• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • Tagged with
  • 12
  • 12
  • 10
  • 8
  • 5
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estimativa da infiltração e do afluxo devidos à precipitação na rede de esgoto sanitário em município de pequeno porte.

Festi, Aparecido Vanderlei 28 February 2006 (has links)
Made available in DSpace on 2016-06-02T20:00:16Z (GMT). No. of bitstreams: 1 DissAVF.pdf: 3142723 bytes, checksum: d32fec625d6a407ea812f6bfdadc0c46 (MD5) Previous issue date: 2006-02-28 / The main purpose of this work was to identify and to estimate the rainfall derived infiltration and inflow (IADP) into the sewer in a small city and to do an analysis of their influence on this collection system. This work was composed by field measurements on the sewage flowrate output and volume arriving to the Sewage Pumping Plant Station, simultaneously to the collection and measurement of rainfall on the corresponding same urban watershed area of the Borborema, in São Paulo State. The existing methodologies were divided in the follow steps: choosing and characterization of the working field; data collection of the sewage volume and flowrate; collection of the rainfall data; choosing and characterization of the data collected; employment of existing models and methodologies useful to the present available data, in order to derive the underground water infiltration rate and the overflow occurring in the sewage colletion network. The volumetric and percentile IADP were quantified. The constant unitary rate (TUC) was also estimated, by several ways. The results allowed obtaining mathematical formulations to derive the IADP and TUC of the Borborema s sewage network. Such mathematical formulations are suitable to be applied in urban areas of cities of a similar to that of Borborema. It was estimated that the IADP can generate flowrates 2,5 times greater than the sewage flows in dry weather and infiltration rates in the sewage network similar to those adopted for system design. The work allowed to estimate how complex are the infiltration and inflow of stormwater in the sewer network. The methodologies applied were quite simple and may be easily applied in other cities. / O objetivo precípuo desta pesquisa foi identificar e estimar a infiltração e o afluxo devidos da precipitação (IADP) na rede de esgoto sanitário em município de pequeno porte e efetuar uma análise da sua influência no sistema de esgotamento sanitário. Este trabalho foi realizado através da medição em campo de vazão e volume de esgoto sanitário a montante da EEE Estação Elevatória de Esgoto, simultaneamente com a coleta e medição da chuva precipitada na correspondente área urbanizada da bacia hidrográfica da cidade de Borborema/SP. As metodologias empregadas foram divididas nas seguintes fases: escolha e caracterização do local da pesquisa; coleta de dados de vazão e volume dos efluentes de esgotos sanitários e coleta de dados de precipitação de chuva no local do estudo; seleção e caracterização dos dados coletados; aplicação das metodologias e modelagens existentes possíveis de aplicar em função dos dados disponíveis, para a obtenção da taxa de infiltração das águas subterrâneas e da sobrecarga na rede de esgoto sanitário. Quantificou-se o IADP volumétrica e percentualmente. Calculou-se também a taxa unitária constante (TUC), sob diferentes formatos. Os resultados desta pesquisa permitiram a obtenção de equações matemáticas para avaliação da IADP e da TUC do sistema de esgoto da cidade de Borborema que possivelmente poderão ser aplicadas em áreas urbanizadas de outras cidades do mesmo porte. Estimou-se que a IADP pode gerar volumes 2,5 vezes maiores que o volume de esgotos em tempo seco, bem como taxas de infiltração na rede coletora próximas àquelas adotadas para cálculo da rede. O trabalho possibilitou avaliar quão complexos são a infiltração e o afluxo de águas de chuva na rede de esgoto sanitário. Os métodos empregados, tanto de coleta quanto de modelagem, foram muito simples e podem ser aplicados em outras cidades com certa facilidade.
12

Infiltração da água em latossolo vermelho distroférrico utilizando infiltrômetros de cilíndro único / Water infiltration in dystropheric red latosol using single cylinder infiltrometers

Frigo, Jianice Pires 19 April 2017 (has links)
Submitted by Neusa Fagundes (neusa.fagundes@unioeste.br) on 2017-09-05T12:35:02Z No. of bitstreams: 1 Jianice_Frigo2017.pdf: 1119086 bytes, checksum: 87f159fe89d2840c9e6c7be155e2a65c (MD5) / Made available in DSpace on 2017-09-05T12:35:02Z (GMT). No. of bitstreams: 1 Jianice_Frigo2017.pdf: 1119086 bytes, checksum: 87f159fe89d2840c9e6c7be155e2a65c (MD5) Previous issue date: 2017-04-19 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The infiltration process understanding and its relationship with soil properties is essential for the efficient management of soil and water. Thus, this paper aimed at evaluating water infiltration in an area of Oxisol, using single ring infiltrometers with different diameters. In addition, it also aimed at comparing the performance of 7 cm (A7) and 15 cm (A15) cylinders, matching soil moisture and bulk density to water infiltration and evaluating spatial distribution of infiltration. For this purpose, 24 data points were evaluated, placed in 8 plots of a circular area prepared for permaculture cropping, named as Mandala. Shewhart graphs and process capability index were used to compare cylinders and the inverse of distance square for data interpolation. It was observed that the average stable infiltration rate, determined with A7 cylinder, was 196.79 mm h-1 and with A15 cylinder was 187.30 mm h-1, consequently, there was a difference of 5.6%. The process capacity was estimated at 0.61 for A7 and 1.62 for A15, considered adequate for A15 and inadequate for A7 cylinder. Thus, it was concluded that the infiltration rates that were stabilized and determined by the cylinders were compatible with the rates determined by other methods in other papers. Regarding the performance of single-ring infiltrometers, it is concluded that, although both cylinders presented controlled processes, and did not differ statistically, cylinder A15 presented less variability on data, and may be considered adequate due to its process capability index. / O entendimento do processo de infiltração e das suas relações com as propriedades do solo é fundamental para o eficiente manejo do solo e da água. Assim, este trabalho teve como objetivo avaliar a infiltração de água em uma área de latossolo vermelho, para tanto, foram utilizados infiltrômetros de único cilindro, de diferentes diâmetros. Além disso, objetivou-se comparar o desempenho desses cilindros de 7 (A7) e de 15 cm (A15), relacionar a umidade e a densidade aparente do solo à infiltração da água e avaliar a distribuição espacial da infiltração. Foram avaliados 24 pontos de coleta de dados, alocados em 8 parcelas de um talhão circular preparado para plantio em regime de permacultura, denominado mandala. Gráficos de Shewhart e o índice de capacidade de processo foram utilizados para a comparação entre os cilindros e inverso do quadrado da distância para interpolação de dados. Verificou-se que a taxa de infiltração estável média, determinada com o cilindro A7, foi de 196,79 mm h-1 e com o cilindro A15 foi de 187,30 mm h-1, cuja diferença foi de 5,6 %. A capacidade de processo foi estimada em 0,61 para A7 e 1,62 para A15, a qual foi considerada adequada para o cilindro A15, porém inadequada para cilindro A7. Desta forma, neste trabalho, concluiu-se que as taxas de infiltração estáveis e determinadas pelos cilindros foram compatíveis com as taxas determinadas por outros métodos em outros trabalhos. Em relação ao desempenho dos infiltrômetros de cilindros únicos, conclui-se que, embora ambos os cilindros tenham apresentado processos controlados e não tenham diferido estatisticamente, o cilindro A15 apresentou menos variabilidade dos dados, e pode ser considerado adequado em função do seu índice de capacidade de processo.

Page generated in 0.0723 seconds