• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Contribution à l’étude des modes de dégradation des transistors HEMT à base de GaN pour les applications de puissance / Contribution to the study of degradation modes of transistors HEMT based on GaN for power applications.

Elharizi, Malika 21 November 2018 (has links)
Les composants de puissance à base de GaN sont connus par l’instabilité de leurs caractéristiques électriques, en particulier la tension de seuil et la résistance à l'état passant. Cela est dû aux effets des mécanismes de piégeage/de-piégeage des charges dans la structure. Le travail présenté dans ce mémoire se compose de deux grandes parties. Dans un premier temps, nous mettons en évidence l’effet d’un certain nombre de paramètres de commutation sur l'évolution de la résistance dynamique avec des cycles de commutation successifs. Nous analysons, en particulier, l’effet de la tension au blocage, la fréquence de commutation et la température sur l'évolution de la résistance dynamique. Dans un deuxième temps, nous présentons les résultats des essais de cyclage de puissance effectués en utilisant 80K de variation de température de jonction sur des puces de puissance MOS-HEMT Al2O3/AlGaN/GaN Normally-On. Ensuite, nous réalisons des caractérisations de pièges, basées sur des analyses de mesures de courants transitoires pendant le processus de vieillissement. Les résultats montrent qu’une dégradation irréversible affecte la tension de seuil avec une dérive vers des valeurs négatives. Ces dérives sont principalement attribuables au piégeage cumulatif avec des cycles de puissance, probablement induits par des électrons chauds, d’une manière progressive et non récupérable. / Power components based on GaN are known by the instability of their electrical characteristics, in particular the threshold voltage and the on-state resistance. This is due to the effects of trapping/de-trapping mechanisms in the structure. The work presented in this memoir consists of two main parts. At the first step, we highlight the effect of a number of switching parameters on the evolution of the dynamic resistance with successive switching cycles. In particular, we analyze the effect of blocking voltage, switching frequency and temperature on the evolution of dynamic resistance. In a second step, we present the results of power cycling tests performed using 80K of junction temperature swing on Normally-ON Al2O3/AlGaN/GaN MOS-HEMTs. Then, we perform trap characterizations, based on the analyses of transient current measurements, during the aging process. The results show that irreversible degradation affects threshold voltage with drift to negative values. These drifts were mainly attributed to cumulative trapping with power cycles, probably induced by hot electrons, in a progressive and non-recoverable way.
2

Avaliação do rendimento luminoso e a vida útil das lâmpadas fluorescentes compactas em regime de uso intermitente. / Evaluation of luminous performance and lifetime of compact fluorescent lamps in the regime of intermittent use.

Espínola Velázquez, Emigdio Concepcion 09 November 2016 (has links)
Esta tese tem como principal objetivo medir o desempenho das lâmpadas fluorescentes compactas em regime de uso intermitente instaladas em residências. Utiliza a Norma NBR 14539 e a PORTARIA 489/2010 como referência, para a comparação dos valores obtidos nas medições de campo com as medições do laboratório. A metodologia aplicada tem a finalidade de medir o desempenho em um ambiente real e muito mais agressivo que o laboratório. Foram instaladas 95lâmpadas de três marcas diferentes e dividida em três grupos, previamente as lâmpadas foram sazonadas ou \"envelhecidas\" por 100 horas e posteriormente instaladas nas residências. Neste estágio, as medições de campo foram realizadas durante dezoito meses em quatro oportunidades, (a primeira como referência), posteriormente foram retiradas e levadas novamente ao laboratório para medir a depreciação do fluxo luminoso. As variáveis medidas foram: Fluxo luminoso, iluminância, tensão, temperatura, umidade relativa e quantidade de chaveamento para o acendimento das lâmpadas. Para ter uma visão mais ampla, os resultados, foram comparados à norma brasileira com as normas internacionais em relação aos requisitos de desempenho das lâmpadas fluorescentes compactas. Também foi feito um questionário com os consumidores que participaram desta pesquisa, para verificar o conhecimento ou a \"cultura energética\" relacionada com a forma de uso da iluminação, manutenção dos circuitos, idade, gênero, situação laboral, classe social, consumo, escolha de lâmpadas na hora da compra, uso da iluminação natural, utilização de tintas claras no interior das residências. Todo procedimento de medições foi realizado no Laboratório de Fotometria do Instituto de Energia e Ambiente-IEE da Universidade de São Paulo/USP. / This thesis aims to verify the performance of compact fluorescent lamps (CFLs) that are installed in residences in intermittent use regime. It uses NBR 14539 and Ordinance 489/2010 as a reference for comparing the values measured in the field in the laboratory measurements. The methodology used to verify the performance in a real environment is more aggressive than the laboratory\'s. 95 lamps of three different brands were installed, which were divided into three groups, The lamps were previously seasoned or \"aged\" for 100 hours and then installed in residences. At this stage, the field measurements were conducted for eighteen months, four times until reaching 2,000 hours of use. Later, they were removed and taken back to the laboratory to check the depreciation. Measured variables were: Iluminância, voltage, temperature, relative humidity and the amount of switching to lighting the lamps. To consolidate, Brazilian standards were compared to international standards in order to verify if there are differences or coinciding points. A questionnaire was also filled in by consumers who participated in this research to verify the knowledge or \"energy culture\" related to the proper use of lighting, maintenance of circuits, age, gender, employment status, social class, consumption, choice of lamps at the time of purchase, use of natural lighting, use of clear paint inside the residences. Finally, it is worth mentioning that the entire measurement procedure was performed in the photometry laboratory of the Institute of Energy and Environment-IEE, University of São Paulo/USP.
3

Avaliação do rendimento luminoso e a vida útil das lâmpadas fluorescentes compactas em regime de uso intermitente. / Evaluation of luminous performance and lifetime of compact fluorescent lamps in the regime of intermittent use.

Emigdio Concepcion Espínola Velázquez 09 November 2016 (has links)
Esta tese tem como principal objetivo medir o desempenho das lâmpadas fluorescentes compactas em regime de uso intermitente instaladas em residências. Utiliza a Norma NBR 14539 e a PORTARIA 489/2010 como referência, para a comparação dos valores obtidos nas medições de campo com as medições do laboratório. A metodologia aplicada tem a finalidade de medir o desempenho em um ambiente real e muito mais agressivo que o laboratório. Foram instaladas 95lâmpadas de três marcas diferentes e dividida em três grupos, previamente as lâmpadas foram sazonadas ou \"envelhecidas\" por 100 horas e posteriormente instaladas nas residências. Neste estágio, as medições de campo foram realizadas durante dezoito meses em quatro oportunidades, (a primeira como referência), posteriormente foram retiradas e levadas novamente ao laboratório para medir a depreciação do fluxo luminoso. As variáveis medidas foram: Fluxo luminoso, iluminância, tensão, temperatura, umidade relativa e quantidade de chaveamento para o acendimento das lâmpadas. Para ter uma visão mais ampla, os resultados, foram comparados à norma brasileira com as normas internacionais em relação aos requisitos de desempenho das lâmpadas fluorescentes compactas. Também foi feito um questionário com os consumidores que participaram desta pesquisa, para verificar o conhecimento ou a \"cultura energética\" relacionada com a forma de uso da iluminação, manutenção dos circuitos, idade, gênero, situação laboral, classe social, consumo, escolha de lâmpadas na hora da compra, uso da iluminação natural, utilização de tintas claras no interior das residências. Todo procedimento de medições foi realizado no Laboratório de Fotometria do Instituto de Energia e Ambiente-IEE da Universidade de São Paulo/USP. / This thesis aims to verify the performance of compact fluorescent lamps (CFLs) that are installed in residences in intermittent use regime. It uses NBR 14539 and Ordinance 489/2010 as a reference for comparing the values measured in the field in the laboratory measurements. The methodology used to verify the performance in a real environment is more aggressive than the laboratory\'s. 95 lamps of three different brands were installed, which were divided into three groups, The lamps were previously seasoned or \"aged\" for 100 hours and then installed in residences. At this stage, the field measurements were conducted for eighteen months, four times until reaching 2,000 hours of use. Later, they were removed and taken back to the laboratory to check the depreciation. Measured variables were: Iluminância, voltage, temperature, relative humidity and the amount of switching to lighting the lamps. To consolidate, Brazilian standards were compared to international standards in order to verify if there are differences or coinciding points. A questionnaire was also filled in by consumers who participated in this research to verify the knowledge or \"energy culture\" related to the proper use of lighting, maintenance of circuits, age, gender, employment status, social class, consumption, choice of lamps at the time of purchase, use of natural lighting, use of clear paint inside the residences. Finally, it is worth mentioning that the entire measurement procedure was performed in the photometry laboratory of the Institute of Energy and Environment-IEE, University of São Paulo/USP.

Page generated in 0.0757 seconds