Spelling suggestions: "subject:"telhado verde extensive"" "subject:"telhado verde extensiva""
1 |
Telhado verde extensivo em pré-moldado de concreto EVA (Acetato Etil Vinila)Mendonça, Tatyane Nadja Martins de 31 March 2015 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2016-01-05T13:09:41Z
No. of bitstreams: 1
arquivototal.pdf: 9544233 bytes, checksum: 67a4854cf3a43adf8a531c196cbfb7d2 (MD5) / Made available in DSpace on 2016-01-05T13:09:41Z (GMT). No. of bitstreams: 1
arquivototal.pdf: 9544233 bytes, checksum: 67a4854cf3a43adf8a531c196cbfb7d2 (MD5)
Previous issue date: 2015-03-31 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Green areas of the city are occupied increasingly by buildings and waterproofing floors, and this implies lower quality in urban environments, since the effect of vegetation in these areas goes far beyond the landscape, it is responsible for purification air, moisture maintenance, thermal equilibrium, among other benefits. Given the lack of green space, and knowing that the roofs are in a significant percentage of impermeable areas, it is defended here the use of vegetated roofs, in order to increase the green of the cities and enjoy its benefits. An extensive green roof modular technology developed on a pre-molded cement, which uses the residue of footwear (EVA) was investigated here, from its conception to its evaluation. In the methodological procedures the following milestones have been met: module design (called block TEVA) and from mold to manufacture, experimental moldings with definition of proportions among the cementitious composite materials, green roof systems simulations, the modular system installation in real scale for plant development monitoring, and prototype scale to evaluate the thermal behavior and in four other types of coverage (exposed slab, ceramic roof, fiber cement roof, green roof with concrete blocks). Comparing the same prototypes, was also made an assessment of rainwater drained by different types of roof coverings. Based on the results it can be concluded that the module designed to be sometimes vegetated, sometimes be used as floor, has geometry, mechanical strength, lightness and water permeability suitable for the type of green roof proposed. The modules also allowed a good development of vegetation. A thermal evaluation confirmed that the green roof with TEVA modular blocks provided a better thermal balance and reduced indoor air temperature when compared with other types of coverage. The analysis of rainwater drained by different systems, modular green roof with TEVA block was also the one with the best performance, significantly reducing the volume of runoff. / As áreas verdes da cidade estão sendo ocupadas cada vez mais pelas edificações e impermeabilizações de pavimentos e isto implica em menor qualidade nos ambientes urbanos, uma vez que o efeito da vegetação nesses espaços vai muito além do paisagístico, sendo responsável pela purificação do ar, manutenção da umidade, equilíbrio térmico, entre outros benefícios. Diante da falta do espaço para o verde, e sabendo que os telhados constituem-se em uma porcentagem significativa das áreas impermeabilizadas, defende-se aqui a utilização dos telhados vegetados a fim de se aumentar o verde das cidades e aproveitar os seus benefícios. Uma tecnologia modular de telhado verde extensivo desenvolvida à base de um pré-moldado cimentício, que utiliza resíduo da indústria de calçado (EVA), foi investigada aqui desde sua concepção até a sua avaliação. Nos procedimentos metodológicos foram cumpridas as seguintes etapas: concepção do módulo (denominado bloco TEVA) e do molde para sua fabricação, moldagens experimentais com definição das proporções entre os materiais do compósito cimentício, simulações de sistemas de telhados verdes, instalação do sistema modular em escala real para acompanhamento do desenvolvimento vegetal, e em escala de protótipo para avaliação do comportamento térmico, comparado com quatro outros tipos de coberturas (laje exposta, telhado cerâmico, telhado de fibrocimento, telhado verde com blocos de concreto). Comparando os mesmos protótipos, também foi feita uma avaliação da água pluvial drenada pelos diferentes tipos de coberturas. Com base nos resultados pode-se concluir que o módulo idealizado para ora ser vegetado, ora ser utilizado como piso, tem geometria, resistência mecânica, leveza e permeabilidade à água satisfatórios para o tipo de telhado verde proposto. Os módulos também permitiram um bom desenvolvimento da vegetação. A avaliação térmica confirmou que o telhado verde modular com blocos TEVA promoveu um maior equilíbrio térmico e reduziu a temperatura do ar interno, quando comparado com os outros tipos de coberturas. Quanto à análise da água pluvial drenada por diferentes sistemas, o telhado verde modular com bloco TEVA também foi o que apresentou o melhor desempenho, diminuindo significativamente o volume da água escoada.
|
2 |
Avaliação do potencial de uso de três espécies vegetais como cobertura leve de telhados em edificações / Evaluation of the potential use of three plant species as light cover on roof buildingsBeatrice, Caio Cury 12 August 2011 (has links)
O uso telhados verdes oferece benefícios como: moderação dos valores da temperatura no interior de edificações e contenção temporária da água de chuva, limpeza de poluentes atmosféricos, além de favorecer aspectos ecológicos. Poucos estudos científicos foram realizados no sentido de adaptar as técnicas contemporâneas e a indicação de espécies apropriadas ao sistema de telhado verde extensivo, originadas de regiões de clima temperado para as condições dos climas tropicais. O objetivo desta pesquisa foi identificar espécies com potencial de uso em telhado verde em sistema extensivo, quantificando a reação das plantas à variação de diferentes profundidades de substrato, em situações limitadas de manutenção, no aspecto de irrigação e nutrição do solo. Procurou-se também registrar o comportamento térmico do solo, a fim de verificar a influência da vegetação no aquecimento da parte inferior do solo em relação a distintas profundidades de substrato. Os vegetais foram plantados em setembro de 2009 aplicados em 27 plataformas de teste. Foram cultivadas três espécies de plantas das famílias Fabaceae (Arachis repens Handro), Poaceae (Paspalum notatum Flügge) e Ruscacea (Ophiopogon japonicus (L.F. Ker Gawl)), sob três tratamentos de profundidades de substrato, 0.05, 0.075 e 0.10 m. Quantificou-se mensalmente a porcentagem de cobertura vegetal, crescimento vertical e de sobrevivência, com encerramento ao final de um ciclo anual. O comportamento térmico dos solos nos diferentes tratamentos foi registrado automaticamente por meio de sensores. Os resultados indicaram a espécie Ophiopogon japonicus, em solos de 0.10 m, como a que apresentou o melhor desempenho entre as três examinadas, seguida por Paspalum notatum. Todas as espécies cultivadas em solos de 0.10 m apresentaram resultados satisfatórios quanto a cobertura do solo, crescimento vertical e sobrevivência, em relação ao cultivo em profundidades menores de substrato. O cultivo em menor profundidade de solo (0.05 m) revelou baixo valor de sobrevivência para todas as espécies durante o período de poucas chuvas. O crescimento vertical foi satisfatório para todas as espécies analisadas, dispensando manutenção com poda regular. Os resultados de comportamento térmico indicaram melhor desempenho de solos à profundidade de 0.10 m, independente do tipo de planta cultivado. Concluiu-se que solos de menor espessura são mais dependentes de cobertura vegetal para minimizar seu aquecimento e que os solos de maior espessura o fazem com menor dependência da vegetação. O melhor desempenho térmico foi observado em solos de 0.10 m, em relação às profundidades menores, embora não variasse seu comportamento térmico significativamente com o cultivo das três diferentes espécies de plantas, referente aos valores de cobertura atingidos neste experimento. / The uses of green roofs provide benefits such as moderation of the temperature inside buildings, temporary containment of rainwater, cleaning of air pollutants, in addition to promoting ecological aspects. Few scientific studies have been conducted to adapt contemporary techniques and indication of appropriate species for extensive green roof system, originated from temperate regions to the conditions of tropical climates. The objective of this research was to identify species with potential for use in green roof in the extensive system, quantifying the response of plants to variation of different depths of substrate, in limited situations of maintenance in respect of irrigation and soil nutrition. Was searched register the thermal behavior of soil in order to determine the influence of vegetation on the warming of the lower soil depths for different substrates. The plants were planted in september 2009, applied in 27 platforms. There were three species of cultivated plants of the families Fabaceae (Arachis repens Handro), Poaceae (Paspalum notatum Flügge) and Ruscacea (Ophiopogon japonicus (L.F.) Ker Gawl) under three treatments of substrate depths, 0.05, 0.075 and 0.10 m. Was quantified the percentage of monthly vegetation cover, vertical growth and survival, with closing at the end of an annual cycle. The thermal behavior of soils under different treatments was recorded using sensors. The results indicated that Ophiopogon japonicus in 0.10 m soils, showed the best performance among the three examined. All species grown in 0.10 m of soils had been satisfactory results of soil cover, vertical growth and survival in relation to culture in shallower substrate. The species Arachis repens showed the highest sensitivity to the depth and water stress during the autumn and winter, requiring more necessity of maintenance. Cultivation in shallower soil (0.05 m) showed low survival value for all species during the short rains. The vertical growth was satisfactory for all species analyzed, of which the greatest height reached was Ophiopogon japonicus without requiring regular maintenance pruning. The results indicated better performance thermal behavior of soil to a depth of 0.10 m, regardless of the type of plant grown. It was concluded that soils of lesser thickness are dependent on vegetation cover to minimize your heating, and the soils with more thickness are less dependence on the vegetation. The best thermal performance was observed in soils of 0.10 m compared to shallower depths, but did not vary significantly its thermal behavior with the cultivation of three different species of plants, referring to amounts of coverage achieved in this experiment.
|
3 |
Avaliação do potencial de uso de três espécies vegetais como cobertura leve de telhados em edificações / Evaluation of the potential use of three plant species as light cover on roof buildingsCaio Cury Beatrice 12 August 2011 (has links)
O uso telhados verdes oferece benefícios como: moderação dos valores da temperatura no interior de edificações e contenção temporária da água de chuva, limpeza de poluentes atmosféricos, além de favorecer aspectos ecológicos. Poucos estudos científicos foram realizados no sentido de adaptar as técnicas contemporâneas e a indicação de espécies apropriadas ao sistema de telhado verde extensivo, originadas de regiões de clima temperado para as condições dos climas tropicais. O objetivo desta pesquisa foi identificar espécies com potencial de uso em telhado verde em sistema extensivo, quantificando a reação das plantas à variação de diferentes profundidades de substrato, em situações limitadas de manutenção, no aspecto de irrigação e nutrição do solo. Procurou-se também registrar o comportamento térmico do solo, a fim de verificar a influência da vegetação no aquecimento da parte inferior do solo em relação a distintas profundidades de substrato. Os vegetais foram plantados em setembro de 2009 aplicados em 27 plataformas de teste. Foram cultivadas três espécies de plantas das famílias Fabaceae (Arachis repens Handro), Poaceae (Paspalum notatum Flügge) e Ruscacea (Ophiopogon japonicus (L.F. Ker Gawl)), sob três tratamentos de profundidades de substrato, 0.05, 0.075 e 0.10 m. Quantificou-se mensalmente a porcentagem de cobertura vegetal, crescimento vertical e de sobrevivência, com encerramento ao final de um ciclo anual. O comportamento térmico dos solos nos diferentes tratamentos foi registrado automaticamente por meio de sensores. Os resultados indicaram a espécie Ophiopogon japonicus, em solos de 0.10 m, como a que apresentou o melhor desempenho entre as três examinadas, seguida por Paspalum notatum. Todas as espécies cultivadas em solos de 0.10 m apresentaram resultados satisfatórios quanto a cobertura do solo, crescimento vertical e sobrevivência, em relação ao cultivo em profundidades menores de substrato. O cultivo em menor profundidade de solo (0.05 m) revelou baixo valor de sobrevivência para todas as espécies durante o período de poucas chuvas. O crescimento vertical foi satisfatório para todas as espécies analisadas, dispensando manutenção com poda regular. Os resultados de comportamento térmico indicaram melhor desempenho de solos à profundidade de 0.10 m, independente do tipo de planta cultivado. Concluiu-se que solos de menor espessura são mais dependentes de cobertura vegetal para minimizar seu aquecimento e que os solos de maior espessura o fazem com menor dependência da vegetação. O melhor desempenho térmico foi observado em solos de 0.10 m, em relação às profundidades menores, embora não variasse seu comportamento térmico significativamente com o cultivo das três diferentes espécies de plantas, referente aos valores de cobertura atingidos neste experimento. / The uses of green roofs provide benefits such as moderation of the temperature inside buildings, temporary containment of rainwater, cleaning of air pollutants, in addition to promoting ecological aspects. Few scientific studies have been conducted to adapt contemporary techniques and indication of appropriate species for extensive green roof system, originated from temperate regions to the conditions of tropical climates. The objective of this research was to identify species with potential for use in green roof in the extensive system, quantifying the response of plants to variation of different depths of substrate, in limited situations of maintenance in respect of irrigation and soil nutrition. Was searched register the thermal behavior of soil in order to determine the influence of vegetation on the warming of the lower soil depths for different substrates. The plants were planted in september 2009, applied in 27 platforms. There were three species of cultivated plants of the families Fabaceae (Arachis repens Handro), Poaceae (Paspalum notatum Flügge) and Ruscacea (Ophiopogon japonicus (L.F.) Ker Gawl) under three treatments of substrate depths, 0.05, 0.075 and 0.10 m. Was quantified the percentage of monthly vegetation cover, vertical growth and survival, with closing at the end of an annual cycle. The thermal behavior of soils under different treatments was recorded using sensors. The results indicated that Ophiopogon japonicus in 0.10 m soils, showed the best performance among the three examined. All species grown in 0.10 m of soils had been satisfactory results of soil cover, vertical growth and survival in relation to culture in shallower substrate. The species Arachis repens showed the highest sensitivity to the depth and water stress during the autumn and winter, requiring more necessity of maintenance. Cultivation in shallower soil (0.05 m) showed low survival value for all species during the short rains. The vertical growth was satisfactory for all species analyzed, of which the greatest height reached was Ophiopogon japonicus without requiring regular maintenance pruning. The results indicated better performance thermal behavior of soil to a depth of 0.10 m, regardless of the type of plant grown. It was concluded that soils of lesser thickness are dependent on vegetation cover to minimize your heating, and the soils with more thickness are less dependence on the vegetation. The best thermal performance was observed in soils of 0.10 m compared to shallower depths, but did not vary significantly its thermal behavior with the cultivation of three different species of plants, referring to amounts of coverage achieved in this experiment.
|
Page generated in 0.0805 seconds