• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Investigating Transient Overvoltage Produced by Switching Action on Long Transmission Lines and Its Effect on Substations

January 2018 (has links)
abstract: Switching surges are a common type of phenomenon that occur on any sort of power system network. These are more pronounced on long transmission lines and in high voltage substations. The problem with switching surges is encountered when a lot of power is transmitted across a transmission line/network, typically from a concentrated generation node to a concentrated load. The problem becomes significantly worse when the transmission line is long and when the voltage levels are high, typically above 400 kV. These overvoltage transients occur following any type of switching action such as breaker operation, fault occurrence/clearance and energization, and they pose a very real danger to weakly interconnected systems. At EHV levels, the insulation coordination of such lines is mainly dictated by the peak level of switching surges, the most dangerous of which include three phase line energization and single-phase reclosing. Switching surges can depend on a number of independent and inter-dependent factors like voltage level, line length, tower construction, location along the line, and presence of other equipment like shunt/series reactors and capacitors. This project discusses the approaches taken and methods applied to observe and tackle the problems associated with switching surges on a long transmission line. A detailed discussion pertaining to different aspects of switching surges and their effects is presented with results from various studies published in IEEE journals and conference papers. Then a series of simulations are presented to determine an arrangement of substation equipment with respect to incoming transmission lines; that correspond to the lowest surge levels at that substation. / Dissertation/Thesis / Masters Thesis Electrical Engineering 2018
2

Evaluation of Polymeric MV Power Cable Insulation Condition based on Online Capacitor Switching Transient Voltage Measurements

Pushpanathan, Balaji 09 May 2015 (has links)
The underground power cable failures introduce challenges to the reliability of underground residential distribution networks. Smart Grid initiatives have interest to improve equipment reliability. Asset management of several utilities are interested towards online cable insulation condition monitoring and health index evaluation. This dissertation demonstrates a new technique for online condition assessment of power cable insulation condition based on capacitor switching transient voltage measurements. While majority of utilities in USA are following corrective maintenance for MV cables, only few utilities have procedures in place for offline preventive maintenance of MV cables. The technique demonstrated in this research will enable all utilities to carry out preventive online monitoring of MV power cables. This dissertation also demonstrates that capacitive test point of cable elbow connector can be used to measure switching transients for power cables in service. This technique can be easily incorporated into existing capacitive test points of cable accessories. This technique has a potential to develop and deploy measurement units for online monitoring of power cables.

Page generated in 0.0655 seconds