• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 28
  • 9
  • 5
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 51
  • 19
  • 10
  • 9
  • 8
  • 8
  • 8
  • 8
  • 8
  • 8
  • 8
  • 8
  • 8
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A Spectrophotometric Determination of Barium Complexation with Methylthymol Blue

Alexander, Wesley 01 June 2022 (has links)
No description available.
2

Desenvolvimento de métodos espectrofotométricos de análise de flavonóides do \"maracujá\" (Passiflora alata e Passiflota edulis) / Development of a spectrophotometric method for the quantification of maracuja\'s flavonoids (Passiflora alata and Passiflora edulis)

Pozzi, Alessandra Cristina Soares 09 March 2007 (has links)
\"Maracujá\" é o nome popular de várias espécies, dentre as quais Passiflora edulis e Passiflora alata (Passifloraceae). Esta última é uma planta medicinal amplamente utilizada no Brasil devido às suas propriedades ansiolíticas e sedativas, sendo também a espécie oficial da Farmacopéia Brasileira. Porém, freqüentemente ocorre a sua substituição indevida por Passiflora edulis, espécie usada para o preparo de sucos. Há também a confusão com a Passiflora incarnata, espécie usada na Europa, mas que não se adapta bem ao clima brasileiro. Neste trabalho foi desenvolvido um método espectrofotométrico por UV-visível para a quantificação dos flavonóides totais contidos nas folhas de Passiflora alata e de Passiflora edulis, a partir da adaptação das metodologias descritas nas Farmacopéias Francesa, Helvética e Européia para a espécie Passiflora incarnata. O procedimento proposto envolveu a complexação dos flavonóides com cloreto de alumínio e foi utilizada a rutina como padrão. Confrontou-se os dados obtidos pelo método espectrofotométrico desenvolvido neste trabalho com os obtidos por HPLC. Os melhores resultados foram obtidos com a metodologia adaptada da Farmacopéia Francesa. / \"Maracujá\" is the popular name of some species, among which are Passiflora edulis and Passiflora alata (Passifloraceae). The latter is a widely used medicinal plant in Brazil due to its ansiolytic and sedative properties, and also the official species of the Brazilian Pharmacopoeia. However, it is quite often improperly substituted for Passiflora edulis, which is used for the preparing juices. Another inadequate substitution occurs with Passiflora incarnata, wich is used in Europe, but does not adjust to the Brazilian climate. From adapting the methodologies described in the French, Helvetian and European Pharmacopoeia for the Passiflora incarnate species, a spectrophotometric method by UV-Visible has been developed to enable quantification of all flavonoids comprised in the leaves of both Passiflora edulis and Passiflora alata. The suggested procedure involved the complexation of the flavonoids with aluminum chloride, being rutin used as standard. Data obtained by the spectrophotometric method developed in the present work were compared with those obtained by HPLC. The French Pharmacopoeia methodology provided the most significant data in the study.
3

Estudo espectrofotométrico do sistema cobalto(II)/tiocianato e seu aproveitamento analítico / Spectrophotometric study of cobalt(II)/thiocyanate system and its analytical use

Sader, Ana Paula de Oliveira 09 December 2002 (has links)
Estudos sobre a formação dos complexos de metais, seus equilíbrios e, também, o aproveitamento analítico desses diferentes sistemas constituem uma tradicional linha de pesquisa em Química. Mais especificamente, as espécies formadas entre os vários pseudo-haletos e outros ligantes, com muitos cátions dos metais de transição, vêm sendo sistematicamente investigadas em nossos laboratórios de Química Analítica. Nesta linha, o emprego do íon tiocianato como ligante tem se destacado dentre os métodos analíticos para a determinação de cobalto, cuja procura tem sido crescente à medida que o homem, ao longo de sua evolução, descobre e produz novos materiais contendo esse metal. Desta forma, tendo em vista algumas características típicas do sistema Co(II)/SCN-, tal como sua intensa coloração, objetivou-se, nesta oportunidade, explorá-lo espectrofotometricamente com maior profundidade. Conseqüentemente, diversos parâmetros envolvidos na complexação dos íons cobalto (II) pelo tiocianato, tais como: a acidez do meio, a concentração disponível de ligante e a presença de solventes orgânicos no sistema, tiveram seus efeitos avaliados individualmente. Com os resultados destes estudos, estabeleceram-se as condições experimentais otimizadas para a montagem do método analítico, visando a determinação de íons cobalto(II). São elas: C (HClO4) =0,050 mol L-1 C (SCN-)=0,203 mol L-1 C(THF)=60% (v/v) Através de estudos espectrofotométricos preliminares, observou-se que o sistema apresenta dois máximos de absorção nestas condições experimentais: 316 e 622 nm, sendo esta última banda, aquela normalmente utilizada neste tipo de trabalho. Estudos de calibração nos dois comprimentos de onda indicaram que as leituras obedecem fielmente à lei de Beer em ambos os casos, porém com sensibilidade significativamente maior na região ultravioleta (E(316nm)= 1,20 x 104 e E(622nm)= 1,95 x 103 L mol-1 cm-1). Outros estudos sobre estabilidade, repetibilidade (precisão) e de possíveis interferentes também foram realizados, sendo os resultados bastante satisfatórios para fins analíticos. Observou-se interferência das espécies: I-, Al3+, IO3-, Mn2+, NO2-, BrO3-, S2O32-, Hg2+, Cd2+, quando presentes em concentrações cem vezes superiores à de cobalto(II). Entretanto, tal efeito desaparece quando estes íons acham-se em concentrações dez vezes maior do que a do metal de interesse. Aplicações analíticas do método proposto foram testadas em um produto farmacêutico (vitamina B12) e em uma liga odontológica, com resultados plenamente satisfatórios, já que os erros percentuais obtidos ficaram dentro da faixa aceitável (< 5%). A técnica de espectroscopia de absorção atômica foi utilizada paralelamente nestas análises, para efeito comparativo, na qual a determinação de cobalto mostrou-se possível na liga odontológica, mas inadequada para o fármaco (erro da ordem de 20%), nas condições de abertura realizadas. A comparação dos resultados mostra a potencialidade do método proposto, tendo em conta a simplicidade, exatidão e custo das aparelhagens. Finalizando, a possível influência do níquel (presente naturalmente em diversas amostras reais) na determinação de cobalto foi avaliada sob as condições experimentais estabelecidas para o método espectrofotométrico proposto. Observou-se que este “contaminante" natural exibe um pico de absorção em 245 nm e, através dos estudos, confirmou-se a aditividade das absorbâncias dos respectivos complexos (Co e Ni). Testou-se a possibilidade de determinação espectrofotométrica simultânea destes dois metais, através de leituras nos respectivos máximos (245 e 316 nm), empregando-se um sistema algébrico com duas equações simples, cujos resultados foram plenamente satisfatórios. As faixas úteis de trabalho, em termos de concentrações de cobalto e níquel foram, respectivamente: 0,94 a 4,04 mg L-1 e 28,7 a 123,7 mg L-1, respectivamente. / Studies about the formation of metallic complexes, their equilibria and also the analytical utilization of these different systems represent a traditional research line in Chemistry. More specifically, the species formed among the various pseudohalides and other ligands, with several cations of transition metals, have been systematically investigated in our Laboratories. The use of the thiocyanate ion as ligand has been intensive from among the analytical methods for cobalt(II) determination, of which interest has increased more recently, according to the man discovers and production of new materials containing this metal. Due some typical characteristics of the system Co(II)/SCN-, such as its colored complexes, the principal purpose of this study was to explore it more carefully by visible-ultraviolet spectrophotometry. Consequently, several parameters involved in the cobalt(II)/thiocyanate complexes formation, such as acidity level, concentration of free ligand, and the percentage of organic solvents in the system, had their respective effects evaluated individually. Through the results of these diverse studies, appropriate experimental conditions were established for the analytical methods, for the determination of the cobalt(II) ion. They are: C (HClO4)=0.050 mol L-1 C (SCN-)=0.203 mol L-1 C(THF)=60% (v/v) Preliminary spectrophotometry studies showed two absorption maxima (peaks) under these optimized experimental conditions: 316 and 622 nm, being this last visible band normally applied for this type of work (determination). Calibration studies at these two wavelengths showed that the Beer’s Law is obeyed in both cases, but a higher sensitivity was obtained in the ultraviolet region ( E(316nm)= 1.20 x 104 e E(622nm)= 1.95 x 103 L mol-1 cm-1). Other studies about stability, precision, accuracy and possible interferences were also performed, showing satisfactory results for the analytical purposes. It was observed some interference of the following species: I-, Al3+, IO3-, Mn2+, NO2-, BrO3-, S2O32-, Hg2+ and Cd2+, when present in concentrations one hundred times higher than the cobalt(II). However, this effect disappears when these ions are presented on concentration just ten times higher. Analytical applications of the proposed method were tested for a pharmaceutical product (B12 vitamin) and for an odontological alloy, with large success, since the percentage of error was within the tolerance range (<5%). Atomic absorption spectroscopy was also used in this analysis for comparision, in which the cobalt determination was possible for the alloy but inadequate for the pharmaceutical product (error about 20%). Comparison of the results shows the potentiality of this alternative spectrophotometric method, taking in account its simplicity, accuracy and equipments prices. Finally, the influence of nickel (naturally present in several real samples) on the spectrophotometric cobalt determination was evaluated, under the optimized experimental conditions. It was observed that this natural “contaminating" exhibits an absorption peak at 245 nm. Other confirmatory studies show the additivities of the respective absorbances (nickel and cobalt/thiocyanate complexes), allowing the simultaneous spectrophotometric determination of these these metals, using a matematical system with two equations (peaks 245 and 316 nm). This attempt was well satisfactory and the useful concentration ranges for cobalt and nickel were, respectively, 0.94 to 4.04 mg L-1 and 28.7 to 123.7 mg L-1.
4

Estudo espectrofotométrico do sistema cobalto(II)/tiocianato e seu aproveitamento analítico / Spectrophotometric study of cobalt(II)/thiocyanate system and its analytical use

Ana Paula de Oliveira Sader 09 December 2002 (has links)
Estudos sobre a formação dos complexos de metais, seus equilíbrios e, também, o aproveitamento analítico desses diferentes sistemas constituem uma tradicional linha de pesquisa em Química. Mais especificamente, as espécies formadas entre os vários pseudo-haletos e outros ligantes, com muitos cátions dos metais de transição, vêm sendo sistematicamente investigadas em nossos laboratórios de Química Analítica. Nesta linha, o emprego do íon tiocianato como ligante tem se destacado dentre os métodos analíticos para a determinação de cobalto, cuja procura tem sido crescente à medida que o homem, ao longo de sua evolução, descobre e produz novos materiais contendo esse metal. Desta forma, tendo em vista algumas características típicas do sistema Co(II)/SCN-, tal como sua intensa coloração, objetivou-se, nesta oportunidade, explorá-lo espectrofotometricamente com maior profundidade. Conseqüentemente, diversos parâmetros envolvidos na complexação dos íons cobalto (II) pelo tiocianato, tais como: a acidez do meio, a concentração disponível de ligante e a presença de solventes orgânicos no sistema, tiveram seus efeitos avaliados individualmente. Com os resultados destes estudos, estabeleceram-se as condições experimentais otimizadas para a montagem do método analítico, visando a determinação de íons cobalto(II). São elas: C (HClO4) =0,050 mol L-1 C (SCN-)=0,203 mol L-1 C(THF)=60% (v/v) Através de estudos espectrofotométricos preliminares, observou-se que o sistema apresenta dois máximos de absorção nestas condições experimentais: 316 e 622 nm, sendo esta última banda, aquela normalmente utilizada neste tipo de trabalho. Estudos de calibração nos dois comprimentos de onda indicaram que as leituras obedecem fielmente à lei de Beer em ambos os casos, porém com sensibilidade significativamente maior na região ultravioleta (E(316nm)= 1,20 x 104 e E(622nm)= 1,95 x 103 L mol-1 cm-1). Outros estudos sobre estabilidade, repetibilidade (precisão) e de possíveis interferentes também foram realizados, sendo os resultados bastante satisfatórios para fins analíticos. Observou-se interferência das espécies: I-, Al3+, IO3-, Mn2+, NO2-, BrO3-, S2O32-, Hg2+, Cd2+, quando presentes em concentrações cem vezes superiores à de cobalto(II). Entretanto, tal efeito desaparece quando estes íons acham-se em concentrações dez vezes maior do que a do metal de interesse. Aplicações analíticas do método proposto foram testadas em um produto farmacêutico (vitamina B12) e em uma liga odontológica, com resultados plenamente satisfatórios, já que os erros percentuais obtidos ficaram dentro da faixa aceitável (< 5%). A técnica de espectroscopia de absorção atômica foi utilizada paralelamente nestas análises, para efeito comparativo, na qual a determinação de cobalto mostrou-se possível na liga odontológica, mas inadequada para o fármaco (erro da ordem de 20%), nas condições de abertura realizadas. A comparação dos resultados mostra a potencialidade do método proposto, tendo em conta a simplicidade, exatidão e custo das aparelhagens. Finalizando, a possível influência do níquel (presente naturalmente em diversas amostras reais) na determinação de cobalto foi avaliada sob as condições experimentais estabelecidas para o método espectrofotométrico proposto. Observou-se que este “contaminante” natural exibe um pico de absorção em 245 nm e, através dos estudos, confirmou-se a aditividade das absorbâncias dos respectivos complexos (Co e Ni). Testou-se a possibilidade de determinação espectrofotométrica simultânea destes dois metais, através de leituras nos respectivos máximos (245 e 316 nm), empregando-se um sistema algébrico com duas equações simples, cujos resultados foram plenamente satisfatórios. As faixas úteis de trabalho, em termos de concentrações de cobalto e níquel foram, respectivamente: 0,94 a 4,04 mg L-1 e 28,7 a 123,7 mg L-1, respectivamente. / Studies about the formation of metallic complexes, their equilibria and also the analytical utilization of these different systems represent a traditional research line in Chemistry. More specifically, the species formed among the various pseudohalides and other ligands, with several cations of transition metals, have been systematically investigated in our Laboratories. The use of the thiocyanate ion as ligand has been intensive from among the analytical methods for cobalt(II) determination, of which interest has increased more recently, according to the man discovers and production of new materials containing this metal. Due some typical characteristics of the system Co(II)/SCN-, such as its colored complexes, the principal purpose of this study was to explore it more carefully by visible-ultraviolet spectrophotometry. Consequently, several parameters involved in the cobalt(II)/thiocyanate complexes formation, such as acidity level, concentration of free ligand, and the percentage of organic solvents in the system, had their respective effects evaluated individually. Through the results of these diverse studies, appropriate experimental conditions were established for the analytical methods, for the determination of the cobalt(II) ion. They are: C (HClO4)=0.050 mol L-1 C (SCN-)=0.203 mol L-1 C(THF)=60% (v/v) Preliminary spectrophotometry studies showed two absorption maxima (peaks) under these optimized experimental conditions: 316 and 622 nm, being this last visible band normally applied for this type of work (determination). Calibration studies at these two wavelengths showed that the Beer’s Law is obeyed in both cases, but a higher sensitivity was obtained in the ultraviolet region ( E(316nm)= 1.20 x 104 e E(622nm)= 1.95 x 103 L mol-1 cm-1). Other studies about stability, precision, accuracy and possible interferences were also performed, showing satisfactory results for the analytical purposes. It was observed some interference of the following species: I-, Al3+, IO3-, Mn2+, NO2-, BrO3-, S2O32-, Hg2+ and Cd2+, when present in concentrations one hundred times higher than the cobalt(II). However, this effect disappears when these ions are presented on concentration just ten times higher. Analytical applications of the proposed method were tested for a pharmaceutical product (B12 vitamin) and for an odontological alloy, with large success, since the percentage of error was within the tolerance range (<5%). Atomic absorption spectroscopy was also used in this analysis for comparision, in which the cobalt determination was possible for the alloy but inadequate for the pharmaceutical product (error about 20%). Comparison of the results shows the potentiality of this alternative spectrophotometric method, taking in account its simplicity, accuracy and equipments prices. Finally, the influence of nickel (naturally present in several real samples) on the spectrophotometric cobalt determination was evaluated, under the optimized experimental conditions. It was observed that this natural “contaminating” exhibits an absorption peak at 245 nm. Other confirmatory studies show the additivities of the respective absorbances (nickel and cobalt/thiocyanate complexes), allowing the simultaneous spectrophotometric determination of these these metals, using a matematical system with two equations (peaks 245 and 316 nm). This attempt was well satisfactory and the useful concentration ranges for cobalt and nickel were, respectively, 0.94 to 4.04 mg L-1 and 28.7 to 123.7 mg L-1.
5

Desenvolvimento de métodos espectrofotométricos de análise de flavonóides do \"maracujá\" (Passiflora alata e Passiflota edulis) / Development of a spectrophotometric method for the quantification of maracuja\'s flavonoids (Passiflora alata and Passiflora edulis)

Alessandra Cristina Soares Pozzi 09 March 2007 (has links)
\"Maracujá\" é o nome popular de várias espécies, dentre as quais Passiflora edulis e Passiflora alata (Passifloraceae). Esta última é uma planta medicinal amplamente utilizada no Brasil devido às suas propriedades ansiolíticas e sedativas, sendo também a espécie oficial da Farmacopéia Brasileira. Porém, freqüentemente ocorre a sua substituição indevida por Passiflora edulis, espécie usada para o preparo de sucos. Há também a confusão com a Passiflora incarnata, espécie usada na Europa, mas que não se adapta bem ao clima brasileiro. Neste trabalho foi desenvolvido um método espectrofotométrico por UV-visível para a quantificação dos flavonóides totais contidos nas folhas de Passiflora alata e de Passiflora edulis, a partir da adaptação das metodologias descritas nas Farmacopéias Francesa, Helvética e Européia para a espécie Passiflora incarnata. O procedimento proposto envolveu a complexação dos flavonóides com cloreto de alumínio e foi utilizada a rutina como padrão. Confrontou-se os dados obtidos pelo método espectrofotométrico desenvolvido neste trabalho com os obtidos por HPLC. Os melhores resultados foram obtidos com a metodologia adaptada da Farmacopéia Francesa. / \"Maracujá\" is the popular name of some species, among which are Passiflora edulis and Passiflora alata (Passifloraceae). The latter is a widely used medicinal plant in Brazil due to its ansiolytic and sedative properties, and also the official species of the Brazilian Pharmacopoeia. However, it is quite often improperly substituted for Passiflora edulis, which is used for the preparing juices. Another inadequate substitution occurs with Passiflora incarnata, wich is used in Europe, but does not adjust to the Brazilian climate. From adapting the methodologies described in the French, Helvetian and European Pharmacopoeia for the Passiflora incarnate species, a spectrophotometric method by UV-Visible has been developed to enable quantification of all flavonoids comprised in the leaves of both Passiflora edulis and Passiflora alata. The suggested procedure involved the complexation of the flavonoids with aluminum chloride, being rutin used as standard. Data obtained by the spectrophotometric method developed in the present work were compared with those obtained by HPLC. The French Pharmacopoeia methodology provided the most significant data in the study.
6

Hydrochemistry of natural waters from the river Darent catchment, Kent

Smith, A. C. S. January 1975 (has links)
No description available.
7

Estudo espectrofotométrico de oxidação no sistema Ferro(II)/Tiocianato e seu aproveitamento analítico. / Spectrophotometric study of oxidation in the Iron(II)/Thiocyanate system and some analytical applications.

Martins, Fernando Grine 19 July 2002 (has links)
Uma das linhas mais tradicionais de trabalho na área da Química é a de formação de complexos. Em nossos laboratórios tal, estudo é realizado de modo sistemático, geralmente envolvendo pseudo-haletos e haletos com cátions de metais de transição. As intensas colorações produzidas pela maioria das reações de complexação, entre um pseudo-haleto e um metal, têm sido bastante exploradas espectrofotometricamente para a determinação individual ou a especiação do respectivo metal. A forte cor vermelha característica de complexos formados entre o ferro e o tiocianato é uma das maiores evidências da analogia existente entre os ligantes tiocianato e azoteto (N3-). A pouca sensibilidade dos complexos formados no sistema Fe3+/SCN-, em meio aquoso, dificulta a aplicação de métodos clássicos fotométricos mais rigorosos. Estudos feitos em nossos laboratórios, em presença de alguns solventes e usando ferro-II, têm mostrado uma rápida oxidação do metal, seguida por imediata complexação, o que vêm possibilitando novas estratégias para se determinar o total de ferro em uma amostra, bem como a sua especiação. Objetivando dar continuidade a linha de pesquisa, que envolve o estudo da oxidação do ferro-II, vários parâmetros que afetam a velocidade de oxidação neste sistema reacional, assim como: acidez, concentração de ligante, temperatura e presença de solvente orgânico, foram cuidadosamente verificados. Reunindo as condições ideais necessárias para o estudo de complexação utilizando íons ferrosos, sendo elas: C H+ = 30 mmolL-1 C SCN- = 250 mmolL-1 CAcetona = 70 % (v/v) T = 25ºC &#955;máx = 480nm tempo de espera = 7 minutos Após a sondagem espectrofotométrica do sistema, foram realizados estudos de calibração, de estabilidade, de precisão e de possíveis interferentes. A curva analítica espectrofotométrica, para a determinação de ferro total, obedece à lei de Beer (r = 0,9993), mostrando a potencialidade de aproveitamento analítico desse sistema. O valor da absortividade molar média (e) determinado foi da ordem de 2,10.104 mol-1. L.cm-1. A faixa ideal de trabalho para a determinação de ferro é de 1 a 8 ppm. Comprovou-se uma boa precisão, bem como uma constância de leituras ótima para fins analíticos. Apenas as espécies NO2-, S2032-, C2042-, HPO42-, H2PO4-, Co2+ e Cu2+ mostraram interferência significativas (Er > 5 %) no método proposto. Concluindo a aplicação analítica do método, foi realizada determinação de ferro em produtos farmacêuticos e rochas naturais. Estudos comparativos dos resultados foram feitos utilizando também a absorção atômica como medidas paralelas. Na análise dessas amostras, o estudo comparativo entre a espectrofotometria e a absorção atômica apresentou resultados concordantes, não mostrando nenhuma interferência, visto que os erros percentuais obtidos acharem-se dentro do limite analítico comumente aceitável (< 5%). Os resultados obtidos mostraram a viabilidade e potencialidade do método espectrofotométrico proposto, como um método analítico alternativo para a determinação do ferro de maneira simples, precisa e exata. / One of the most traditional lines of work in the Chemistry is about the complex formation. In our laboratories this study is accomplished under a systematic way, principally involving pseudohalide and halide ligands with cations of transition metals. The intense color produced by the reactions among the pseudohalide ligands and metal have been so much explored by spectrophotometic analises. The strong red color characteristic of compounds formed between iron(III) and thiocyanate ions is one of the largest evidences of the analogy existent between the thiocyanate and azide(N3-) ligands. Studies done in our laboratories in the presence of some solvents and using iron-II ion have showed a fast oxidation of this metal followed by immediate reaction between the pseudohalide ligand and the metal. The possibilities of new methods for determination of the total amount of iron in a sample, as well as its speciation, have been analysed. During the study of the oxidation of the iron-II, several parameters that affect the oxidation speed in this system like: acidity, ligands concentration, temperature and presence of organic solvent, were verified carefully. This way, the recommended experimental conditions for a rapid oxidation and utilizing this system (determination of total iron) are: C H+= 30 mmolL-1 C SCN-= 250 mmolL-1 CAcetone = 70 % (v/v) T = 25ºC &#955;máx = 480nm waiting time = 7 minutes Calibration, stability, precision and diverse ions effect studies could be done using absorbances values for the ferric complexes that are measured at 480 nm. The analytical curve for the total iron determination, obeys the Beer law (r = 0,9993), showing potentiality for the analytical use of this system. The value of the average molar absortivity is 2,10.104 mol-1.L.cm-1. The ideal range of work for the determination of iron is from 1 to 8 ppm. A good precision was verified by suitable studies. About diverse ion effects, just the species NO2-, S2032-, C2042-, HPO42-, H2PO4-, Co2+ and Cu2+ showed some interference on determination in the proposed method. Concluding the analytical application of present method, determination of iron was tested in pharmaceutical product and natural rocks. Comparative studies of the results were made also using the atomic absorption as parallel measures. In these analysis samples, the comparative study between the spectrophotometric and atomic absorption presented concordant results, not evidencing significant interferences (errors commonly acceptable, <5%). The obtained results showed the viability and potentiality of the proposed method, as an alternative analytical manner for the determination of the metal with precision and exactness.
8

Interação de Íons de manganês, em diferentes estados de oxidação, com íon azoteto / On the interaction between azide and manganese ions at several oxidation states

Moya, Horacio Dorigan 19 June 1998 (has links)
Realizaram-se estudos potenciométricos, em combinação com medições espectrofotométricas, para caracterizar a espécie de íon manganês obtida a partir de oxidação coulométrica a corrente constante utilizando-se solução de Mn(II) (0,050 mol.L-1) em N3- (0,50 a 2,0 mol.L-1) e H+ (0,01 mol.L-1). Graficamente foi possível concluir que a espécie gerada é Mn(III) e obter os valores dos potenciais condicionais de redução, E0\'x, do par Mn(III)/Mn(II), em soluções tampão N3-/HN3, de concentração de N3- 0,50; 1,0; 1,5; 2,0 e 4,0 mol.L-1 e H+ 0,010 mol.L-1, sendo 0,468, 0,421, 0,396, 0,377 e 0,336 V (vs. ECS), respectivamente. Esses valores de E0\'x permitiram o cálculo das constantes de equilíbrio para os complexos no sistema Mn(III)/N3-, sendo: &#946;1 = 1,23.105 M-1, &#946;2 = 6,03.108 M-2, &#946;3 = 2,37.1011 M-3, &#946;4 = 1,54.1011 M-4 e &#946;5 = 9,57.1011 M-5 (T = 25,0 &#177; 0,1 &#186;C, I = 2,0 mol.L-1 com NaClO4). Os valores calculados para as absortividades molares, em 430 nm, para as espécies [Mn(N3)3], [Mn(N3)4]- e [Mn(N3)5]2- foram 226, 3.680 e 6560 mol-1.L.cm-1, respectivamente. Para o estudo do cátion Co(II), foram efetuadas oxidações coulométricas da mesma forma e nas mesmas condições que para o cátion Mn(II). Os valores de E0\'x encontrados para o par Co(III)/Co(II) foram 0,400, 0,338, 0,302, 0,277 e 0,228 V (vs. ECS), para as concentrações de N3- 0,50; 1,0; 1,5; 2,0 e 4,0 mol.L-1 e H+ 0,010 mol.L-1. Com os valores de E0\'x obtidos para os pares Co(III)/Co(II) e Mn(III)/Mn(II), calcularam-se as constante de equilíbrio global, K, para a reação redox entre [Co(N3)n]3-n e [Mn(N3)n]2-n, encontrando-se os valores 7,1xl0-2, 4,0x10-2, 2,6x10-2, 2,0x10-2 e l,5x10-2, para os tampões acima descritos, respectivamente. Outros estudos revelaram a possível formação da espécies Mn(VI) quando KMnO4 e K2MnO4 são adicionados, separadamente, a uma solução tampão azoteto, por exemplo, N3- = 1,5 mol.L-1 e HN3 = 0,05 mol.L-1. / Spectrophotometric studies combined with coulometric generation of Mn(III), in presence of large excess of Mn(II), showed a maximum absorbance peak at 430 nm. The average molar absorptivity increases with azide concentration (0.44 to 3.9 mol.L-1) from 3,100 to 6,300 mol-1.L.cm-1, showing a stepwise complex formation. Potential measurements of the Mn(III)/Mn(II) system in several azide aqueous buffers solutions: 1.0x10-2 mol.L-1 HN3, (0.50 to 2.0 mol.L-1) N3- and 5.0x10-1 mol.L-1 Mn(II) and constant ionic strength 2.0 mol.L-1, kept with sodium perchlorate, leads to the conditional potential, E0\'x, in several azide concentrations at 25.0 &#177; 0.1 &#186;C (0.468, 0.421, 0.396, 0.377 e 0.336 V (vs. SCE) for the 0.50; 1.0; 1.5; 2.0 and 4.0 mol.L-1 N3- concentration, respectively). Considering the overall formation constants of Mn(II)/N3-, from former studies, and the potential, E0\'s = 1.063 V vs. SCE, for Mn(III)/Mn(II) system in non-complexing medium, it was possible to calculate the Fronaeus function, F0(L), and the following overall formation constants: &#946;1 = 1.2x105 M-1, &#946;2 = 6.0x108 M-2, &#946;3 = (2.4&#177;0.7)x1011 M-3, &#946;4 = (1.5&#177;0.5)x1011 M-4 and &#946;5 = (9.6&#177;.0.8)x1011 M-5 for the Mn(III)/N3- complexes. The molar absorptivity values, at 430 nm, found for the species [Mn(N3)3], [Mn(N3)4]- and [Mn(N3)5]2- were 226, 3,680 and 6,560 mol-1.L.cm-1, respectively. Similar studies with Co(II) in the same conditions, lead to the following conditional potentials, E0\'x, for the Co(III)/Co(II) system: 0.400, 0.338, 0.302, 0.277 e 0.228 V (vs. SCE). Using the E0\'x values obtained for both systems, Co(III)/Co(II) and Mn(III)/Mn(II), it was possible to calculate the equilibrium constant for the redox reaction between [Co(N3)n]3-n and [Mn(N3)n]2-n. The values found were 7.1xl0-2, 4.0x10-2, 2.6x10-2, 2.0x10-2 and 1.5x10-2, for 0.50; 1.0; 1.5; 2.0 and 4.0 mol.L-1 N3- concentration, respectively, in the same acidity (1.0x10-2 mol.L-1 HN3).
9

Standardization and Application of Spectrophotometric Method for Reductive Capacity Measurement of Nanomaterials

Hwang, Wonjoong 2010 August 1900 (has links)
In this study, a reproducible spectrophotometric method was established and applied to measure reductive capacity of various nanomaterials. Reductive capacity had been implicated in the toxicity of nanomaterials, but a standardized measurement method had been lacking until this work. The reductive capacity of nanoparticles was defined as the mass of iron reduced from Fe3 to Fe2 by unit mass of nanoparticles, in an aqueous solution that initially contained ferric ions. To measure the reductive capacity, the nanomaterials were incubated in a ferric aqueous solution for 16 hours at 37 degrees C, and the reductive capacity of the nanoparticles was determined by measuring the amount of Fe3 reduced to Fe2 using a spectrophotometric method. The reagents 1,10-phenanthroline and hydroquinone were used as a Fe2 indicator and a reducing agent respectively for the assay. To standardize this method, various experiments were carried out. For the initial ferric solution, various Fe salts were tested, and Iron(III) sulfate was chosen as Fe salt for the standard method. The measured reductive capacity of nanoparticles was found to vary with the measurement conditions; the measured reductive capacity increased with increasing the Fe/nanoparticle ratio; the measured reductive capacity increased with incubation time and leveled off after 8 hours of incubation. For hydrophobic materials, the surfactant Tween-20 was added so that the particles could be wetted and suspended in the ferric aqueous solution. After incubation, the particles were removed from the solution by either filtration or centrifugation before applying the spectrophotometric method. In addition, optimal pH and minimum time to reach ultimate color intensity were also found. Carbon-based nanomaterials, standard reference material and metal oxides were measured for their reductive capacities with this method and characterized by transmission electron microscopy (TEM), energy dispersive x-ray spectroscopy (EDS), x-ray diffraction (XRD), BET measurement and Raman spectroscopy. For some nanoparticles, the reductive capacity was measured for both the pristine form and the form treated by oxidization or grinding. All carbon-based nanomaterials, except for pristine C60, have a significant reductive capacity while reductive capacity of metal oxides is very low. And it was found that reductive capacity can be increased by surface functional groups or structural defects and reduced by oxidization or heating (graphitization). The reductive capacity of a material can play an important role in its toxicology by synergistic toxic effects in the presence of transition metal ions through the Fenton reaction. Moreover, even without transition metal ions, the ability of a material to donate electrons can be involved in toxicity mechanisms via generation of reactive oxygen species.
10

Estudo espectrofotométrico de oxidação no sistema Ferro(II)/Tiocianato e seu aproveitamento analítico. / Spectrophotometric study of oxidation in the Iron(II)/Thiocyanate system and some analytical applications.

Fernando Grine Martins 19 July 2002 (has links)
Uma das linhas mais tradicionais de trabalho na área da Química é a de formação de complexos. Em nossos laboratórios tal, estudo é realizado de modo sistemático, geralmente envolvendo pseudo-haletos e haletos com cátions de metais de transição. As intensas colorações produzidas pela maioria das reações de complexação, entre um pseudo-haleto e um metal, têm sido bastante exploradas espectrofotometricamente para a determinação individual ou a especiação do respectivo metal. A forte cor vermelha característica de complexos formados entre o ferro e o tiocianato é uma das maiores evidências da analogia existente entre os ligantes tiocianato e azoteto (N3-). A pouca sensibilidade dos complexos formados no sistema Fe3+/SCN-, em meio aquoso, dificulta a aplicação de métodos clássicos fotométricos mais rigorosos. Estudos feitos em nossos laboratórios, em presença de alguns solventes e usando ferro-II, têm mostrado uma rápida oxidação do metal, seguida por imediata complexação, o que vêm possibilitando novas estratégias para se determinar o total de ferro em uma amostra, bem como a sua especiação. Objetivando dar continuidade a linha de pesquisa, que envolve o estudo da oxidação do ferro-II, vários parâmetros que afetam a velocidade de oxidação neste sistema reacional, assim como: acidez, concentração de ligante, temperatura e presença de solvente orgânico, foram cuidadosamente verificados. Reunindo as condições ideais necessárias para o estudo de complexação utilizando íons ferrosos, sendo elas: C H+ = 30 mmolL-1 C SCN- = 250 mmolL-1 CAcetona = 70 % (v/v) T = 25ºC &#955;máx = 480nm tempo de espera = 7 minutos Após a sondagem espectrofotométrica do sistema, foram realizados estudos de calibração, de estabilidade, de precisão e de possíveis interferentes. A curva analítica espectrofotométrica, para a determinação de ferro total, obedece à lei de Beer (r = 0,9993), mostrando a potencialidade de aproveitamento analítico desse sistema. O valor da absortividade molar média (e) determinado foi da ordem de 2,10.104 mol-1. L.cm-1. A faixa ideal de trabalho para a determinação de ferro é de 1 a 8 ppm. Comprovou-se uma boa precisão, bem como uma constância de leituras ótima para fins analíticos. Apenas as espécies NO2-, S2032-, C2042-, HPO42-, H2PO4-, Co2+ e Cu2+ mostraram interferência significativas (Er > 5 %) no método proposto. Concluindo a aplicação analítica do método, foi realizada determinação de ferro em produtos farmacêuticos e rochas naturais. Estudos comparativos dos resultados foram feitos utilizando também a absorção atômica como medidas paralelas. Na análise dessas amostras, o estudo comparativo entre a espectrofotometria e a absorção atômica apresentou resultados concordantes, não mostrando nenhuma interferência, visto que os erros percentuais obtidos acharem-se dentro do limite analítico comumente aceitável (< 5%). Os resultados obtidos mostraram a viabilidade e potencialidade do método espectrofotométrico proposto, como um método analítico alternativo para a determinação do ferro de maneira simples, precisa e exata. / One of the most traditional lines of work in the Chemistry is about the complex formation. In our laboratories this study is accomplished under a systematic way, principally involving pseudohalide and halide ligands with cations of transition metals. The intense color produced by the reactions among the pseudohalide ligands and metal have been so much explored by spectrophotometic analises. The strong red color characteristic of compounds formed between iron(III) and thiocyanate ions is one of the largest evidences of the analogy existent between the thiocyanate and azide(N3-) ligands. Studies done in our laboratories in the presence of some solvents and using iron-II ion have showed a fast oxidation of this metal followed by immediate reaction between the pseudohalide ligand and the metal. The possibilities of new methods for determination of the total amount of iron in a sample, as well as its speciation, have been analysed. During the study of the oxidation of the iron-II, several parameters that affect the oxidation speed in this system like: acidity, ligands concentration, temperature and presence of organic solvent, were verified carefully. This way, the recommended experimental conditions for a rapid oxidation and utilizing this system (determination of total iron) are: C H+= 30 mmolL-1 C SCN-= 250 mmolL-1 CAcetone = 70 % (v/v) T = 25ºC &#955;máx = 480nm waiting time = 7 minutes Calibration, stability, precision and diverse ions effect studies could be done using absorbances values for the ferric complexes that are measured at 480 nm. The analytical curve for the total iron determination, obeys the Beer law (r = 0,9993), showing potentiality for the analytical use of this system. The value of the average molar absortivity is 2,10.104 mol-1.L.cm-1. The ideal range of work for the determination of iron is from 1 to 8 ppm. A good precision was verified by suitable studies. About diverse ion effects, just the species NO2-, S2032-, C2042-, HPO42-, H2PO4-, Co2+ and Cu2+ showed some interference on determination in the proposed method. Concluding the analytical application of present method, determination of iron was tested in pharmaceutical product and natural rocks. Comparative studies of the results were made also using the atomic absorption as parallel measures. In these analysis samples, the comparative study between the spectrophotometric and atomic absorption presented concordant results, not evidencing significant interferences (errors commonly acceptable, <5%). The obtained results showed the viability and potentiality of the proposed method, as an alternative analytical manner for the determination of the metal with precision and exactness.

Page generated in 0.0898 seconds