• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 1
  • 1
  • 1
  • Tagged with
  • 11
  • 11
  • 11
  • 7
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Management Strategies to Reduce Effects of Thermal Stress on Lactating Dairy Cattle

Zimbelman, Rosemarie Burgos January 2008 (has links)
Two strategies to reduce impact of heat stress on high producing dairy cows were examined. The first was to recalculate the temperature-humidity index (THI) using high producing dairy cows under diurnal summer conditions. This re-evaluation confirmed that current THI values underestimate the severity of heat stress levels. Therefore, cooling of dairy cattle during warm summer months should begin at a THI of 68. Previously, a THI equal to or greater than 72 has been used to define onset of heat stress. This study demonstrated that a THI greater than or equal to 68 is sufficient to increase body heat storage, respiration rate, skin evaporative heat loss, declines in feed intake and milk yield. A second objective involved three studies carried out to evaluate use of niacin in dairy cow rations to improve evaporative heat loss and resistance to heat stress. Niacin is known to cause intense vasodilation in human and lab species. We hypothesized that increasing vasodilation would improve evaporative heat loss in dairy cows. In the first niacin study, supplementation of lactating dairy cows with an encapsulated rumen by-pass form of niacin (NIASHURE™; Balchem Corporation, New Hampton, NY) at a dose of 12 g/d proved effective in alleviating some affects of heat stress during mild thermal stress. We hypothesized that encapsulated niacin would induce vasodilation effects documented in humans and lab animals increasing evaporative heat loss. Past research demonstrated that the possible mechanism for vasodilation affects seen by niacin were most likely due to prostaglandin D secretions. Niacin may act through increased prostaglandin D and E production and secretion by Langerhans cells which then act upon vascular endothelial prostaglandin D receptors to increase vasodilation. No studies have evaluated impact of encapsulated niacin on milk yield and composition during periods of thermal stress under commercial dairy conditions. The objective of the last study was to examine the effects of encapsulated niacin during heat stress on milk production and composition as well as core body temperatures under commercial conditions.
2

Vliv stájového prostředí na plodnost a užitkovost dojnic

KREJČOVÁ, Eva January 2016 (has links)
A major contributing factor to the maintaining high milk production along with good reproduction of dairy cows is to create an optimal environment of stables. The aim of this study was to assess the effect of changes in microclimate stables on milk production and fertility in the observed herd of dairy cows. Monitoring was conducted from February 2013 to December 2015. The data were obtained from reports of milk production, lactation records of dairy cows and program called AFI FARM. Temperature-humidity index was negatively correlated to milk yield (r = -0,172). There was also negatively correlation between temperature and milk yiel (r= -0.176). Correlation factor between the relative humidity and the milk yield was r = -0.073. There was found strong positively correlation between service period and insemination index, r = 0.886, weak positively correlation between service period and insemination interval r = 0.397 and moderate correlation between service period and embryonic mortality, r = 0.532. When the relative humidity in the stable increased from 32.00 % to 89.90 %, temperature was measured from - 0.6 ° C to 35.1 ° C. The values of temperaturehumidity index were ranged from 39.99 to 83.71. The hypothesis is confirmed one should conclude that the microclimate of stable affects milk production. On the other side, in relation to reproductive indicators, hypothesis was not confirmed.
3

Estudo da influencia de ondas de calor sobre a produção de leite no estado de São Paulo / The study of heat waves influence on the milk yield in São Paulo state

Lima, Karla Andrea Oliveira de 19 December 2006 (has links)
Orientadores: Daniella Jorge de Moura, Irenilza de Alencar Naas / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-08T00:23:24Z (GMT). No. of bitstreams: 1 Lima_KarlaAndreaOliveirade_M.pdf: 1645623 bytes, checksum: afa43b69c047d8214563bc3a0f3a1a1d (MD5) Previous issue date: 2006 / Resumo: Fenômenos climáticos de dimensões sem precedentes registrados nos últimos anos fizeram aumentar as preocupações na sociedade, pois estão de acordo com as projeções dos cientistas, segundo os quais qualquer mudança quanto ao clima médio afetará inevitavelmente a freqüência de acontecimentos climáticos extremos tais como ondas de calor e chuvas intensas. Onda de calor é um período de calor desconfortável anormal, geralmente acompanhado de alta umidade relativa com duração de pelo menos um dia, mas se estendendo por alguns dias ou mesmo semanas (AMS, 1989). A ocorrência destes eventos pode ocasionar o estresse térmico influenciando negativamente a produção animal, causando grandes perdas nos processos produtivos e reprodutivos. O presente trabalho teve como objetivo geral estimar as perdas da produção leiteira, em função da ocorrência de ondas de calor, nas bacias leiteiras do Estado de São Paulo, baseado no Índice de Temperatura e Umidade (ITU) médio. Para tanto foi determinada a freqüência de ocorrências de ITU acima do nível crítico. Foi elaborado um histórico de ocorrência de onda de calor no Estado de São Paulo baseado em dados climatológicos num intervalo de anos variando de três a dez anos. Também se quantificou as perdas médias estimadas de produção de leite nas principais regiões leiteiras durante os períodos identificados de onda de calor e por fim validaram-se os índices médios estimados de perdas na produção de leite com dados do controle leiteiro de uma fazenda comercial. Os resultados mostraram que os municípios da bacia leiteira do Vale do Paraíba e a cidade de Presidente Prudente foram os que apresentaram o maior número de ondas de calor por ano e que nem sempre as ondas de calor de maior duração apresentaram maior intensidade de ocorrência. Ao simular o Declínio na Produção Leiteira (DPL) das Bacias do Vale do Paraíba, São José do Rio Preto e Ribeirão Preto não foram encontradas diferenças bioclimáticas entre as mesmas. Observou-se que o DPL estimado superestimou as perdas produtivas efetivamente ocorridas, pois não considerou o efeito da adaptação dos animais ao calor nem a presença de equipamentos de climatização. Concluiu-se que o estudo da ocorrência de ondas de calor mostra de forma mais efetiva o efeito nocivo do ambiente térmico / Abstract: Climate phenomena recorded in the last years with dimensions without precedent raised the worry of society, as they are in accordance with the projections made by scientists who predicted that any change regarding the average weather may affect the frequency of occurrence of weather extremes such as heat waves and thunderstorms. Heat wave is a period of abnormal intense heat generally followed by high relative humidity with the duration of at least one day; however conventionally being extended by some days or even some weeks (AMS, 1989). The occurrence of heat waves can cause heat stress that input a negative influence in animal production causing high losses in production and reproduction processes. High environmental temperatures associated to high relative humidity almost lead to thermal discomfort which induces negatively metabolic and physiological responses. Thus this research has as general objective to estimate milk production losses as function of heat wave incidence in the dairy regions of São Paulo state based on the average temperature and humidity index (THI). Therefore it was determined the THI frequency of occurrence above the critical level. A historical of heat wave occurrence was developed based on climatic data in an interval of three to ten years. It was also quantified the estimated average milk production loss in the major dairy regions during the identified heat wave periods, finally the estimating production index was validated with milk production data from a commercial dairy farm. The results showed that the counties within the Paraiba Valley dairy region as well as Presidente Prudente County presented the highest number of heat wave occurrence per year, and that not always the heat wave with longest period presented higher intensity of occurrence. It was not found statistical difference in the bio climate when simulating the milk decline index (MDEC) for the regions of Paraiba valley, São José do Rio Preto, and Ribeirão Preto. It was observed that the simulated MDEC index present overestimated values for the milk production losses when compared to the real ones as it did not considered the effect of the animal adaptation to the heat neither the presence of acclimation equipments. The conclusion is that the study of heat wave occurrence shows in a more effective way the heat stress effect on dairy production which is not practically identified when studying just the average THI occurrence / Mestrado / Construções Rurais e Ambiencia / Mestre em Engenharia Agrícola
4

Caratterizzazione del bacino del Mediterraneo in funzione dell'indice bioclimatico "Temperature Humidity Index" (THI) e relazioni tra THI e mortalità nella bovina da latte. / Characterization of the Mediterranean basin in terms of "Temperature Humidity Index" (THI) and relationships between THI and mortality in dairy cows

SEGNALINI, MARIA 23 February 2012 (has links)
Condizioni meteorologiche e clima influenzano fortemente il settore delle produzioni animali. Lo stress da caldo determina una significativa riduzione dell'attività metabolica, della produzione, della capacità riproduttiva e una maggiore predisposizione alle malattie. Nel contesto biologico, la temperatura dell’aria è sicuramente considerata il principale fattore di stress, tuttavia, un’elevata umidità peggiora l'effetto della temperatura riducendo le perdite di calore per evaporazione e ostacolando quindi l’eliminazione del calore in eccesso. Scopi principali della ricerca sono stati la caratterizzazione dell’area del Mediterraneo in termini di Temperature Humidity Index (THI) e stabilire le relazioni tra stagione/THI e mortalità nella bovina da latte allevata in un’area geografica Italiana altamente vocata per questo tipo di allevamento. I risultati suggeriscono che, allevatori e politici che operano nell’area Mediterranea, dovrebbero tenere nella dovuta considerazione variabilità e scenari del THI nella pianificazione degli investimenti nel settore delle produzioni animali. Conoscere in anticipo il verificarsi di condizioni climatiche avverse permetterebbe agli allevatori di metter in atto misure di contrasto sugli effetti negativi delle condizioni climatiche. Inoltre, dovrebbero venire sviluppate misure di adattamento appropriate per contesti specifici in termini di cultura, società, o sistemi politici, che possano contribuire alla sostenibilità ambientale, nonché allo sviluppo economico e alla lotta alla povertà. / Weather and climate strongly influence the field of animal production. Heat stress causes a significant reduction in metabolic activity, production, reproductive capacity, and increases susceptibility to diseases. In the biological context, the air temperature is definitely considered the main factor of stress, however, high humidity worsens the effect of temperature by reducing the evaporation heat loss and thus preventing the removal of excess heat. The main purposes of the research were the characterization of the Mediterranean basin in terms of Temperature Humidity Index (THI) and to establish relationships between season/THI and mortality in dairy cattle bred in an Italian geographic area with a high concentration of dairy farms. THI variability and scenarios should be taken into careful consideration by farmers and policy makers operating in Mediterranean countries when planning investments. Investments should at least partially be directed to implementation of adaptation measures, which may support farmers in the transition to climate-smart agriculture and help them to alleviate the impact of hot extremes on animal welfare, performance and health. In addition, measures should be developed appropriate adaptation to the specific contexts in terms of culture, society, or political systems, which can contribute to environmental sustainability and economic development and fighting poverty.
5

Respostas biológicas de bovinos das raças Holandesa e Girolando sob estresse térmico / Biological responses in holstein and girolando cows under heat stress

Stumpf, Marcelo Tempel January 2014 (has links)
Trinta e oito vacas leiteiras, 19 da raça Holandês e 19 da raça Girolando (½ e ¾), foram submetidas à elevadas temperaturas por restrição à sombra durante o período entre a ordenha da manhã e da tarde. Mensurações de temperatura retal, frequências respiratória e cardíaca e escore de ofegação, além de coletas de sangue, foram realizadas nos períodos pré ordenha. Produção de leite e características físico-químicas do mesmo foram acessadas. Durante os períodos de coleta se avaliou características ambientais com vistas a calcular um índice de temperatura e umidade (ITU). Primeiramente se buscou estabelecer diferenças em parâmetros fisiológicos, de leite e sangue de vacas com diferentes porcentagens de alelos oriundos da raça Holandesa no genoma (100, 75 e 50%) em função de aumentos no ITU. Animais puros Holandês apresentaram características que condizem com menor tolerância ao calor do que animais Girolando. Em um segundo momento se analisou o efeito do estresse térmico sobre a permeabilidade das junções firmes das células epiteliais da glândula mamária de vacas Holandês. Além disso, buscou-se perceber alterações na estabilidade do leite ao teste do álcool decorrentes de um possível aumento na permeabilidade de tais estruturas celulares. O parâmetro utilizado para aferir tal efeito foi o nível sanguíneo de lactose no plasma. Alterações lácteas foram percebidas em função de aumentos de ITU e se devem principalmente à reduções em produção de leite. Aumento nos parâmetros fisiológicos não influenciou a estabilidade do leite. Leite instável apresentou maior teor de lactose. Maior número de dias em lactação pode ser o responsável pela redução na estabilidade do leite. Percebeu-se relação inversamente proporcional entre permeabilidade das junções firmes e estabilidade do leite, porém o estado de estresse térmico, ao contrário do esperado, não apresentou influência nas células da glândula mamária. / Thirty-eight dairy cows, 19 Holstein and 19 Girolando (½ e ¾), were submitted to elevated temperatures due to shade deprivation between morning and evening milkings. Rectal temperature, heart and respiratory rates and panting score measurements, besides blood samples collection, were performed before each milking. Milk production and its physical-chemical characteristics were studied. Climatic variables were measured during data collection to calculate a temperature-humidity index (THI). Firstly, the study evaluated changes in physiological, blood and milk parameters according to the percentage of alleles derived from the Holstein breed (100, 75 and 50%) due to increases in THI. Pure Holstein cows presented characteristics that indicate lower heat tolerance than Girolando cows. Secondly, heat stress effects on mammary gland cells tight junctions permeability were evaluated in Holstein cows. Alterations in milk stability due to changes in permeability were also assessed. Plasma lactose was the parameter used to detect changes in tight junctions permeability. Modifications in milk characteristics were probably due to reduction in milk production. Increase in physiological parameters did not affect milk stability. Unstable milk samples presented higher lactose levels. Higher days in milk might be the main responsible for reductions in milk stability. There was an inversely proportional relation between tight junctions permeability and milk stability to the ethanol test, although heat stress, contradicting the expected, did not influenced mammary gland cells.
6

Respostas biológicas de bovinos das raças Holandesa e Girolando sob estresse térmico / Biological responses in holstein and girolando cows under heat stress

Stumpf, Marcelo Tempel January 2014 (has links)
Trinta e oito vacas leiteiras, 19 da raça Holandês e 19 da raça Girolando (½ e ¾), foram submetidas à elevadas temperaturas por restrição à sombra durante o período entre a ordenha da manhã e da tarde. Mensurações de temperatura retal, frequências respiratória e cardíaca e escore de ofegação, além de coletas de sangue, foram realizadas nos períodos pré ordenha. Produção de leite e características físico-químicas do mesmo foram acessadas. Durante os períodos de coleta se avaliou características ambientais com vistas a calcular um índice de temperatura e umidade (ITU). Primeiramente se buscou estabelecer diferenças em parâmetros fisiológicos, de leite e sangue de vacas com diferentes porcentagens de alelos oriundos da raça Holandesa no genoma (100, 75 e 50%) em função de aumentos no ITU. Animais puros Holandês apresentaram características que condizem com menor tolerância ao calor do que animais Girolando. Em um segundo momento se analisou o efeito do estresse térmico sobre a permeabilidade das junções firmes das células epiteliais da glândula mamária de vacas Holandês. Além disso, buscou-se perceber alterações na estabilidade do leite ao teste do álcool decorrentes de um possível aumento na permeabilidade de tais estruturas celulares. O parâmetro utilizado para aferir tal efeito foi o nível sanguíneo de lactose no plasma. Alterações lácteas foram percebidas em função de aumentos de ITU e se devem principalmente à reduções em produção de leite. Aumento nos parâmetros fisiológicos não influenciou a estabilidade do leite. Leite instável apresentou maior teor de lactose. Maior número de dias em lactação pode ser o responsável pela redução na estabilidade do leite. Percebeu-se relação inversamente proporcional entre permeabilidade das junções firmes e estabilidade do leite, porém o estado de estresse térmico, ao contrário do esperado, não apresentou influência nas células da glândula mamária. / Thirty-eight dairy cows, 19 Holstein and 19 Girolando (½ e ¾), were submitted to elevated temperatures due to shade deprivation between morning and evening milkings. Rectal temperature, heart and respiratory rates and panting score measurements, besides blood samples collection, were performed before each milking. Milk production and its physical-chemical characteristics were studied. Climatic variables were measured during data collection to calculate a temperature-humidity index (THI). Firstly, the study evaluated changes in physiological, blood and milk parameters according to the percentage of alleles derived from the Holstein breed (100, 75 and 50%) due to increases in THI. Pure Holstein cows presented characteristics that indicate lower heat tolerance than Girolando cows. Secondly, heat stress effects on mammary gland cells tight junctions permeability were evaluated in Holstein cows. Alterations in milk stability due to changes in permeability were also assessed. Plasma lactose was the parameter used to detect changes in tight junctions permeability. Modifications in milk characteristics were probably due to reduction in milk production. Increase in physiological parameters did not affect milk stability. Unstable milk samples presented higher lactose levels. Higher days in milk might be the main responsible for reductions in milk stability. There was an inversely proportional relation between tight junctions permeability and milk stability to the ethanol test, although heat stress, contradicting the expected, did not influenced mammary gland cells.
7

Respostas biológicas de bovinos das raças Holandesa e Girolando sob estresse térmico / Biological responses in holstein and girolando cows under heat stress

Stumpf, Marcelo Tempel January 2014 (has links)
Trinta e oito vacas leiteiras, 19 da raça Holandês e 19 da raça Girolando (½ e ¾), foram submetidas à elevadas temperaturas por restrição à sombra durante o período entre a ordenha da manhã e da tarde. Mensurações de temperatura retal, frequências respiratória e cardíaca e escore de ofegação, além de coletas de sangue, foram realizadas nos períodos pré ordenha. Produção de leite e características físico-químicas do mesmo foram acessadas. Durante os períodos de coleta se avaliou características ambientais com vistas a calcular um índice de temperatura e umidade (ITU). Primeiramente se buscou estabelecer diferenças em parâmetros fisiológicos, de leite e sangue de vacas com diferentes porcentagens de alelos oriundos da raça Holandesa no genoma (100, 75 e 50%) em função de aumentos no ITU. Animais puros Holandês apresentaram características que condizem com menor tolerância ao calor do que animais Girolando. Em um segundo momento se analisou o efeito do estresse térmico sobre a permeabilidade das junções firmes das células epiteliais da glândula mamária de vacas Holandês. Além disso, buscou-se perceber alterações na estabilidade do leite ao teste do álcool decorrentes de um possível aumento na permeabilidade de tais estruturas celulares. O parâmetro utilizado para aferir tal efeito foi o nível sanguíneo de lactose no plasma. Alterações lácteas foram percebidas em função de aumentos de ITU e se devem principalmente à reduções em produção de leite. Aumento nos parâmetros fisiológicos não influenciou a estabilidade do leite. Leite instável apresentou maior teor de lactose. Maior número de dias em lactação pode ser o responsável pela redução na estabilidade do leite. Percebeu-se relação inversamente proporcional entre permeabilidade das junções firmes e estabilidade do leite, porém o estado de estresse térmico, ao contrário do esperado, não apresentou influência nas células da glândula mamária. / Thirty-eight dairy cows, 19 Holstein and 19 Girolando (½ e ¾), were submitted to elevated temperatures due to shade deprivation between morning and evening milkings. Rectal temperature, heart and respiratory rates and panting score measurements, besides blood samples collection, were performed before each milking. Milk production and its physical-chemical characteristics were studied. Climatic variables were measured during data collection to calculate a temperature-humidity index (THI). Firstly, the study evaluated changes in physiological, blood and milk parameters according to the percentage of alleles derived from the Holstein breed (100, 75 and 50%) due to increases in THI. Pure Holstein cows presented characteristics that indicate lower heat tolerance than Girolando cows. Secondly, heat stress effects on mammary gland cells tight junctions permeability were evaluated in Holstein cows. Alterations in milk stability due to changes in permeability were also assessed. Plasma lactose was the parameter used to detect changes in tight junctions permeability. Modifications in milk characteristics were probably due to reduction in milk production. Increase in physiological parameters did not affect milk stability. Unstable milk samples presented higher lactose levels. Higher days in milk might be the main responsible for reductions in milk stability. There was an inversely proportional relation between tight junctions permeability and milk stability to the ethanol test, although heat stress, contradicting the expected, did not influenced mammary gland cells.
8

AvaliaÃÃo de estresse tÃrmico em vacas leiteiras mestiÃas (bos taurus x bos indicus) criadas em clima tropical quente Ãmido no estado do cearà / Evaluation of heat stress in crossbred dairy cows (bos taurus x bos indicus) created in hot humid tropical climate in the state of cearÃ

David Ramos da Rocha 11 February 2008 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / Este trabalho teve o objetivo de avaliar a existÃncia de estresse tÃrmico em vacas leiteiras mestiÃas adultas (Bos taurus x Bos indicus) criadas em clima tropical quente Ãmido no municÃpio de Pacatuba-Ce, durante o ano de 2006. Para tal, avaliaram-se os fatores climÃticos de temperatura do ar (TA) e umidade relativa do ar (UR), os quais foram utilizados para cÃlculo do Ãndice de temperatura e umidade (ITU). A intervalos mensais, utilizando-se grupos de 14 a 20 animais lactantes por cada mÃs, foram realizadas mediÃÃes diÃrias (manhà e tarde) da temperatura retal (TR) para cÃlculo dos Ãndices de tolerÃncia ao calor (ITC), quais sejam: o Ãndice de Baccari Jr., IbÃria e Rauschenbach-Yerokhin. CorrelaÃÃes entre variÃveis de ambiente, ITU, ITC e TR foram estimadas atravÃs do mÃtodo de Pearson (p < 0,05). Os resultados mostraram que durante o ano, e tambÃm no perÃodo do dia, os animais estiveram sujeitos a diversas condiÃÃes de ambiente, porÃm, fora das suas respectivas zonas de conforto, principalmente quando se avaliou os valores mÃximos de temperatura, umidade relativa do ar e ITU. Observou-se tambÃm que as variÃveis de ambiente apresentaram cursos diÃrios e anuais inversos, com maiores valores no primeiro semestre e no perÃodo da manhà para a umidade relativa e maiores valores no segundo semestre e no perÃodo da tarde para temperatura do ar. As correlaÃÃes destas variÃveis ambientais com parÃme tros de ITU e temperatura retal mostraram que o ITU foi mais bem correlacionado com a TA (r = 0,84) do que com a UR (r = - 0,53). Os valores de TR apresentaram melhor correlaÃÃo com a TA (r =0,44) do que com a UR (r = - 0,50) e ITU (r = 0,31). Verificou-se ainda a existÃncia de uma fase de transiÃÃo correspondendo à Ãpoca de mudanÃa climÃtica entre os perÃodos chuvoso e seco, que esteve associada à elevaÃÃo dos valores de TR e, consequentemente, reduÃÃo dos valores de ITC. O Ãndice de IbÃria mostrou-se melhor correlacionado (r = - 0,99; p<0,05) com os valores de temperatura retal. Portanto, foi observado que, durante o ano, os animais estavam sujeitos a condiÃÃes ambientais fora da zona de conforto, principalmente em funÃÃo dos valores mÃximos de temperatura ambiente, umidade relativa e Ãndice de temperatura e umidade. A avaliaÃÃo do ITU e ITC poderà se constituir uma ferramenta eficiente para identificaÃÃo da susceptibilidade dos rebanhos ao estresse tÃrmico / A study was conducted to evaluate heat stress tolerance susceptibility in adult crossbred dairy cows (Bos taurus x Bos indicus), raised in tropical humid climate, at the county of Pacatuba, Ceara state. The study was carried out in 2006. We determined air temperature and air humidity to calc ulate the temperature humidity index (THI) and rectal temperature (RT) of all animals were taken monthly in the morning and afternoon to estimate the index of heat tolerance (IHT), according to the methods of Iberia, Baccari Jr. and Rauschenbach-Yerojhin. Number of animals varied from 14 to 20 per month. Correlations among all variables were determined following Pearsonâs method (p < 0.05). Results show that, during the year, animals were subjected to different climates although out of their comfort zone, especially when maximum values of temperature, humidity and THI were measured. Moreover, environment variables showed inverse daily and annual changes. Higher values of humidity were detected in the first semester and in the morning, while higher air temperatures were measured in the second semester and afternoon. THI was more associated with air temperature (r = 0.84) than with humidity (r = - 0.53). Values of RT were better correlated with AT (r = 0.44) then with AH (r = - 0.50) and THI (r = 0.31). Also, there was a transition phase corresponding to the change from rainy to dry seasons, which was associated with an increase in RT and, consequently, decrease in ITH. Among all ITH estimated in the present study, the Iberia index was found to show the highest correlations (r= -0.99; p<0.05) with values of rectal temperature. In conclusion, animals were, along the year, subjected to an environment regarded as out of their comfort zone, especially because of maximum air temperature, air humidity and ITH. Evaluations of ITH and THI could be used as an efficient tool for identification of heat stress tolerance of dairy cows raised in tropical regions
9

Tela de sombreamento e pintura em telhados de modelos reduzidos de galpões avícolas /

Gomes Filho, João Soares. January 2010 (has links)
Resumo: Quatro experimentos foram conduzidos para avaliar o efeito do sombreamento artificial e da pintura dos telhados na melhoria do conforto térmico de modelos reduzidos simulando galpões avícolas. Em todos os experimentos foram utilizadas coberturas com telha de fibrocimento, novas, sem cimento amianto, com 4,0mm de espessura. O Experimento 1 foi realizado na Universidade Estadual do Maranhão (UEMA), câmpus de São Luís, onde foram testados cinco tipos de coberturas: 1- sem tela, sem pintura (STSP - controle); 2- com tela a 0,05m de altura da telha, sem pintura (CT5SP); 3- com tela a 0,05m de altura da telha, com pintura (CT5CP); 4- com tela a 0,08m de altura da telha, sem pintura (CT8SP) e 5- com tela a 0,08m de altura da telha, com pintura (CT8CP). Foram determinados o Índice de Temperatura de Globo Negro e Umidade (ITGU), a Carga Térmica de Radiação (CTR) e a Entalpia Específica (H). As colheitas das variáveis meteorológicas (temperaturas de globo negro, de bulbo seco, de bulbo úmido e velocidade do vento) foram realizadas durante 12 dias experimentais (04 a 15 de nov. de 2009) às 10:00, 12:00, 14:00 e 16:00 horas. O tipo de cobertura CT5SP foi o que apresentou os melhores valores para ITGUcorr (79,81) e H (78,84 KJ.Kg-1 de ar seco). O melhor resultado para CTRcorr foi apresentado pelo tratamento CT5CP (480,12 W.m-2). O Experimento 2 foi realizado na Universidade Estadual Paulista (UNESP), câmpus de Jaboticabal, onde foram testados os mesmos tipos de coberturas do Experimento 1. As colheitas e registro das variáveis meteorológicas foram realizadas por 40 dias (13 de fev. a 24 de mar. de 2010), nos mesmos horários do Experimento 1. O tipo cobertura que proporcionou menor resultado para o ITGU (83,86) e H (86,41 KJ.Kg-1 de ar seco) foi o CT8CP. A menor CTR (549,52 W.m-2) foi verificada na cobertura CT5CP. O Experimento 3 objetivou verificar o efeito de dois tipos de telas... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Four experiments were conducted to assess the effect of shading and painting of roofs improving thermal comfort in reduced models of poultry houses. In all the experiments were used with roofing cement tile, new, no asbestos cement, with 4.0 mm thick. The first experiment was conducted at the Universidade Estadual do Maranhão (UEMA), campus of São Luís, where were tested five types of coverage: 1 - no shading, no paint (STSP - control), 2 - with shading 0.05 m in height tile, unpainted (CT5SP) 3 - with shading 0.05 m in height tile with painting (CT5CP) 4 - with shading 0.08 m in height tile, unpainted (CT8SP) and 5 - with shading 0.08 m height of the tile with painting (CT8CP). Were evaluated the index of black globe temperature and humidity (BGTHI), the Heat Load (HL) and the specific enthalpy (H). The readings of meteorological variables (black globe temperature, dry bulb, wet bulb temperatures and wind speed) were measured during 12 experimental days (from nov. 4th to 15th, 2009) at 10:00, 12:00, 14: 00 and 16:00 hours. The type of coverage CT5SP had the lowest values for BGTHI (79,81) and H (78,84 KJ.Kg-1 dry air). The best result for CTRcorr (480,12 W.m-2) was presented by treatment CT5CP. The second experiment was conducted at Universidade Estadual Paulista (UNESP), campus of Jaboticabal, where were tested the same types of coverages of Experiment 1. The collection and recording of meteorological variables were performed for 40 days (from feb. 13th to 24th, 2010), at the same times of Experiment 1. The type coverage that provided smaller results for the BGTHI (83,86) and H (86,41 KJ.Kg-1 dry air) was CT8CP. The lower HL (549,52 W.m-2) was verified with the coverage CT5CP. The third experiment aimed at assessing the effect of two types of shading screens (50 and 80%) on the thermal comfort... (Complete abstract click electronic access below) / Orientador: Renato Luís Furlan / Coorientador: Adhemar Pitelli Milani / Banca: Euclides Braga Malheiros / Banca: José Eduardo Pitelli Turco / Banca: Iran José Oliveira da Silva / Banca: Francisca Neide Costa / Doutor
10

Tela de sombreamento e pintura em telhados de modelos reduzidos de galpões avícolas

Gomes Filho, João Soares [UNESP] 21 September 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-09-21Bitstream added on 2014-06-13T18:45:24Z : No. of bitstreams: 1 gomesfilho_js_dr_jabo.pdf: 765540 bytes, checksum: 15848770f797f69a1af286f79d7dc8d4 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Quatro experimentos foram conduzidos para avaliar o efeito do sombreamento artificial e da pintura dos telhados na melhoria do conforto térmico de modelos reduzidos simulando galpões avícolas. Em todos os experimentos foram utilizadas coberturas com telha de fibrocimento, novas, sem cimento amianto, com 4,0mm de espessura. O Experimento 1 foi realizado na Universidade Estadual do Maranhão (UEMA), câmpus de São Luís, onde foram testados cinco tipos de coberturas: 1- sem tela, sem pintura (STSP – controle); 2- com tela a 0,05m de altura da telha, sem pintura (CT5SP); 3- com tela a 0,05m de altura da telha, com pintura (CT5CP); 4- com tela a 0,08m de altura da telha, sem pintura (CT8SP) e 5- com tela a 0,08m de altura da telha, com pintura (CT8CP). Foram determinados o Índice de Temperatura de Globo Negro e Umidade (ITGU), a Carga Térmica de Radiação (CTR) e a Entalpia Específica (H). As colheitas das variáveis meteorológicas (temperaturas de globo negro, de bulbo seco, de bulbo úmido e velocidade do vento) foram realizadas durante 12 dias experimentais (04 a 15 de nov. de 2009) às 10:00, 12:00, 14:00 e 16:00 horas. O tipo de cobertura CT5SP foi o que apresentou os melhores valores para ITGUcorr (79,81) e H (78,84 KJ.Kg-1 de ar seco). O melhor resultado para CTRcorr foi apresentado pelo tratamento CT5CP (480,12 W.m-2). O Experimento 2 foi realizado na Universidade Estadual Paulista (UNESP), câmpus de Jaboticabal, onde foram testados os mesmos tipos de coberturas do Experimento 1. As colheitas e registro das variáveis meteorológicas foram realizadas por 40 dias (13 de fev. a 24 de mar. de 2010), nos mesmos horários do Experimento 1. O tipo cobertura que proporcionou menor resultado para o ITGU (83,86) e H (86,41 KJ.Kg-1 de ar seco) foi o CT8CP. A menor CTR (549,52 W.m-2) foi verificada na cobertura CT5CP. O Experimento 3 objetivou verificar o efeito de dois tipos de telas... / Four experiments were conducted to assess the effect of shading and painting of roofs improving thermal comfort in reduced models of poultry houses. In all the experiments were used with roofing cement tile, new, no asbestos cement, with 4.0 mm thick. The first experiment was conducted at the Universidade Estadual do Maranhão (UEMA), campus of São Luís, where were tested five types of coverage: 1 - no shading, no paint (STSP - control), 2 - with shading 0.05 m in height tile, unpainted (CT5SP) 3 - with shading 0.05 m in height tile with painting (CT5CP) 4 - with shading 0.08 m in height tile, unpainted (CT8SP) and 5 – with shading 0.08 m height of the tile with painting (CT8CP). Were evaluated the index of black globe temperature and humidity (BGTHI), the Heat Load (HL) and the specific enthalpy (H). The readings of meteorological variables (black globe temperature, dry bulb, wet bulb temperatures and wind speed) were measured during 12 experimental days (from nov. 4th to 15th, 2009) at 10:00, 12:00, 14: 00 and 16:00 hours. The type of coverage CT5SP had the lowest values for BGTHI (79,81) and H (78,84 KJ.Kg-1 dry air). The best result for CTRcorr (480,12 W.m-2) was presented by treatment CT5CP. The second experiment was conducted at Universidade Estadual Paulista (UNESP), campus of Jaboticabal, where were tested the same types of coverages of Experiment 1. The collection and recording of meteorological variables were performed for 40 days (from feb. 13th to 24th, 2010), at the same times of Experiment 1. The type coverage that provided smaller results for the BGTHI (83,86) and H (86,41 KJ.Kg-1 dry air) was CT8CP. The lower HL (549,52 W.m-2) was verified with the coverage CT5CP. The third experiment aimed at assessing the effect of two types of shading screens (50 and 80%) on the thermal comfort... (Complete abstract click electronic access below)

Page generated in 0.059 seconds