• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de metodologia para a determinação da razão isotópica 87Sr/86Sr por ICP-MS - um traçador natural para águas de produção em reservatórios de petróleo e águas subterrâneas

Marcos Eduardo dos Santos 31 August 2010 (has links)
Nenhuma / O decaimento radioativo beta (ß-) do 87Rb para o 87Sr é um importante sistema isotópico que tem sido amplamente aplicado para propostas geocronológicas, em identificação de sistemas de água subterrânea, interação entre aquíferos e como traçador para os processos de recuperação secundária em plataforma de petróleo via injeção da água do mar. A razão 87Sr/86Sr presente na água do mar é constante no mundo, enquanto águas de formação em reservatórios de hidrocarbonetos tem vários valores e em muitos casos é maior que a água do mar atual. Isto pode ser a base para um traçador natural apontando para a avaliação do desempenho dos processos de injeção da água do mar pela avaliação da razão 87Sr/86Sr e o conteúdo total de Sr da água de formação no reservatório antes da injeção, seguido pelo monitoramento desse valores na água de produção via espectrometria de massa. Este estudo propôs avaliar a utilização de um espectrômetro de massa com plasma indutivamente acoplado (ICP-MS) e sistema de quadrupolo, em função de sua mais disseminada disponibilidade. Para tanto foram coletadas amostras de água de reservatório de petróleo e de água subterrânea para medir seus conteúdos de Sr e a suas respectivas razões 87Sr/86Sr. Após o pré-tratamento das amostras, as soluções foram submetidas a uma etapa de separação do Rb e Sr por troca iônica para evitar interferência isobárica na determinação da razão isotópica do estrôncio. Para avaliar o método de separação, foram usadas a resina convencional Dowex AG50WX8-400 e colunas comercias pré-empacotadas com a resina Sr-spec. O espectrômetro de massa utilizado foi um equipamento Perkin-Elmer ELAN DRC-e. A precisão requerida para esse propósito de utilização da razão 87Sr/86Sr como traçador natural para a detecção do breakthrough da água de injeção nos poços de produção de reservatórios de petróleo uma informação tão somente qualitativa, conquanto altamente valiosa para a gerência da produção do reservatório - não requer necessariamente uma alta precisão. Desta maneira, o estudo verificou a capacidade do ICP-MS com sistema de quadrupolo para medir a razão 87Sr/86Sr nas águas de reservatórios e subterrâneas com menores desvios padrões possíveis. Os resultados deste trabalho sugerem que a razão 87Sr/86Sr é uma promissora ferramenta como traçador natural em reservatórios de petróleo e sistemas de água subterrânea. / The radioactive beta (ß-) decay of 87Rb to 87Sr is an important isotope system that has been widely applied for geochronological purposes and in identifying ground water sources, aquifer interactions and as a tracer for a secondary recovery process in offshore oilfields via seawater injection. The 87Sr/86Sr ratio of present-day seawater is constant worldwide, while formation waters in hydrocarbon reservoirs have diverse values that are in most cases higher than those of modern seawater. This can be the basis for a natural tracer technique aiming at evaluating the performance of seawater injection processes in enhanced oil recovery by evaluating the 87Sr/86Sr ratio and the total Sr content of formation waters in the reservoir prior to injection, followed by monitoring these values in the produced water as injection proceeds. The objective of this study was to evaluate the feasibility of using a inductively coupled plasma mass spectrometer (ICP-MS) with a quadrupole system for this purpose, due to the widespread availability of this class of MS equipment. Accordingly samples of water from oilfield reservoirs and from groundwater were collected for measurement of the Sr content and of the 87Sr/86Sr ratio. Following sample pre-treatment and prior to isotope ratio mesurements, the solutions were submitted to Rb and Sr separation via cation-exchange to overcome isobaric interferences in the determination of strontium isotope ratios. Aiming at evaluating this method of separation, both the conventional Dowex AG50WX8-400 cation-exchange resin and commercial pre-packed columns filled with Sr resin were chosen. A Perkin-Elmer ELAN DRC-e spectrometer has been used for the measurements. The tests were performed using the Sr isotopic standard reference material NIST SRM 987 and external correction for mass discrimination. This work describes the methodology that was be used for the determination of variations in the isotopic composition of Sr in the water of reservoir and groundwater and presents the results obtained by determination of the 87Sr/86Sr. The precision required for using this ratio as a natural tracer for the detection of the injection water breakthrough at the production wells in oil reservoirs a fundamentally qualitative information, although a quite valuable one in oil reservoir management does not necessarily require high precision. Hence the study checked the applicability of the quadrupole based ICP-MS measurement the 87Sr/86Sr ratio in the water of reservoir and groundwater with the lowest achievable standards deviations. The results this study suggest that the 87Sr/86Sr ratio is a promising tool in oilfield reservoir and groundwater systems.

Page generated in 0.0892 seconds