• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Determinação eletroanalítica e cromatográfica de Metilparabeno. Uma comparação estatística / Electroanalytical and chromatographic determination of Methylparaben. A statistical comparison

Mendonça, Camila Domingues 31 July 2015 (has links)
A cromatografia a líquido de alta eficiência e a voltametria de onda quadrada foram estudadas e comparadas estatisticamente para a detecção do contaminante emergente metilparabeno (MePa). Os parabenos vêm sendo amplamente utilizados como conservantes em cosméticos, alimentos e remédios. É crescente o número de estudos que visam à detecção dos parabenos em virtude dos males causados à saúde humana, devido às suas características de serem carcinogênicos e interferentes endócrinos. Para determinação cromatográfica, foi desenvolvido um método analítico que utilizou filtração à vácuo seguida de análise cromatográfica acoplada a um detector UV. O eletrodo de diamante dopado com boro (BDD) foi utilizado para determinação eletroanalítica de MePa pela técnica voltamétrica. Para a análise cromatográfica, foi observada boa linearidade (0,999) na faixa de 0,5 a 30 mgL-1, com limite de detecção e quantificação de 0,49 mgL-1 e 0,73 mgL-1, respectivamente, para amostra de água natural superficial e para a amostra de cosmético 1,26 mgL-1 e 1,88 mgL-1, respectivamente. A dependência da corrente pelo pH e os parâmetros eletroquímicos (frequência, amplitude e step) foram estudados para obtenção de condições experimentais ótimas na determinação de MePa. Foi observado que o eletrólito suporte ideal é o tampão PBS 0,1 molL-1 (pH 7,5). Linearidade adequada (0,998), na mesma faixa de trabalho, com limite de detecção e quantificação de 0,43 mgL-1 e 1,44 mgL-1, respectivamente, foram encontrados para a técnica voltamétrica. Os métodos utilizados em ambas as técnicas foram validados em uma amostra de água natural superficial, coletada em região pouco impactada, e em uma amostra de cosmético. Utilizando o método cromatográfico, foram obtidos intervalos de recuperação entre 95,6% e 101,6% com RSD inferior a 4,8% (n = 3) e entre 78,0% e 99,8% com RSD inferior a 2,2% (n = 3) para amostras de água natural superficial e de cosmético, respectivamente. Na determinação eletroanalítica, soluções fortificadas daquelas amostras mostraram intervalo de recuperação entre 92,6% e 106,4%, com um desvio-padrão relativo (RSD) inferior a 9,76% (n = 3), para amostra de água superficial natural, e entre 90,0% e 112,6% com RSD inferior a 7,4% (n = 3), para amostra de cosmético. Os resultados das detecções cromatográfica e eletroanalítica foram comparados e analisados estatisticamente segundo o método de Miller e Miller. Através do teste t de Student pareado, demonstrou-se que a metodologia eletroanalítica é capaz de determinar MePa com boa precisão tal como a técnica padrão de detecção, a cromatografia, na faixa de trabalho de 1,0 a 30 mgL-1. / The high performance liquid chromatography and square wave voltammetry have been studied and compared statistically to detect the emerging contaminant methylparaben (MePa). Parabens have been widely used as preservatives in cosmetics, food and drugs. It is increasing the number of studies that aimed the detection of parabens because of its possible hazardous effect in the human health, as probably being carcinogenics and endocrine disruptors. For chromatographic determination, an analytical method that used vacuum filtration followed by chromatographic analysis coupled to a UV detector was developed. The boron doped diamond electrode (BDD) was used to electroanalytical determination to MePa by voltammetric technique. The chromatographic analysis showed good linearity (0.999) in the range from 0.5 to 30 mgL-1, with detection and quantification limit of 0.49 mgL-1 and 0.73 mgL-1, respectively, for natural surface water sample and to the cosmetic sample 1.26 mgL-1 and 1.88 mgL-1, respectively. The dependence of the current to pH and electrochemical parameters (frequency, amplitude and step) were studied to obtain the optimal experimental conditions in determining MePa. It has been observed that the ideal supporting electrolyte is PBS 0.1 molL-1 (pH 7.5). Adequate linearity (0.998), in the same working range, with detection and quantification limit of 0.43 mgL-1 and 1.44 mgL-1, respectively, were found for the voltammetric technique. The methods used in both techniques were validated in a sample of natural surface water, collected in little impacted region, and a cosmetic sample. Using the chromatographic method were obtained recovery intervals between 95.6% and 101.6% with RSD less than 4.8% (n = 3) and between 78.0% and 99.8% with RSD less than 2.2% (n = 3) for samples of natural surface water and cosmetic, respectively. In electroanalytic determination, fortified solutions of those samples showed a recovery range between 92.6% and 106.4% with a relative standard deviation (RSD) less than 9.76% (n = 3) for natural surface water sample and between 90.0% and 112.6% with RSD less than 7.4% (n = 3), for cosmetic sample. The results of chromatographic and electroanalytical detections were compared and statistically analyzed by the Miller and Miller\'s method. Using the Student\'s paired t-test, it was demonstrated that electroanalytical methodology is able to determine MePa with good accuracy as standard detection technique, chromatography, on working range of 1.0 to 30 mgL-1.
2

Determinação eletroanalítica e cromatográfica de Metilparabeno. Uma comparação estatística / Electroanalytical and chromatographic determination of Methylparaben. A statistical comparison

Camila Domingues Mendonça 31 July 2015 (has links)
A cromatografia a líquido de alta eficiência e a voltametria de onda quadrada foram estudadas e comparadas estatisticamente para a detecção do contaminante emergente metilparabeno (MePa). Os parabenos vêm sendo amplamente utilizados como conservantes em cosméticos, alimentos e remédios. É crescente o número de estudos que visam à detecção dos parabenos em virtude dos males causados à saúde humana, devido às suas características de serem carcinogênicos e interferentes endócrinos. Para determinação cromatográfica, foi desenvolvido um método analítico que utilizou filtração à vácuo seguida de análise cromatográfica acoplada a um detector UV. O eletrodo de diamante dopado com boro (BDD) foi utilizado para determinação eletroanalítica de MePa pela técnica voltamétrica. Para a análise cromatográfica, foi observada boa linearidade (0,999) na faixa de 0,5 a 30 mgL-1, com limite de detecção e quantificação de 0,49 mgL-1 e 0,73 mgL-1, respectivamente, para amostra de água natural superficial e para a amostra de cosmético 1,26 mgL-1 e 1,88 mgL-1, respectivamente. A dependência da corrente pelo pH e os parâmetros eletroquímicos (frequência, amplitude e step) foram estudados para obtenção de condições experimentais ótimas na determinação de MePa. Foi observado que o eletrólito suporte ideal é o tampão PBS 0,1 molL-1 (pH 7,5). Linearidade adequada (0,998), na mesma faixa de trabalho, com limite de detecção e quantificação de 0,43 mgL-1 e 1,44 mgL-1, respectivamente, foram encontrados para a técnica voltamétrica. Os métodos utilizados em ambas as técnicas foram validados em uma amostra de água natural superficial, coletada em região pouco impactada, e em uma amostra de cosmético. Utilizando o método cromatográfico, foram obtidos intervalos de recuperação entre 95,6% e 101,6% com RSD inferior a 4,8% (n = 3) e entre 78,0% e 99,8% com RSD inferior a 2,2% (n = 3) para amostras de água natural superficial e de cosmético, respectivamente. Na determinação eletroanalítica, soluções fortificadas daquelas amostras mostraram intervalo de recuperação entre 92,6% e 106,4%, com um desvio-padrão relativo (RSD) inferior a 9,76% (n = 3), para amostra de água superficial natural, e entre 90,0% e 112,6% com RSD inferior a 7,4% (n = 3), para amostra de cosmético. Os resultados das detecções cromatográfica e eletroanalítica foram comparados e analisados estatisticamente segundo o método de Miller e Miller. Através do teste t de Student pareado, demonstrou-se que a metodologia eletroanalítica é capaz de determinar MePa com boa precisão tal como a técnica padrão de detecção, a cromatografia, na faixa de trabalho de 1,0 a 30 mgL-1. / The high performance liquid chromatography and square wave voltammetry have been studied and compared statistically to detect the emerging contaminant methylparaben (MePa). Parabens have been widely used as preservatives in cosmetics, food and drugs. It is increasing the number of studies that aimed the detection of parabens because of its possible hazardous effect in the human health, as probably being carcinogenics and endocrine disruptors. For chromatographic determination, an analytical method that used vacuum filtration followed by chromatographic analysis coupled to a UV detector was developed. The boron doped diamond electrode (BDD) was used to electroanalytical determination to MePa by voltammetric technique. The chromatographic analysis showed good linearity (0.999) in the range from 0.5 to 30 mgL-1, with detection and quantification limit of 0.49 mgL-1 and 0.73 mgL-1, respectively, for natural surface water sample and to the cosmetic sample 1.26 mgL-1 and 1.88 mgL-1, respectively. The dependence of the current to pH and electrochemical parameters (frequency, amplitude and step) were studied to obtain the optimal experimental conditions in determining MePa. It has been observed that the ideal supporting electrolyte is PBS 0.1 molL-1 (pH 7.5). Adequate linearity (0.998), in the same working range, with detection and quantification limit of 0.43 mgL-1 and 1.44 mgL-1, respectively, were found for the voltammetric technique. The methods used in both techniques were validated in a sample of natural surface water, collected in little impacted region, and a cosmetic sample. Using the chromatographic method were obtained recovery intervals between 95.6% and 101.6% with RSD less than 4.8% (n = 3) and between 78.0% and 99.8% with RSD less than 2.2% (n = 3) for samples of natural surface water and cosmetic, respectively. In electroanalytic determination, fortified solutions of those samples showed a recovery range between 92.6% and 106.4% with a relative standard deviation (RSD) less than 9.76% (n = 3) for natural surface water sample and between 90.0% and 112.6% with RSD less than 7.4% (n = 3), for cosmetic sample. The results of chromatographic and electroanalytical detections were compared and statistically analyzed by the Miller and Miller\'s method. Using the Student\'s paired t-test, it was demonstrated that electroanalytical methodology is able to determine MePa with good accuracy as standard detection technique, chromatography, on working range of 1.0 to 30 mgL-1.
3

Patients’ experiences of Preimplantation Genetic Diagnosis (PGD)

Malmgren, Helena January 2006 (has links)
The aim of the present study was to investigate the experiences and attitudes concerningpreimplantation genetic diagnosis (PGD) among the couples that have undergone PGD in Sweden.PGD is an alternative to conventional prenatal diagnosis for couples with a high risk of having a childwith genetic disease. Couples opting for PGD have to perform in vitro fertilisation, generatedembryos are subjected to biopsy and diagnosis, and healthy embryos can be transferred to the femaleuterus. Hopefully a pregnancy will be established. However, PGD is a strategy that implies bothphysical and psychological stress, and it is not obvious that this is an easier alternative than prenataldiagnosis. A questionnaire was sent to 116 couples that had carried out at least one PGD treatmentcycle. The response rate was 89%, thus almost all couples treated in Sweden since the start in 1995was represented. Results: The stress, both psychologically and physically, caused by the PGD treatment was evaluatedsomewhere between “As expected” and “More stressful than expected”. The stress experienced duringthe PGD treatments was not associated with the couples’ previous reproductive experiences. The mostphysical stressful event was the oocyte retrieval and the most psychologically stressful period was“waiting for a possibly/ hopefully embryo transfer”.The majority of couples that had performed prenatal diagnosis on a spontaneous pregnancy andexperienced a PGD treatment reported that PGD was more physically stressful (54%), but that prenataldiagnosis was more psychologically stressful (51%). The couples reported the reproductivealternatives chosen after PGD closure, and couples performing PGD at the present rated futurereproductive alternatives. Results indicated that ocyte- and sperm donations were a less attractivealternative than for example adoption. Participants in the study also had the opportunity to state forwhom /which indications PGD should be an option. Conclusion: The stress associated with performing PGD or prenatal diagnosis is extensive and noneof the alternatives is an obvious choice. PGD was reported as more physical stressful, but prenataldiagnosis was more psychologically stressful. The reproductive pathways chosen after PGD closurewas reported, and surprisingly sperm and oocyte donations were not attractive alternatives. The choiceof reproductive alternatives might be influenced by the information and support provided by thehealthcare personal. Knowledge about the experience of PGD treatments is of great importance forthose that meet these couples for genetic and reproductive counselling, in order to give them propercare and to better meet their demand of information and support.
4

Determinação de ácido ascórbico por técnicas eletroquímicas e cromatográficas. Uma comparação estatística de desempenho. / Ascorbic Acid determination by electrochemical and chromatographic techniques. A statistical comparison of performance.

Silva, Pollyana Ferreira da 16 October 2015 (has links)
As técnicas de voltametria de pulso diferencial e de cromatografia líquida de alta eficiência foram utilizadas para a detecção do ácido ascórbico (AA) em amostras farmacêuticas. O eletrodo de carbono vítreo modificado com nanopartículas de antimônio ancoradas em nanotubos de carbono de paredes múltiplas foi utilizado para a determinação eletroanalítica de ácido ascórbico. Parâmetros como eletrólito suporte, volume adicionado do nanocompósito à superfície do eletrodo, pH do eletrólito, amplitude e incremento de potencial foram avaliados e definidos os que obtiveram os melhores resultados. A curva analítica obtida para a determinação de AA com concentrações entre 291-698 µmol L-1 em comprimidos pelo método eletroanalítico apresentou boa linearidade (0,998) e limites de detecção e quantificação 42,58 µmol L-1 e 25,00 µmg L-1, respectivamente. O método cromatográfico utilizado foi validado e a curva analítica obtida para a determinação de AA com concentrações entre 291-698 µmol L-1 em comprimidos através desse método apresentou boa linearidade (0,998) e limites de detecção e quantificação 37,24 µmol L-1 e 21,86 µmg L-1, respectivamente. Os resultados obtidos foram validados comparados estatisticamente pelo método de regressão linear descrito por Miller e Miller. Para avaliar a equivalência entre os métodos utilizou-se um teste t de Student pareado, que confirmou a equivalência dos métodos estudados para esta aplicação. / Techniques of differential pulse voltammetry and high-performance liquid chromatography were used for detection of ascorbic acid (AA) in pharmaceutical samples. The glassy carbon electrode modified with antimony nanoparticles anchored in multi-walled carbon nanotubes was used for electroanalytical determination of ascorbic acid. Parameters as supporting electrolyte, the volume of nanocomposite added to the electrode surface, pH of the electrolyte, amplitude and step potential were evaluated and defined. The calibration curve obtained by electroanalytical method for determination of AA with concentrations between 291-698 µmol L-1 using pills, showed good linearity (0.998) and limits of detection and quantification 42,58 µmol L-1 e 25,00 µmg L-1, respectively. The chromatographic method used was validated and the analytical curve obtained for determination of AA with concentrations between 291-698 µmol L-1 using pills showed good linearity (0.998) and limits of detection and quantification 37,24 µmol L-1 and 21,86 µmg L-1, respectively. The results were validated and statistically compared by the linear regression method described by Miller and Miller. To evaluate the equivalence between the methods, Student\'s paired t-test was used, which confirmed the equivalence of the methods studied for this application.
5

Determinação de ácido ascórbico por técnicas eletroquímicas e cromatográficas. Uma comparação estatística de desempenho. / Ascorbic Acid determination by electrochemical and chromatographic techniques. A statistical comparison of performance.

Pollyana Ferreira da Silva 16 October 2015 (has links)
As técnicas de voltametria de pulso diferencial e de cromatografia líquida de alta eficiência foram utilizadas para a detecção do ácido ascórbico (AA) em amostras farmacêuticas. O eletrodo de carbono vítreo modificado com nanopartículas de antimônio ancoradas em nanotubos de carbono de paredes múltiplas foi utilizado para a determinação eletroanalítica de ácido ascórbico. Parâmetros como eletrólito suporte, volume adicionado do nanocompósito à superfície do eletrodo, pH do eletrólito, amplitude e incremento de potencial foram avaliados e definidos os que obtiveram os melhores resultados. A curva analítica obtida para a determinação de AA com concentrações entre 291-698 µmol L-1 em comprimidos pelo método eletroanalítico apresentou boa linearidade (0,998) e limites de detecção e quantificação 42,58 µmol L-1 e 25,00 µmg L-1, respectivamente. O método cromatográfico utilizado foi validado e a curva analítica obtida para a determinação de AA com concentrações entre 291-698 µmol L-1 em comprimidos através desse método apresentou boa linearidade (0,998) e limites de detecção e quantificação 37,24 µmol L-1 e 21,86 µmg L-1, respectivamente. Os resultados obtidos foram validados comparados estatisticamente pelo método de regressão linear descrito por Miller e Miller. Para avaliar a equivalência entre os métodos utilizou-se um teste t de Student pareado, que confirmou a equivalência dos métodos estudados para esta aplicação. / Techniques of differential pulse voltammetry and high-performance liquid chromatography were used for detection of ascorbic acid (AA) in pharmaceutical samples. The glassy carbon electrode modified with antimony nanoparticles anchored in multi-walled carbon nanotubes was used for electroanalytical determination of ascorbic acid. Parameters as supporting electrolyte, the volume of nanocomposite added to the electrode surface, pH of the electrolyte, amplitude and step potential were evaluated and defined. The calibration curve obtained by electroanalytical method for determination of AA with concentrations between 291-698 µmol L-1 using pills, showed good linearity (0.998) and limits of detection and quantification 42,58 µmol L-1 e 25,00 µmg L-1, respectively. The chromatographic method used was validated and the analytical curve obtained for determination of AA with concentrations between 291-698 µmol L-1 using pills showed good linearity (0.998) and limits of detection and quantification 37,24 µmol L-1 and 21,86 µmg L-1, respectively. The results were validated and statistically compared by the linear regression method described by Miller and Miller. To evaluate the equivalence between the methods, Student\'s paired t-test was used, which confirmed the equivalence of the methods studied for this application.

Page generated in 0.0912 seconds