• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 2
  • Tagged with
  • 5
  • 5
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Vascular and morphological changes of the optic nerve head following therapeutic intraocular pressure reduction in open angle glaucoma and ocular hypertension

Hafez, Ali S. January 2007 (has links)
Thèse numérisée par la Division de la gestion de documents et des archives de l'Université de Montréal.
2

Vascular and morphological changes of the optic nerve head following therapeutic intraocular pressure reduction in open angle glaucoma and ocular hypertension

Hafez, Ali S. January 2007 (has links)
Thèse numérisée par la Division de la gestion de documents et des archives de l'Université de Montréal
3

Une nouvelle méthode de détection du glaucome par la mesure de l'asymétrie interoculaire : l’asymétrie du rapport de la surface neurorétinienne sur la surface du disque optique ou rim area to disc area asymmetry ratio (RADAAR)

Kamdeu Fansi, Alvine A. 11 1900 (has links)
Cette thèse constitue à la fois un apport de nature clinique et technologique dans l’approche diagnostique du glaucome. Plus précisément, nous nous proposons d’étudier une nouvelle façon de détecter le glaucome par la mesure de l’asymétrie du rapport de la surface de l’anneau neurorétinien et de la surface de la papille ou du disque optique ou rim to disc area asymmetry ratio (RADAAR). Pour atteindre cet objectif, nous avons recours à une base de données composée d’une population subdivisée en 4 différents groupes de diagnostic (normal, glaucome possible, glaucome probable et glaucome définitif). Les mesures du RADAAR sont calculées de différentes façons à partir des paramètres stéréométriques de la tête du nerf optique des sujets, produits par la microscopie confocale à balayage laser (Heidelberg Retina Tomograph (HRT) (Heidelberg Engineering, Germany)). Nous procédons à une analyse de données grâce au logiciel SPSS où nous mettons en exergue la distribution du RADAAR dans les différentes populations, sa validité et son utilité dans le dépistage du glaucome. Nous enrôlons donc 523 sujets dans cette étude avec 82 sujets atteints de glaucome définitif. La moyenne d’âge est de 62 ans. Il y a plus de femmes que d’hommes et plus de Caucasiens que d’Africains Caribéens. Nous trouvons que la distribution de la mesure du RADAAR est différente des sujets d’un groupe de diagnostic à l’autre. En termes de performance, la sensibilité de la mesure du RADAAR est très basse c'est-à-dire que sa capacité de détecter la maladie est basse. En revanche la mesure du RADAAR est plus spécifique c'est-à-dire que sa capacité d’identifier les sujets exempts de la maladie est plus grande. Elle tendrait à être aussi plus performante chez les Africains Caribéens que chez les Caucasiens. De même, elle serait plus sensible chez les hommes que chez les femmes. La mesure du RADAAR est utile si on l’associe à une autre méthode de diagnostic comme l’analyse de Régression de Moorfields (MRA) incluse dans le logiciel du HRT3 spécialement lors de la détection du glaucome dans la population à haut risque. En définitive, nous déterminons que la mesure du RADAAR se veut un outil d’aide au diagnostic. Elle est particulièrement intéressante dans le contexte de dépistage de glaucome. / This thesis describes a new clinical and technological approach to the diagnosis of glaucoma. Specifically, we intend to study a new way to detect glaucoma by measuring rim area to disc area asymmetry ratio (RADAAR). For this purpose, we use a database consisting of a population divided into 4 different diagnostic groups (normal, possible glaucoma, probable glaucoma and definitive glaucoma). The RADAAR measurements are calculated in different ways based on the stereometric parameters of the optic nerve head of subjects, produced by confocal scanning laser ophthalmoscopy (Heidelberg Retina Tomograph (HRT) (Heidelberg Engineering, Germany)). We conduct an analysis of data with SPSS or we put forward the RADAAR distribution in different populations, its validity in detecting open angle glaucoma and its usefulness in screening for glaucoma. We therefore enroll 523 subjects in this study with about 82 subjects with definitive glaucoma. The average age is 62 years. There are more females than males and more Caucasians than Africans Caraibeans. We find that the distribution of RADAAR measures is different in each diagnosis group. In terms of performance, the sensitivity of the RADAAR measurement is very low. So, its ability to detect the disease is low. However the RADAAR measure is much more specific so, its ability to identify subjects free of the disease is high. RADAAR measure would also be much more effective in African Caribbean’s than in Caucasians. Similarly, it would be much more sensitive in males than in females. The RADAAR measurement is useful if it is combined with another method of diagnosis like the Moorfields regression analysis (MRA) included in the HRT3 software especially in case of the detection of glaucoma in populations at high risk. Ultimately, we determine that the RADAAR is an interesting tool for the diagnosis of glaucoma particularly in the context of screening for glaucoma.
4

Une nouvelle méthode de détection du glaucome par la mesure de l'asymétrie interoculaire : l’asymétrie du rapport de la surface neurorétinienne sur la surface du disque optique ou rim area to disc area asymmetry ratio (RADAAR)

Kamdeu Fansi, Alvine A. 11 1900 (has links)
Cette thèse constitue à la fois un apport de nature clinique et technologique dans l’approche diagnostique du glaucome. Plus précisément, nous nous proposons d’étudier une nouvelle façon de détecter le glaucome par la mesure de l’asymétrie du rapport de la surface de l’anneau neurorétinien et de la surface de la papille ou du disque optique ou rim to disc area asymmetry ratio (RADAAR). Pour atteindre cet objectif, nous avons recours à une base de données composée d’une population subdivisée en 4 différents groupes de diagnostic (normal, glaucome possible, glaucome probable et glaucome définitif). Les mesures du RADAAR sont calculées de différentes façons à partir des paramètres stéréométriques de la tête du nerf optique des sujets, produits par la microscopie confocale à balayage laser (Heidelberg Retina Tomograph (HRT) (Heidelberg Engineering, Germany)). Nous procédons à une analyse de données grâce au logiciel SPSS où nous mettons en exergue la distribution du RADAAR dans les différentes populations, sa validité et son utilité dans le dépistage du glaucome. Nous enrôlons donc 523 sujets dans cette étude avec 82 sujets atteints de glaucome définitif. La moyenne d’âge est de 62 ans. Il y a plus de femmes que d’hommes et plus de Caucasiens que d’Africains Caribéens. Nous trouvons que la distribution de la mesure du RADAAR est différente des sujets d’un groupe de diagnostic à l’autre. En termes de performance, la sensibilité de la mesure du RADAAR est très basse c'est-à-dire que sa capacité de détecter la maladie est basse. En revanche la mesure du RADAAR est plus spécifique c'est-à-dire que sa capacité d’identifier les sujets exempts de la maladie est plus grande. Elle tendrait à être aussi plus performante chez les Africains Caribéens que chez les Caucasiens. De même, elle serait plus sensible chez les hommes que chez les femmes. La mesure du RADAAR est utile si on l’associe à une autre méthode de diagnostic comme l’analyse de Régression de Moorfields (MRA) incluse dans le logiciel du HRT3 spécialement lors de la détection du glaucome dans la population à haut risque. En définitive, nous déterminons que la mesure du RADAAR se veut un outil d’aide au diagnostic. Elle est particulièrement intéressante dans le contexte de dépistage de glaucome. / This thesis describes a new clinical and technological approach to the diagnosis of glaucoma. Specifically, we intend to study a new way to detect glaucoma by measuring rim area to disc area asymmetry ratio (RADAAR). For this purpose, we use a database consisting of a population divided into 4 different diagnostic groups (normal, possible glaucoma, probable glaucoma and definitive glaucoma). The RADAAR measurements are calculated in different ways based on the stereometric parameters of the optic nerve head of subjects, produced by confocal scanning laser ophthalmoscopy (Heidelberg Retina Tomograph (HRT) (Heidelberg Engineering, Germany)). We conduct an analysis of data with SPSS or we put forward the RADAAR distribution in different populations, its validity in detecting open angle glaucoma and its usefulness in screening for glaucoma. We therefore enroll 523 subjects in this study with about 82 subjects with definitive glaucoma. The average age is 62 years. There are more females than males and more Caucasians than Africans Caraibeans. We find that the distribution of RADAAR measures is different in each diagnosis group. In terms of performance, the sensitivity of the RADAAR measurement is very low. So, its ability to detect the disease is low. However the RADAAR measure is much more specific so, its ability to identify subjects free of the disease is high. RADAAR measure would also be much more effective in African Caribbean’s than in Caucasians. Similarly, it would be much more sensitive in males than in females. The RADAAR measurement is useful if it is combined with another method of diagnosis like the Moorfields regression analysis (MRA) included in the HRT3 software especially in case of the detection of glaucoma in populations at high risk. Ultimately, we determine that the RADAAR is an interesting tool for the diagnosis of glaucoma particularly in the context of screening for glaucoma.
5

Ocular biomechanics in glaucoma and space-related neuro-ocular syndrome : assessing ocular rigidity and pulsatile optic nerve deformation with video-optical coherence tomography.

Masís-Solano, Marissé 04 1900 (has links)
La compréhension des propriétés biomécaniques de la tête du nerf optique (TNO) est cruciale pour la gestion de conditions telles que le glaucome et le Syndrome Neuro-Oculaire Lié à l'Espace (SNOE). Cette thèse propose d’utiliser l'imagerie par tomographie de cohérence optique vidéo à haute fréquence (V-OCT) traitée avec des algorithmes de traitement d'image existants pour évaluer quantitativement la déformation pulsatile de la TNO due aux cycles cardiaques. Cette méthode est utilisée afin d’investiguer deux phénomènes: la réponse biomécanique de la TNO dans les conditions terrestres; et la réponse du TNO dans l'environnement de microgravité de l'espace. Le premier segment de cette thèse présente une nouvelle méthode non-invasive pour mesurer le déplacement pulsatile de la TNO via l'OCT vidéo (V-OCT), offrant des progrès significatifs dans la quantification des propriétés biomécaniques de l'œil in vivo. Une validation approfondie de cette technique, à la fois numérique et expérimentale, a confirmé la sensibilité de l'algorithme aux déformations induites, sa robustesse face à divers niveaux de bruit, et sa répétabilité. Deux groupes d’individus, sains et myopes, ont été évalués sous différentes conditions de contrainte physiologique. La déformation pulsatile des tissus de la TNO a été capturée quantitativement et représentée sous forme de cartes de déformation, montrant la sensibilité de la méthodologie aux déformations induites et la robustesse aux interférences de bruit élevé. Pour les sujets dont les yeux ont une longueur axiale de moins de 25mm, des différences notables de déformation pulsatile médiane ont émergé entre les positions primaires et en abduction de l'œil, avec une reproductibilité confirmée via des coefficients de corrélation intra-classe élevés. Ayant validé la méthode, elle a donc a été appliquée à une cohorte de glaucomateux pour examiner l'impact de la réduction de la pression intraoculaire (PIO) sur le déplacement pulsatile de la TNO. Chez les patients atteints de glaucome primaire à angle ouvert (GPAO), en particulier ceux sans myopie axiale, les interventions abaissant la PIO ont conduit à une réduction significative de la pulsation de la TNO. Cependant, les patients glaucomateux myopes n'ont affiché aucun changement substantiel, suggérant une relation nuancée entre la modulation de la PIO et la biomécanique de la TNO. Une étude de cohorte n’a révélé aucune différence marquée dans la pulsation de la TNO à travers divers degrés de gravité du glaucome. Pourtant, la déformation pulsatile a été corrélée à l'épaisseur de la couche de fibres nerveuses rétiniennes et à des mesures hémodynamiques spécifiques, soulignant les interconnexions complexes entre la biomécanique et l'hémodynamique oculaires. La dernière partie de cette thèse aborde les modifications de la rigidité oculaire chez les astronautes avant et après des vols spatiaux prolongés. En analysant les données de 26 yeux de 13 astronautes, la recherche a démontré des réductions significatives de la rigidité oculaire, de la pression intraoculaire et de l'amplitude du pouls oculaire après la mission. Ces découvertes explorent des effets précédemment inconnus de la microgravité sur les propriétés mécaniques de l'œil, améliorant notre compréhension du SNOE. Cette étude, tout en approfondissant notre compréhension des complexités biomécaniques et hémodynamiques de la TNO, démontre le potentiel du V-OCT comme outil pour le diagnostic et le suivi des conditions du nerf optique. Les techniques et les perspectives acquises ici posent également les bases pour de futures explorations prometteuses à la fois pour les patients atteints de glaucome et pour les astronautes. / The eye is a semi-rigid sphere with complex biomechanical properties. Chronic disease or stress like space flight can interfere with these properties, leading to vision loss. Noninvasive measurements of the biomechanical properties of the optic nerve head (ONH) could provide better tracking and management of conditions such as glaucoma and Space-Related Neuro-Ocular Syndrome (SANS). This thesis proposes to use high-frequency optical coherence tomography video imaging (V-OCT) with existing image processing algorithms to quantitatively evaluate the pulsatile displacement of the ONH due to cardiac cycles. This methodology is applied across two streams of research: examining the ocular biomechanical response of the ONH under terrestrial conditions; and the ONH deformation in the microgravity environment of space. The first section of this thesis introduces a non-invasive method to measure ONH pulsatile displacement via video-based OCT (V-OCT), quantifying biomechanical eye properties in vivo. A thorough validation of this technique, both numerically and experimentally, confirmed the algorithm’s sensitivity to induced deformation, robustness against various noise levels, and repeatability. Two groups, healthy and myopic individuals, underwent assessment under different physiological strain conditions. Pulsatile ONH tissue deformation was quantitatively captured and represented as deformation maps. For those subjects with eyes with an axial length of less than 25mm, notable median pulsatile displacement differences were found between primary and abducted eye positions. Reproducibility was confirmed via high intraclass correlation coefficients. Building on this foundation, the method was applied to a cohort of glaucoma patients to examine the impact of IOP reduction on ONH pulsatile displacement. In primary open-angle glaucoma (POAG) patients, particularly those without axial myopia, IOP-lowering interventions significantly reduced ONH pulsation. However, myopic glaucoma patients displayed no substantial changes, suggesting that myopic status moderates the relationship between IOP modulation and ONH biomechanics. This pilot study was expanded to a larger cross-sectional cohort study (N=176), revealing a decrease in ONH pulsatile displacement in people with early and moderate glaucoma compared to controls. . In addition, pulsatile displacement correlated with retinal nerve fiber layer thickness and specific hemodynamic measures, showing that ocular biomechanics and hemodynamics are closely linked. The last section of the thesis investigates ocular rigidity alterations in astronauts before and after extended space flights. Analyzing data from 26 eyes of 13 astronauts, significant reductions in ocular rigidity were observed; similarly, intraocular pressure and ocular pulse amplitude were reduced post-mission. These findings reveal previously undocumented microgravity effects on the eye's mechanical properties, improving our comprehension of SANS. This thesis demonstrates the potential of V-OCT as a tool for the diagnosis and assessment of the progression of optic nerve conditions. By gaining a deeper understanding of the biomechanical and hemodynamic intricacies of the ONH, we lay the groundwork for future explorations that hold promise for both glaucoma patients and astronauts.

Page generated in 0.1107 seconds