils situated at the border between the states of Rio Grande do Sul and Santa Catarina, along one of the Bolivia-Brazil Gas Pipeline stretches. These soils are constituted by sediments originated from Serra Geral (basalt – sample RO) and Botucatu formations (sandstone - sample AV). The research performed with these soils had its focus divided in two main parts: (1) direct measurements of shear strength and hydraulic conductivity function at different suction levels and (2) indirect prediction of these properties from the soil-water characteristic curves and saturated geotechnical parameters. The soilwater characteristic curves of AV and RO Samples, in undisturbed and remolded conditions (without and with previous drying), were determined with both the filter-paper technique and the suction-plate technique. The undisturbed and remolded samples without previous drying showed a bimodal shape. The desaturation is controlled by the macropores for low suction values and by the micropores, for higher values. For intermediary suctions values, practically no removal of water from the sample occurs, possibly due to the lack of intermediate pore sizes. The remolded samples with previous drying tend to present a shape close to unimodal. The influences of void ratio and the drying and wetting history in the shape of the soil-water characteristic curve are also discussed. The shear strength of the studied soils was determined with conventional and suction-controlled direct shear tests. The results obtained for undisturbed and remolded samples without previous drying allowed the determination of shear strength parameters c’, f’ e fb. For the direct measurement of hydraulic conductivity function, a flexible-wall permeameter was built, based on the model presented by Huang et al. (1998). This equipment was used for determining the unsaturated hydraulic conductivity function of Sample AV in different drying and wetting paths. The results showed that Samples AV in the three molding conditions - undisturbed and remolded without and with previous drying – reproduced the desaturation behavior showed by the soil-water characteristic curves. The hydraulic conductivity function presents initially a decrease for suctions up to 50 kPa, followed by a practically constant value, for suctions up to 90 kPa.
44

Resistência ao cisalhamento de solos não saturados : análise experimental e teórica / Shear strength of unsaturated soils : experimental and theoretical analysis

Pereira, Álvaro January 2006 (has links)
Um equipamento triaxial convencional originalmente utilizado para ensaios em amostras de solos saturados saturada foi modificado para que fosse possível a realização de ensaios triaxiais em solos não saturados. As principais modificações foram a instalação de uma pedra cerâmica de alto valor de entrada de ar (300 kPa) na nova base da câmara triaxial e uma nova linha de aplicação de pressão para aplicação de pressão de ar na amostra. A técnica de translação de eixos é utilizada para evitar cavitação no sistema de aplicação de pressão. O solo estudado nesta pesquisa consiste de um colúvio de arenito localizado nas encostas da Formação Serra Geral, entre os municípios de Timbé do Sul (SC) e São José dos Ausentes (RS). Ensaios triaxiais convencionais foram realizados nas condições drenado e não drenado em amostras indeformadas para tensões de confinamento iniciais variando de 50 até 500 kPa; ensaios triaxiais convencionais foram realizados na condição drenada em amostras remoldadas para as tensões de confinamento iniciais de 50, 100 e 200kPa. Ensaios triaxiais com sucção controlada foram realizados na condição drenado em amostras indeformadas para as tensões normais líquidas de 50, 100, 150 e 200 kPa em níveis de sucção variando de 25 até 150 kPa. A partir dos resultados dos ensaios triaxiais determinou-se os parâmetros de resistência ao cisalhamento: c’ – intercepto coesivo efetivo; f´ - ângulo de atrito interno efetivo; fb – ângulo de atrito interno que quantifica a contribuição da sucção na resistência ao cisalhamento. O comportamento encontrado foi de uma envoltória de resistência ao cisalhamento não saturada bilinear com acréscimo na resistência ao cisalhamento para baixos níveis de sucção até aproximadamente 75 kPa, e após um decréscimo na resistência ao cisalhamento. A tensão normal líquida não influencia no valor de fb e a sucção não provoca alteração no valor de f´. O valor de fb apresenta valores superiores ao valor de f´, quando se utiliza o critério de ruptura clássico de resistência ao cisalhamento. Alguns critérios de determinação dos valores máximos de ruptura foram aplicados para um melhor entendimento do comportamento resistente deste material. / A conventional triaxial equipment, originally used for testing saturated soil specimens, was modified in order to allow the testing of unsaturated specimens. The main modifications consisted of the installation of a high air-entry value porous ceramic (300 kPa) in the modified cell base and a new drainage line for application of pore-air pressure to the specimens. The axis-translation technique is used to prevent cavitation in the pressure measuring system. The soil studied consists of a colluvium of sandstone located on hillsides of the Serra Geral Formation, in the municipal districts of Timbé do Sul (SC) and São José dos Ausentes (RS). Saturated triaxial tests were carried out under drained and undrained conditions for undisturbed specimens for initial effective stresses of 50 to 500 kPa; saturated triaxial tests were carried out under drained conditions for remolded specimens for initial effective stresses of 50, 100 and 200 kPa. Unsaturated triaxial tests were carried out under drained conditions for undisturbed specimens for net normal stresses of 50, 100, 150 and 200 kPa with suction levels varying from 25 to 150 kPa. Shear strength parameters were determined from the results of those triaxial tests: c' – effective cohesion intercept; f´ - angle of internal friction; fb - angle of internal friction that indicates the rate of change in shear strength due to changes in matric suction. The observed behavior was of a bi-linear unsaturated shear strength envelope with increments of shear strength at low suctions until a value of suction equal to 75 kPa was reached; above this value a loss of shear strength was observed. The net normal stress has negligible influence on the fb value and suction does not cause changes in the f´ value. The fb value is higher than f´ value when the classic shear strength criterion is used. Other criteria for the determination of failure values were used for a better understanding of the shear strength behavior of the soil studied.
45

Camada de cobertura de aterro de resíduos sólidos: estudo preliminar de casos / Solid waste landfill cover layer: preliminary study of cases.

Isabela Maria Barroso 18 March 2008 (has links)
Apresenta uma revisão sobre os conceitos teóricos de solos não saturados e sobre camadas de cobertura de Aterro. Ressalta a tecnologia de utilização de camadas evapotranspirativas e apresenta os tipos existentes desta camada. / It is a review about the non saturated soils concepts and waste landfill cover system. It points out the technology of using evaptranspirative cover systems and presents the existing kinds of this covers.
46

Análise de ruptura de talude em solo não saturado / Slope back analysis in unsatured soils

José Antonio Cancino Calle 30 June 2000 (has links)
Apresenta-se neste trabalho uma análise de ruptura de um talude em solo não saturado. O talude, com cerca de 15 m de altura, é composto de areia fina a média argilosa, com grau de saturação da ordem de 55% e SPT variando entre 4 golpes no topo a 13 golpes na base. Determinaram-se as seguintes propriedades do solo: resistência, condutividade hidráulica saturada e não saturada e curva de retenção, além de medir-se a sucção matricial em campo ao longo do ano. Efetuaram-se análises paramétricas para avaliar o efeito da precipitação na mudança do perfil de sucção matricial do terreno e suas implicações na resistência e, por extensão, na estabilidade do talude. Construíram-se, também, ábacos que incluem o efeito da variação da sucção matricial, utilizáveis para taludes com características semelhantes ao talude estudado. Verificou-se que para as condições do talude natural, no auge da estação seca, as sucções matriciais são de tal magnitude que fornecem estabilidade ao talude. À medida que ocorrem precipitações, as sucções matriciais reduzem-se e o fator de segurança do talude diminui, o que justifica a ruptura ocorrida. / In this article is showing an slope back analysis in unsaturated soil. The slope, with about 15 m of height, it is composed of a fine to medium clayey sand, with degree of saturation of the order of 55% and SPT varying among 4 blows in the top to 13 blows in the base. The following properties of the soil were determined: resistance, saturated and unsaturated conductivity and it curves of retention, besides measuring the suction along the year. Parametric analyses were made to evaluate the effect of the precipitation in the changes of the ground matricial suction profile and its implications in the resistance and, by extension, in the slope stability. They were also made, some abaci that include the effect of the matricial suction variation, usable for slopes with similar characteristics to the studied slope. It was verified that for the conditions of the natural slope, next to the peak of the dry station, the matricial suction is of such magnitude that it supply stability to the slope. In the successive events of precipitations the matricials suctions is reduced and the slope security factor decreases, that justifies the happened rupture.
47

Resistência ao cisalhamento de solos não saturados : análise experimental e teórica / Shear strength of unsaturated soils : experimental and theoretical analysis

Pereira, Álvaro January 2006 (has links)
Um equipamento triaxial convencional originalmente utilizado para ensaios em amostras de solos saturados saturada foi modificado para que fosse possível a realização de ensaios triaxiais em solos não saturados. As principais modificações foram a instalação de uma pedra cerâmica de alto valor de entrada de ar (300 kPa) na nova base da câmara triaxial e uma nova linha de aplicação de pressão para aplicação de pressão de ar na amostra. A técnica de translação de eixos é utilizada para evitar cavitação no sistema de aplicação de pressão. O solo estudado nesta pesquisa consiste de um colúvio de arenito localizado nas encostas da Formação Serra Geral, entre os municípios de Timbé do Sul (SC) e São José dos Ausentes (RS). Ensaios triaxiais convencionais foram realizados nas condições drenado e não drenado em amostras indeformadas para tensões de confinamento iniciais variando de 50 até 500 kPa; ensaios triaxiais convencionais foram realizados na condição drenada em amostras remoldadas para as tensões de confinamento iniciais de 50, 100 e 200kPa. Ensaios triaxiais com sucção controlada foram realizados na condição drenado em amostras indeformadas para as tensões normais líquidas de 50, 100, 150 e 200 kPa em níveis de sucção variando de 25 até 150 kPa. A partir dos resultados dos ensaios triaxiais determinou-se os parâmetros de resistência ao cisalhamento: c’ – intercepto coesivo efetivo; f´ - ângulo de atrito interno efetivo; fb – ângulo de atrito interno que quantifica a contribuição da sucção na resistência ao cisalhamento. O comportamento encontrado foi de uma envoltória de resistência ao cisalhamento não saturada bilinear com acréscimo na resistência ao cisalhamento para baixos níveis de sucção até aproximadamente 75 kPa, e após um decréscimo na resistência ao cisalhamento. A tensão normal líquida não influencia no valor de fb e a sucção não provoca alteração no valor de f´. O valor de fb apresenta valores superiores ao valor de f´, quando se utiliza o critério de ruptura clássico de resistência ao cisalhamento. Alguns critérios de determinação dos valores máximos de ruptura foram aplicados para um melhor entendimento do comportamento resistente deste material. / A conventional triaxial equipment, originally used for testing saturated soil specimens, was modified in order to allow the testing of unsaturated specimens. The main modifications consisted of the installation of a high air-entry value porous ceramic (300 kPa) in the modified cell base and a new drainage line for application of pore-air pressure to the specimens. The axis-translation technique is used to prevent cavitation in the pressure measuring system. The soil studied consists of a colluvium of sandstone located on hillsides of the Serra Geral Formation, in the municipal districts of Timbé do Sul (SC) and São José dos Ausentes (RS). Saturated triaxial tests were carried out under drained and undrained conditions for undisturbed specimens for initial effective stresses of 50 to 500 kPa; saturated triaxial tests were carried out under drained conditions for remolded specimens for initial effective stresses of 50, 100 and 200 kPa. Unsaturated triaxial tests were carried out under drained conditions for undisturbed specimens for net normal stresses of 50, 100, 150 and 200 kPa with suction levels varying from 25 to 150 kPa. Shear strength parameters were determined from the results of those triaxial tests: c' – effective cohesion intercept; f´ - angle of internal friction; fb - angle of internal friction that indicates the rate of change in shear strength due to changes in matric suction. The observed behavior was of a bi-linear unsaturated shear strength envelope with increments of shear strength at low suctions until a value of suction equal to 75 kPa was reached; above this value a loss of shear strength was observed. The net normal stress has negligible influence on the fb value and suction does not cause changes in the f´ value. The fb value is higher than f´ value when the classic shear strength criterion is used. Other criteria for the determination of failure values were used for a better understanding of the shear strength behavior of the soil studied.
48

Estudo da resistência ao cisalhamento e da condutividade hidráulica de solos coluvionares não saturados da Formação Serra Geral / Shear strength and hydraulic conductivity of unsaturated colluvium soils from Serra Geral Formation

Feverharmel, Carolina January 2007 (has links)
Esta tese apresenta um estudo sobre a resistência ao cisalhamento e a condutividade hidráulica de dois solos coluvionares não saturados situados na divisa dos estados do Rio Grande do Sul e Santa Catarina, em um dos trechos do Gasoduto Bolívia-Brasil. Esses solos são constituídos por sedimentos oriundos da Formação Serra Geral (basalto – Solo RO) e da Formação Botucatu (arenito – Solo AV). O trabalho de pesquisa realizado com esses solos tem seu enfoque dividido em duas partes principais: (1) obtenção direta da resistência ao cisalhamento e da função condutividade hidráulica em diferentes níveis de sucção, e (2) previsão indireta dessas propriedades a partir da determinação da curva característica do solo e de parâmetros geotécnicos saturados. As curvas características dos solos AV e RO, nas condições indeformada e remoldada (sem e com secagem prévia do solo), foram obtidas pelo uso combinado do método do papel filtro e da placa de sucção. Para as condições indeformada e remoldada sem secagem prévia, essas curvas exibiram um formato bimodal. A dessaturação é controlada pelos macroporos, para baixas sucções, e pelos microporos, para altas sucções. Para valores de sucção intermediários, praticamente não ocorre remoção de água do solo, devido, provavelmente, à ausência de poros com tamanho intermediário. Já as curvas características das amostras remoldadas com secagem prévia do solo tendem a apresentar um formato mais próximo do unimodal. A influência do índice de vazios inicial e da história de umedecimento e secagem no formato da curva é também discutida. A resistência ao cisalhamento dos solos estudados foi determinada em laboratório através de ensaios de cisalhamento direto convencionais e com sucção controlada. Os resultados, obtidos para amostras indeformadas e remoldadas sem secagem prévia, permitiram a determinação dos parâmetros de resistência ao cisalhamento c’, f’ e fb. Para determinação direta da função condutividade hidráulica do Solo AV foi construído um permeâmetro triaxial com controle de sucção, baseado no modelo apresentado por Huang et al. (1998). Esse equipamento foi utilizado para determinação da função condutividade hidráulica do Solo AV não saturado, em diferentes trajetórias de umedecimento e secagem. Os resultados evidenciaram que as amostras do Solo AV nas três condições de moldagem - indeformada, remoldada sem e com secagem - tendem a reproduzir o comportamento de dessaturação exibido nas curvas características. A função condutividade hidráulica apresenta inicialmente um decréscimo para sucções até 50 kPa, seguido por um valor praticamente constante, para sucções até 90 kPa. / This thesis presents a study about the shear strength and hydraulic conductivity of two unsaturated colluvium soils situated at the border between the states of Rio Grande do Sul and Santa Catarina, along one of the Bolivia-Brazil Gas Pipeline stretches. These soils are constituted by sediments originated from Serra Geral (basalt – sample RO) and Botucatu formations (sandstone - sample AV). The research performed with these soils had its focus divided in two main parts: (1) direct measurements of shear strength and hydraulic conductivity function at different suction levels and (2) indirect prediction of these properties from the soil-water characteristic curves and saturated geotechnical parameters. The soilwater characteristic curves of AV and RO Samples, in undisturbed and remolded conditions (without and with previous drying), were determined with both the filter-paper technique and the suction-plate technique. The undisturbed and remolded samples without previous drying showed a bimodal shape. The desaturation is controlled by the macropores for low suction values and by the micropores, for higher values. For intermediary suctions values, practically no removal of water from the sample occurs, possibly due to the lack of intermediate pore sizes. The remolded samples with previous drying tend to present a shape close to unimodal. The influences of void ratio and the drying and wetting history in the shape of the soil-water characteristic curve are also discussed. The shear strength of the studied soils was determined with conventional and suction-controlled direct shear tests. The results obtained for undisturbed and remolded samples without previous drying allowed the determination of shear strength parameters c’, f’ e fb. For the direct measurement of hydraulic conductivity function, a flexible-wall permeameter was built, based on the model presented by Huang et al. (1998). This equipment was used for determining the unsaturated hydraulic conductivity function of Sample AV in different drying and wetting paths. The results showed that Samples AV in the three molding conditions - undisturbed and remolded without and with previous drying – reproduced the desaturation behavior showed by the soil-water characteristic curves. The hydraulic conductivity function presents initially a decrease for suctions up to 50 kPa, followed by a practically constant value, for suctions up to 90 kPa.
49

Análise paramétrica da infiltração e sua influência na estabilidade de taludes em solo não saturado / Parametric analysis of infiltration and its influence on unsaturated soil slope stability

Cláudio Rodrigues dos Santos 24 March 2004 (has links)
Apresenta-se um estudo paramétrico acerca da infiltração de água e sua repercussão no Fator de Segurança de talude em solos não saturados. Na análise adota-se um talude de referência com geometria fixada conforme a inclinação típica para taludes em areia argilo siltosa, característica do Centro-Oeste do estado de São Paulo. A análise paramétrica foi desenvolvida a partir de uma simulação de fluxo em regime transiente utilizando o programa SEEP/W, que utiliza o método de elementos finitos, e posteriormente uma análise de estabilidade do talude de referência utilizando o método de Bishop simplificado conforme apresentado no programa SLOPE/W. Foram analisados taludes homogêneos compostos por três diferentes tipos de solo, uma areia, um silte argiloso e uma areia argilo siltosa. Os parâmetros analisados compreendem a curva de retenção de água, a função condutividade hidráulica do solo e a intensidade de precipitação. Verificou-se que a função condutividade hidráulica e a pressão de entrada de ar são os principais determinantes do comportamento da infiltração e conseqüentemente da estabilidade do talude. As simulações de fluxo evidenciaram que os taludes em solos mais arenosos apresentam taxas de infiltração maiores que as apresentadas pelos taludes compostos por solos siltosos. Consequentemente, os escorregamentos ocasionados pela perda da contribuição da sucção para a resistência ao cisalhamento ocorrem primeiramente nos taludes compostos por solos arenosos e posteriormente naqueles compostos por solos siltosos, fato este que pôde ser confirmado pelas análises de estabilidade do talude de referência. / A parametric study is presented about water infiltration and its repercussion in the safety factor of unsaturated soil slopes. In the analysis it is adopted a reference slope with determined geometry according to the typical inclination for slopes in silty clayey sand, characteristic of the mid-western region of São Paulo State, in Brazil. The parametric analysis was developed from a flux simulation in transient regime using the SEEP/W software, which uses the finite elements method, and thereafter, a stability analysis of the reference slope using simplified Bishop method, as presented in the SLOPE/W software. Homogeneous slopes composed by three different types of soil (sand, clayey silt and silty clayey sand) were considered. The analyzed parameters include the water retention curve, the hydraulic conductivity function and the precipitation intensity. It was verified that the hydraulic conductivity function and the air entry value are the main determinants of the infiltration behavior and, subsequently, of the slope stability. The flux simulations have evidenced that coarser soils slopes show higher infiltration rates than the ones presented in finer soil slopes. Consequently, the slides caused by the loss of the suction\'s contribution to shear strength occur primarily in coarser soil slopes than in fine soil slopes, what could be verified in the stability analysis of the reference slope.
50

Avaliação da influência das condições geotécnicas e climáticas no comportamento hidromecânico de um subleito ferroviário. / Evaluation of the influence of geotechnical and climatic conditions on a subgrade hydro-mechanical behavior.

Castro, Guilherme Barbosa de 26 March 2019 (has links)
A subestrutura ferroviária é uma parte importante da via permanente, pois seu comportamento pode afetar significativamente o desempenho global da via, impactando em manutenção e custos. O fato é que os materiais da subestrutura, como o subleito, estão no estado não-saturado na maior parte do tempo, e suas propriedades hidromecânicas dependem diretamente do grau de saturação e dos valores de sucção. Além disso, o estado não-saturado do solo é regido pelas ações atmosféricas e climáticas, o que torna fundamental a análise da influência de características ambientais e geotécnicas, tais como a precipitação, evaporação, tipo de solo e drenagem na resposta estrutural do subleito. Países de clima tropical/subtropical, como o Brasil, possuem elevada taxa de precipitação anual, e, por isso, merecem atenção especial quando se trata da interação via-clima. Mudanças da umidade ou sucção ou da taxa de infiltração no interior do subleito podem impactar significativamente no seu estado de tensões. O principal objetivo desta pesquisa foi avaliar a influência da variação da umidade e sucção no comportamento hidromecânico de um subleito ferroviário, localizado na região costeira do estado de São Paulo, considerando-se as características geotécnicas e climáticas locais. A interação via-clima foi investigada através de análises numéricas em elementos finitos (MEF) de infiltração saturada/não-saturada, aplicando-se parâmetros determinados em laboratório e monitoramento de campo. Para as simulações numéricas foi utilizado o software SEEP/W, enquanto no monitoramento de campo foram empregados sensores de matriz granular para medição do potencial matricial no solo. A caracterização mecânica do solo de subleito se baseou em resultados de módulo de resiliência obtidos por ensaios triaxiais cíclicos, em diferentes condições e ciclos de umidade e sucção. As simulações numéricas apresentaram importantes variações da sucção no solo em função das condições geotécnicas e climáticas, verificando-se a significância dos aspectos climáticos no comportamento hidráulico e mecânico do subleito da via férrea. / The track substructure is an important part of a railway that requires attention when considering its whole global mechanical performance. Improving the long-term resistance to deformation behavior and therefore reducing maintenance problems during the operation of a track is always presented between engineers and researchers. The fact is that the substructure materials, such as the subgrade, are mostly in unsaturated state, and their hydro-mechanical properties are directly dependent on saturation degree and suction values. Besides, unsaturated state of the soil is controlled by atmospheric actions and climate conditions. Considering this, it is fundamental to analyze the influence of the environmental and geotechnical characteristics such as precipitation, evaporation, soil type, and drainage in the subgrade structural response. Countries with tropical/subtropical climate, such as Brazil, which have a high average annual precipitation rate, deserve special attention concerning climate-track interaction in railway performance. A little variation in the water content or infiltration rate into the subgrade may affects significantly their stress state. The main objective of this paper is to evaluate the influence of the water content and suction changes on mechanical behavior of a track substructure in a Brazilian coastal region, at São Paulo state, considering geotechnical characteristics and local climate. The climate-track interaction was evaluated through field monitoring and finite element numerical analysis with parameters obtained in the laboratory for all the materials involved. Numerical simulations were performed using SEEP/W software and the field monitoring was realized through granular matrix sensors (GMS). Soil mechanical characterization was based on resilient modulus values determined through cyclic triaxial tests in different moisture/suction conditions. Numerical results showed an important variation of soil suction over time in function of geotechnical and climate data. In the simulated scenario, considering tropical local climate it was observed the importance of climate aspects in the hydraulic and mechanical behavior of the geotechnical components of the railway track.