• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 209
  • 48
  • 41
  • 28
  • 17
  • 9
  • 8
  • 8
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • Tagged with
  • 453
  • 113
  • 54
  • 47
  • 46
  • 38
  • 36
  • 35
  • 32
  • 30
  • 30
  • 30
  • 29
  • 29
  • 28
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Design of a Bore Sight Camera for the Lineate Image Near Ultraviolet Spectrometer (LINUS) /

Cabezas, Rodrigo. January 2004 (has links) (PDF)
Thesis (M.S. in Applied Science)--Naval Postgraduate School, June 2004. / Thesis advisor(s): Richard Harkins, D. Scott Davis. Includes bibliographical references (p. 61). Also available online.
42

DEVELOPMENT OF A SPECTROMETER FOR THE ELECTROREFLECTANCE SPECTROSCOPY OF METALS

Rancourt, James Daniel, 1941- January 1974 (has links)
No description available.
43

Fundamental studies of MALDI with an orthogonal TOF mass spectrometer

Qiao, Hui 30 January 2009 (has links)
The interaction between the matrix and analyte molecules are studied with a high resolution MALDI imaging technique in an orthogonal-injection TOF mass spectrometer. The analyte incorporation and distribution patterns have been clearly demonstrated. Purified protein analytes were found to be homogeneously incorporated in large single crystals of DHB and sinapinic acid matrices, with no evidence for preferred crystal faces. Segregation of some species was observed and appeared to correlate with analyte hydrophobicity, and to a lesser extent analyte mass or mobility. The influence of incident laser parameters on sensitivity in MALDI has been investigated using orthogonal-injection time-of-flight (TOF) instruments. A qualitative comparison was first made between the beam profiles obtained with a N2 laser and a Nd:YAG laser using 2-m long optical fibers. The N2 laser gives better sensitivity, consistent with a more uniform fluence distribution and therefore better coverage of the N2 laser profile. Most of the difference disappears when a 30-m long fiber is used or when the fibers are twisted during irradiation to smooth out the fluence distribution. In more systematic measurements, the total integrated ion yield from a single spot (a measure of sensitivity) was found to increase rapidly with fluence to a maximum, and then saturate or decrease slightly. For a fluence near threshold, the integrated yield has a steep (cubic) dependence on the spot size, but the yield saturates at higher fluence for smaller spots. The area dependence is much weaker (close to linear) for fluence values above saturation, with the result that the highest integrated yields per unit area are obtained with the smallest spot sizes. Finally the detection properties of the MCP detector were studied with a hybrid MCP and CuBe venetian blind converter detector. The measurements show that the detection efficiency of the MCP drops with the increasing of ion mass and the decreasing of the ion energy. The secondary electron emission coefficient of the MCP shows a linear dependence on mass and a power law dependence on velocity (~ 3.2). No clear velocity threshold is observed for secondary electron emission.
44

A beta spectrometer using a GE (HP) detector in a high magnetic field /

Al-Alousi, Ali Khalil January 1984 (has links)
No description available.
45

Precise mass measurements of Cf252 fission fragments with the Canadian penning trap mass spectrometer (CPTMS)

Wang, Yuyan 28 March 2007 (has links)
The Canadian Penning Trap Mass Spectrometer (CPTMS) located at the ATLAS (Argonne Tandem Linear Accelerator System) facility of Argonne National Laboratory makes precise mass measurements on both stable and unstable isotopes. A 252Cf fission source has been used as the ion source for the unstable isotope mass measurements. This thesis concentrates on the mass measurements of the fission fragments from the 252Cf fission source using the CPTMS system. It is the first time that the masses of such fission fragments have been measured with a mass spectrometer. The masses of 108Tc, 108Ru, 109Ru and 110Ru have been measured to a precision of 10-7. The results have been compared to exiting mass measurements and the Atomic Mass Evaluation (AME2003). In general good agreement between this work and existing data is realized. A few discrepancies are identified.
46

Fundamental studies of MALDI with an orthogonal TOF mass spectrometer

Qiao, Hui 30 January 2009 (has links)
The interaction between the matrix and analyte molecules are studied with a high resolution MALDI imaging technique in an orthogonal-injection TOF mass spectrometer. The analyte incorporation and distribution patterns have been clearly demonstrated. Purified protein analytes were found to be homogeneously incorporated in large single crystals of DHB and sinapinic acid matrices, with no evidence for preferred crystal faces. Segregation of some species was observed and appeared to correlate with analyte hydrophobicity, and to a lesser extent analyte mass or mobility. The influence of incident laser parameters on sensitivity in MALDI has been investigated using orthogonal-injection time-of-flight (TOF) instruments. A qualitative comparison was first made between the beam profiles obtained with a N2 laser and a Nd:YAG laser using 2-m long optical fibers. The N2 laser gives better sensitivity, consistent with a more uniform fluence distribution and therefore better coverage of the N2 laser profile. Most of the difference disappears when a 30-m long fiber is used or when the fibers are twisted during irradiation to smooth out the fluence distribution. In more systematic measurements, the total integrated ion yield from a single spot (a measure of sensitivity) was found to increase rapidly with fluence to a maximum, and then saturate or decrease slightly. For a fluence near threshold, the integrated yield has a steep (cubic) dependence on the spot size, but the yield saturates at higher fluence for smaller spots. The area dependence is much weaker (close to linear) for fluence values above saturation, with the result that the highest integrated yields per unit area are obtained with the smallest spot sizes. Finally the detection properties of the MCP detector were studied with a hybrid MCP and CuBe venetian blind converter detector. The measurements show that the detection efficiency of the MCP drops with the increasing of ion mass and the decreasing of the ion energy. The secondary electron emission coefficient of the MCP shows a linear dependence on mass and a power law dependence on velocity (~ 3.2). No clear velocity threshold is observed for secondary electron emission.
47

Precise mass measurements of Cf252 fission fragments with the Canadian penning trap mass spectrometer (CPTMS)

Wang, Yuyan 28 March 2007 (has links)
The Canadian Penning Trap Mass Spectrometer (CPTMS) located at the ATLAS (Argonne Tandem Linear Accelerator System) facility of Argonne National Laboratory makes precise mass measurements on both stable and unstable isotopes. A 252Cf fission source has been used as the ion source for the unstable isotope mass measurements. This thesis concentrates on the mass measurements of the fission fragments from the 252Cf fission source using the CPTMS system. It is the first time that the masses of such fission fragments have been measured with a mass spectrometer. The masses of 108Tc, 108Ru, 109Ru and 110Ru have been measured to a precision of 10-7. The results have been compared to exiting mass measurements and the Atomic Mass Evaluation (AME2003). In general good agreement between this work and existing data is realized. A few discrepancies are identified.
48

Optical studies of thermoluminescent materials /

Fox, Phillip James. January 1990 (has links) (PDF)
Thesis (Ph. D.)--University of Adelaide, Dept. of Physics and Mathematical Physics, 1990. / Includes bibliographical references (leaves 120-127).
49

Design and implementation of ultra-high resolution, large bandwidth, and compact diffuse light spectrometers

Badieirostami, Majid. January 2008 (has links)
Thesis (Ph.D)--Electrical and Computer Engineering, Georgia Institute of Technology, 2009. / Committee Chair: Adibi, Ali; Committee Member: Bhatti, Pamela; Committee Member: Callen, William; Committee Member: Gaylord, Thomas; Committee Member: Zhou, Hao-Min. Part of the SMARTech Electronic Thesis and Dissertation Collection.
50

Multielement atomic fluorescence flame spectrometry evaluation of a pulsed EIMAC Continuum source and characterization of background molecular fluorescence /

Fowler, William Kelly, January 1976 (has links)
Thesis--University of Florida. / Description based on print version record. Typescript. Vita. Includes bibliographical references (leaves 80-83).

Page generated in 0.154 seconds