• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Production and Evaluation of Rapid Tooling for Electric Discharge Machining using Electroforming and Spray Metal Deposition Techniques

Blom, Ricky J January 2005 (has links)
To survive in today's manufacturing environments companies must push the standards of accuracy and speed to the highest levels possible. Electro Discharge Machining (EDM) has been used for over 50 years and recent developments have seen the use of EDM become much more viable. The goal of this research is to produce and evaluate electrodes produced by different manufacturing methods. The use of electroforming and spray-metal deposition has only recently become viable methods of producing usable rapid tooling components. The speed and accuracy as well as the cost of manufacture play a vital role in the tool and mould manufacturing process. Electroforming and spray-metal deposition offer an alternate option to traditional machining of electrodes. Electroforming is one method of producing electrodes for EDM. The fact that electroforming can be used to produce multiple electrodes simultaneously gives it the advantage of saving on costs when multiple electrodes are needed. Spray-metal deposition offers another alternative that is much cheaper and relatively faster to manufacture. The used of these non-traditional manufacturing methods in this research are compared to the performance of traditional solid electrodes in terms of machining time, material removal rate, tool wear rates and surface roughness at several standard machining settings. The results of this research are presented in this thesis along with conclusions and comments on the performance of the different methods of electrode manufacture. The major findings of the research include the solid electrodes performed better than the electroformed electrodes in Material Removal Rate (MRR), Tool Wear Rate (TWR), and Surface Roughness (Ra) at all machine settings. However it was found that the production cost of the solid electrodes was six times that of the electroformed electrodes. The production of spray metal electrodes was unsuccessful. The electrode shell walls were not an even thickness and the backing material broke through the shell making them unusable. It is concluded that with further refinements and research, electroforming and spray metal processes will become an extremely competitive method in electrode manufacture and other rapid tooling processes.
2

Comparative in vitro study of selected physical properties of activa, cention n and vitremer

Mohammed Khair, Ro'aa Mohammed Jafar Mohammed January 2021 (has links)
Magister Theologiae - MTh / This study aimed to determine the association between dimensional change and surface roughness (Ra) of Vitremer, Activa and Cention N after immersing them into two different media: acidic and artificial saliva media for the period of a year. Measurements were made at 10 time intervals during the observation period.
3

Comparative in vitro study of selected physical properties of Activa, Cention N and Vitremer

Khair, Ro’aa Mohammed Jafar Mohammed Mohammed January 2021 (has links)
Magister Chirurgiae Dentium (MChD) / Background: This study aimed to determine the association between dimensional change and surface roughness (Ra) of Vitremer, Activa and Cention N after immersing them into two different media: acidic and artificial saliva media for the period of a year. Measurements were made at 10 time intervals during the observation period. Methodology: This was a quantitative and qualitative study. For the quantitative part, a total of 60 specimens were tested, 20 specimens for each material. The 20 specimens were further divided into 10 specimens. Ten were immersed in acidic media and the rest in saliva media. A measurement of the weight, height, and Ra was carried out as follows: day 0, day 1, day 2, day 7, day 21, day 28, day 60, day 90, day 180 and day 365. Scanning electron microscopy (SEM) was used to examine the surface of each material qualitatively pre and post immersion in the two media. For fluoride measurements, an additional five samples from each material were left suspended in the de-ionized water by the use of dental floss. The materials were moved to new specimen jars after the completion of day 1, 2, 3, 4, 5, 6, 7, 14, 21 and 28. All the specimen jars had been kept for the fluoride measurements. Results: Non-parametric tests were used to analyze the data. Linear regression analysis was used to measure the association between weight, height or surface roughness (Ra) and immersion time for a year. The result of this test showed that Vitremer had a significant association between the weight (p = 0.000), height (p = 0.007) and Ra (p = 0.001) when it was immersed in acidic media. On the other hand, when Vitremer was immersed in saliva media, only the weight variable showed a significant association (p = 0.002). For Cention N, significant association was found for only Ra when immersed in acidic media (p = 0.000). Finally, for Activa, all the studied associations; the weight, height and Ra in both media were found to be insignificant. For saliva media, there was a significant weight change between the three materials during all 10 periods of time (p = 0.000). In the first six months, Cention N demonstrated a significant increase in weight changes followed by Vitremer, then Activa. Yet, after a year, the difference between Cention N and Vitremer became insignificant and Activa showed the least weight changes. There was not a significant difference between the materials in terms of height and Ra measurements. The fluoride experiment was not successful due to technical issues during pH measurements of the collected solutions. For comparison of the studied parameters between the three materials, the Kruskal-Wallis test was used. In acidic media, there was a significant difference between the materials in term of weight change in 10 periods of time (p = 0.000). In particular, after a two month period, Cention N had the highest weight, followed by Vitremer and then by Activa. The difference between Vitremer and Activa became insignificant throughout the rest of the experimental time frame. All the height measurements between the three materials were found to be insignificant except for day 365 (p = 0.048), where both Activa and Cention N were found to be significantly higher than Vitremer. For the Ra comparison, in the first two weeks, particularly day 1, 7 and 14, Cention N had significantly the lowest Ra among the other materials. As the three materials aged in the acidic media (day 180), Vitremer had significantly the highest Ra values. Cention N showed higher Ra values than Activa; nonetheless this difference was not significant. The SEM images showed loss of some particles in all post-experimental images of the materials in acidic media. Vitremer showed the widest cracks with the loss of fillers. In saliva media, there was also loss of particles but to a lesser extent than in acidic media. Yet, the post-experimental image of Activa in saliva resembled the pre-experimental one. Conclusion: Within the limitations of the study, the best material to resist Ra from prolonged acidic attack was Activa followed by Cention N and then Vitremer. Except for Vitremer, no significant changes in the Ra of the other materials were detected when the three materials were immersed in saliva media in the long term. In acidic media Vitremer tended to lose weight and height faster than Cention N and Activa over a year. Cention N is the best material to resist dimensional change. However, in artificial saliva Vitremer gained water rapidly. Activa did not absorb a lot of water and did not reject a lot of water; Activa demonstrated good dimensional stability and this property may be beneficial when compared to the other two materials tested. The clinical significance of the study: All the materials studied were subjected to dimensional and Ra changes following long-term exposure to acidic substances, but the newer materials (Cention N and Activa) seemed to be more dimensionally stable and resistant to Ra changes than the older, well-known material (Vitremer). This may influence a clinician’s choice of restorative material for use in pediatric dentistry.
4

Optimalizace parametrů broušení slinutých karbidů diamantovými kotouči / Optimization of grinding characteristics when grinding cemented carbides by diamond wheels

Mangl, Petr January 2009 (has links)
This master‘s thesis is presenting the way of the optimization of grinding characteristics when grinding cemented carbides by diamond wheels. There is described the theory of grinding, including grinding wheels and basic characteristics of cemented carbides in the theoretical part. There are defined experimental metering accomplished on the CNC grinding machine Walter Helitronic Power Mini in the practical part. There were tested eight grinding wheels. The grinding rate, surface roughness Ra, theoretic guaranteed storage period of grinding wheel in number of cuts, theoretical capacity of machined material, achievement of grinding machine and behaviour of the wheels when grinding ware evaluated from the reached results.

Page generated in 0.0353 seconds