• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • Tagged with
  • 12
  • 12
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação da efetividade de diferentes protocolos de irrigação na limpeza do canal radicular / Evaluation of the effectiveness of different irrigation protocols in the root canal cleaning

Samuel Lucas Fernandes 15 June 2015 (has links)
O objetivo desse estudo foi avaliar a capacidade de dissolução e remoção de biofilme formado in situ, na remoção de smear layer e debris empregando dez protocolos de irrigação final (solução fisiológica com ou sem agitação ultrassônica; ou hipoclorito de sódio como irrigante primário, seguido de solução salina, ou EDTA 17%, ou ácido peracético (PAA) 2%, ou Qmix, com ou sem agitação ultrassônica de ambas as soluções). Duzentos e trinta raízes bovinas foram seccionadas e cortadas com 15mm de comprimento e instrumentadas com o instrumento Reciproc R50. Para a análise da remoção de debris e smear layer foram separadas 100 raízes, que foram clivadas e, no terço apical de uma das metades radiculares, foi confeccionado um sulco longitudinal, simulando extensões de canais ovais, posteriormente preenchidos com detritos artificiais. Após esse procedimento na outra metade foi realizada a formação de smear layer com uma vigora instrumentação da parede com movimentos de limagem. Essas amostras foram levadas ao MEV para análise prévia. Essas metades, depois de justapostas, voltaram a mufla e foram realizados os protocolos de tratamento. A análise dos dados foi realizada por meio de scores. Para a análise da dissolução e viabilidade do biofilme in situ 130 raízes foram separadas preparadas com instrumento R25 e um disco de dentina foi retirado do terço médio com uma trefina. Esses discos foram inseridos em uma placa de hawley, que foi utilizada pelo pesquisador durante três dias. Os discos foram removidos e deixados por 48 horas em BHI, em estufa a 37oC. Após a contaminação os discos voltaram para a raiz de onde foram removidos e fixados com cera utilidade voltando a mufla, sendo tratados e avaliados. Setenta discos foram utilizados para análise da dissolução e viabilidade em confocal e as imagens obtidas foram avaliadas pelo software Bioimage. Sessenta discos foram utilizados para a análise da dissolução do biofilme em MEV, sendo avaliados pré e pós-tratamento. Na comparação entre os grupos para a remoção de smear layer foram encontradas diferenças estatisticamente significantes (P < 0.05) entre os protocolos que utilizavam EDTA e Qmix, com os protocolos utilizando somente solução salina e hipoclorito seguido de solução salina independente da agitação ultrassônica. Enquanto que para a ranhura houve uma diferença estatisticamente significativa entre os grupos que utilizaram PUI e os demais grupos. Tanto a agitação ultrassônica, quanto o uso do hipoclorito de sódio como irrigante primário influenciaram significativamente para a redução do biovolume e da viabilidade bacteriana. O grupo que utilizou o NaOCl, seguido do Qmix associados ao PUI apresentou os menores valores de viabilidade e a maior dissolução do biofilme. O QMix PUI e o PAA/PUI mostraram os melhores resultados de dissolução na análise em MEV.se diferenciando estatisticamente (P<0.05) dos demais grupos. Levando-se em conta todos os critérios analisados, o protocolo que se mostrou mais eficiente foi o NaOCl seguido do QMix e associados a PUI. / The aim of this study was to evaluate the dissolution capacity and removal of biofilm formed in situ, in smear layer and debris removal and debris use ten final irrigation protocols (saline with or without ultrasonic agitation, or sodium hypochlorite as primary irrigating, and then used saline or 17% EDTA, or 2% peracetic acid (PAA), or Qmix, with or without ultrasonic agitation of both solutions). Two hundred and thirty bovine roots were sectioned and cut with 15mm in length and instrumented with Reciproc R50. For the analysis of removal of debris and smear layer were separated 100 roots, which were cleaved, and the apical third of the half of root, has a longitudinal groove made simulating extensions of oval canals, artificial subsequently filled with debris. After this procedure was performed on half the formation of smear layer with a force wall with instrumentation filing motions. These samples were taken to SEM prior to analysis. These halves, after juxtaposed, and again the flask were held treatment protocols. Data analysis was performed by means of scores. For the analysis of the dissolution and viability of the biofilm in situ roots 130 were prepared with R25 separate instrument and dentin disc was taken from the middle third with a trephine. These disks were inserted into a hawley plate, which was used by the researcher for three days. The discs were removed and left for 48 hours in BHI at 37oC. After contamination disks back to the root from which they were removed and fixed with wax utility returning to muffle being treated and evaluated. Seventy disks were used for analysis of dissolution and viability and confocal images were evaluated by Bioimage software. Sixty discs were used for the analysis of the dissolution of the biofilm SEM and are assessed before and after treatment. Comparing the groups for the removal of smear layer statistically significant differences were found (P <0.05) between the protocols used EDTA and Qmix with the protocols using only saline solution and hypochlorite followed by saline independent of ultrasonic agitation. While for the slot there was a statistically significant difference between the groups using PUI and the other groups. Both ultrasonic agitation, and the use of sodium hypochlorite as primary irrigant influenced significantly to the reduction of bacterial viability and biovolume. The group using the NaOCl, and then used Qmix associated with PUI had the lowest viability values and the highest dissolution of the biofilm. The QMix PUI and the PAA / PUI showed the best dissolution results in the analysis MEV.se differentiating statistically (P <0.05) from the other groups. Taking into account all the criteria analyzed, the protocol that was more efficient was the NaOCl and then used QMix and associated with PUI.
12

EFEITO DE SOLUÇÕES ATIVADAS POR ULTRASSOM NA RESISTÊNCIA ADESIVA DE PINOS DE FIBRA DE VIDRO CIMENTADOS COM CIMENTO RESINOSO AUTOADESIVO / EFFECT OF INTRACANAL IRRIGANTS ON BOND STRENGH OF FIBER POSTS CEMENTED WITH A SELF-ADHESIVE RESIN CEMENT

Barreto, Mirela Sangoi 07 July 2015 (has links)
The current study aimed to evaluate the effect of irrigating and chelating solutions on bond strength of fiber glass posts cemented with RelyX U200. 60 single-rooted premolars were sectioned at 14 mm from the apex, prepared with ProTaper Universal system until F3 instrument and filled with F3 master cone and AH Plus sealer. Root canal filling was partially removed, remaining 4 mm of guta-percha at the apical third. Specimens were randomly divided into 5 experimental groups (n=12), according to the solution used before fiber post cementation (dentin surface treatment), as described: EDTA 17% (EDTA); QMix (QM); SmearClear (SC); NaOCl 2.5% (NaOCl) and saline solution as control group (SS). Ultrasonic activation was performed three times, during 20 seconds each and root canals were dried with paper points. Exacto N2 glass fiber posts were cemented with RelyX U200. Rhodamine B dye was mixed to RelyX U200 in one specimen per group, in order to provide fluorescence for confocal laser scanning microscopy (CLSM) assessment. A cutting machine was used for root s sectioning, providing 3 slices, one for each root third. Next, push-out test was performed. Stereomicroscope and CLSM were used to analyze the failure mode and to illustrate the pattern of distribution of RelyX U200 inside dentinal tubules, respectively. Bond strength mean were calculated and ANOVA and Bonferroni tests were used for statistical analysis. SS showed the higher mean of bond strength values, superior to QM, SC (P < .05). NaOCl presented intermediary bond strength values, similar to EDTA and SS (P > .05). QM and SC showed the lowest mean of bond strength (P < .05). In conclusion, SS and NaOCl associated to ultrasonic activation seems to be adequate solutions for root canal cleaning before fiber post cementation with RelyX U200, while chelating solutions, such as EDTA, QMix and SmearClear, should not be used for dentin pre-treatment when cementing with RelyX U200. / O presente estudo tem por objetivo avaliar o efeito de diferentes soluções irrigantes e quelantes na resistência adesiva de pinos de fibra de vidro cimentados com cimento autoadesivo RelyX U200. 60 pré-molares inferiores extraídos de humanos, padronizados em 14 mm, foram preparados com o sistema ProTaper Universal até o instrumento F3, obturados com cimento AH Plus e cones F3 do mesmo sistema. Os espécimes foram desobturados parcialmente, restando 4 mm apicais de material obturador e realocados em quatro grupos experimentais e um controle (n=12), de acordo com a solução de tratamento de superfície dentinária prévia à cimentação dos pinos: EDTA 17% (EDTA), QMix (QM), SmearClear (SC), Soro Fisiológico (SS) e NaOCl 2,5% (NaOCl). As soluções foram ativadas por ultrassom em três etapas, durante 20 segundos cada e os canais foram secos com pontas de papel absorventes. Os pinos de fibra de vidro do Sistema Exacto Translúcido N2 foram cimentados com RelyX U200. Em um espécime por grupo foi incorporada Rodamina B ao cimento autoadesivo como marcador fluorescente para análise em Microscopia Confocal à laser (MECL). Foram seccionados 3slices por espécime, sendo 1 slice por terço radicular, e submetidos ao teste de push-out na máquina de ensaio universal EMIC. Estereomicroscópio e MECL foram utilizados para analisar o padrão de falha dos espécimes e o padrão de penetração do cimento autoadesivo nos túbulos dentinários, respectivamente. A média de resistência adesiva de cada espécime foi calculada. Testes ANOVA e Bonferroni foram utilizados para analisar as diferenças entre os grupos. SS demonstrou a maior média de resistência adesiva, sendo superior aos grupos QM, SC (P <.05). NaOCl apresentou valores intermediários de resistência adesiva, similares ao EDTA e SS (P > .05). QM e SC apresentaram as menores médias de resistência adesiva (P < .05). Pode-se concluir que o uso de SS e NaOCl parece ser adequado para lavagem do canal prévia à cimentação de pinos de fibra de vidro, com uso de cimento resinoso autoadesivo RelyX U200. O uso de soluções quelantes como EDTA, QM e SC parece interferir negativamente nos valores de resistência adesiva.

Page generated in 0.0629 seconds