• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

CONFIABILIDADE DOS PARÂMETROS MONITORADOS EM ÁGUAS POR SONDA MULTIPARÂMETROS / RELIABILITY OF PARAMETERS MONITORED IN WATER WITH MULTIPARAMETER PROBE

Mendonça, Angela Maria 04 March 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Concern over water quality in Brazil is being hotly debated currently. In order to obtain information about the water quality at the national level, it was created the National Program for Assessment of Water Quality (PNQA). This program is the main axis of the National Network for Water Quality Monitoring (RNQA). To obtain water quality data and to create a standardized procedure, multiparameter probes were delivered to the federations, which allow determining the quality in real time through a few parameters. The multiparameter probes are presented in the market to supply the basics requirements to determine water quality with standardization, and the cost for the adoption of these probes will depend on the parameters. The more parameters evaluated, the higher its cost and it can derail monitoring. The basic probes simultaneously evaluate parameters such as dissolved oxygen, conductivity, total suspended solids, redox potential, temperature, pH and turbidity. These parameters allow inferences about the water quality and it has the advantage of providing results within minutes. However, the results are reliable? In this context, the aim of this thesis was to evaluate the reliability of the data presented by the multiparameter probe for monitoring of surface water, which was determined and compared to the results presented by multiparameter probe mark Aquaread AP 1000 with used equipment and methodologies by traditional laboratories. The time of immersion of the probe was determined for all its parameters were stabilized, the transport time so that did not occur changes in the sample values determined in field, we compared their readings with traditional methods and created a protocol probe operation. The results presented in research showed that the average time recommended for stabilization of parameters is 20 minutes. Regarding the conservation of water samples collected in the field, there was no significant difference in the readings over time. The multiparameter probe showed no reliable values in order to assert the water quality due to a high discrepancy between individual equipment, laboratory analysis regarding the probe, being a correction of each parameter required. / A preocupação com a qualidade da água no território brasileiro está sendo muito debatida atualmente. Com o objetivo de obter informações sobre a qualidade da água no âmbito nacional, criou-se o Programa Nacional de Avaliação da Qualidade das Águas (PNQA). Esse programa é o principal eixo da Rede Nacional de Monitoramento de Qualidade das Águas (RNQA). Para obter os dados da qualidade da água e para que houvesse uma padronização metodológica, foram entregues às federações sondas multiparâmetros, as quais permitem determinar a qualidade da água em tempo real através da leitura de alguns parâmetros. As sondas multiparâmetros apresentam-se no mercado para suprir as exigências básicas para a determinação da qualidade da água, com uma padronização, sendo que o custo para a adoção dessas sondas dependerá dos parâmetros a serem lidos. Quanto mais parâmetros avaliados, maior será seu custo, podendo inviabilizar o monitoramento. As sondas básicas avaliam ao mesmo tempo parâmetros como: oxigênio dissolvido, condutividade elétrica, sólidos totais em suspensão, potencial redox, temperatura, pH e turbidez. Esses parâmetros permitem inferir sobre a qualidade da água tendo como vantagem disponibilizar os resultados em alguns minutos. Porém, os resultados apresentados são confiáveis? Neste contexto, objetivou-se com esta dissertação avaliar a confiabilidade dos dados apresentados pela sonda multiparâmetros para o monitoramento de águas superficiais, determinou-se e comparou-se estatisticamente os resultados apresentados pela sonda multiparâmetros da marca Aquaread AP 1000 com equipamentos e metodologias utilizados por laboratórios tradicionais. Foram determinados: o tempo de submersão da sonda para que todos os seus parâmetros fossem estabilizados e ainda o tempo de transporte para que não ocorresse alteração dos valores das amostras determinadas a campo, compararam-se suas leituras com os métodos tradicionais e criou-se um protocolo de operação da sonda. Os resultados apresentados na pesquisa mostraram que o tempo médio indicado para a estabilização dos parâmetros é de 20 minutos. Em relação à conservação das amostras de águas coletadas a campo, não se observou diferença significativa com as leituras no decorrer do tempo. A sonda multiparâmetros não apresentou valores confiáveis a fim de afirmar a qualidade da água, pois ocorreu uma alta discrepância entre os equipamentos individuais, análise de laboratório em relação à sonda, sendo necessária uma correção de cada parâmetro.
2

ESTRATÉGIA DE MONITORAMENTO EM APOIO AO LICENCIAMENTO AMBIENTAL EM TRECHO DE VAZÃO REDUZIDA / MONITORING STRATEGY FOR SUPPORTING THE ENVIRONMENTAL LICENSING IN REDUCED FLOW REACH

Silva, Regis Leandro Lopes da 05 November 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In the environmental licensing of hydroelectric plants are prescribed streamflow should be maintained downstream of the dam, but these flows often cannot ensure the maintenance of water quality for the stretch. The aim of this study is to present a robust and expeditious strategy of water quality monitoring. This strategy is developed for supporting the stipulation of flow regime in reduced flow reach (RFR) by dams. The Hydropower plant Passo São João (HPP PSJ) in Rio Ijuí-RS was used as study case. This Hydropower is a power plant without storage capacity presenting a RFR of 4 km. The monitoring for collecting water quality data is made by using a multiparameter probe and laboratory analysis. It is used ten monitoring points along the Rio Ijuí, two of them located in the RFR. Correlations between data obtained with a multiparameter probe and data determined in the laboratory are made to evaluate the application of the probe. Complementing the study, the HPP PSJ is contextualized according to the impact on water quality in the Rio Ijuí, tracing a longitudinal profile of dissolved oxygen (DO) along with the evaluation of the direct contribution by RFR comparison of flows. Moreover, the variability of DO concentrations in sections monitoring RFR is evaluated considering the determinations along the section. Those sections are associated with flow velocity profiles that were determined by the Acoustic Doppler Current Profiler (ADCP). The correlations between the curves of monitoring data and curves from the extraction of data - at different frequencies - are developed for determining the optimal monitoring frequency. The comparison between measurements with the probe and measurements in the laboratory are satisfactory, presenting similar values for most parameters. The layout of the longitudinal profile of the DO concentrations demonstrates the strong influence of the HPP PSJ structures in dam downstream DO level, reinforcing the need for a monitoring strategy. However the effect of reducing inflow in the dilution charges has not been noted in view of the minimum incremental area flow. Near riverbank measurements were representative, since the variability of measurements along the section generally was less than 2% on average. Finally the ideal frequency obtained with the correlation curves for different frequencies is four days for both points of RFR. The overall conclusion of this study is to propose a monitoring strategy based on using a multiparameter probe in which the operator formulates the determinations near the riverbank with a monitoring frequency of four days, taking as basis the representative parameter the dissolved oxygen for this case. / Quando do licenciamento ambiental de usinas hidrelétricas, são prescritas vazões a serem mantidas a jusante do barramento, que muitas vezes podem não garantir a manutenção da qualidade da água para o trecho. O objetivo deste estudo foi propor uma estratégia expedita de monitoramento da qualidade da água em suporte a prescrição de regime de vazões remanescentes em trechos de vazão reduzida (TVR) por barramentos. Para tanto foi utilizado como caso de estudo a UHE Passo do São João (UHE PSJ) no Rio Ijuí-RS, que opera a fio d água e possui um TVR de 4 km. Como base do estudo foi feito um monitoramento para levantamento de dados de qualidade da água com a utilização de sonda multiparâmetro e análises em laboratório. Foram utilizados 10 pontos de monitoramento ao longo do Rio Ijuí, sendo 2 deles, os principais no estudo, localizados no TVR. Foram feitas correlações entre os dados obtidos com a sonda multiparâmetro e determinados em laboratórios para avaliação do uso da sonda. Complementando o estudo, foi feita uma contextualização da UHE PSJ no que se refere ao impacto na qualidade da água no Rio Ijuí, traçando um perfil longitudinal de concentração de oxigênio dissolvido (OD), juntamente com a avaliação do aporte direto ao TVR por meio da comparação de vazões. Ainda foi realizada uma avaliação da variabilidade das concentrações de OD nas seções de monitoramento do TVR, com determinações ao longo da seção, associadas aos perfis de velocidade do escoamento determinados com o uso de Acoustic Doppler Current Profiler (ADCP). Por fim foram realizadas correlações entre as curvas dos dados do monitoramento e curvas resultantes da extração de dados com diferentes frequências, para a determinação da frequência ideal de monitoramento. A comparação entre as determinações com a sonda e no laboratório foi satisfatória, mostrando valores próximos para a maioria dos parâmetros. O traçado do perfil longitudinal das concentrações de OD mostrou a forte influência das estruturas da UHE PSJ nos níveis de OD a jusante do barramento no TVR, reforçando a demanda por uma estratégia de monitoramento. Porém o efeito da redução das vazões na diluição de cargas não foi notado, tendo em vista a insignificância das vazões da área incremental ao TVR. As medições próximas a margem foram representativas, pois a variabilidade das determinações ao longo da seção em geral foi menor que 2% em relação a média. Por fim a frequência ideal obtida com a correlação das curvas de diferentes frequências foi de 4 dias para os dois pontos do TVR. Como conclusão geral deste estudo, fica a proposição de uma estratégia de monitoramento, baseada na utilização de uma sonda multiparâmetro, onde o operador fará as determinações próximas a margem do rio, com uma frequência de monitoramento de 4 dias, tendo como base um parâmetro representativo, no caso o oxigênio dissolvido.

Page generated in 0.0725 seconds