• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Identification de marqueurs épidémiologiques par spectrométrie de masse de type MALDI-TOF : application aux principales espèces bactériennes responsables d'infections nosocomiales / Identification of epidemiological markers by MALDI-TOF mass spectrometry : application to the main species responsible for nosocomial infections

Sauget, Marlène 18 November 2016 (has links)
Le typage bactérien est une mesure de contrôle essentielle pour lutter contre la diffusion des bactéries multirésistantes, mais les techniques actuelles sont longues et coûteuses. L'objectif de cette thèse était d'évaluer la capacité de la technique MALDI-TOF MS à typer les 3 principales espèces bactériennes responsables d'infections nosocomiales - Escherichia coli, Staphylococcus aureus et Pseudomonas aeruginosa. L'analyse par MALDI-TOF MS permet d'identifier les souches de E. coli appartenant au phylogroupe B2, souches les plus virulentes parmi les souches extra-intestinales, et au STI 31, clone très impliqué dans la dissémination des P-lactamases à spectre étendu. Chez S. aureus, cette technique reconnait les souches appartenant au CC398, impliquées dans une proportion importante d'infections graves chez des personnes fragiles. La technique MALDI-TOF MS identifie également cinq clones de P. aeruginosa à haut risque épidémique - STI 11, STI 75, ST235, ST253, ST395. Si nous avons confirmé des pics caractéristiques du phylogroupe B2 décrit également par d'autres auteurs, les pics biomarqueurs identifiant E. coli ST131 ou des clones épidémiques de S. aureus varient suivant les études. Différents paramètres peuvent influencer les résultats de typage par MALDI-TOF MS et doivent donc être standardisés. La technique MALDI-TOF MS permet d'identifier certains clones épidémiques. En gardant à l'esprit que le choix d'une méthode de typage doit être fait en fonction des objectifs mais aussi des performances des différents systèmes disponibles, la technique MALDI-TOF MS pourrait se positionner comme un outil de typage de première ligne. / Bacterial typing is crucial to tackle the spread of bacterial pathogens but current methods are time-consuming and costly. The objective of this study was to evaluate the ability of MALDI-TOF MS to type the 3 main bacterial species re.sponsible for nosocomial infections - Escherichia coti, Staphylococcus aureus and Pseudomonas aeruginosa. Analysis of MALDI-TOF mass spectra allow the identification (i) of E. coti isolates belonging to phylogroup B2, that fosters the most virulent extra-intestinal strains, and (ii) of E. coli STl 31, a clone involved in the dissemination of extended-spectrum β-lactamases. MALDI-TOF MS also recognizes S. aureus isolates belonging to CC398, a pathogen responsible for invasive infections in fragile patients and associated with a higher 30-day mortality. Furthermore the MALDI-TOF MS based typing method identifies the major high risk epidemic clones of P. aeruginosa STl 11, STl 75, ST235, ST253, and ST395. We confirmed phylogroup B2 specific peaks also described by other authors. However the identification of E. coli STl 31 or epidemic clones of S. aureus is based on biomarkers that differs between studies. Different parameters can influence the MALDI-TOF MS typing results and must therefore be standardized. MALDI-TOF-based typing methods allow the detection of epidemic pathogens. Keeping in mind that the choice of a method for routine bacterial typing should be made according to the objectives but also the performance of the different systems available, the MALDI-TOF MS technique could become a first-line typing method.
2

Etude de la violation de la symétrie CP dans les canaux charmonium-K^*(892) par une analyse angulaire complète dépendante du temps (expérience BaBar)

T'Jampens, Stéphane 18 December 2002 (has links) (PDF)
Les travaux présentés dans cette thèse décrivent l'analyse angulaire complète dépendante du temps du canal vecteur-vecteur B_d^0 -> J/Psi (K_S^0 Pi^0)*0. Après un rappel consacré à la violation de CP dans le système des mésons B est traitée la phénoménologie des canaux vecteur-vecteur du type charmonium-K*(892). La méthode pour la mesure des amplitudes de transversité des canaux B -> J/Psi K*(892), basée sur l'utilisation d'un pseudo-maximum de vraisemblance, est ensuite exposée. Les résultats obtenus avec 81.9 fb-1 de données collectées par le détecteur BABAR au pic de la résonance Upsilon(4S) sont |A_0|^2 = 0.565 +- 0.011 +- 0.004, |A_para|^2 = 0.206 +- 0.016 +- 0.007, |A_perp|^2 = 0.228 +- 0.016 +- 0.007, delta_para = -2.766 +- 0.105 +- 0.040 et delta_perp = 2.935 +- 0.067 +- 0.040. A noter que (delta_para, delta_perp) -> (-delta_para, Pi - delta_perp) est aussi une solution. Les phases fortes delta_para et delta_perp sont à > 3 sigma de factorisation. L'analyse de l'asymétrie avant-arrière en fonction de la masse K Pi a révélé la présence d'une onde S cohérente qui interfère avec le K*(892). C'est la première mise en évidence de la présence de cette onde dans le système K Pi provenant de la désintégration d'un méson B. La particularité du canal B_d^0 -> J/Psi (K_S^0 Pi^0)*0 est d'avoir une distribution qui dépend de la différence des temps propres des 2 mésons B provenant de la désintégration Upsilon(4S) -> B_d^0 Bbar_d^0 mais aussi des trois angles de transversité, permettant de mesurer sin 2beta mais aussi cos 2beta. Les résultats obtenus avec un ajustement par maximum de vraisemblance sont sin 2beta = -0.10 et cos 2beta = 3.32 avec les amplitudes de transversité fixées aux valeurs précédentes. L'autre solution pour les phases fortes conduit à la même valeur de sin 2beta mais change le signe de cos 2beta. Des considérations théoriques basées sur la conservation de l'hélicité du quark favorisent le choix des phases fortes données ci-dessus conduisant au signe positif pour cos 2beta. Ce signe de cos 2beta est celui prédit par le Modèle Standard.

Page generated in 0.0553 seconds