• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • 1
  • Tagged with
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Advances in spatially encoded single-scan magnetic resonance imaging / Avancées de l'imagerie par résonance magnétique à encodage spatiotemporel

Marhabaie, Sina 12 December 2017 (has links)
Il y a plus de soixante-dix ans que la résonance magnétique nucléaire (RMN) a été découverte, mais elle est toujours prospère et vivante, couvrant un large éventail d'applications dans les sciences, technologies et industries. Une application omniprésente de la résonance magnétique nucléaire est une technique d'imagerie appelée imagerie par résonance magnétique (IRM), qui a trouvé beaucoup d'applications en médecine, sciences, et technologie. Les techniques de transformation de Fourier dites par ''encodage dans l’espace k'' sont des méthodes d'IRM basées sur l'acquisition d'un signal de résonance magnétique en fonction d’un paramètre "k" qui sera ensuite transformé en une image par transformation de Fourier. Aujourd'hui, les techniques de Fourier sont les plus importantes en IRM, mais il existe des alternatives parmi lesquelles ''l'encodage spatial'', qui est le sujet principal de cette thèse. Dans l’encodage spatial (également connu sous le terme d’encodage temporel ou encodage spatiotemporel), l'acquisition du signal s'effectue de telle manière que l'intensité du signal ressemble à l'objet. Par conséquent, dans l'encodage spatial, la transformation de Fourier n'est pas nécessaire pour la reconstruction de l'image.Il a été montré que les techniques d'imagerie hybride à balayage unique, qui utilisent l'encodage k traditionnel dans une direction et l'encodage spatiotemporel dans l'autre, sont supérieures aux méthodes traditionnelles qui utilisent l'encodage k dans les deux directions, notamment pour supprimer les effets de variations de fréquence (causées par des champs magnétique inhomogènes, ou par la présence de plusieurs déplacements chimiques, ou toute autre source de variations de fréquence), et conduisent à des images beaucoup moins déformées que les méthodes d'imagerie traditionnelles. Dans cette thèse, l'idée de l'imagerie par résonance magnétique par encodage spatial sera discutée. La formation de l'image et les propriétés des images résultant de différentes séquences d'encodage spatial seront brièvement étudiées.Les effets de la diffusion sur une séquence hybride établie appelée "acquisition rapide par excitation séquentielle et refocalisation" (RASER) sont étudiés. On montrera que dans les séquences d'encodage spatial, l'atténuation du signal due à la diffusion n'est souvent pas uniforme sur l’ensemble de l'objet, provoquant un contraste trompeur dans l'image. Afin d'éliminer ce faux contraste, une séquence d'impulsion comprenant deux impulsions balayées en fréquence (DC-RASER) est proposée. Les résultats expérimentaux sont conformes à nos prévisions théoriques sur les effets de la diffusion dans ces séquences. Ils confirment que l'atténuation du signal due à la diffusion est uniforme sur l’ensemble de l’objet.Afin de développer les applications de l'encodage spatial à balayage unique, nous montrons comment on peut améliorer le contraste dans la séquence originale RASER. En changeant le déroulement de la séquence d'impulsions, nous avons réalisé une variante de RASER appelée RASER avec écho décalé (ES-RASER), qui fournit un niveau de contraste réglable.Enfin, nous montrons comment on peut améliorer quelques aspects des séquences à encodage temporel disponibles. En réarrangeant les gradients positifs et négatifs, nous montrons comment on peut réduire la vitesse de la commutation des gradients. Ceci est important, car une commutation rapide des gradients n'est pas toujours techniquement possible et peut en plus stimuler involontairement le système nerveux du patient. En utilisant un gradient supplémentaire, nous avons pu modifier l'ordre de détection dans la séquence originale d’encodage temporel. Cela conduit à un temps d'écho identique pour tous les échos, et à une atténuation uniforme du signal due à la relaxation. Finalement, nous montrons comment on peut répartir l’acquisition des séquences d'encodage temporel de façon entrelacée, afin de réduire l'atténuation du signal due à la diffusion. / Although Nuclear Magnetic Resonance (NMR) has been discovered more than seventy years ago, it is still thriving and alive, covering a broad spectrum of applications in science, technology and industry. One of the most ubiquitous applications of Nuclear Magnetic Resonance is an imaging technique dubbed Magnetic Resonance Imaging (MRI), which has found many applications in science, technology, and particularly in medicine. Fourier or k-encoding techniques are MRI methods based on acquiring a magnetic resonance signal as a function of the parameter “k”, a subsequent Fourier transform then will convert the signal to an image. Although nowadays Fourier techniques are prominent in MRI, there are other alternatives, among which spatial encoding, the main subject of this dissertation, should be mentioned. In spatial encoding (also known as time- or spatiotemporal-encoding), signal acquisition is performed in such a way that the signal intensity itself resembles the object. Consequently, in spatial encoding there is no need for a Fourier transform for image reconstruction.Single-scan hybrid imaging techniques that use traditional k-encoding in one direction, and spatial (time-)encoding in the other have been shown to be superior to traditional full k-encoding methods (that use k-encoding in both directions) in suppressing the effects of frequency variations (caused by inhomogeneous magnetic fields, the presence of more than one chemical shift, or any other frequency variation) and lead to images that are much less distorted than traditional single-scan imaging methods. In this dissertation the main idea behind spatial encoding magnetic resonance imaging will be introduced. Image formation and image properties in different spatial encoding sequences will also be briefly investigated.Then, the effects of diffusion on an established hybrid sequence called “Rapid Acquisition by Sequential Excitation and Refocusing, RASER” are investigated. It will be shown that in spatial encoding sequences, the attenuation of the signal due to diffusion is often not uniform across the entire object, leading to misleading contrast in the image. In order to eliminate this misleading contrast, a double-chirp RASER (DC-RASER) pulse sequence is proposed in this work. The experimental results are in accordance with our theoretical investigations about the effects of diffusion in these sequences. They also confirm that the signal attenuation due to diffusion is uniform, as expected theoretically for DC-RASER.In order to develop applications of single-scan spatial encoding MRI we show how one can enhance the contrast in the original RASER sequence. By changing the timing of the pulse sequence, we achieved a variant of RASER called Echo-Shifted RASER (ES-RASER), which provides a tunable contrast level.Finally, we show how one can improve a few aspects of the available time-encoding sequences. By rearranging positive and negative gradients we show how one can reduce the switching rate of the gradients. This is important because fast gradient switching is not always technically feasible; in addition, it may unwittingly stimulate the patient’s nervous system. By using an additional gradient we can change the detection order in the original time-encoding sequence. This leads to an identical echo-time for all echoes, and hence a uniform signal attenuation due to relaxation. Furthermore, we show how one can implement time-encoding sequences in an interleaved fashion in order to reduce signal attenuation due to diffusion.
2

Anordning för rengöring avkomponent i mjölkningsrobot : Framtagning av lösning för förbättrad rengöring avspentvättkopp för att motverka bakterietillväxt / Device for cleaning of component in milking robot : Design of solution for improved cleaning of teat cleaningcup to prevent bacterial growth

Lindbom, Erik January 2017 (has links)
This report describes how to make the VMS teat cleaning cup clean itself properly.The purpose is to create a sulotion that make sure the whole cup gets washedduring normal cleaning. The solution should be compatible with earlier versionsof the VMS and will be tested to see if the amount of bacteria decreases. / Denna rapport behandlar problemet med att en ny version av spentvättkopp på både dagens och framtida VMS (Volontary milking system) inte görs rent ordentligt. Syftet med projektet var att ta fram en lösning som låter hela spentvättkoppen göras rent när den inte används. Den färdiga versionen ska kunna testas ingående i en verklig miljo på olika generationer av VMS:er. Syftet med detär att kontrollera att lösningen klarar av långvarigt bruk och att göra en jämförelse för att se om mängden bakterier minskar. Ytterligare ett syfte var att göra prototypen lätt att montera utan att behöva modiera den existerande maskinen. Resultatet blev tre varianter på grund av olika designval på tidigare versioner.
3

La régulation des cellules souches adultes intestinales de drosophila melanogaster : Comment SPEN influence un destin cellulaire / Intestinal stem cell regulation in Drosophila melanogaster : how does SPEN control their fate ?

Andriatsilavo Rakoto, Mahéva 29 September 2015 (has links)
Les cellules souches adultes sont des cellules non différenciées, essentielles au le renouvellement constant de nos tissus. Elles produisent des cellules différenciées nécessaires au fonctionnement de nos organes, tout en maintenant un réservoir de cellules souches dans le tissu. Cet équilibre entre prolifération et différentiation cellulaire est crucial pour le maintien d’un état constant du tissu appelé homéostasie tissulaire. Entre identité « souche » et différenciation : Quels programmes génétiques contrôlent ces états ? Cette question suscite un intérêt majeur tant pour la recherche dans le domaine des cellules souches que pour les perspectives thérapeutiques qui en découlent. Dans cette optique, ce travail de thèse a permis de mettre en évidence un nouveau rôle du gène spen dans le contrôle des cellules souches intestinales chez Drosophila melanogaster. Une inactivation du gène spen est à l’origine d’une accumulation aberrante des cellules souches au sein de l’intestin de drosophile. La mise en place d’un protocole de purification par FACS des cellules souches, associé à un séquençage à grande échelle des ARN, a permis de mettre à jour les réseaux de gènes régulés par Spen dans les cellules souches. Ainsi, en combinant des techniques de génétique et d’analyses in vivo, ce travail montre que Spen est un facteur clé du processus de spécification des cellules souches intestinales et de la régulation de leur prolifération. Cette étude participe ainsi à la compréhension de la fonction moléculaire des protéines de la famille SPEN dans les cellules souches et les dérégulations à l’origine des pathologies auxquelles elles sont associées. / Adult stem cells are non-differentiated cells that maintain tissue homeostasis by supplying differentiated cells while at the same time self-renewing. How is this balance between stem cell state and differentiated state controlled? This question became one of the major interests of the Stem cell research and Translation, mostly due to the potential therapeutic perspectives that it gives. Regarding this effort, this thesis work describes a new function of a gene call split-ends/spen in adult stem cell regulation in Drosophila intestine. SPEN familly is composed by essential genes, which codes conserved proteins from Plants to Metazoa. They are involved in key cellular processes such as cell death, differentiation or proliferation, and are associated with various molecular functions controlling transcriptional and post-transcriptional gene expression. We found that a spen inactivation in Drosophila intestine leads to an abnormal increase in adult stem cells. In this work, by combining genetics tools and in vivo stem cell analysis methods, we could show that Spen works as a key factor of intestinal stem cell commitment and plays a role in their proliferation control. How does genetics programs control cellular identity? In order to investigate the molecular signature of intestinal stem cells and progenitor cells knockdowned for spen, we combined genetics, cell sorting and mRNA sequencing analysis to uncovered Spen target genes regulated in intestinal stem cells. Here, we provide a new function of spen in adult stem cell regulation, which may also shed light on its mode of action in other developmental and pathological contexts.

Page generated in 0.0434 seconds