• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Analysis of geosynthetic encased columns in very soft soil

Alkhorshid, Nima Rostami 20 June 2017 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2017-10-25T15:24:11Z No. of bitstreams: 1 2017_NimaRostamiAlkhorshid.pdf: 7386972 bytes, checksum: 238f441115959a3c09f983f6db0ef8d7 (MD5) / Approved for entry into archive by Patrícia Nunes da Silva (patricia@bce.unb.br) on 2018-06-04T14:03:43Z (GMT) No. of bitstreams: 1 2017_NimaRostamiAlkhorshid.pdf: 7386972 bytes, checksum: 238f441115959a3c09f983f6db0ef8d7 (MD5) / Made available in DSpace on 2018-06-04T14:03:43Z (GMT). No. of bitstreams: 1 2017_NimaRostamiAlkhorshid.pdf: 7386972 bytes, checksum: 238f441115959a3c09f983f6db0ef8d7 (MD5) Previous issue date: 2018-06-04 / De uma forma geral, parte das as áreas costeiras são cobertas por solos moles. Assim, a construção do aterro sobre esses solos problemáticos é sempre um desafio para engenheiros geotécnicos. Existem várias técnicas de melhoria dos solos para superar esses desafios. Nesse contexto, as colunas granulares têm apresentado sucesso para esse tipo de construção. Para solos muito moles, a aplicação de colunas granulares é de difícil execução e rendimento, tendo em vista o baixo confinamento lateral na parte superior da coluna. As colunas granuladas encamisadas com geossintéticos são uma técnica recentemente desenvolvida que tem sido utilizada com sucesso em vários projetos de aterros sobre solos moles. Esta pesquisa teve como objetivo estudar o desempenho de colunas encamisadas com diferentes tipos de materiais de encamisamento e de preenchimento das colunas. Para realizar isso, foram realizados testes laboratoriais em grande escala e também análises numéricas usando o Método dos Elementos Finitos. Foram utilizados três tipos de material de coluna (areia, brita e resíduos de construção) e também três tipos de geotêxtil tecido (G-1, G-2 e G-3) com diferentes valores de rigidez à tração. Os ensaios foram realizados com e sem encamisamento para avaliar a sua eficiência no aumento da capacidade de carga das colunas. A influência do método de instalação de vibro-deslocamento no solo circundante também foi estudada. Além disso, avaliou-se o papel das colunas na dissipação do excesso de poropressão e na pressão lateral imposta ao solo circundante. Finalmente, foram realizadas as análises dos testes laboratoriais e também a análise de uma simulação em escala real do aterro por meio do Método dos Elementos Finitos. Baseando-se nos resultados obtidos, os ensaios de laboratório indicaram que o papel do encamisamento em solos muito moles é de grande importância, pois melhorou consideravelmente o desempenho da coluna. Foi observado também que o uso de colunas de brita e de resíduo de construção aumentou a capacidade de carga comparando com a das colunas de areia, que método de instalação de deslocamento gerou excesso de poropressão e causou a densificação do solo circundante. Por sua vez, os resultados das análise numéricas mostraram boa concordância com os resultados obtidos nos ensaios. A análise numérica em escala real de um aterro indicou que as colunas próximas do meio do aterro sofriam mais recalque e que as colunas que estavam sob a talude do aterro foram mais afetadas pela deflexão lateral. / Soft soils, commonly, can be encountered in coastal areas. Thus, embankment construction on these problematic soil is always a challenge for geotechnical engineers. There are several soil improvement techniques to overcome these challenges. Granular columns is one of the popular techniques for supporting embankments. When it comes to very soft soils, the application of granular columns is almost impossible, because of the low confinement provided by the surrounding soil. Geosynthetic encased granular columns is a recently developed technique that has been successfully used in various embankment projects dealing with soft soils. This research aimed at studying the performance of encased columns with different types of the encasement and column materials. Instrumented large scale laboratory tests as well as numerical analysis using the Finite Element Method were carried out. Three types of column material (sand, gravel and construction waste) and also three types of woven geotextile (G-1, G-2 and G-3) with different tensile stiffness were tested. The tests were performed with and without encasement to evaluate the efficiency of the former in increasing the load bearing capacity of the columns. The influence of the displacement installation method on the surrounding soil was also studied. In addition, the role of columns in dissipating excess pore water pressures and imposing lateral pressures to the surrounding soil was evaluated. Finally, the back analysis of the laboratory tests and also analysis of a full-scale embankment, using the Finite Element Method, were conducted. The laboratory tests indicated that the role of encasement in very soft soils is of paramount importance, since it considerably improved the column performance. It was also observed that the displacement installation method generated excess pore water pressures and caused consolidation of the surrounding soil. The back analyzed results showed good agreement with the tests results. Ultimately, the full scale analysis of an embankment indicated that the columns which were close to the middle of embankment presented larger settlements than those under the embankment slope, which were mainly affected by lateral deflection.
2

Análise da influência de aspectos microestruturais no comportamento de solos derivados da cinza vulcânica

Hernández Menéndez, Oisy 28 October 2016 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2016. / Submitted by Camila Duarte (camiladias@bce.unb.br) on 2017-01-17T14:01:32Z No. of bitstreams: 1 2016_OisyHernandezMenendez.pdf: 5558754 bytes, checksum: 495a161180ebc3b86953f1c5cce697f6 (MD5) / Approved for entry into archive by Ruthléa Nascimento(ruthleanascimento@bce.unb.br) on 2017-03-08T20:43:56Z (GMT) No. of bitstreams: 1 2016_OisyHernandezMenendez.pdf: 5558754 bytes, checksum: 495a161180ebc3b86953f1c5cce697f6 (MD5) / Made available in DSpace on 2017-03-08T20:43:56Z (GMT). No. of bitstreams: 1 2016_OisyHernandezMenendez.pdf: 5558754 bytes, checksum: 495a161180ebc3b86953f1c5cce697f6 (MD5) / Na Colômbia os solos derivados de cinzas vulcânicas representam 11,6% dos solos do país e são utilizados em construção de terraplenagem, rodovias e taludes naturais. Apresentam uma grande variabilidade nas propriedades hidromecânicas e estruturais que dependem do grau de pré-secagem das amostras. Para analisar a variabilidade destas propriedades foi realizado um estudo teórico experimental que avaliou como as alterações mineralógicas ocasionam mudanças no comportamento hidromecânico e estrutural deste tipo de solos. Foi escolhido um solo de origem vulcânica na região de Popayán. O estudo experimental contou com um trabalho detalhado de laboratório, estudando amostras indeformadas e compactadas (com energia correspondente ao Proctor normal) com diferentes formas de preparação das amostras (com e sem secagem prévia). Da confecção da curva de compactação foram escolhidos vários pontos de trabalho aos quais foram feitos as avaliações do comportamento hidromecânico e estrutural. O estudo do solo iniciou pela caracterização físico-química, que foi realizada por meio de ensaios tradicionais da geotecnia além de DRX, espectroscopia infravermelha, análise termogravimétrica e espectroscopia mossbauer. A avaliação do comportamento hidráulico foi feita por meio da construção de curvas de retenção com trajetória de secagem e logo molhagem, combinando as técnicas de: placa, translação de eixos e WP4C. O comportamento mecânico foi avaliado por meio de ensaios de compressão oedométrica e cisalhamento direto. Entretanto, o comportamento estrutural foi avaliado por meio da combinação de três técnicas de caracterização, a microscopia eletrônica de varredura para os microporos, a porosimetria por adsorção e dessorção de nitrogênio para os mesoporos e a microscopia por intrusão de mercúrio para os macroporos. O estudo experimental permitiu demostrar que a secagem das amostras afeta a estrutura mineralógica do solo ocasionando mudanças na granulometria e plasticidade. As duas formas de preparação de amostras geraram duas curvas de compactação totalmente diferentes. O comportamento hidráulico das amostras sem secagem prévia apresentou uma histeresis elevada. A compressibilidade das amostras sem secagem prévia foi maior que as amostras com secagem prévia. Finalmente a análise da estrutura do solo mostrou que a compactação e secagem diminui os macroporos mas não afeta os mesoporos, e os microporos são mais visíveis na estrutura com secagem prévia. / In Colombia volcanic ash soils represent 11.6% of the country's and are used in construction of earthworks, roads and natural slopes. These soils show a great variability in hydromechanical and structural properties that depend on the degree of pre-drying of samples. To analyze the variability of these properties was realized an theoretical-experimental study that assessed how the mineralogical changes caused changes in hydromechanical and structural behavior. The local of the extraction of the sample was in Popayan region. The experimental study included a detailed laboratory work, for undisturbed and compacted samples (with energy corresponding to normal Proctor) with different forms of sample preparation (with and without drying). Two diferent compactation curves was constructed and which chosen several points for the evaluations of hydromechanical and structural behavior. For the physical and chemical characterization was used basic geotechnics tests and DRX, infravermelha spectroscopy, Mossbauer spectroscopy and thermogravimetric analysis. The hydraulic behavior was made by constructing retention curves with wetting and drying trajectories, combining different techniques: plate, translational axes and WP4C. The mechanical behavior was assessed by oedométrica compression tests and direct shear. However, the structural behavior was assessed by the combination of three characterization techniques, scanning electron microscopy for the micropores, the porosimetry adsorption and desorption of nitrogen to the mesoporous and microscopy by mercury intrusion to the macropores. The experimental study demonstrate that drying of the samples affects the mineralogical structure of the soil causing changes in particle size and plasticity. The two ways of preparation of samples generated two entirely different compactation curves. The hydraulic behavior of the samples without prior drying had a high hysteresis. The compressibility of the samples without prior drying was higher than the samples prior to drying. Finally, the analysis of the soil structure showed that compression and drying reduces the macropores but does not affect the mesopores, and micropores are more visible in the structure prior to drying.

Page generated in 0.1479 seconds