• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação termográfica e recuperação funcional da locomoção após esmagamento do nervo ciático em ratos adultos

Sacharuk, Viviane Zechlinski January 2009 (has links)
Os nervos periféricos são freqüentemente lesionados por lesão mecânica direta, doenças metabólicas ou tumores. As lesões dos NPs resultam em perda parcial ou total das funções motoras, sensoriais e vegetativas no segmento corporal envolvido. Ratos machos adultos Wistar foram divididos em três grupos: controle (n=7), sham (n=25) e crush (n=25). Todos os grupos foram submetidos à avaliação termográfica, funcional e histológica. A ∆ T do grupo crush foi diferente do grupo controle no 1°, 3°e 7° dia pós-operatório, e do grupo sham no 1°, 3°e 28° dia pós-operatório (p0.05). No grupo crush, a recuperação funcional retornou ao aos valores normais entre a 3ª e 4ª semanas após a lesão, enquanto a análise morfológica do nervo mostrou uma regeneração incompleta na 4ª semana após a lesão. Este estudo é a primeira demonstração que a temperatura da pele é aumentada pela compressão do nervo ciático e esta mudança provavelmente não é correlacionada com a recuperação funcional.
2

Avaliação termográfica e recuperação funcional da locomoção após esmagamento do nervo ciático em ratos adultos

Sacharuk, Viviane Zechlinski January 2009 (has links)
Os nervos periféricos são freqüentemente lesionados por lesão mecânica direta, doenças metabólicas ou tumores. As lesões dos NPs resultam em perda parcial ou total das funções motoras, sensoriais e vegetativas no segmento corporal envolvido. Ratos machos adultos Wistar foram divididos em três grupos: controle (n=7), sham (n=25) e crush (n=25). Todos os grupos foram submetidos à avaliação termográfica, funcional e histológica. A ∆ T do grupo crush foi diferente do grupo controle no 1°, 3°e 7° dia pós-operatório, e do grupo sham no 1°, 3°e 28° dia pós-operatório (p0.05). No grupo crush, a recuperação funcional retornou ao aos valores normais entre a 3ª e 4ª semanas após a lesão, enquanto a análise morfológica do nervo mostrou uma regeneração incompleta na 4ª semana após a lesão. Este estudo é a primeira demonstração que a temperatura da pele é aumentada pela compressão do nervo ciático e esta mudança provavelmente não é correlacionada com a recuperação funcional.
3

Avaliação termográfica e recuperação funcional da locomoção após esmagamento do nervo ciático em ratos adultos

Sacharuk, Viviane Zechlinski January 2009 (has links)
Os nervos periféricos são freqüentemente lesionados por lesão mecânica direta, doenças metabólicas ou tumores. As lesões dos NPs resultam em perda parcial ou total das funções motoras, sensoriais e vegetativas no segmento corporal envolvido. Ratos machos adultos Wistar foram divididos em três grupos: controle (n=7), sham (n=25) e crush (n=25). Todos os grupos foram submetidos à avaliação termográfica, funcional e histológica. A ∆ T do grupo crush foi diferente do grupo controle no 1°, 3°e 7° dia pós-operatório, e do grupo sham no 1°, 3°e 28° dia pós-operatório (p0.05). No grupo crush, a recuperação funcional retornou ao aos valores normais entre a 3ª e 4ª semanas após a lesão, enquanto a análise morfológica do nervo mostrou uma regeneração incompleta na 4ª semana após a lesão. Este estudo é a primeira demonstração que a temperatura da pele é aumentada pela compressão do nervo ciático e esta mudança provavelmente não é correlacionada com a recuperação funcional.
4

Efeito do exercício muscular sobre temperatura e atividade elétrica dos músculos masseter e temporal

Gallo, Ana Kelly Garcia [UNESP] 13 November 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-11-13Bitstream added on 2014-06-13T18:35:14Z : No. of bitstreams: 1 gallo_akg_me_araca.pdf: 354042 bytes, checksum: 660f5112e78c8937509fef084e0acf8f (MD5) / O esforço muscular exige modificações metabólicas e uma adaptação, ou seja, uma necessidade maior de nutrientes e O2 para que seja realizada a contração muscular. O objetivo do presente estudo foi verificar o efeito da consistência do alimento sobre a atividade eletromiográfica dos músculos masseter e temporal anterior, durante a mastigação, bem como, avaliar a variação da temperatura muscular, verificando o efeito da mastigação sobre a temperatura superficial dos músculos em questão. Conclui-se que: 1) o aumento da consistência do alimento aumenta a atividade elétrica dos músculos do lado de trabalho e não trabalho, após 05 minutos de mastigação; 2) as médias da temperatura superficial no músculo temporal apresentaram diferenças estatisticamente significante entre os lados de trabalho e não trabalho, enquanto que no músculo masseter não houve diferença entre os lados; 3) que alimento mais consistente gerou temperatura superficial mais elevada nos músculos do lado de trabalho; 4) que após 5 e 10 minutos de mastigação houve uma redução significativa na temperatura superficial dos músculos analisados, porém, entre estes períodos não houve diferença estatisticamente significante. / The muscular effort demands metabolic modifications and an adaptation, in other words, a larger need of nutrients and O2 so that the muscular contraction is accomplished. The objective of the present study was to verify the effect of the consistence of the food on the eletromyography of the muscles masseter and previous storm, during the mastication, as well as, to evaluate the variation of the muscular temperature, verifying the effect of the mastication on the superficial temperature of the muscles in subject. It is ended that: 1) the increase of the consistence of the food increases the electric activity of the muscles beside work and not, after 05 minutes of mastication; 2) that the averages of the superficial temperature in the temporary muscle there were differentiates significant among the work sides and not work, while in the muscle masseter there was not difference among the sides; 3) that more solid food generated higher superficial temperature in the muscles beside work; 4) that there was a significant reduction in the superficial temperature of the analyzed muscles after 5 and 10 minutes of mastication, however, among these periods there was not differentiates significant.
5

O efeito da espessura da placa interoclusal sobre a atividade elétrica e a temperatura dos músculos temporal anterior e masseter durante o repouso e o apertamento dental

Pita, Murillo Sucena [UNESP] 16 December 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-12-16Bitstream added on 2014-06-13T18:35:14Z : No. of bitstreams: 1 pita_ms_me_araca.pdf: 1127223 bytes, checksum: 58ceb27b15fa47637a76872acfa04d3e (MD5) / O aumento da atividade muscular, induzido pelo apertamento dental, pode ser considerado como fator etiológico ou agravante das desordens temporomandibulares (DTMs), e essa atividade tem sido explorada de maneira direta através da eletromiografia e indiretamente pela variação da temperatura superficial cutânea sobre os músculos mastigatórios. As placas oclusais são os métodos não-invasivos mais utilizados para o tratamento das DTMs, particularmente as que afetam os músculos mastigatórios, objetivando a redução dessa hiperatividade muscular. Entretanto, há controvérsias em relação ao estabelecimento da sua espessura ideal. O objetivo do presente estudo, foi determinar o efeito da espessura de placas miorrelaxantes (3 mm e 6 mm) sobre a atividade elétrica e a temperatura dos músculos temporal anterior e masseter durante o repouso e o apertamento dental, considerando-se a condição assintomática de 20 indivíduos (10 homens e 10 mulheres) selecionados através do questionário Research Diagnostic Criteria (RDC). Os registros eletromiográficos foram realizados por meio do software “Bio EMG” (Biopack – System Bio-Research) e a temperatura das superfícies musculares realizada com o auxílio de um termômetro digital infravermelho (ICEL TD-971), com as respectivas medidas em microvolts ([V) e graus Celsius (ºC). Os resultados obtidos, analisados estatisticamente em um nível de 5% de significância (p<0,05), evidenciaram o aumento da atividade elétrica e a diminuição da temperatura dos músculos temporal anterior e masseter durante o apertamento dental em relação ao repouso. Entretanto não houve diferenças estatisticamente significativas em relação à atividade elétrica e a temperatura dos músculos mastigatórios entre as condições com e sem placa, entre o gênero masculino e feminino, bem como entre as espessuras de placas analisadas. / The increased of muscles activity, induced for dental clenching can be considered as causing or aggravating factor of temporomandibular disorders (TMD), and this activity has been exploited in a straightforward manner using electromyography and indirectly by the variation in skin surface temperature on the masticatory muscles. The occlusal splints are non-invasive methods more utilized for the treatment of TMD, particularly those from the masticatory muscles, aiming at the reduction of muscle hyperactivity. However, there are controversies regarding the establishment of their ideal thickness. The aim of this study was to determine the effect of thickness of the occlusal splints (3 mm and 6 mm) on the electrical activity and temperature of the anterior temporal and masseter muscles during dental clenching and resting, considering the asymptomatic condition of 20 individuals (10 males and 10 females) selected through the questionnaire Research Diagnostic Criteria (RDC). The electromyographic data were analyzed by the software Bio EMG (Biopack - Bio-Research System) and the surface temperatures of muscle carried out with the aid of a digital infrared thermometer (ICEL TD-971) and the corresponding measures in microvolts ([V) and degrees Celsius (ºC). The results, analyzed in a 5% of significance (p <0.05), showed increased electrical activity and lowering the temperature of the anterior temporal and masseter muscles during dental clenching in relation to the rest. However there were no statistically significant differences in relation to temperature and electrical activity of masticatory muscles between conditions with and without splints, between males and females, and between the thicknesses of occlusal splints analyzed.

Page generated in 0.0509 seconds