• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Utveckling av simuleringsmodell i COMSOL för att undersöka temperaturökning hos foster vid ultraljudsexponering / Development of a Simulation Model in COMSOL to Examine Temperature Elevation in the Fetus During Ultrasound Exposure

Roempke Lindström, Sara, Wåhlgren, Moa January 2022 (has links)
Ett foster har inte samma blodflöde och resistans mot förändringar i sin miljö som en vuxen människa har och kan vid små temperaturförändringar orsakas skada i till exempel den utvecklande hjärnan. Vid ultraljudsundersökning finns bevisat en viss värmeökning, men det råder ovisshet kring hur stor denna skulle kunna bli under en längre tids exponering av ultraljud. Syftet med detta arbete var att undersöka värmeutvecklingen vid obstetriskt ultraljud genom att utforma en 3D-modell i mjukvarumiljön COMSOL Multiphysics version 6.0. En modell kan bidra med kunskap för att besluta kring om riskerna med temperaturökning hos foster till följd av ultraljud behöver studeras vidare. Resultaten av framtagen modellering visade på en mycket liten uppvärmningseffekt. Slutsatsen drogs att om modellen i 3D ska kunna göra trovärdiga beräkningar i programmet krävs en mer avancerad dator än vanligt, med betydligt större minneskapacitet. Vidare utveckling av modell i COMSOL bör göras i 2D, alternativt med en mer avancerad dator, för att få tillförlitliga resultat. / A fetus does not have the same blood perfusion and resistance to changes in its environment as an adult and small changes in temperature can cause irreversible damage for example to the fetal brain. Ultrasound examinations are proven to cause some heat gain but there are uncertainties regarding the amount of heat gain during a longer time of ultrasound exposure. The purpose of this study was to analyse the heat development during obstetric ultrasound by designing a 3D-model in the software environment COMSOL Multiphysics version 6.0. A model could contribute to knowledge in making an informed decision whether the risks of heating in a fetus because of ultrasound are necessary to study further. The results of the developed model showed a very small heating effect. The conclusion was made that if the model in 3D is to be able to make correct calculations in the programme it is required to use a more advanced computer than usual, with significantly greater memory capacity. Further development of a model in COMSOL should be made in 2D, or with a more advanced computer, to get reliable results.
2

Utvärdering av en billig ultraljudsmaskin med avseende på bildkvalitet och temperaturökning / Evaluation of a Cheap Ultrasound Machine with Respect to Image Quality and Temperature Increase

Dragunova, Yulia, Anderberg, Joakim January 2021 (has links)
Ultraljudsdiagnostik baseras på propagering av mekaniska vågor och används för att avbilda tvärsnitt av kroppen i realtid. Prestandan, med avseende på kontrast, upplösning och måttmätningar, av CONTEC CMS600B-3, en relativ billig maskin är av intresse. Hur volymen av en fantom, dess ytarea och frekvens på utskickade vågor påverkar uppvärmningen av vävnader är även av intresse. Det undersöktes med ultraljudsmaskinerna CONTEC CMS600B-3 och Philips Lumify för att få resultat som inte beror på endast en maskin.  Axiella upplösningen på CONTEC CMS600B-3 uppmättes med hjälp av ett gem till 0,61 mm och den laterala upplösningen till 1,27 mm med hjälp av ett snitt i cement. Maskinens måttmätningar hade en relativ avvikelse   beroende på mätning. Resultat för reflektionskoefficienten visade att ultraljudsmaskinen har en funktion som kompenserar för attenuering och förstärker signaler med låga amplituder.  Temperaturmätningarna undersöktes genom att skapa fantomer som efterliknar mänskliga vävnader med olika volymer och ytareor. En undersökning med ultraljudsmaskinerna visade att mer temperaturökning sker då ytarean ökas när volymen hålls konstant. Med avseende på säkerhet i temperaturökning, axiell upplösning och area/omkrets mått uppfyller CONTEC CMS600B-3 inte standarden och kan därmed inte användas inom sjukvården. / Diagnostics with ultrasound are based on propagation of mechanical waves and is used for imaging cross-section of the body in real-time. Performance, regarding contrast, resolution, and size measure, of CONTEC CMS600B-3, a relatively cheap machine is of interest. How volume of a phantom, its surface area, and frequency of the waves affects the heating of the tissues is also of interest. It was measured using ultrasound machines CONTEC CMS600B-3 and Philips Lumify to obtain results independent of the machine used.   The axial resolution of CONTEC CMS600B-3 was established with a paperclip to be 0.61 mm and the lateral resolution was measured to be 1.27 mm using concrete with a triangular slit. Measurements of the machine had a relative deviation was   depending on the measure. Results of the reflection coefficient indicated that CONTEC CMS600B-3 has a built-in function that compensates for loss of intensity due to attenuation and amplifies signals with lower amplitude to produce a B-mode image that the user can understand.  Temperature measurements were done on phantoms that mimic the human body with different volumes and surface areas. An investigation with ultrasound machines showed an increase in temperature with increased surface area as the volume is held constant. When looking at safety with temperature rise, axial resolution and area/circumference measurements, CONTEC CMS600B-3 does not meet the standard and therefore cannot be used in healthcare.
3

Evaluating Technical Lifetime of Radio Circuit Boards : by Measuring Degradation and Aging of Hold-up Capacitors / Utvärdering av teknisk livslängd för radiokretskort : Genom att mäta degradering och åldring av hold-up kondensatorer

Tellberg, Otto January 2023 (has links)
The aim of this thesis is to improve the knowledgebase regarding the technical lifetime of radio circuit boards. The purpose is to create opportunities to facilitate the design of products that live up to the customers' requirements and to Ericsson's sustainable responsibility goals. The problem at hand was to look for the average temperature that has contribiuted to the performance degradation of circuit boards used in the field. The method was to measure the performance degradation of capacitors used in a power distribution function on the circuit board and combining those values with the time the circuit board has been in operation, to derive the average operation temperature with the help of the Arrhenius equation. The radio circuit board used in the field showed signs of performance degradation that could be interpreted as having reached the end of its technical lifetime after being used for 31 800 hours (3,6 years) at an average temperature of 78 °C to 79 °C. For it to be possible to interpret the temperature results of the unit used in the field, the three parameters: measured performance degradation, time of operation and average temperature at that time, had to be collected. All three parameters are key when evaluating technical lifetime since they need to be interpreted in relation to each other. The temperature results exists in a thermodynamic system that includes the capacitors, circuit board, the temperature of the surrounding environment, and the global climate. The temperature results and the measured performance degradation is a consequence of how the radio was operated, which is linked to the desired performance it was designed for. The radio circuit boards are also designed to comply with customers' requirements and the requirements based in the companys's sustainability responsibility goals. It is likely that the desired performance of radios in the future needs to be balanced with the company's sustainability responisibility goals, and the temperatures created as an effect of climate change. / Målet med detta examensarbete var att öka kunskapen om radiokretskorts tekniska livslängd. Syftet var att skapa möjligheter att främja utveckling av produkter som möter kunders krav samt de krav som följer av Ericssons strategi för hållbarhet och ansvarsfullt företagande. Problemformuleringen består av att söka efter medeltemperaturen som har bidragit till den prestandadegradering som lett till att kretskort i fält nått slutet på sin tekniska livslängd. Metoden som användes för att kunna härleda medeltemperaturen under drift var att mäta prestandadegraderingen hos kondensatorer som används i en specifik kraftfördelningsfunktion på radiokretskort och kombinera dessa mätvärden med tiden kretskortet varit i drift. Tiden och temperaturen härleddes med hjälp av Arrhenius ekvation. Den radiokretskortsenhet som användes i fält kan tolkas ha nått slutet på sin tekniska livslängd efter 31 800 timmar (3,6 år) och under tiden i drift haft medeltemperaturen på ungefär 78 °C till 79 °C. För att det skulle vara möjligt att tolka temperaturresultatet för radiokretskortet som användes i fält behövde följande tre parameterar samlas in: uppmätt prestandadegradering, tiden som radiokretskortet varit i drift samt medeltemperaturen under driftstiden. Samtliga tre parameterar behöver analyseras i relation till varandra när den tekniska livslängden ska utvärderas. Temperaturresultatet existerar i ett termodynamiskt system som består av kondensatorerna, krestkortet, temperaturen i den omkringliggande miljön samt det globala klimatsystemet. Temperaturresultatet och den uppmätta prestandadegraderingen är en konsekvens av hur radion har använts och är länkat till den den prestanda radion är designad för. Radiokretskorten är också designade för att följa kundernas krav och de krav som följer av Ericssons strategi för hållbarhet och ansvarsfullt företagande. Det är sannolikt att den önskade prestandan hos radioprodukter i framtiden behöver balanseras med de krav som följer av Ericssons strategi för hållbart företagande samt de temperaturer som skapas som konsekvens av klimatförändringarna.

Page generated in 0.0563 seconds