Spelling suggestions: "subject:"standstill bfrequency desponse"" "subject:"standstill bfrequency coresponse""
1 |
Use of synchronizing tests and quasilinearization in the identification of synchronous machine parametersEcheverria, Wladimir January 1981 (has links)
No description available.
|
2 |
MODELING AND VALIDATION OF A SYNCHRONOUS-MACHINE/CONTROLLED-RECTIFIER SYSTEMHord, Kyle A 01 January 2014 (has links)
The hardware validation of a novel average-value model (AVM) for the simulation of a synchronous-generator/controlled rectifier system is presented herein. The generator is characterized using genetic algorithm techniques to fit standstill frequency response (SSFR) measurements to q and d-axis equivalent circuits representing the generator in the rotor reference frame. The generator parameters form the basis of a detailed model of the system, from which algebraic functions defining the parametric AVM are derived. The average-value model is compared to the physical system for a variety of loading and operating conditions including step load change, change in delay angle, and external closed-loop control, validating the model accuracy for steady-state and transient operation.
|
3 |
Hydropower generator and power system interactionBladh, Johan January 2012 (has links)
After decades of routine operation, the hydropower industry faces new challenges. Large-scale integration of other renewable sources of generation in the power system accentuates the role of hydropower as a regulating resource. At the same time, an extensive reinvestment programme has commenced where many old components and apparatus are being refurbished or replaced. Introduction of new technical solutions in existing power plants requires good systems knowledge and careful consideration. Important tools for research, development and analysis are suitable mathematical models, numerical simulation methods and laboratory equipment. This doctoral thesis is devoted to studies of the electromechanical interaction between hydropower units and the power system. The work encompasses development of mathematical models, empirical methods for system identification, as well as numerical and experimental studies of hydropower generator and power system interaction. Two generator modelling approaches are explored: one based on electromagnetic field theory and the finite element method, and one based on equivalent electric circuits. The finite element model is adapted for single-machine infinite-bus simulations by the addition of a network equivalent, a mechanical equation and a voltage regulator. Transient simulations using both finite element and equivalent circuit models indicate that the finite element model typically overestimates the synchronising and damping properties of the machine. Identification of model parameters is performed both numerically and experimentally. A complete set of equivalent circuit parameters is identified through finite element simulation of standard empirical test methods. Another machine model is identified experimentally through frequency response analysis. An extension to the well-known standstill frequency response (SSFR) test is explored, which involves measurement and analysis of damper winding quantities. The test is found to produce models that are suitable for transient power system analysis. Both experimental and numerical studies show that low resistance of the damper winding interpole connections are vital to achieve high attenuation of rotor angle oscillations. Hydropower generator and power system interaction is also studied experimentally during a full-scale startup test of the Nordic power system, where multiple synchronised data acquisition devices are used for measurement of both electrical and mechanical quantities. Observation of a subsynchronous power oscillation leads to an investigation of the torsional stability of hydropower units. In accordance with previous studies, hydropower units are found to be mechanically resilient to subsynchronous power oscillations. However, like any other generating unit, they are dependent on sufficient electrical and mechanical damping. Two experimentally obtained hydraulic damping coefficients for a large Francis turbine runner are presented in the thesis.
|
Page generated in 0.0519 seconds