• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo do comportamento mecânico de solos reforçados com fibras de Polietileno Tereftalato (PET) de distribuição aleatória / Study of the Mechanical Behavior of Reinforced Soils with Polyethylene Terephthalate (PET) Fibers of Random Distribution

Lucarelli, Daniely Camargos 19 November 2018 (has links)
Submitted by MARCOS LEANDRO TEIXEIRA DE OLIVEIRA (marcosteixeira@ufv.br) on 2019-02-25T11:34:00Z No. of bitstreams: 1 texto completo.pdf: 2651353 bytes, checksum: 3076c1e07b62b81eea065654014f8d6d (MD5) / Made available in DSpace on 2019-02-25T11:34:00Z (GMT). No. of bitstreams: 1 texto completo.pdf: 2651353 bytes, checksum: 3076c1e07b62b81eea065654014f8d6d (MD5) Previous issue date: 2018-11-19 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O presente trabalho teve como objetivo o estudo do comportamento mecânico de solos residuais tropicais reforçados com Fibras PET, os quais foram amostrados no município de Viçosa, Minas Gerais. Para tanto, foi necessário o estudo de diferentes métodos, com a execução de ensaios de Caracterização, Compactação, Índice de Suporte Califórnia (ISC) e Cisalhamento Direto. Para caracterização das amostras dos solos, em um primeiro caso, foram aplicados três métodos classificatórios existentes (MCT, TRB e USCS), e, através dos resultados obtidos, foram evidenciadas as diferenças entre estes, qualificando ou não as amostras para uso em pavimentação. Os ensaios de análise microestrutural possibilitaram analisar as possíveis relações entre a composição química e o comportamento de engenharia dos solos. Também, por meio da adição de fibras PET de garrafas de refrigerante, em diferentes teores, larguras e texturas, foram investigados vários parâmetros de comportamento de engenharia dos solos. Constatou-se, através das análises dos resultados dos ensaios ISC, que, para reforço de subleito, seria possível o emprego das misturas solos-fibras ensaiadas conforme as exigências técnicas do DNIT. Considerando ainda a influência da adição de fibras na resistência ao cisalhamento, verificou-se, em geral, uma melhoria das propriedades mecânicas dos solos-fibras, evidenciando ser promissor o uso destes em obras geotécnicas. Por fim, através da análise do comportamento geotécnico de solo- cimento reforçado com fibras e aditivos, verificou-se melhorias na resistência ao cisalhamento com a adição de fibras, tanto para a parcela correspondente à coesão, quanto àquela correspondente ao atrito interno do material, em comparação aos compósitos de solo-cimento e solo-cimento-aditivos. Além disso, observou-se pouca eficiência dos aditivos no processo de estabilização dos solos, no que diz respeito aos parâmetros de resistência ao cisalhamento. / The current work has aimed to study the mechanical behavior of tropical residual soils reinforced with PET fibers, which were sampled in the Viçosa municipality, Minas Gerais state. Therefore, it was necessary to study different methodologies, with the execution of Characterization, Compaction, California Bearing Ratio (CBR) and Direct Shear tests. For soil samples characterization, in the first case three existing classificatory methods (MCT, TRB and USCS) were applied, and through the results achieved the differences between these were evidenced, qualifying or not the samples for paving use. The microstructural analysis tests enabled to analyze the possible relationships between chemical composition and soil engineering behavior. Furthermore, through addition of PET fibers of bottles of a same brand of refrigerant, in different percentage, widths and textures, several parameters of soil engineering behavior were investigated. It was verified by the analysis of the results of the CBR tests, that for soil reinforcement can be possible to use the soil-fiber mixtures tested according to the technical requirements of DNIT. Also, considering the adding fibers influence on the shear strength, in general, it was noted an improvement in soil-fibers mechanical properties, evidencing that the use of these in geotechnical works is promising. Finally, through the analysis of the geotechnical behavior of soil-cement reinforced with fibers and additives, it was verified improvements in the shear strength with the fibers addition for the part corresponding to cohesion, as well as that corresponding to material internal friction, in comparison to the soil-cement composites and soil-cement-additives. In addition, it was observed poor efficiency of the additives in the soil stabilization process regarding to the shear strength parameters.
2

Avaliação das técnicas de laboratório e campo para realização de ensaios de permeabilidade de solos / Evaluation of laboratory and field techniques to perform soil permeability tests

Fernandes, Marcos Túlio 10 March 2017 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2017-06-13T13:08:03Z No. of bitstreams: 1 texto completo.pdf: 5266479 bytes, checksum: 9df900f8f2b36cd9928c836253b4a1c5 (MD5) / Made available in DSpace on 2017-06-13T13:08:03Z (GMT). No. of bitstreams: 1 texto completo.pdf: 5266479 bytes, checksum: 9df900f8f2b36cd9928c836253b4a1c5 (MD5) Previous issue date: 2017-03-10 / Determinar o valor do coeficiente de permeabilidade (K) é uma das grandes premissas de diversos projetos e análises envolvendo o fluxo de água no solo, portando esse parâmetro deve ser bem caracterizado, pois este fluxo influencia no processo de infiltração em diversas obras da engenharia geotécnica. O objetivo deste trabalho foi avaliar qual técnica de ensaio reporta melhor esta propriedade do solo, as premissas de execução de cada uma, comparar os resultados dos ensaios executados em campo com os de laboratório e discutir a discrepância entre eles. Para desenvolver este estudo foram realizados ensaios em três áreas com solos distintos, todas situadas no município de Viçosa-MG; a primeira área estudada está localizada próxima à estação de tratamento de água na rua Saae, sendo esta constituída por um solo classificado como argiloso; a segunda se situa próximo ao Aeroporto, ao lado da BR 356, saída do município de Viçosa em direção a Ubá, sendo o solo presente no local considerado um silte argiloso; e a terceira área está situada dentro da Universidade Federal de Viçosa em um local conhecido como Vila Secundino e é constituída por uma areia siltosa. Nestas áreas foram executados ensaios de campo com o permeâmetro de carga constante Guelph, permeâmetro de tubo sob carga variável e infiltrômetro de anéis concêntricos, sendo todos os ensaios feitos na camada superficial do solo a 15 cm de profundidade, e também, ensaios em laboratório com o permeâmetro de parede rígida e permeâmetro de parede flexível utilizando-se a célula triaxial, em amostras indeformadas e compactadas. Foram ainda verificadas algumas correlações para coeficiente de permeabilidade em solo granular para a área do Vila Secundino. Nos ensaios com o infiltrômetro, o modelo que melhor representou a curva de velocidade de infiltração foi o de Kostiakov e Lewis, embora os demais modelos demonstrassem boa resposta; a velocidade de infiltração básica (VIB) encontrada no ensaio tendeu a ser maior do que a obtida pela equação de Kostiakov (1932) e houve uma boa aproximação do modelo de Massad (1986) com a VIB do ensaio. Com os ensaios no permeâmetro de tubo, foi possível verificar que o fator forma empregado no cálculo varia com o tipo de solo, mostrando-se menor ou maior dependendo do solo. Com o permeâmetro Guelph notou-se que a utilização do método de uma carga reporta valores similares ao de duas cargas para (K), e que a escolha do fator (α*) influencia diretamente no cálculo. Ao analisar as equações para o cálculo de (K) em solo granular verificou-se que a elaborada por Amer e Award (1974) demonstrou melhor desempenho dentre as equações analisadas. Nos ensaios de laboratório não houve uma diferença significativa dos valores de (K) encontrados com o permeâmetro de parede rígida e parede flexível, o que pode ser notado é uma tendência a redução do coeficiente de permeabilidade no solo do ETA nos ensaios executados no permeâmetro de parede flexível. Dos ensaios de campo realizados observou-se que todos reportaram valores maiores do que os de laboratório, sendo o permeâmetro Guelph o que demonstrou melhor desempenho em todas as áreas estudadas, quando comparado com os ensaios de laboratório. Notou-se ao final das análises que tratamentos estatísticos envolvendo ensaios de permeabilidade são muito difíceis devido ao alto coeficiente de variação encontrado nos ensaios, resultando apenas em uma noção de ordem de grandeza entre os valores obtidos, e que a escolha de qual ensaio utilizar, dependerá da finalidade a que o mesmo se destina. / Determining the value of the permeability coefficient (K) is one of the main assumptions of several projects and analyzes involving the flow of water in the soil, it should be well characterized, as this flow influences the infiltration process, drainage projects, check of barriers for contaminants, among other works of geotechnical engineering. The objective of this work was to evaluate which test technique reports this property of the soil better and the premises of execution of each one, comparing the results of the tests performed in the field with those of the laboratory, exemplifying the discrepancy between them. In order to develop this study, tests were carried out in three regions with distinct soils, all located in the municipality of Viçosa-MG; The first region studied is located near the water treatment plant in Saae street, which is made up of a soil classified as clayey, the second is located near the Airport, next to the BR 356, leaving the municipality of Viçosa in the direction of Ubá. The soil present in the site being considered clay silt, and the third area is present within the Federal University of Viçosa in a place known as Vila Secundino, consisting of silty sand. In these areas, field tests were carried out with the Guelph constant load permeameter, tube permeate under variable load and concentric ring infiltrator, all the tests described being done in the soil surface layer at 15 cm depth, as well as laboratory tests with the rigid wall permeameter and flexible wall permeability using the triaxial cell, in undisturbed and compacted samples, besides verifying some relations for the permeability coefficient in granular soil. In the tests with the infiltrator, the model that best represented the infiltration speed curve was that of Kostiakov and Lewis, although the other models showed good response; The VIB found in the assay tended to be greater than that of the Kostiakov equation (1932) and there was a good approximation of the Massad (1986) method with the VIB of the assay. With the test tube permeameter, we can see that the form factor used in the calculation, varies with the type of soil, showing lesser or greater depending upon the soil. With the Guelph permeameter it was observed that the use of the one- charge method reports values similar to those of two loads for (K), and that the choice of factor (α *) directly influences the calculation. When analyzing the equations for the calculation of (K) in granular soil it was verified that the one elaborated by Amer and Award (1974) demonstrated better performance among the equations analyzed. In the laboratory tests there was not a significant difference of the values of (K) found with the rigid wall permeability and flexible wall, what can be noticed is a tendency to reduce the permeability coefficient in the soil of the ETA in the tests executed in the permeameter of Flexible wall. From the field tests performed, it was observed that all reported higher values than those from the laboratory, the Guelph permeameter being the closest to the laboratory tests. It was notable at the end of the analyzes that statistical treatments involving permeability tests are very difficult due to the high coefficient of variation found in the tests, and can only have a notion of order of magnitude between the values obtained, and that the choice of which assay to use, will depend on the purpose for which it is intended.
3

Estudo da resistência não drenada de solo de baixa consistência por meio de ensaios de campo e laboratório

Lemos, Silvia Gomes Fernandes Polido 04 December 2014 (has links)
Submitted by Maykon Nascimento (maykon.albani@hotmail.com) on 2015-03-31T21:11:59Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação Silvia Gomes Fernandes Polido Lemos.pdf: 10839410 bytes, checksum: 7259030658e0a652229da5af9eebf80e (MD5) / Approved for entry into archive by Elizabete Silva (elizabete.silva@ufes.br) on 2015-04-07T19:06:20Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação Silvia Gomes Fernandes Polido Lemos.pdf: 10839410 bytes, checksum: 7259030658e0a652229da5af9eebf80e (MD5) / Made available in DSpace on 2015-04-07T19:06:20Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação Silvia Gomes Fernandes Polido Lemos.pdf: 10839410 bytes, checksum: 7259030658e0a652229da5af9eebf80e (MD5) Previous issue date: 2015-03-31 / A variabilidade natural dos solos torna complexo o conhecimento de suas propriedades na elaboração de projetos geotécnicos, sendo a determinação da resistência ao cisalhamento não drenada um parâmetro importante nas análises de estabilidade de solos moles. Os ensaios de laboratório de cone e palheta, não convencionais, os ensaios de campo de palheta e piezocone e os ensaios de compressão simples e triaxial não adensado e não drenado foram utilizados para mensurar a resistência não drenada de uma camada de argila marinha mole localizada na planície costeira central brasileira. Os ensaios de laboratório foram realizados em amostras indeformadas coletadas com amostradores de pistão estacionário em vertical próxima à realização dos ensaios de campo. O sítio foi investigado preliminarmente por sondagens de simples reconhecimento, sendo apresentado o perfil estratigráfico por meio de modelagem computacional. Foram também realizados ensaios para caracterização física (análise granulométrica, teor de umidade, limites de liquidez e plasticidade, densidade real dos grãos) e mineralógica (difração de raios X), e ensaios de adensamento para obtenção do histórico de tensões e classificação de qualidade das amostras indeformadas. Os valores de resistência não drenada obtidos pelos ensaios de laboratório foram comparados ao perfil contínuo de resistência determinado empiricamente pelo ensaio de piezocone, com fator de cone Nkt calibrado pelo ensaio de palheta de campo, apresentando boa concordância, com a variabilidade natural do solo influenciando de forma preponderante a qualidade das amostras na variação entre os resultados. Os valores de resistência obtidos pelos ensaios de laboratório de cone e palheta foram comparados entre si, apresentando boa compatibilidade. Ambos, quando comparados ao ensaio de palheta de campo, não apresentaram boa concordância. Os resultados de resistência obtidos pelos ensaios de compressão simples e triaxial apresentaram boa compatibilidade com os resultados do ensaio de laboratório de cone, o que não ocorreu com os resultados do ensaio de laboratório de palheta. Na comparação entre a resistência normalizada pela tensão de sobreadensamento obtida pelos diversos métodos e algumas correlações empíricas da literatura internacional, foi observado para as amostras de solo com índice de plasticidade superior a 60% boa concordância com as correlações de Mesri (1975) e Jamiolkowski et al (1985). Os ensaios não convencionais apresentaram boa confiabilidade, que aliado a simplicidade e agilidade de execução, justificam a difusão destes na prática da investigação geotécnica brasileira como método alternativo para complementar e dar suporte às estimativas de resistência não drenada de solos moles. / When planning a geotechnical engineering project, it is crucial to know the properties of the soil at the site; this requirement is a complex element of determining the parameters of a geotechnical project because of the the natural variability of the subsoil and the measurement of undrained shear strength is an important parameter for stability analyzes in soft soils. The fall cone test and laboratory vane test, unconventionals, the piezocone and vane tests, in situ, and the unconfined compression test and the unconsolidated undrained triaxial compression test, in laboratory, were used to measure the undrained shear strength of a layer of marine soft clay situated in the Brazilian central coastal plain. Laboratory tests were carried out in undisturbed samples collected with the stationary piston sampler in a vertical near of the field tests. The site was targeted for a campaign of standard penetration tests, with the stratigraphic profile shown through computational modeling. Were also carried out characterization tests (grain-size distribution, density of the grains, moisture content, liquidity and plasticity limits), the identification of the clay minerals using the X-ray diffraction technique and the oedometer consolidation test to obtain the stress history and for evaluating the undisturbed sample quality. The undrained strength values obtained by laboratory tests were compared to the continuous strength profile determined empirically from the piezocone, with the cone factor Nkt calibrated using the field vane test. The results presented good agreement, with the natural variability of the soil prevalent over the quality of the samples in causing the variations observed in the results. The undrained strength values obtained from fall cone and laboratory vane tests were compared, showing good compatibility. Both when compared to field vane test did not show good agreement. The undrained strength values obtained from unconfined compression test and triaxial compression test showed good compatibility with the results of fall cone test, which did not occur with the results of laboratory vane test. The values of the strength normalised with respect to the overconsolidation stress obtained using the various test methods were compared with some empirical correlations reported in the international literature, and agreement was observed with the correlations of Mesri (1975) and Jamiolkowski et al (1985) for clays samples with plasticity index greater than 60%. The unconventional tests showed good reliability, which combined the simplicity and speed of execution, justify the dissemination of these tests in Brazilian geotechnical investigation as an alternative method to complement and support the estimates of undrained shear strength of soft soils.

Page generated in 0.0587 seconds