• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 173
  • 79
  • 36
  • 24
  • 16
  • 7
  • 6
  • 6
  • 5
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 441
  • 441
  • 47
  • 46
  • 43
  • 40
  • 40
  • 34
  • 32
  • 32
  • 30
  • 29
  • 27
  • 26
  • 26
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
231

Modeling Solid Propellant Ignition Events

Smyth, Daniel A. 13 December 2011 (has links) (PDF)
This dissertation documents the building of computational propellant/ingredient models toward predicting AP/HTPB/Al cookoff events. Two computer codes were used to complete this work; a steady-state code and a transient ignition code Numerous levels of verification resulted in a robust set of codes to which several propellant/ingredient models were applied. To validate the final cookoff predictions, several levels of validation were completed, including the comparison of model predictions to experimental data for: AP steady-state combustion, fine-AP/HTPB steady-state combustion, AP laser ignition, fine-AP/HTPB laser ignition, AP/HTPB/Al ignition, and AP/HTPB/Al cookoff. A previous AP steady-state model was updated, and then a new AP steady-state model was developed, to predict steady-state combustion. Burning rate, temperature sensitivity, surface temperature, melt-layer thickness, surface species at low pressure and high initial temperature, final flame temperature, final species fractions, and laser-augmented burning rate were all predicted accurately by the new model. AP ignition predictions gave accurate times to ignition for the limited experimental data available. A previous fine-AP/HTPB steady-state model was improved to predict a melt layer consistent with observation and avoid numerical divergence in the ignition code. The current fine-AP/HTPB model predicts burning rate, surface temperature, final flame temperature, and final species fractions for several different propellant formulations with decent success. Results indicate that the modeled condensed-phase decomposition should be exothermic, instead of endothermic, as currently formulated. Changing the model in this way would allow for accurate predictions of temperature sensitivity, laser-augmented burning rate, and surface temperature trends. AP/HTPB ignition predictions bounded the data across a wide range of heat fluxes. The AP/HTPB/Al model was based upon the kinetics of the AP/HTPB model, with the inclusion of aluminum being inert in both the solid and gas phases. AP/HTPB/Al ignition predictions bound the data for all but one source. AP/HTPB/Al cookoff predictions were accurate when compared to the limited data, being slightly low (shorter time) in general. Comparisons of AP/HTPB/Al ignition and cookoff data showed that the experimental data might be igniting earlier than expected.
232

Evaporative Vapor Deposition for Depositing 2D Materials

Gleason, Kevin 01 January 2015 (has links)
The development of a new deposition technique called evaporative vapor deposition (EVD) is reported, allowing deposition and formation of atomically-thin, large area materials on arbitrary substrates. This work focuses on the highly popular monolayer material – graphene oxide (GO). A droplet of a GO solution is formed on a heated polymer substrate, and maintained at steady-state evaporation (all droplet parameters are held constant over time). The polymer substrate is laser patterned to control the droplet's contact line dynamics and the droplet's contact angle is maintained using a computer controlled syringe pump. A room temperature silicon wafer is translated through the vapor field of the evaporating GO droplet using a computer controlled translation stage. Dropwise condensation formed on the silicon wafer is monitored using both optical and infrared cameras. The condensation rate is measured to be ~50pL/mm2?s – 500 pL/mm2?s and dependent on the substrate translation speed and height difference between the droplet's apex and substrate surface. Nano-sized GO flakes carried through the vapor phase are captured in the condensate, depositing on the translating wafer. Deposition rate is dependent on the stability of the solution and droplet condensate size. Characterization with Raman spectroscopy show expected shifts for graphene/graphite. The presented EVD technique is promising toward formation of large scale 2D materials with applications to developing new technologies.
233

GLR Control Charts for Monitoring a Proportion

Huang, Wandi 19 December 2011 (has links)
The generalized likelihood ratio (GLR) control charts are studied for monitoring a process proportion of defective or nonconforming items. The type of process change considered is an abrupt sustained increase in the process proportion, which implies deterioration of the process quality. The objective is to effectively detect a wide range of shift sizes. For the first part of this research, we assume samples are collected using rational subgrouping with sample size n>1, and the binomial GLR statistic is constructed based on a moving window of past sample statistics that follow a binomial distribution. Steady state performance is evaluated for the binomial GLR chart and the other widely used binomial charts. We find that in terms of the overall performance, the binomial GLR chart is at least as good as the other charts. In addition, since it has only two charting parameters that both can be easily obtained based on the approach we propose, less effort is required to design the binomial GLR chart for practical applications. The second part of this research develops a Bernoulli GLR chart to monitor processes based on the continuous inspection, in which case samples of size n=1 are observed. A constant upper bound is imposed on the estimate of the process shift, preventing the corresponding Bernoulli GLR statistic from being undefined. Performance comparisons between the Bernoulli GLR chart and the other charts show that the Bernoulli GLR chart has better overall performance than its competitors, especially for detecting small shifts. / Ph. D.
234

A Combined Modular and Simultaneous Linear Equation Executive System for Process Simulation

Lislois, Joseph Paul Georges Hebert 12 1900 (has links)
<p> A new computer executive system for the steady state simulation of chemical processes has been developed which combines modular (GEMCS) approach with the simultaneous linear equation (SYMBØL) approach to simulation. In the combined system, a GEMCS simulation, using non-linear models, is used to generate the coefficients for the set of linear equations describing the process. This linear system of equations may also include the constraints on the process which dictate the operating conditions for the actual process. The solution of the linear equations then provide new operating conditions (feed flowrates together with the component flowrates in the recycle streams) for the modular simulation, which in turn provides new coefficients; etc. This iterative procedure is automatically continued until the system is converged to the desired point. </p> <p> A modular simulation for an actual Naphtha Reforming Plant has also been achieved and it was used as a test case to demonstrate the use and effectiveness of this new executive system. In the course of developing this simulation, the application of a method for correcting plant data was demonstrated. This is the first real application of this method to be reported in the current literature. </p> / Thesis / Master of Engineering (ME)
235

Mathematical modeling of prostate cancer immunotherapy

Coletti, Roberta 08 June 2020 (has links)
Immunotherapy, by enhancing the endogenous anti-tumor immune responses, is showing promising results for the treatment of numerous cancers refractory to conventional therapies. However, its effectiveness for advanced castration-resistant prostate cancer remains unsatisfactory and new therapeutic strategies need to be developed. To this end, mathematical modeling provides a quantitative framework for testing in silico the efficacy of new treatments and combination therapies, as well as understanding unknown biological mechanisms. In this dissertation we present two mathematical models of prostate cancer immunotherapy defined as systems of ordinary differential equations. The first work, introduced in Chapter 2, provides a mathematical model of prostate cancer immunotherapy which has been calibrated using data from pre-clinical experiments in mice. This model describes the evolution of prostate cancer, key components of the immune system, and seven treatments. Numerous combination therapies were evaluated considering both the degree of tumor inhibition and the predicted synergistic effects, integrated into a decision tree. Our simulations predicted cancer vaccine combined with immune checkpoint blockade as the most effective dual-drug combination immunotherapy for subjects treated with androgen-deprivation therapy that developed resistance. Overall, this model serves as a computational framework to support drug development, by generating hypotheses that can be tested experimentally in pre-clinical models. The Chapter 3 is devoted to the description of a human prostate cancer mathematical model. The potential effect of immunotherapies on castration-resistant form has been analyzed. In particular, the model includes the dendritic vaccine sipuleucel-T, the only currently available immunotherapy option for advanced prostate cancer, and the ipilimumab, a drug targeting the cytotoxic T-lymphocyte antigen 4 , exposed on the CTLs membrane, currently under Phase II clinical trial. From a mathematical analysis of a simplified model, it seems likely that, under continuous administration of ipilimumab, the system lies in a bistable situation where both the no-tumor equilibrium and the high-tumor equilibrium are attractive. The schedule of periodic treatments could then determine the outcome, and mathematical models could help in deciding an optimal schedule.
236

Cis-Acting Elements in Mechanism of HIV-1 Reverse Transcription

Ignatov, Michael E. 12 July 2006 (has links)
No description available.
237

Investigating Current Mechanistic Models of DNA Replication and Repair

Wallenmeyer, Petra C., Wallenmeyer January 2017 (has links)
No description available.
238

Steady-State Analysis of PWM Z-Bridge Source DC-DC Converter

Kathi, Lokesh January 2015 (has links)
No description available.
239

Fluorescence and NMR Characterization of a T Box Antiterminator-tRNA Complex

Means, John A. January 2007 (has links)
No description available.
240

Development and Characterization of a Stopped-Flow-Bypass Analysis System With Applications To Biochemical Measurements

Hillard, Stephen Wayne 11 March 1997 (has links)
A new apparatus called Bypass Trapped Flow Analysis System (ByT-FAS) is described. A properly designed ByT-FAS gives an analyst the ability to use analyte sample volumes of 10 to 200 μL [or more] and reagent volumes of approximately the same size. The sample and reagent are injected into their respective carrier streams and attain physical steady state concentrations in the detection cell within approximately 15 to 45 seconds after injection. Upon achievement of simultaneous sample and reagent physical steady state concentrations, the system flow is diverted around the detection cell and the reaction mixture is trapped in the detection cell. The concentration of the sample and reagent in the detection cell can be readily computed from knowledge of the original concentrations of the sample and reagent and the flow rates of the streams propelling the sample and reagent. ByT-FAS was demonstrated to be useful for direct measurements of analytes in liquid solutions and for assays which utilize equilibrium and/or kinetic methods to create measurable product(s) for ultraviolet/visible spectrophotometry, fluorimetry, and chemiluminescence. Enzyme activities and fundamental enzyme kinetic parameters (Kms, Kis, VMAXs) were determined directly. Genetic transcription levels of luciferase in whole intact E. coli cells were also determined using chemiluminescent detection. Flow system configuration, components, and flow ratios were investigated for their effects on achieving physical steady state signals in the detector. It is believed that this new type of instrumentation will be of significant use for the analytical chemical, biochemical, molecular biology, biotechnology, environmental, pharmaceutical and medical communities for those measurements which require direct knowledge of the concentration of the reactants and products during quantitation. / Ph. D.

Page generated in 0.042 seconds