Avaliação de riscos aplicada como metodologia de controle e segurança da qualidade da água no sistema de abastecimento de Belém - PA

ARAÚJO JUNIOR, Antonio Jorge Silva 08 March 2016 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-03-16T12:15:13Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AvaliacaoRiscosAplicada.pdf: 17022853 bytes, checksum: f000bfda10885096b77dac9d9a13483e (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-17T13:53:50Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AvaliacaoRiscosAplicada.pdf: 17022853 bytes, checksum: f000bfda10885096b77dac9d9a13483e (MD5) / Made available in DSpace on 2017-03-17T13:53:50Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AvaliacaoRiscosAplicada.pdf: 17022853 bytes, checksum: f000bfda10885096b77dac9d9a13483e (MD5) Previous issue date: 2016-03-08 / O presente trabalho tem como objetivo principal utilizar a abordagem de avaliação de risco FMEA como metodologia de controle e segurança da qualidade da água no sistema de abastecimento de Belém. Durante o período de monitoramento foram determinados os indicadores cloro residual livre, turbidez, cor aparente, pH, fluoreto, ferro total, coliformes totais e E.coli. Foram realizadas coletas e análises em 46 pontos da zona central de abastecimento de Belém, compreendendo estações de tratamento, descida dos reservatórios dos setores e na rede de abastecimento. Cada conjunto de dados recebeu tratamento estatístico descritivo, remoção de outliers e passou pelo teste de Kruskal Wallis para verificar diferenças significativas entre indicadores de diferentes setores de abastecimento. Foi verificado que das 3680 determinações, 706 apresentaram não conformidades com a portaria 2914 (BRASIL, 2011), dentre os quais 582 foram na rede de abastecimento, 92 nas descidas dos reservatórios dos setores e 32 nas estações de tratamento. A metodologia FMEA foi aplicada a todos os indicadores analisados, e os pontos divididos em três grupos: REDE, DRS e ETA’s. Para o grupo REDE foram identificados 18 pontos de risco moderado e 18 pontos de risco alto. Para o grupo DRS e ETA’s todos os pontos foram de risco moderado. Nesta pesquisa não houve ocorrência de risco desprezível e crítico. Os indicadores fluoreto, coliformes totais e E.coli foram os mais influentes, cada um respondendo por aproximadamente 15% na ponderação de riscos. Contudo, o indicador fluoreto contribuiu para elevar a categoria dos riscos, pois apresentou 100% de não conformidades com a portaria 635 (BRASIL, 1975) em todos os pontos analisados. Após a categorização de risco, foram elaborados dois mapas, um de pontos e outro de isolinhas, representando os riscos referentes à qualidade da água para cada um dos pontos estudados. O mapa de isolinhas foi o que melhor representou o risco, pois apresentou maior abrangência de informações. / This study aims to use the risk assessment approach FMEA as control and safety methodology of water quality in Belém supply system. During the monitoring period were determined indicators free residual chlorine, turbidity, apparent color, pH, fluoride, total iron, total coliforms and E. coli. Collections and analyzes were performed in 46 points of Belém supplies central zone, including water treatment plants, reservoirs drop in the sectors and in the supply network. Each set of data received descriptive statistical analysis, outlier removal and passed the Kruskal Wallis test to determine significant differences between indicators of different supply sectors. It was found that the 3680 measurements, 706 showed no compliance with potability standards (BRASIL, 2011), of which 582 were in the supply network, 92 on the reservoirs drop in the sectors and 32 at treatment plants. The FMEA methodology was applied to all the analyzed indicators, and the points were divided into three groups: REDE, DRS and ETA’s. For the REDE group were identified 18 points of moderate risk and 18 points high risk. For the DRS group and ETA’s all the points were moderate risk. In this research there was no occurrence of despicable risk and critical. The indicators fluoride, total coliforms and E. coli were the most influential, accounting for approximately 15% in the risk weights. However, fluoride indicator contributes to increase the category of risk, because it showed 100% nonconformities with the fluor standards (BRASIL, 1975) in every point. After the categorization of risk, were prepared two maps, one with points and other with contours, representing the risks related to the quality of water for each one of the studied points. The contoured map was best represented the risk, as it presented more comprehensive information.
12

Vazamentos na rede de distribuição de água: impactos no faturamento e no consumo de energia elétrica do 3° setor de abastecimento de água da região metropolitana de Belém

CARMO, Félix Junior Justino do 18 June 2009 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-03-16T12:31:06Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_VazamentosRedeDistribuicao.pdf: 2520024 bytes, checksum: f93c7c454c7c83dce7845ec27160a8d5 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-20T11:48:58Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_VazamentosRedeDistribuicao.pdf: 2520024 bytes, checksum: f93c7c454c7c83dce7845ec27160a8d5 (MD5) / Made available in DSpace on 2017-03-20T11:48:58Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_VazamentosRedeDistribuicao.pdf: 2520024 bytes, checksum: f93c7c454c7c83dce7845ec27160a8d5 (MD5) Previous issue date: 2009-06-18 / Análise da estimativa de perdas de faturamento e de energia elétrica em decorrência de vazamento na rede de distribuição de água do 3º setor, gerenciado pela Companhia de Saneamento do Pará(COSANPA) na Região Metropolitana de Belém (RMB). A pesquisa foi realizada em 5(cinco) fases. Na fase 1 foi identificado o mês com maior ocorrência de vazamento no período de maio 2006 a abril de 2007, para detalhamento dessas ocorrências(local, diâmetro da rede e tempo de ocorrência de cada vazamento) na fase 2. Em seguida foram estimadas as vazões(fase 3) e os volumes perdidos(fase 4) na rede de distribuição de água do 3º setor. Finalmente na fase 5 foram estimadas as perdas de faturamento e de energia elétrica. Os resultados obtidos demonstram a necessidade de implantação de um programa de redução de perdas na rede de distribuição de água do 3º setor. O maior volume de água perdido ocorreu no mês de novembro de 2006, ocasionando perdas de faturamento de R$ 20.906,32 correspondente ao volume de 14.933,08 m3 e de energia elétrica no valor de R$ 477,80 corresponde a 2.389,93kWh. Com o trabalho foi possível constatar que os vazamentos na rede de distribuição do 3º setor prejudicam o desempenho do sistema e a receita da empresa. / Analysis of the estimate of losses billing of electric energy due the leak in the net of water distribution of the 3rd sector, managed by the Companhia de Saneamento do Pará (COSANPA) in the metropolitan region of Belém (RMB). The search was held done in 5 (five) stages. In the stage 1 was identified the month with major occurrence of leak in the period of May 2006 at Abril 2007, for detailing of the occurrences (local, diameter of the net and occurrence time of each leak) in the second phase. After it was estimated the flow (phase 3) and the volume lost (phase 4) in the net of water distribution of the 3rd sector. Finally in the phase 5 was estimated the losses of billing and electric energy. The results obtained show the necessities of deployment of a programme of reduction of losses in the net of water distribution of the 3rd sector. The greater volume of lost water occurred in the month of November 2006, causing loss of turnover of R$ 20.906,32 corresponding to the volume of 14.933,08 m3 and the electric energy on the value of R$477,80 correspond at 2.389,93kWh. With the work was possible see that the leaks in the net of water distribution of the 3rd sector damage the system performance and the revenue of the company.