Spelling suggestions: "subject:"stimulateurs cardiaque"" "subject:"simulateurs cardiaque""
1 |
Advances in cardiac pacing : clinical aspects of novel pacemaker leads and algorithms. Behavior of stimulation thresholds and impedances in modern pacemaker systems.Danilović, Dejan. January 1998 (has links)
Diss.--Faculty of medicine--University of Bergen, 1998.
|
2 |
L' endocardite sur matériel de stimulation intracardiaque à propos des cas relevés au CHU de Nancy entre 1998 et 2008 /Berivan, Azman Suty, Christine. January 2009 (has links) (PDF)
Thèse d'exercice : Médecine : Nancy 1 : 2009. / Titre provenant de l'écran-titre.
|
3 |
Contribution à l'optimisation et à la modélisation d'un banc de mesure CEM Application à la caractérisation de l'immunité des stimulateurs cardiaques /Andretzko, Jean-Paul Hedjiedj, Fadil. Guendouz, Laouès. January 2007 (has links) (PDF)
Thèse de doctorat : Instrumentation et Micro-Electronique : Nancy 1 : 2007. / Titre provenant de l'écran-titre. Bibliogr.
|
4 |
Compatibilité électromagnétique des implants médicaux actifs évaluation théorique et expérimentale du comportement des stimulateurs cardiaques exposés à des perturbations électromagnétiques de basses fréquences /Babouri, Abdesselam Hedjiedj, Ahcène. January 2007 (has links) (PDF)
Thèse doctorat : Instrumentation et Micro-Electronique : Nancy 1 : 2007. / Titre provenant de l'écran-titre.
|
5 |
Importance de la réserve contractile dans la réponse hémodynamique à la resynchronisation cardiaqueBars, Clément. Elbaz, Nathalie January 2006 (has links) (PDF)
Thèse d'exercice : Médecine. Cardiologie : Paris 12 : 2006. / Titre provenant de l'écran-titre. Bibliogr. f. 48-55.
|
6 |
Caractérisation du détecteur à fibre scintillante plastique commercial et étude sur la réduction de dose aux appareils cardiaques implantables par blindage de plombBourgouin, Alexandra 23 April 2018 (has links)
Le récent développement de la méthode de discrimination spectrale pour la calibration des dosimètres à fibres scintillantes plastiques (PSD) a conduit au développement du premier dosimètre commercial de ce type, soit l’Exradin W1 (STANDARD IMAGING INC., Middleton, WI, U.S.). Comme tout nouveau dosimètre, celui-ci se devait d’être caractérisé afin d’évaluer sa fiabilité en conditions standards d’irradiation. Le but premier du projet était d’effectuer cette validation. Les résultats obtenus ont démontré que le dosimètre à scintillation était un excellent candidat pour réaliser des mesures de dose hors-champ telles que rencontrées lors de l’évaluation de la réduction de dose aux appareils cardiaques implantables (ACI) par blindage. Les mesures effectuées avec l’Exradin W1 ont démontré une importante réduction de dose autant pour les simples champs antéro-postérieurs (de 40 % à 80 % de réduction de dose) que pour les traitements cliniques complexes (entre 5 % et 45 % de réduction de dose). / The recent development of the spectral method for correction of the Cˇ erenkov light in plastic scintillation detectors (PSD) have led to the first commercial dosimeter of this type, the Exradin W1 (STANDARD IMAGING INC., Middleton, WI, U.S.). As any new commercial dosimeter, it had to be characterized and validated in different situations of radiation. The first purpose of this project was to perform this validation. The results of characterization have shown that PSD is an efficient dosimeter to make out-of-field doses measurements as required in the evaluation of the feasibility of using a lead sheet to reduce dose to Cardiac Implantable Electronic Devices, CIED. Measurements performed with PSD shown an important reduction of doses by the shielding for square anterior-posterior field (40 % to 80 %) and also for complex clinical treatments (5 % to 45 %).
|
7 |
Contribution à l'optimisation et à la modélisation d'un banc de mesure CEM - Application à la caractérisation de l'immunité des stimulateurs cardiaquesAndretzko, Jean-Paul 08 October 2007 (has links) (PDF)
L'objectif de cette thèse concerne l'optimisation d'un banc de mesure CEM destiné à la caractérisation in vitro de l'immunité des stimulateurs cardiaques aux perturbations électromagnétiques de basse fréquence ainsi que l'aspect modélisation numérique. Dans une première partie, après avoir présenté les bases théoriques du bioélectromagnétisme, nous abordons le fonctionnement électrique du cœur et une description fonctionnelle des stimulateurs cardiaques. Une revue de la littérature consacrée aux interactions entre stimulateurs cardiaques et sources d'interférences est exposée. L'optimisation du banc de mesure concerne la source de champ magnétique et le modèle équivalent tissu qui permet les essais in vitro. La source de champ magnétique réalisée est une structure originale constituée de quatre bobines contenues dans une enveloppe sphérique qui permet de produire un champ magnétique homogène à l'ordre 4. Le modèle équivalent tissu est réalisé sur la base d'une solution saline. Dans le quatrième chapitre, après une revue des différentes méthodes de simulation numérique utilisées en dosimétrie électromagnétique, nous présentons une méthode numérique originale basée sur la méthode des impédances qui permet de déterminer les potentiels induits dans un milieu soumis à un couplage galvanique. Le dernier chapitre concerne la mesure et la simulation de tension induite, in vitro, aux bornes d'un stimulateur soumis à des perturbations conduites et rayonnées. La démarche proposée permet ensuite de déterminer, par simulation numérique, le niveau d'immunité d'un stimulateur cardiaque soumis à des perturbations électromagnétiques en fonction de ses caractéristiques électriques, des caractéristiques géométriques d'implantation ainsi que du milieu de couplage.
|
Page generated in 0.0587 seconds