• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Suivi de l'évapotranspiration des cultures irriguées du Sud de la Méditerranée par télédétection multi-capteurs et modélisation globale / Monitoring of evapotranspiration over irrigated crops in the South Mediterranean region using multi-sensor remote sensing observations and global modeling

Diarra, Alhousseine 20 December 2017 (has links)
Avec la pression croissante sur les ressources en eau accentuée par la menace des changementsglobaux, l'agriculture irriguée, surtout dans les régions semi-arides, se trouve confrontée à denouvelles exigences. Une gestion optimale des ressources en eau est indispensable dans les périmètresirrigués afin d'éviter à la fois l'irrigation excessive et le stress hydrique dommageable aux cultures.Dans ce contexte, proposer un outil simple, parcimonieux et robuste, facile à mettre en placepermettant de suivre le besoin réel en eau des cultures, à différentes échelles spatio-temporelles,permettrait d’apporter un indicateur tangible quant à l’efficience de l’irrigation dans les périmètresirrigués. Ce travail de thèse a pour objectif d’évaluer et d’adapter plusieurs outils de suivi del’évapotranspiration des cultures irriguées de l’échelle parcellaire à l’échelle régionale par l’utilisationde la télédétection multi-capteurs et multi-résolution. Notre zone d’étude est le bassin versant duTensift au Maroc, objet d’étude du LMI TREMA (Jarlan et al., 2015) et support de l’observatoireTensift. Nous avons identifié 3 outils : un modèle de bilan d’énergie de surface (TSEB ; Norman et al.,1995) piloté par une observation de température radiométrique qui renseigne indirectement sur l’étathydrique de surface ; l’approche à coefficient cultural double de la FAO-56 (Allen et al., 1998) quiprédit l’état hydrique de surface par la résolution d’un bilan hydrique mais nécessite en contre-partiede connaître précisément les apports d’eau, grandeur très incertaine sur les périmètres irrigués àl’échelle parcellaire ; la modélisation globale qui, par opposition aux deux autres, est une approcheautonome ne nécessitant aucun forçage externe. Dans un premier temps, la confrontation dessimulations du modèle TSEB à un ensemble de mesures expérimentales recueillies à l’échelleparcellaire durant 2 saisons agricoles ainsi qu’à l’approche FAO-56 préalablement calibrée sur lesprincipales cultures de notre région d’étude sur la base de travaux antérieurs a permis de montrer que :- le modèle TSEB est très robuste et offre des performances acceptables pour la prédiction del’évapotranspiration (RMSE < 1mm/jour sur 4 sites lors de deux saisons agricoles) ; - les bonnescapacités de cet outil pour la détection de stress hydrique ; - une bonne aptitude également àpartitionner l’évapotranspiration entre évaporation du sol et transpiration de la plante. Dans un 2èmetemps, nous avons évalué les capacités prédictives d’un modèle global que nous avons développé surla base d’une série temporelle d’évapotranspiration observée sur le terrain. La modélisation globale estbasée sur la théorie des systèmes dynamique non-linéaire. Si elle ne possède pas les capacitésexplicatives des modèles mécanistes évoqués ci-dessus, peut être une bonne alternative pour laprévision de l’évapotranspiration. L’analyse de l’horizon de prévisibilité du modèle global que nousavons obtenu montre un intérêt limité pour les agriculteurs ou les gestionnaires puisque cet horizonn’excède pas 3h. Néanmoins, cette approche, très originale dans ce contexte, reste particulièrementséduisante et ouvre plusieurs perspectives. Enfin, nous avons développé un prototype « tout satellite »,basé sur le modèle TSEB et qui utilise uniquement les produits gratuits MODIS et les ré-analysesERA-Interim, pour le suivi spatialisée et à long terme de la consommation en eau des cultures dans lebassin versant du Tensift. Après une évaluation des forçages ERA-Interim, nous avons évalué laperformance du prototype par (1) confrontation des prédictions des composantes du bilan d’énergieaux données expérimentales de l’observation Tensift et (2) confrontation de la consommationmensuelle prédite au niveau des principaux périmètres irrigués de la région aux apports d’eaumensuels fournis par l’office régional qui gère ces périmètres... / With the increasing pressure on water resources accentuated by the climate change threat, irrigated agriculture, especially in semi-arid zone, faced more challenges. Optimal management of water resources is essential in irrigated areas in order to avoid both excessive irrigation and water stress that is harmful to the growth of crops. In this context, proposing a simple, parsimonious and robust, easyto- use tool for monitoring the crop water requirement at different spatial and temporal scales would provide a tangible indicator of irrigation efficiency over irrigated perimeters. This thesis aims to evaluate and adapt several tools for monitoring the evapotranspiration of irrigated crops from the plot scale to the regional scale through the use of multi-sensor and multi-resolution remote sensing observations. Our study area is the Tensift watershed in Morocco, studied by LMI TREMA (Jarlan et al., 2015) and supported by the Tensift observatory. We identified 3 tools: a surface energy balance model (TSEB; Norman et al., 1995) driven by a radiometric temperature observation that provides indirect information on surface water status; the FAO-56 dual crop coefficient approach predicts the hydric status by computing the water balance but requires the know precisely the water input, very difficult to obtain on the plot scale of irrigated perimeters ; global modeling which, as opposed to the first two, is an autonomous approach requiring no external forcing. Firstly, the comparison of the TSEB model simulations with a set of experimental measurements collected on a plot scale during 2 consecutive agricultural seasons and with the results of the calibrated FAO-56 dual crop coefficient approach has shown that : - the TSEB model is very robust and offers acceptable performance for the prediction of evapotranspiration (RMSE <1mm / day during the two agricultural seasons); - a good capabilities of TSEB model for detection water stress; - a good ability also to partition the evapotranspiration between evaporation of the soil and transpiration of the plant. In the second step, we evaluated the predictive capacities of a global model that we developed on the basis of a time series of evapotranspiration observed in the field. Global modeling is based on the theory of the nonlinear dynamic systems theory. If it does not have the explanatory capabilities of the mechanistic models mentioned above, it may be a good alternative for predicting evapotranspiration. The analysis of the horizon of predictability of the global model that we obtained shows a limited interest for the farmers or the managers since this horizon does not exceed 3h. Nevertheless, this approach, very original in this context, remains particularly attractive and opens perspectives. Finally, we have developed a prototype, based on the TSEB model and using only MODIS free products and ERAInterim reanalyses, for monitoring evapotranspiration at Tensift watershed scale and over long periods. After an evaluation of the ERA-Interim products, we evaluated the prototype performance by (1) comparing the predictions of the energy balance components to the experimental data from Tensift observatory and (2) comparing the predicted monthly consumption at the main irrigated perimeters of the region with monthly water supplies provided by the regional office which manages these perimeters. Thus, there is a strong overestimation (almost a factor of 2) of the water consumed compared to the inflow of water, which could be related to the high number of boreholes in the region. This work and the tools developed opens perspectives for piloting and managing agricultural water in semi-arid regions.
2

Μελέτη και κλινική εφαρμογή δεσμών ηλεκτρονίων για ολικού δέρματος ακτινοβόληση στην ακτινοθεραπεία / Study and clinical application of electron beams for total skin irradiation in radiotherapy (TSEB)

Διαμαντόπουλος, Στέφανος Α. 20 September 2010 (has links)
Η ολοσωματική ακτινοβόληση με δέσμες ηλεκτρονίων (total skin electron beam treatment-TSEB) θεωρείται διεθνώς ως η θεραπεία εκλογής για το δερματικό λέμφωμα κυττάρων-Τ, είτε σαν θεραπευτική είτε σαν παρηγορητική αγωγή. Σκοπός της είναι να κατανείμει την συνολική δόση σε όλο το δέρμα του ασθενούς χωρίς να επιβαρύνει τα όργανα κάτω από αυτό. Αυτή η ανάγκη για επιφανειακή ακτινοβόληση καθιστά τα ηλεκτρόνια ως την κατάλληλη κλινική δέσμη. Στη μονάδα ακτινοθεραπείας του Π.Γ.Ν. «Αττικόν», μετά από διάφορες μετρήσεις και δοκιμές τεχνικών TSEB (Παράρτημα), επιλέχθηκε ως θέση θεραπείας του ασθενούς η όρθια με δύο δέσμες υπό γωνία, όπως καθορίζει και η τεχνική “Stanford”. Για την τεχνική αυτή χρησιμοποιείται o γραμμικός επιταχυντής Clinac 2100C της VARIAN με δυνατότητα παραγωγής δεσμών ηλεκτρονίων 6 MeV σε υψηλό ρυθμό δόσης. Η συγκεκριμένη προεπιλογή του μηχανήματος επιτρέπει στα διαφράγματα να ανοίξουν σε ένα εύρος 36cm x 36cm χωρίς τη χρήση κώνου. H απόσταση πηγής-δέρματος (SSD) τέθηκε ίση με 380cm, με το gantry του γραμμικού να σχηματίζει δύο γωνίες ±17,5ο από την οριζόντια θέση του (270ο). Η διάταξη αυτή εξασφαλίζει την δημιουργία ενός μεγάλου και ομοιογενούς πεδίου (200cm x 80cm στην απόσταση θεραπείας). Για τη μείωση της ονομαστικής ενέργειας της δέσμης στα 3 MeV άρα και της διεισδυτικότητάς της, καθώς και για την επίτευξη των επιθυμητών διαστάσεων του πεδίου, ένα φύλλο plexiglas (PMMA) πάχους 0,5cm παρεμβάλλεται μεταξύ της κεφαλής του γραμμικού επιταχυντή και του ασθενούς σε απόσταση 30cm από το επίπεδο θεραπείας. Ο ασθενής περιστρέφεται ανά 60ο διαδοχικά για να καλυφθεί όλη του η επιφάνεια ομοιόμορφα, ακτινοβολούμενος συνολικά σε έξι θέσεις. Για τον ακριβή καθορισμό των συνθηκών θεραπείας, πραγματοποιήθηκαν μετρήσεις PDD και Profile των δεσμών με θαλάμους ιονισμού παραλλήλων πλακών σε phantom στερεάς κατάστασης. )οσιμετρική επιβεβαίωση της κατανομής της δόσης στο δέρμα πραγματοποιήθηκε με δοσίμετρα θερμοφωταύγειας (TLD) πάνω σε ανθρωπομορφικό phantom. Τα αποτελέσματα σε αυτές τις συνθήκες έδειξαν μια ομοιογένεια του συνολικού πεδίου στο επίπεδο θεραπείας της τάξης του ± 2% στον διαμήκη άξονα ενώ στον οριζόντιο ±5%. Το βάθος zmax της κάθε επιμέρους δέσμης είναι 0,7gr/cm2 ενώ η συνεισφορά των παραγόμενων ακτίνων-Χ (λόγω φαινομένου πεδήσεως) στην συνολική δόση που παίρνει ο ασθενής από τη θεραπεία είναι 0,3 %. Η ενέργεια της δέσμης στο επίπεδο θεραπείας είναι Εο=3,34 MeV. Τα παραπάνω αποτελέσματα μας οδηγούν στο συμπέρασμα ότι η θεραπεία TSEB μπορεί να εφαρμοστεί με ασφάλεια στο ακτινοθεραπευτικό τμήμα του Π.Γ.Ν «Αττικόν». Ο υψηλός ρυθμός δόσης εξασφαλίζει μικρότερο χρόνο θεραπείας. Οι περιοχές που υποδοσιάζονται καθ’ όλη τη διάρκεια της θεραπείας μπορούν να προσδιοριστούν για κάθε ασθενή με in vivo δοσιμετρία (TLD) και θα επανακτινοβολούνται με συμπληρωματικά (boost) πεδία. / -

Page generated in 0.0193 seconds