• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Direct Strength Method for Web Crippling of Cold-formed Steel C and Z Sections Subjected to Interior One Flange Loading and End One Flange Loading

Dara, Martin Luther 12 1900 (has links)
The main objective of this research is to extend the “Direct strength method” for determining the web crippling strength of cold-formed steel C and Z sections subjected to End one flange loading and Interior one flange loading conditions. Direct strength method is applied for designing the columns and beams earlier. The existing specifications equation for calculating the web crippling strength of cold-formed steels designed by American Institute of Iron and Steel is very old method and it is based on the extensive experimental investigations conducted at different universities. Calculating the web crippling strength of cold-formed steels using direct strength method is a new technique. In the present research the web crippling strength of cold-formed steels were calculated using Direct Strength Method. The experimental data is collected from the tests that were conducted at different universities. The critical buckling strength of the members were calculated using Abaqus. Microsoft excel is used to generate the equations. The safety and resistance factors for the designed equations were calculated using “Load and resistance factor design” and “Allowable strength design” from North American Cold-Formed Steel Specification, 2012 edition book.
2

Nominal Shear Strength and Seismic Detailing of Cold-formed Steel Shear Walls using Steel Sheet Sheathing

Chen, Yujie 08 1900 (has links)
In this research, monotonic and cyclic tests on cold-formed steel shear walls sheathed with steel sheets on one side were conducted to (1) verify the published nominal shear strength for 18-mil and 27-mil steel sheets; and (2) investigate the behavior of 6-ft. wide shear walls with multiple steel sheets. In objective 1: this research confirms the discrepancy existed in the published nominal strength of 27-mil sheets discovered by the previous project and verified the published nominal strength of 18 mil sheet for the wind design in AISI S213. The project also finds disagreement on the nominal strength of 18-mil sheets for seismic design, which is 29.0% higher than the published values. The research investigated 6-ft. wide shear wall with four framing and sheathing configurations. Configuration C, which used detailing, could provide the highest shear strength, compared to Configurations A and B. Meanwhile, the shear strength and stiffness of 2-ft. wide and 4-ft. wide wall can be improved by using the seismic detailing.
3

Seismic Performance Evaluation of Novel Cold-Formed Steel Framed Shear Walls Sheathed with Corrugated Steel Sheets

Lan, Xing 08 1900 (has links)
This thesis presents experiments and numerical analysis of a novel cold-formed steel framed shear wall sheathed with corrugated steel sheets. The objective of this newly designed shear wall is to meet the growing demand of mid-rise buildings and the combustibility requirement in the International Building Code. The strength of the novel shear wall is higher than currently code certified shear wall in AISI S400-15 so that it could be more favorable for mid-rise building in areas that are prone to earthquakes and hurricanes. Full-scale monotonic and cyclic tests were conducted on bearing walls and shear walls under combined lateral and gravity loads. Though the gravity loads had negative effects on the strength and stiffness of the shear wall due to the buckling of the chord framing members, it still shows promise to be used in mid-rise buildings. The objective of numerical analysis is to quantify the seismic performance factors of the newly design shear wall lateral-force resisting system by using the recommended methodology in FEMA P695. Two groups of building archetypes, story varied from two to five, were simulated in OpenSees program. Nonlinear static and dynamic analysis were performed in both horizontal directions of each building archetype. Finally, the results of the performance evaluation verified the seismic performance factors(R=Cd=6.5 and Ω =3.0) were appropriate for the novel shear wall system.
4

Analytical Model for Lateral Deflection in Cold-formed Steel Framed Shear Walls with Steel Sheathing

Yousof, Mohamad 12 1900 (has links)
An analytical model for lateral deflection in cold-formed steel shear walls sheathed with steel is developed in this research. The model is based on the four factors: fastener displacement, steel sheet deformation, and hold-down deformation, which are from the effective strip concept and a complexity factor, which accounts for the additional influential factors not considered in the previous three terms. The model uses design equations based on the actual material and mechanical properties of the shear wall. Furthermore, the model accounts for aggressive and conservative designers by predicting deflection at different shear strength degrees.

Page generated in 0.1049 seconds