• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 71
  • 34
  • 14
  • 8
  • 5
  • 5
  • 4
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 164
  • 30
  • 27
  • 26
  • 24
  • 23
  • 23
  • 20
  • 19
  • 17
  • 16
  • 14
  • 13
  • 13
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Precast Segmental Double-T Girder Systems for Multi-span Highway Overpass Bridges

Smith, Jeffrey Stuart 16 August 2012 (has links)
An alternative structural system for short span bridges is presented: a precast segmental double-T with external, unbonded post-tensioning tendons. Single-span designs from 20 to 45 m long show that the system can be implemented over a wide range of spans and that the system’s sensitivity to post-tensioning losses reported in previous literature can be reduced by aligning the prestressing force more concentrically. Designs for multi-span bridges using this system are presented using simply supported spans connected by thin flexible linking slabs made of ultra high-performance fibre-reinforced concrete and using sections made fully continuous over intermediate supports. A simplified method of geometry control is presented to facilitate the proper alignment of precast segments without the use of match casting. The precast segmental double-T bridge is compared to sixteen existing slab on girder bridges and found to be a competitive alternative in terms of material use, cost, construction schedule, and aesthetic merit.
102

The supraspinatus tendon : clinical and histopathological aspects /

Tillander, Bo, January 1900 (has links)
Diss. (sammanfattning) Linköping : Univ., 2001. / Härtill 5 uppsatser.
103

Anterior cruciate ligament reconstruction : patellar tendon, gore-tex, Kennedy LAD and tibia tunnel ingrowth /

Muren, Olle, January 2003 (has links)
Diss. (sammanfattning) Stockholm : Karol. inst., 2003. / Härtill 5 uppsatser.
104

Rehabilitation following bone-patellar tendon-bone graft ACL reconstruction /

Mikkelsen, Christina, January 2006 (has links)
Diss. (sammanfattning) Stockholm : Karolinska institutet, 2006. / Härtill 4 uppsatser.
105

Cartilage oligomeric matrix protein (COMP), thrombospondin-4 (TSP-4) and type I and III collagens in tendon : an immunohistochemical and biochemical study /

Södersten, Fredrik, January 2006 (has links) (PDF)
Diss. (sammanfattning) Uppsala : Sveriges lantbruksuniv., 2006. / Härtill 4 uppsatser.
106

Relevância da ultra-sonografia dos tendões flexores em cavalos puro sangue de corrida na adaptação ao treinamento / Significance of flexor tendon ultrasonography in training thoroughbreds

Greig, Carolina Roxana 30 August 2002 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The cross-sectional area (CSA) of the superficial digital flexor tendon (SDFT) and deep digital flexor tendon (DDFT) of twenty four thoroughbreds was ultrasonographically evaluated before and during their initial training to determine the effect of exercise on the tendon CSA, texture and echogenicity to characterize the response to training. Ultrasonographic transverse images of the left forelimb were obtained every fifteen days. The SDFT CSA of zones IA and IIIA showed a decrease (p<0.05, f=0.010 e f=0.023 res.) during the breaking and training period and an increase (p< 0.05) of zone IIIC (f=0.039). Evaluating just the training period, SDFT CSA results of zones IA, IIIA and IIIC were similar. The DDFT showed no variation during the breaking phase but when the training phase was evaluated there was a decrease(P<0.05) in zones IA (f=0.006) and IIIA(f=0.006). Evaluating both breaking and training periods the DDFT showed a decrease (P<0.05) in zones IA (f=0.027), IIIA (f=0.0001) and IIIB (f=0.0031). Fiber texture and tendon echogenicity showed no significant difference between breaking and last reading during training. This study failed to provide evidence of ultrasonographic image variations that would indicate adaptation of both SDFT and DDFT to exercise during training of thoroughbred horses. / Vinte e quatro potros Puro Sangue de Corrida (PSC), com dois anos de idade foram avaliados ultra-sonograficamente, durante o período final da doma e início de treinamento, através da imagem transversal dos tendões flexor digital superficial (TFDS) e profundo (TFDP). As avaliações foram realizadas com intervalos de 15 dias. A área transversal (AT), a textura dos ecos e a ecogenicidade dos tendões foram avaliadas nas sete zonas da região metacarpiana através de um programa de mensuração de imagens do próprio aparelho de ultra-sonografia. Durante a doma e treinamento houve diminuição da AT na zona IA e IIIA (p<0,05, f=0,001 e 0,0266 resp.) e aumento da zona IIIC (p< 0,05 f=0,0391) do TFDS. Ao considerar apenas o período do treinamento, o resultado foi semelhante (p<0,05) na zona IA (f=0,010), IIIA (f=0,023) e IIIC (f =0,0391). O TFDP apresentou uma diminuição na AT durante a doma e treinamento nas zonas IA, IIIA e IIIB (p<0,05, f=0,027; f=0,0001 e f=0,0031 resp.) e nas zonas IA e IIIA durante o treinamento (p<0,05, f=0,006 e f=0,006, resp.). No período da doma a AT do TFDP não variou significativamente. A textura dos ecos se manteve homogênea e não houve variação significativa na ecogenicidade dos tendões entre o período da doma e após quatro meses de treinamento. A avaliação quinzenal da AT, textura e ecogenicidade das zonas IA a IIIC dos TFDS e TFDP não apresentou variações ultra-sonográficas que sugerissem adaptação ao regime de exercício ao qual os potros PSC estavam sendo submetidos.
107

Análise de peças fletidas com protensão não aderente pelo método dos elementos finitos / Analysis of bending members with unbonded tendons through the finite element method

Jost, Daniel Trevisan January 2006 (has links)
Estruturas com protensão não aderente estão sendo utilizadas como uma alternativa na tecnologia de projeto e execução de edifícios. Este trabalho apresenta a análise numérica de estruturas com protensão não aderente. Para este fim, foi desenvolvido um programa computacional onde implementou-se um modelo não linear físico e geométrico através do método dos elementos finitos. O comportamento dos materiais é descrito por um modelo elasto-viscoplástico. No concreto, são utilizados elementos finitos isoparamétricos tridimensionais. Para representar o seu comportamento após a fissuração é utilizado o modelo de fissuras distribuídas. As armaduras são incluídas através do modelo incorporado, utilizando-se de elementos unidimensionais isoparamétricos.As armaduras passivas são consideradas como uma linha de material mais rígido no interior do elemento de concreto, existindo uma aderência perfeita entre o concreto e o aço. Nas armaduras não aderentes, é considerada a compatibilidade de deslocamentos entre os materiais apenas nas ancoragens, sendo que a armadura pode movimentar-se livremente no interior do concreto. O modelo não linear geométrico, utilizado para o concreto e para a armadura, foi desenvolvido com base na formulação Lagrangeana Total, considerando grandes deslocamentos e pequenas deformações. Para verificar a precisão do modelo computacional, compararam-se resultados numéricos com valores experimentais disponíveis na literatura. / Unbonded prestressed concrete structures have been increasingly used as an alternative in the technology of design and construction of buildings. This work presents a numerical analysis of unbonded prestressed concrete structures. To accomplish this, a computational program has been developed in which a physical and geometrical nonlinear model was implemented through the finite element method. Materials behavior has been described through an elasto-viscoplastic model. In the concrete, a threedimensional isoparametric finite element has been used. To represent its behavior after cracking, the smeared cracking model has been used to. The prestressing tendons and reinforcement have been included according with the embedded model approach by the use of one-dimensional isoparametric elements. The reinforcement has been considered in the model as a line of a stiffer material inside the concrete element, with a perfect bonding between concrete and steel. As for the unbonded tendons, displacement compatibility between materials has been considered only at the anchorages, but they are allowed to move freely along their length inside the concrete. The geometric nonlinear model that has been used for the concrete, reinforcement and tendons has been developed according to the Total Lagrangean formulation, considering large displacements and small strains. In order to evaluate the accuracy of the computational model, numerical results have been compared with experimental values available in the literature.
108

Implementação de rotinas computacionais para o projeto automático de peças em concreto com protensão aderente e não aderente

Lazzari, Paula Manica January 2011 (has links)
Este trabalho versa sobre o desenvolvimento de rotinas computacionais para o projeto automático de estruturas de concreto submetidas à protensão aderente e não aderente, conforme recomendações das normas brasileira [NBR6118:2007] e francesa [Règles BPEL 91]. A justificativa da realização deste trabalho vem da crescente utilização da protensão no Brasil, devido principalmente a suas vantagens construtivas, à redução na incidência de fissuras e na dimensão das peças com o emprego eficiente de materiais de maior resistência. Visando contribuir para o desenvolvimento científico nacional, o presente trabalho dá continuidade a uma linha de pesquisa que vem sendo desenvolvida no Programa de Pós- Graduação em Engenharia Civil – PPGEC/UFRGS, a qual foi iniciada com a implementação de um modelo numérico, baseado na formulação do elemento finito do tipo híbrido para pórticos planos, que faz a análise quanto à flexão de seções com protensão aderente e não aderente. A partir deste elemento finito, torna-se possível a utilização de elementos longos, de maneira que um único elemento finito possa ser utilizado para um vão de viga ou pilar, reduzindo, assim, o esforço computacional. O modelo numérico considera a não linearidade geométrica, carregamentos cíclicos e construção composta, levando em conta a concretagem por fases. Relações constitutivas já consolidadas na literatura são empregadas para os materiais, sendo que a cadeia de Maxwell é utilizada para representar o comportamento reológico do concreto e do aço de protensão, respeitando as características de cada material. Realizou-se, ainda, um estudo das variáveis necessárias na implementação do modelo numérico a fim de desenvolver uma interface gráfica amigável com a ajuda do software Microsoft Visual Basic 2008 Express Edition, disponível gratuitamente na internet, facilitando, desta forma, a entrada de dados. As rotinas computacionais implementadas efetuam a verificação dos estados limites de serviço e últimos, complementando o modelo numérico original. São consideradas as situações de protensão completa, limitada e parcial e verificados conforme cada caso, os estados limites de descompressão, de formação e de abertura das fissuras, além dos estados limites últimos finais, no ato da protensão e a verificação do esforço cortante. São apresentadas comparações entre situações de projeto conforme as normas brasileira e francesa, analisando de forma crítica os resultados obtidos. De um modo geral, observou-se que as verificações feitas pela norma francesa apresentaram resultados mais conservadores. Ao longo deste trabalho, buscou-se, como objetivo principal, tornar o programa computacional operacional para a realização de projetos. / This work presents the development of computational algorithms for the automatic design of concrete structures subjected to bonded and unbonded prestressing, according to the Brazilian [NBR6118:2007] and French [Règles BPEL 91] code specifications. The study is justified by the increased use of prestressing in Brazil, due to its many constructive advantages, like reduction in crack incidence and decrease in section dimensions, with the efficient use of higher resistance materials. It is part of a major research developed in the Graduate Program in Civil Engineering - PPGEC/UFRGS, started with the implementation of a numerical model based on the formulation of a hybrid type finite element for prestressed plane frames. Such model, makes possible the use long elements, so that a single finite element can be used for modeling a beam or column, therefore improving computational efficiency. The numerical model considers geometric nonlinearity, cyclic loading and composite construction, allowing different constructive stages. Well established constitutive relations are used for representing material behavior and the Maxwell chain model is used for both concrete and prestressing steel time-dependent responses. A study on the variables needed to implement the numerical model was performed, in order to develop a friendly graphical interface, with the help of Microsoft Visual Basic 2008 Express Edition, a free software that facilitates data acquisition. The implemented computational algorithm performs the verification of the Serviceability Limit States and the Ultimate Limit State, with a view to complementing the original numerical model. Full, partial and limited prestressing situations are considered and checked and, in each case, the Limit State of Decompression, the Limit State of Cracking, the Ultimate Limit State, the final act of prestressing and the Shear Strength are verified. Comparison between design situations according to the Brazilian and French code specifications are presented. In general, it was observed that verifications of the French code were more conservative. This work was focused on the main objective to make the computer program operational for structural design.
109

Efeito clínico do plasma rico em plaquetas em lesões cutâneas, tendíneas e ligamentares de equinos / Clinical effect of platelet-rich plasma on cutaneous, tendinous and ligament lesions in horses

Pereira, Roberta Carneiro da Fontoura 11 March 2016 (has links)
Platelet rich plasma (PRP) is a product obtained from whole blood through one or two centrifugations, resulting in small volume of plasma containing high number of platelets and growth factors. The growth factors from the α-granules are platelet components that are important in the homeostasis of injured tissues beginning and regulating some stages of tissue healing, promoting chemotaxis, cell proliferation and differentiation, neovascularization and deposition of extracellular matrix. Wound healing of skin lesions distal to the carpus or tarsus of horses, usually are complicated by the reduced blood supply, low oxygen tension and increased risk of bacterial contamination. In many cases when wounds are not treated properly, they can become chronic with excessive formation of granulation tissue. Tendinitis and desmites are pathologies characterized by degeneration of tendons and ligaments. The tissue degeneration mechanism of these structures is attributed to mechanical factors, vascular and inflammatory. Tendinitis and desmitis are common pathologies of equine athletes, these diseases tend to have long recovery periods, due to histological, anatomic and biomechanical features of tendons and ligaments. This thesis presents studies of 8 horses, in order to evaluate the clinical effect and the presence of recurrence lesions, of use of PRP and exercise controlled in the treatment of tendon and ligament injuries, through the clinical and ultrasonographic evaluation (CHAPTER 1), review by clinical and histopathological evolution the healing process of surgical wounds located at the distal region of forelimbs treated by three different methods of application of PRP (CHAPTER 2), and also determine the best form to PRP application to equine skin wounds ( CHAPTER 2.) In Chapter 1, it included eight horses, with an average age of 5 years (± 2.6) diagnosed with injuries in tendons and ligaments, through clinical and ultrasonographic evaluation. These animals underwent treatment with intralesional PRP, guided by ultrasound. The animals μL diagnosed with tendonitis (4/8) had lesion scores of 2.3 (± 0.57) (score 1 to 3), mean platelet concentration of 512.250 / uL (± 144.965) and average healing time of 262 days (± 82) (Table 2). In contrast, animals with desmitis (4/8) in the suspensory ligament injuries had a score of 2.6 (± 0.57) (score 1 to 3), mean platelet concentration of 566.500 / uL (± 97.722) and average healing time 120 days (± 42) (table 3). In this study no correlation was found between the number of platelets in the PRP, and the time for healing of tendonitis and desmitis. Clinical and ultrasonographic monitoring of intralesional injections of PRP, followed by gradual increase of exercise program, allowed the horses to return to his previous athletic activity without recurrence of the lesions. In Chapter 2 we used eight healthy horses, with an average age of 8 years (± 3.76), which were created four wounds of 4 cm2 area in the dorsolateral aspect of the third cannon bone, two on the left forelimb (A1 and A2) and two on the right forelimb (A3 and A4) (figure 1). The cutaneous lesions were treated according to the established treatment group. In the same animal, each of the four wounds were assigned to one of four treatment groups at random, for each treatment group obtained eight replicates in different regions in the forelimbs (Figure 1). In the group (G) I, the skin lesions were treated with PRP infiltration of the wound edges, the GII PRP was used in gel form, the GIII was used homologous PRP and GIV as a control group (without PRP application). In the wounds treated with the GII was reduced to a fortnight in healing time compared the wounds treated with the GIV. Histopathology GII presented a higher frequency of mild inflammation and neovascularization mild to moderate in biopsies 1 and 2. The GIV had the highest intensity of granulating wounds between the groups. PRP in gel form, both in the clinical evaluation as the histopathology showed the best result in the application on wounds in the distal member of horses. The homologous PRP can also be used as adjuvant in equine wound healing. / O plasma rico em plaquetas (PRP) é um produto obtido do sangue total, através de uma ou duas centrifugações, resultando em um pequeno volume deste plasma contendo elevado número de plaquetas e fatores de crescimento. Estes fatores de crescimento, provenientes dos α-grânulos plaquetários, são componentes importantes na homeostase de tecidos lesados, iniciando e regulando alguns estágios da cicatrização tecidual, por promover quimiotaxia, proliferação e diferenciação celular, neovascularização e deposição de matriz extracelular. As tendinites e desmites são patologias caracterizadas pela degeneração de tendões e ligamentos. O mecanismo de degeneração tecidual destas estruturas é atribuído a fatores mecânicos, vasculares e inflamatórios. As lesões tendíneas e ligamentares comprometem a performance atlética de equinos e cursam com longos períodos de cicatrização, devido às características de composição histológica, anatômica e biomecânica destas estruturas. A cicatrização das feridas localizadas distais ao carpo ou tarso de equinos é geralmente complicada pela falta de tecido de revestimento, menor suprimento sanguíneo, baixa concentração de oxigênio nos tecidos e maior risco de contaminação bacteriana. Em muitos casos quando não tratadas adequadamente, as feridas poderão tornar-se crônicas, com crescimento exacerbado do tecido de granulação. Na presente tese, são apresentados estudos com equinos com a finalidade de avaliar o efeito clínico, do número de plaquetas em relação ao tempo de cicatrização e índice de recidivas da utilização do PRP associado à exercícios controlados no tratamento de lesões tendíneas e ligamentares, avalidos por meio do exame clínico e ultrassonográfico (CAPÍTULO 1). Neste estudo também foi avaliado o processo de cicatrização de feridas cirúrgicas experimentais, localizadas na região distal dos membros locomotores, tratadas com três métodos distintos de aplicação do PRP e avaliada através da evolução clínica e histopatológica. Objetivou-se determinar a melhor forma de aplicação do PRP em feridas cutâneas de equinos (CAPÍTULO 2). No capítulo 1, foram incluídos oito equinos, com idade média de 5 anos (±2,6), diagnosticados com lesões em tendões e ligamentos, através da avaliação clínica e ultrassonográfica. Esses animais foram submetidos ao tratamento intralesional com PRP, guiado por ultrassonografia. Os animais diagnosticados com tendinite (4/8) tiveram escore das lesões de 2,3 (±0.57)(escala 1 a 3), média da concentração plaquetária de 512.250 /μl (± 144.965) e tempo médio de cicatrização de 262 dias (±82) (tabela 2). Em contrapartida, os animais com desmite (4/8) no ligamento suspensório apresentaram escore das lesões de 2,6 (± 0,57)( escala 0 a 3), média da concentração plaquetária de 566.500 /μl (± 97.722) e tempo médio de cicatrização de 120 dias (± 42) (tabela 3). Não foi observada correlação entre o número de plaquetas do PRP e o tempo de cicatrização das tendinites e desmites. A monitoração clínica e ultrassonográfica da resposta às injeções intralesionais de PRP, seguidas de programa de incremento gradual de exercício, permitiu que os cavalos retornassem à sua atividade atlética prévia sem recidiva das lesões. No capítulo 2 foram utilizados oito equinos hígidos, com idade média de 8 anos (± 3,76), onde foram criadas quatro feridas cutâneas de 4 cm2 de área, no aspecto dorsolateral do terceiro osso metarcapiano, duas no membro torácico esquerdo (A1 e A2) e duas no membro torácico direito (A3 e A4). As lesões cutâneas foram tratadas com três aplicações de PRP de acordo com o grupo estabelecido aleatoriamente. No grupo (G) I, as lesões cutâneas foram tratadas com infiltração de PRP nas bordas da ferida, no GII o PRP foi utilizado na forma gel sobre a área total da ferida, no GIII foi usado PRP homólogo e o GIV serviu como grupo controle (apenas aplicação de solução fisiológica) com infiltração nas bordas da ferida. Desta maneira, os quatro tratamento foram aplicados nas 4 feridas de um mesmo animal. Para cada grupo de tratamento obtivemos oito repetições em regiões distintas nos membros torácicos, nos oito cavalos avaliados. No GII houve redução de 15 dias no tempo de cicatrização quando comparada às feridas do GIV. Na análise histopatológica o GII apresentou maior frequência de inflamação leve e neovascularização leve a moderada, nas biópsias 1 e 2. O GIV apresentou a maior intensidade de granulação das feridas entre os grupos avaliados. O PRP na forma gel, tanto na avaliação clínica como na histopatológica apresentou o melhor resultado na aplicação em feridas cutâneas no membro distal de equinos. O PRP homólogo também pode ser utilizado como terapia celular adjuvante na cicatrização cutânea de equinos.
110

Análise de peças fletidas com protensão não aderente pelo método dos elementos finitos / Analysis of bending members with unbonded tendons through the finite element method

Jost, Daniel Trevisan January 2006 (has links)
Estruturas com protensão não aderente estão sendo utilizadas como uma alternativa na tecnologia de projeto e execução de edifícios. Este trabalho apresenta a análise numérica de estruturas com protensão não aderente. Para este fim, foi desenvolvido um programa computacional onde implementou-se um modelo não linear físico e geométrico através do método dos elementos finitos. O comportamento dos materiais é descrito por um modelo elasto-viscoplástico. No concreto, são utilizados elementos finitos isoparamétricos tridimensionais. Para representar o seu comportamento após a fissuração é utilizado o modelo de fissuras distribuídas. As armaduras são incluídas através do modelo incorporado, utilizando-se de elementos unidimensionais isoparamétricos.As armaduras passivas são consideradas como uma linha de material mais rígido no interior do elemento de concreto, existindo uma aderência perfeita entre o concreto e o aço. Nas armaduras não aderentes, é considerada a compatibilidade de deslocamentos entre os materiais apenas nas ancoragens, sendo que a armadura pode movimentar-se livremente no interior do concreto. O modelo não linear geométrico, utilizado para o concreto e para a armadura, foi desenvolvido com base na formulação Lagrangeana Total, considerando grandes deslocamentos e pequenas deformações. Para verificar a precisão do modelo computacional, compararam-se resultados numéricos com valores experimentais disponíveis na literatura. / Unbonded prestressed concrete structures have been increasingly used as an alternative in the technology of design and construction of buildings. This work presents a numerical analysis of unbonded prestressed concrete structures. To accomplish this, a computational program has been developed in which a physical and geometrical nonlinear model was implemented through the finite element method. Materials behavior has been described through an elasto-viscoplastic model. In the concrete, a threedimensional isoparametric finite element has been used. To represent its behavior after cracking, the smeared cracking model has been used to. The prestressing tendons and reinforcement have been included according with the embedded model approach by the use of one-dimensional isoparametric elements. The reinforcement has been considered in the model as a line of a stiffer material inside the concrete element, with a perfect bonding between concrete and steel. As for the unbonded tendons, displacement compatibility between materials has been considered only at the anchorages, but they are allowed to move freely along their length inside the concrete. The geometric nonlinear model that has been used for the concrete, reinforcement and tendons has been developed according to the Total Lagrangean formulation, considering large displacements and small strains. In order to evaluate the accuracy of the computational model, numerical results have been compared with experimental values available in the literature.

Page generated in 0.0301 seconds