• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Extensometria : avaliação de implantes de sextavado externo posicionados na configuração linear e compensada (offset), sob carregamento axial /

Kojima, Alberto Noriyuki. January 2008 (has links)
Orientador: Renato Sussumu Nishioka / Banca: Wirley Gonçalves Assunção / Banca: Alysson Noriyuki Kajishima Konno / Banca: Eduardo Shigueyuki Uemura / Banca: Osvaldo Daniel Andreatta Filho / Resumo: O objetivo deste estudo foi avaliar, por meio da extensometria, a distribuição de tensões ao redor de implantes em função dos diferentes locais para carregamento, tipo de coifa (plástica ou usinada) e configuração (linear e compensada). Para tanto, em um bloco de poliuretano, foram posicionados paralelos entre si e com uma configuração linear, implantes auto-rosqueáveis de hexágono externo, com dimensões de 3,75 X 13mm, a uma distancia de 7mm, de centro a centro. Em um outro bloco a fixação do meio foi deslocada em 2mm para gerar uma configuração compensada (offset). Pilares protéticos Micro-unit, com 3mm de cinta foram instalados sobre as fixações. Com duas matrizes em aço inoxidável foram confeccionados 10 enceramentos para cada bloco, distribuídos da seguinte forma: 5 para coifa plástica e 5 para coifas usinadas (n=5). A seguir esses padrões foram fundidos com uma liga de Co-Cr. Quatro extensômetros (strain gauges) foram colados na superfície superior de cada bloco tangenciando a plataforma de cada fixação. Um carregamento de 30kg durante 10s foi feito em cinco posições (A, B, C, D, E), sendo repetido três vezes para aquisição dos dados (em με) pela aparelho condicionador de sinais. Os dados obtidos foram submetidos a análise de variância (ANOVA) e teste de Tukey (p<0,05). Como conclusão da análise dos resultados obtidos pudemos observar que não houve diferença na utilização de coifas plásticas e usinadas, que não houve diferença entre as configurações linear e compensada; havendo diferença estatisticamente significante para os locais de carregamento / Abstract: The aim of this study was to evaluate, using strain gauge, the load distribution surround the implants according differents loading sites, coping types (plastic and machined) and configuration (linear and offset). In one polyurethane block, three cylindrical implants with external hexagon (3.75mm x 13mm) were fixed parallel with 7mm between their centers in a linear configuration. In another block the midle implant was positioned in a 2mm offset. Micro-units abutments with 3mm of metallic neck were fixed. With two metallics matrix, it was manufactured 10 wax patterns for each block, distributed in the following form: 5 for plastic copings and 5 for machined copings (n=5). After, patterns were casted in cobalt-chromium alloy. Four strain gauges were positioned on the upper surface of each polyurethane model around the implants. An axial load of 30kg within 10 seconds in five positions (A, B, C, D, E), with three repetead measurements for data aquisition (in με) by the multichanel bridge machine. The datas were submitted to ANOVA and Tukey test (p<0.05). Such as conclusion from the obtained data treatment: there was no difference between the plastic and machined copings, there was no difference between the linear and offset configuration; there was statiscal significance only with the differents loading sites. / Doutor
2

Extensometria: avaliação de implantes de sextavado externo posicionados na configuração linear e compensada (offset), sob carregamento axial

Kojima, Alberto Noriyuki [UNESP] 07 July 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-07-07Bitstream added on 2014-06-13T20:25:48Z : No. of bitstreams: 1 kojima_an_dr_sjc.pdf: 500670 bytes, checksum: 06c2a32f2d0fe96b743e1f05b9e95270 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar, por meio da extensometria, a distribuição de tensões ao redor de implantes em função dos diferentes locais para carregamento, tipo de coifa (plástica ou usinada) e configuração (linear e compensada). Para tanto, em um bloco de poliuretano, foram posicionados paralelos entre si e com uma configuração linear, implantes auto-rosqueáveis de hexágono externo, com dimensões de 3,75 X 13mm, a uma distancia de 7mm, de centro a centro. Em um outro bloco a fixação do meio foi deslocada em 2mm para gerar uma configuração compensada (offset). Pilares protéticos Micro-unit, com 3mm de cinta foram instalados sobre as fixações. Com duas matrizes em aço inoxidável foram confeccionados 10 enceramentos para cada bloco, distribuídos da seguinte forma: 5 para coifa plástica e 5 para coifas usinadas (n=5). A seguir esses padrões foram fundidos com uma liga de Co-Cr. Quatro extensômetros (strain gauges) foram colados na superfície superior de cada bloco tangenciando a plataforma de cada fixação. Um carregamento de 30kg durante 10s foi feito em cinco posições (A, B, C, D, E), sendo repetido três vezes para aquisição dos dados (em με) pela aparelho condicionador de sinais. Os dados obtidos foram submetidos a análise de variância (ANOVA) e teste de Tukey (p<0,05). Como conclusão da análise dos resultados obtidos pudemos observar que não houve diferença na utilização de coifas plásticas e usinadas, que não houve diferença entre as configurações linear e compensada; havendo diferença estatisticamente significante para os locais de carregamento / The aim of this study was to evaluate, using strain gauge, the load distribution surround the implants according differents loading sites, coping types (plastic and machined) and configuration (linear and offset). In one polyurethane block, three cylindrical implants with external hexagon (3.75mm x 13mm) were fixed parallel with 7mm between their centers in a linear configuration. In another block the midle implant was positioned in a 2mm offset. Micro-units abutments with 3mm of metallic neck were fixed. With two metallics matrix, it was manufactured 10 wax patterns for each block, distributed in the following form: 5 for plastic copings and 5 for machined copings (n=5). After, patterns were casted in cobalt-chromium alloy. Four strain gauges were positioned on the upper surface of each polyurethane model around the implants. An axial load of 30kg within 10 seconds in five positions (A, B, C, D, E), with three repetead measurements for data aquisition (in με) by the multichanel bridge machine. The datas were submitted to ANOVA and Tukey test (p<0.05). Such as conclusion from the obtained data treatment: there was no difference between the plastic and machined copings, there was no difference between the linear and offset configuration; there was statiscal significance only with the differents loading sites.
3

Resistência à fratura, padrão de fratura e deformação de raízes com canais excessivamente alargados restaurados com diferentes pinos e técnicas - avaliação mecânica e por extensometria

Silva, Gisele Rodrigues da 26 February 2007 (has links)
Fundação de Amparo a Pesquisa do Estado de Minas Gerais / The widening of the root canal increases its fracture risk and is not clear yet, the influence of the materials and techniques used to restore these teeth. The aim of this study was to evaluate the effect of different posts and restorative techniques in the fracture resistance, fracture mode and root strain in canals excessively widened. One hundred thirty five standardized bovine roots, with similar dimensions and endodontically treated, were randomly divided in 9 groups (n=15) with the root canals prepared with 10 mm depth and 1.5 mm diameter. All roots received ferrule in the coronal ending with 0.5 mm depth and 2 mm extension. The roots of two reference groups were reconstructed with nickel-chromium metallic cast post-and-core (NMF) and glass fiber post (PFV) with composite resin core. For the experimental groups (weakened roots - wc groups), the root canals were over prepared additionally with the depth of 9 mm and the diameter increased to approximately 3,5 mm. Then the roots were restored with metallic cast post-and-core (wcNMF); glass fiber post (wcPFV); glass fiber post associated with accessory glass - ap - fiber post (wcPFVap); direct composite resin - cr - in the medial and cervical thirds after luting the post (wcPFVcr); direct composite resin associated with accessory posts in the medial and cervical thirds, after luting the post (wcPFVcrap); the post was reembased indirectly with composite resin - icr - (wcPFVicr); the post was reembased indirectly with composite resin associated with accessory posts (wcPFVicrap). All posts were fixed with chemical resinous cement, the core was made with composite resin and the roots restored with metallic crown. The samples were submitted to 3x105 mechanical fatigue cycles of 50 N load and fracture resistance measured in a mechanical testing machine with tangential load application (135º). Five samples of each group received two strain gauges adhered in the mesial and buccal surfaces of the root, 1mm below the cervical crown ending, in the center of the tooth, to measure roots strain under continuous 0 to 100 N loading. Fracture mode was classified in accordance to the degree of destruction of the dental structure, in catastrophic or repairable. The data were submitted to ANOVA (2x2)l to one-way and Tukey´s test (&#945;=0.05). The factorial analysis demonstrated significant decrease of the fracture resistance and catastrophic failures for the wcNMF group. Roots widened canals restored with composite resin and/or accessory fiber posts result in fracture resistance values similar to NMF group, however, these demonstrated more repairable fracture. The strain-gauge analysis didn t present significant differences in the superficial strain of the root. Fiber glass post associated with composite resin or with accessory fiber glass posts, seems to be more indicated as alternative to metallic cast post-and-core in weakened roots, because of the lower risk of catastrophic fractures. / O alargamento do canal aumenta o risco de fratura dentária e ainda não está clara a influência dos materiais e técnicas empregados para restaurar dentes com estas características. Assim, o objetivo deste estudo foi avaliar o efeito de diferentes pinos e técnicas restauradoras na resistência à fratura, padrão de fratura e deformação de raízes com canais excessivamente alargados. Foram empregadas 135 raízes bovinas com dimensões semelhantes, tratadas endodonticamente, aleatoriamente divididas em 9 grupos (n= 15). Os canais foram preparados com 10 mm de profundidade e 1,5 mm de diâmetro e as raízes receberam preparo com férula de 0,5 mm de profundidade e 2 mm de extensão. Dois grupos de referência foram restaurados com retentores intraradiculares metálicos fundidos em níquel-cromo (NMF) e pino de fibra de vidro (PFV) com núcleo de preenchimento em resina composta. Para os demais grupos, os canais radiculares foram alargados na profundidade de 9 mm e o diâmetro aumentado para ±3,5 mm, padronizando a espessura de dentina remanescente em 0,5mm no terço coronário da raiz. Os canais alargados (ca) foram então restaurados com, núcleo metálico fundido (caNMF); pino de fibra de vidro (caPFV); pino de fibra de vidro associado a pinos de fibra de vidro acessórios (caPFVpa); preenchimento direto com resina composta nos terços médio e cervical após cimentação do pino (caPFVrd); preenchimento direto com resina composta associado a pinos acessórios, após cimentação do pino (caPFVrdpa); pino reembasado com resina composta de forma indireta (caPFVri); pino reembasado com resina composta de forma indireta associado a pinos acessórios (caPFVripa). Todos os procedimentos de cimentação foram realizados com cimento resinoso de ativação química, os núcleos de preenchimento em resina composta e as raízes restauradas com coroa total metálica. As amostras foram submetidas a 3x105 ciclos de fadiga mecânica de 50N de carga. Em cinco amostras de cada grupo, dois extensômetros foram aderidos à raiz, um na mesial e outro na vestibular, 1 mm abaixo do limite cervical da coroa, no centro do dente, para mensurar a deformação das raízes sob carregamento contínuo de 0 a 100N. A resistência à fratura (N) das amostras foi então medida em máquina de ensaio mecânico com aplicação de carga tangencial (135º). Os dados foram submetidos à análise de variância fatorial (2x2), para comparar o efeito do tipo de retentor em função do tipo de raiz, e em fator único, para avaliar os métodos de preenchimento, seguido pelo teste de Tukey (&#945;=0,05). O padrão de fratura foi classificado de acordo com o grau de comprometimento da estrutura dentária em catastrófica ou reparável. A análise estatística fatorial demonstrou significativa redução da resistência à fratura e falhas catastróficas para o grupo caNMF. Valores de resistência comparável ao grupo NMF e padrão de fratura reparável foram obtidos em raízes com canais alargados, sempre que a resina composta ou pinos de fibra acessórios foram utilizados. Não houve diferença significante na deformação externa da raiz entre os grupos estudados. Pode-se concluir que o uso de pinos de fibra de vidro, associado ao preenchimento com resina composta e/ou pinos de fibra de vidro acessórios, parece ser mais indicado como alternativa ao núcleo metálico fundido em raízes fragilizadas, devido ao menor risco de fraturas catastróficas. / Mestre em Odontologia

Page generated in 0.0865 seconds