• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Application of High Entropy Alloys in Stent Implants

Alagarsamy, Karthik 05 1900 (has links)
High entropy alloys (HEAs) are alloys with five or more principal elements. Due to these distinct concept of alloying, the HEA exhibits unique and superior properties. The outstanding properties of HEA includes higher strength/hardness, superior wear resistance, high temperature stability, higher fatigue life, good corrosion and oxidation resistance. Such characteristics of HEA has been significant interest leading to researches on these emerging field. Even though many works are done to understand the characteristic of these HEAs, very few works are made on how the HEAs can be applied for commercial uses. This work discusses the application of High entropy alloys in biomedical applications. The coronary heart disease, the leading cause of death in the United States kills more than 350,000 persons/year and it costs $108.9 billion for the nation each year in spite of significant advancements in medical care and public awareness. A cardiovascular disease affects heart or blood vessels (arteries, veins and capillaries) or both by blocking the blood flow. As a surgical interventions, stent implants are deployed to cure or ameliorate the disease. However, the high failure rate of stents has lead researchers to give special attention towards analyzing stent structure, materials and characteristics. Many works related to alternate material and/or design are carried out in recent time. This paper discusses the feasibility of CoCrFeNiMn and Al0.1CoCrFeNi HEAs in stent implant application. This work is based on the speculation that CoCrFeNiMn and Al0.1CoCrFeNi HEAs are biocompatible material. These HEAs are characterized to determine the microstructure and mechanical properties. Computational modeling and analysis were carried out on stent implant by applying CoCrFeNiMn and Al0.1CoCrFeNi HEAs as material to understand the structural behavior.
2

Study of Mechanical Performance of Stent Implants Using Theoretical and Numerical Approach

Yang, Hua, (Mechanical engineer) 08 1900 (has links)
The coronary heart disease kills more than 350,000 persons/year and it costs $108.9 billion for the United States each year, in spite of significant advancements in clinical care and education for public, cardiovascular diseases (CVD) are leading cause of death and disability to the nation. A cardiovascular disease involves mainly heart or blood vessels (arteries, veins and capillaries) or both, and then mainly occurs in selected regions and affects heart, brain, kidney and peripheral arteries. As a surgical interventions, stent implantation is deployed to cure or ameliorate the disease. However, the high failure rate of stents used in patients with peripheral artery diseases has lead researchers to give special attention towards analyzing stent structure and characteristics. In this research, the mechanical properties of a stent based on the rhombus structure were analyzed and verified by means of analytical and numerical approaches. Theoretical model based on the beam theory were developed and numerical models were used to analyze the response of these structures under various and complex loading conditions. Moreover, the analysis of the stent inflation involves a model with large deformations and large strains, nonlinear material properties need to be considered to accurately capture the deformation process. The maximum stress values were found to occur in localized regions of the stent. These regions were generally found along the inner radii of each of the connected links connecting each of the longitudinal struts. Stress values throughout the whole stent were typically much lower. The peak engineering stress values were found to be less than the material ultimate strength (limit stress 515Mpa), indicating a safe stent design throughout expansion range. Lastly, the rheological behavior of blood can be quantified by non-Newtonian viscosity. Carreau model is introduced and simulates the situation in the artery, then the available shear stress in the model would help to the future analysis in the contact analysis of stent and the artery.

Page generated in 0.0906 seconds