• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Etude et amélioration d’une pompe à chaleur pour véhicule électrique en conditions de givrage / Study and improvement of a heat pump for electric vehicles Under frosting conditions

Breque, Florent 24 October 2017 (has links)
Dans le cadre du développement des voitures électriques (VE), la solution de chauffage de l’habitacle par pompe à chaleur (PAC) s’impose graduellement en raison des plus grandes efficacités de ces dernières par rapport aux résistances électriques classiques. Cependant, dans certaines conditions, du givre se forme sur l’évapo-condenseur entraînant une dégradation marquée des performances du système. L’enjeu général de ce travail est donc de développer une PAC pour VE efficace en conditions de givrage afin d’améliorer l'autonomie en hiver. Pour ce faire, un évapo-condenseur résistant au givrage est nécessaire. Afin d’améliorer le design de l’échangeur, un modèle dynamique et pseudo 3D d’échangeur à microcanaux, typique de l’automobile, en conditions de givrage a été développé. Un sous-modèle de croissance de givre à la fois simple et précis a été établi en étudiant les différentes hypothèses de modélisation trouvées dans la littérature. Ensuite, au niveau échangeur de chaleur, la clé réside dans la bonne prédiction des pertes de charge aérauliques. Ainsi, une nouvelle approche a été de considérer les épaisseurs maximales locales de givre et une corrélation intégrant l’impact du givre afin de bien prédire les pertes de charge, la chute du débit d’air, et donc la chute de la puissance thermique de l’échangeur. Le modèle complet d’échangeur de chaleur couplé à un ventilateur a été validé expérimentalement. À partir d’une étude numérique basée sur le modèle, deux concepts innovants ont été établis : l’un avec ailettes ondulées débordantes et l’autre avec passes de réfrigérant croisées. Deux prototypes ont été fabriqués, à partir de l’évapo-condenseur de la Renault Zoé, puis testés. Le meilleur des deux échangeurs, celui à ailettes débordantes, a été monté sur véhicule et comparé à l’échangeur de la Zoé. Le prototype a permis d’allonger d’environ 2.5 fois la période de fonctionnement du système. Finalement, un modèle de PAC avec givrage a été réalisé et intégré dans un modèle complet de VE. Pour un VE avec une autonomie d’environ 140 km sans chauffage, il s’avère que le givrage de la PAC dégrade l’autonomie d’environ 15% pour un trajet à 0°C et 90% d'humidité. Grâce à l’utilisation du prototype à ailettes ondulées débordantes, cette perte d’autonomie est de 3% seulement. / In the electric vehicle (EV) development context, the choice of heat pumps (HP) for cabin heating is becoming more popular due to their high efficiency compared to electric heaters. However, under some operating conditions, frost forms on the HP evapo-condenser causing a dramatic drop in the system performances until the system cannot operate. Hence, this work aims at developing a HP for EV which remains efficient under frosting conditions ultimately, to improve the EV range in the winter. This requires the design of a frost-resistant heat exchanger (HX). First, to improve the HX design, a dynamic and pseudo-3D model under frosting conditions of a typical HX for cars has been developed. A simple and accurate frost growth sub-model has been established by studying the various modeling assumptions found in the literature. Then, at the HX level, the key point has been to predict the air pressure losses, via the consideration of the maximum local frost thicknesses and the development of a correlation considering frost, in order to predict the drop of airflow and therefore the drop of the HX cooling capacity. Then, the model of the HX coupled with the fan has been validated experimentally. Using the model, a numerical study has been conducted and two innovative concepts have been established: one with wavy upstream extending fins and the other with crossed passes of refrigerant. Two prototypes were fabricated, using a reference HX taken from the Renault Zoé, and then tested. The best of the two HX, the one with upstream extending fins, was mounted on a VE and compared to the reference case. The prototype allowed extending the system operation by 2.5 times approximately. Finally, a HP model under frosting conditions was built and integrated into a EV model. It appeared that, for an EV with a range of approximately 140 km without heating, the HP frosting degrades the autonomy by about 15% at 0°C and 90% humidity, which was reduced to 3% via the use of the innovative HX prototype with wavy upstream extending fins.
2

Règles de modélisation des systèmes énergétiques dans les bâtiments basse consommation / Modeling rules of energy system in low energy buildings

Blervaque, Hubert 20 October 2014 (has links)
La réduction des besoins dans les bâtiments à basse consommation d'énergie (BBC) nécessite un réexamen de l'approche de modélisation des systèmes énergétiques dans les outils de simulation. L'approche proposée repose sur une modélisation plus fine des phénomènes physiques incluant la régulation en boucle fermée du système énergétique couplé au bâtiment. A partir de l'identification des phénomènes propres au comportement énergétique des BBC, des recommandations, ou règles de modélisation, sont établies pour le développement des modèles de leurs systèmes énergétiques. Ces recommandations sont mises en application dans deux études. Tout d'abord, une simulation dynamique d'un bâtiment et de son système conduit à un dimensionnement plus adapté comparé aux méthodes classiques dans le cas de BBC avec des répercussions sur les appels de puissance et la consommation d'énergie. Ensuite, une analyse de sensibilité par la méthode de Morris sur une représentation générique du système énergétique a permis d'identifier les paramètres nécessitant d'être connus avec précision. La différence entre l'approche développée et la simulation horaire avec régulation idéale n'est que de quelques pourcents en besoins énergétiques pour un bâtiment existant mais elle passe à plus de 20% dans un bâtiment BBC. Un écart du même ordre de grandeur peut être identifié pour la détermination de la performance énergétique globale du système par une prise en compte plus détaillée des phénomènes de cyclage, de charge partielle ou de consommation des auxiliaires. / The decrease of heat demands in low energy buildings requires to examine again modeling approaches in building energy simulation tools. The developed approach is based on a more accurate modeling of physical phenomena including the closed loop control between the HVAC system and the building. From the identification of the phenomena that specifically impact the energy behavior of the low energy buildings, some recommendation, or modeling rule, are established for the development of their HVAC systems. Those recommendations are applied in two case studies. Firstly, a dynamic simulation of a building and its system offers a better evaluation of the design power for a low energy building, affecting power demands and energy consumption. Then, a sensitivity analysis from Morris method on a generic representation of the HVAC system identifies the parameters to be accurately known. The difference between the developed approach and an hourly simulation with an ideal control is low for the evaluation of the heat load in an existing building but it is more than 20% in a low energy buildings. A difference of the same order of magnitude can be identified in the determination of the overall energy performance of the system by a more detailed consideration of the phenomena of cycling, the part load or the consumption of auxiliaries.

Page generated in 0.02 seconds