1

Apport de la TEP-IRM en imagerie fonctionnelle rénale pour l’évaluation des mesures de néphroprotection / Contribution of PET-MRI in the evaluation of therapeutic strategies to slow down chronic kidney disease progression

Normand, Laetitia 01 July 2019 (has links)
La progression de l'incidence de l'insuffisance rénale chronique dans le monde nécessite d'améliorer les mesures visant à ralentir sa progression et son évolution vers l'insuffisance rénale terminale. Le régime pauvre en protéines ou la prévention des épisodes d'ischémie- reperfusion appartiennent à ces mesures de néphroprotection mais leur bénéfice n'est qu'incomplètement compris. Le rein étant un des organes les plus vascularisé, rapporté à son poids, l'évaluation concomitante de la perfusion rénale ([15O]H2O), du métabolisme oxydatif ([11C]acetate) puis du contenu tissulaire en oxygène (BOLD-IRM) est fondamentale dans la mesure où ces trois mesures ne sont pas corrélées de manière linéaire. La TEP-IRM, appareil hybride combinant les fonctionnalités de la TEP et de l'IRM, permet une évaluation concomitante de ces trois paramètres de manière non invasive et sur rein isolé ce qui permet de l'utiliser en recherche clinique pour l'évaluation de l'effet de différentes interventions. Les régimes pauvres en protéines ont démontré qu'ils permettaient un ralentissement du déclin de la fonction rénale mais le mécanisme à l'origine de cet effet bénéfique n'est pas connu. Nous avons démontré que le contenu en AGE (Advanced Glycation End Products ou protéines modifiées) d'une charge protéique était responsable de la mobilisation de la réserve fonctionnelle rénale avec une augmentation de la perfusion et du métabolisme oxydatif plus importants après une charge protéique riche en AGE par rapport à une charge protéique pauvre en AGE. Nos résultats permettent de s'interroger sur l'intérêt d'une alimentation pauvre en AGE pour les insuffisants rénaux chroniques au-delà d'une restriction protéique pure. La prévention des épisodes d'ischémie- reperfusion est également particulièrement importante dans le cadre de la néphroprotection alors que la revascularisation d'une sténose de l'artère rénale s'accompagne obligatoirement de lésions de reperfusion. L'utilisation de la ciclosporine avant la dilatation d'une sténose de l'artère rénale dans le cadre d'un pré conditionnement a permis de réduire les lésions rénales chez la souris mais ce bénéfice clinique n'a pas été démontré chez l'homme. L'étude CICLOSAAR qui a pour but d'évaluer le bénéfice d'un pré conditionnement par la ciclosporine A avant dilatation d'une sténose de l'artère rénale sur des paramètres fonctionnels rénaux (perfusion, métabolisme oxydatif et contenu tissulaire en oxygène) est en cours. Dans un second temps et afin d'améliorer l'applicabilité clinique de ces techniques d'imagerie fonctionnelle, nous avons démontré que l'acétate, qui était jusque-là utilisé comme un marqueur de métabolisme oxydatif, pouvait également être utilisé comme un marqueur de perfusion rénale grâce à la modélisation de son uptake par le rein. Au total, la TEP- IRM est un outil fondamental pour l'évaluation des paramètres fonctionnels rénaux de manière non invasive chez l'humain. La mise en évidence de l'impact du contenu en AGE sur la perfusion et le métabolisme rénal devrait permettre d'affiner nos conseils diététiques aux insuffisants rénaux pour prévenir la progression de la maladie vers l'insuffisance rénale terminale. L'étude CicloSAAR actuellement en cours devrait permettre d'améliorer les mesures mises en oeuvre pour protéger le rein des lésions de reperfusion après dilatation d'une sténose de l'artère rénale. Enfin, nos résultats sur la forte corrélation entre les données de perfusion en acétate et en eau devraient permettre d'utiliser ce traceur pour obtenir la perfusion et le métabolisme oxydatif à l'issue d'une seule injection de radio-traceur et renforcer l'applicabilité clinique de ces techniques / The increase in the incidence of chronic renal failure worldwide requires improvements in measures to slow its progression to end-stage renal failure. The low-protein diet or the prevention of episodes of ischemia-reperfusion belong to these measures of nephroprotection but their benefit is only incompletely understood. The kidney is one of the most vascularized organs, compared to its weight, the concomitant evaluation of renal perfusion ([15O] H2O), oxidative metabolism ([11C] acetate) and tissue content in oxygen (BOLD-IRM) is fundamental in that these three measures are not linearly correlated. PETMRI, a hybrid device combining the functionalities of PET and MRI, allows a concomitant evaluation of these three parameters in a non-invasive and isolated kidney way which allows to use it in clinical research for the evaluation of the effect of different interventions. Low-protein diets have been shown to slow down the decline in renal function, but the mechanism behind this beneficial effect is not known. We have demonstrated that the AGE (Advanced Glycation End Products) content of a protein load is responsible for the mobilization of the renal functional reserve with an increase in perfusion and oxidative metabolism after a high- AGE high- protein compared to a low- AGE high- protein load. Our results make it possible to question the interest of a low-AGE diet for chronic renal insufficiency beyond a pure protein restriction. The prevention of episodes of ischemia reperfusion is also particularly important in the context of nephroprotection, whereas the revascularization of a stenosis of the renal artery is necessarily accompanied by reperfusion injury. Use of ciclosporin prior to dilation of renal artery stenosis in pre-conditioning reduced renal damage in mice, but this clinical benefit has not been demonstrated in humans. The CICLOSAAR study, which aims to evaluate the benefit of pre-conditioning with ciclosporin before dilation of renal artery stenosis with renal functional parameters (perfusion, oxidative metabolism and tissue oxygen content) is in progress. In a second step and to improve the clinical applicability of these functional imaging techniques, we have shown that acetate, which was previously used as a marker of oxidative metabolism, could also be used as a marker of renal perfusion through the modeling of its uptake by the kidney. In total, PET-MRI is a fundamental tool for the evaluation of renal functional parameters in a non-invasive way in humans. Demonstrating the impact of the AGE content of a protein load on perfusion and renal metabolism should help refine our dietary advice to patients with chronic kidney disease to prevent progression of the disease to end-stage renal failure. The current CicloSAAR study is expected to improve the measures implemented to protect the kidney from reperfusion injury after dilatation of renal artery stenosis. Finally, our results on the strong correlation between acetate and water perfusion data should allow this tracer to be used to obtain perfusion and oxidative metabolism after a single radio tracer injection and reinforce clinical applicability of these techniques
2

Développement de méthodes quantitatives en imagerie simultanée TEP-IRM / Development of quantitative methods in simultaneous PET-MR imaging

Petibon, Yoann 19 June 2015 (has links)
Le mouvement des organes durant l’acquisition et la réponse impulsionnelle (RI) du système dégradent les images obtenues par Tomographie par Emission de Positons (TEP). Récemment, les scanners simultanés TEP-Imagerie par Résonance Magnétique (IRM) ont été introduits, offrant une solution au problème du mouvement qui peut être estimé grâce à l’IRM pour corriger les images TEP. Néanmoins, pour profiter pleinement de ces nouvelles possibilités, il est également important de corriger les images des effets de la RI. L’objectif de ce travail est de proposer des méthodes TEP-IRM permettant d’améliorer la qualité des images TEP. Pour ce faire, nous avons développé des techniques d’acquisitions/traitement de données IRM permettant de mesurer le mouvement des organes. Nous avons modélisé la RI non-stationnaire du système grâce à des mesures de sources ponctuelles. Nous avons ensuite intégré l’information de mouvement IRM -au niveau des cartes d’émission et d’atténuation- et le modèle de la RI dans un algorithme de reconstruction TEP permettant d’obtenir des images corrigées des effets du mouvement et de la RI. Ces méthodes ont été évaluées pour des applications oncologiques et cardiaques sur des acquisitions de fantômes, d’animaux et de patients, qui ont montré une amélioration de la caractérisation des tumeurs abdominales et des lésions du myocarde. De plus, nous avons développé des méthodes permettant d’améliorer l’imagerie TEP de plaques athéromateuses fragiles dans les coronaires et les avons évaluées avec des simulations réalistes TEP-IRM. Les résultats obtenus montrent que les techniques proposées améliorent la qualité des images TEP par rapport aux méthodes conventionnelles. / The physiologic motion of organs during the data acquisition and the finite system’s Point Spread Function (PSF) both limit the image quality of Positron Emission Tomography (PET). Recently, whole-body (WB) simultaneous PET-Magnetic Resonance (MR) scanners have become available. This modality offers an elegant solution to the motion problem since MR-based motion information can be used to correct the PET images for motion. Nevertheless, to fully benefit from the new capabilities offered by PET-MR, it is essential to also compensate the images for PSF-related degradations. The goal of this thesis was to develop methods allowing to improve PET image quality using PET-MR. In that perspective, we have developed MRI acquisition/processing techniques to measure organs’ motion. We have modeled the spatially-varying PSF using point source measurements. We have then incorporated MR-based motion information (of both emission and attenuation maps) and PSF modeling into fully-3D iterative PET reconstruction, yielding images virtually free of motion artifacts while reducing PSF-related effects. These methods were evaluated for two key applications of WB PET-MR, oncology and cardiology, using phantom, animal and patient studies, demonstrating improved image quality and assessment of tumors and myocardial defects. In addition, we have developed methods allowing to improve PET imaging of small coronary atherosclerotic plaques, a promising pre-clinical application of PET-MR, which were evaluated using a realistic PET-MR simulation study. Overall, the results obtained demonstrate that the developed methodology can substantially improve PET image quality as compared to standard methods.
3

Imagerie multimodale et quantitative en TEP/IRM / Multimodal and quantitative imaging in PET/MRI

Monnier, Florian 02 March 2018 (has links)
L’introduction en clinique de la bimodalité combinant la tomographie d’émission de positons (TEP) et la tomodensitométrie (TDM) a été un succès dans les années 2000. La multimodalité dans le contexte de l’imagerie médicale a souvent pour but de combiner une information physiologique à une information anatomique. Deux approches existent : la première étant d’acquérir séparément les modalités et de les combiner ultérieurement par fusion d’images sur ordinateur, la seconde s’affranchit des problèmes possibles du recalage en opérant une acquisition dans le même statif des deux modalités. Cependant, il existe des limites à l’imagerie TEP/TDM. L’idée de combiner l’imagerie par résonance (IRM) magnétique à la TEP offre des avantages par rapport à la TDM. Notamment, l’IRM offre un excellent contraste des tissus et offre l’accès à de l’information multidimensionnelle, fonctionnelle et morphologique grâce à la modularité offerte par l’acquisition IRM. Cette information pourrait permettre de mieux comprendre les processus physiopathologiques des maladies. De plus, l’IRM n’est pas ionisante, au contraire de l’imagerie TDM. L’introduction au début des années 2010 des premiers appareils d’acquisition simultanée TEP/IRM offre de nombreuses possibilités, mais il reste des défis à résoudre avant d’assister à la même diffusion en clinique que l’imagerie TEP/TDM de ces appareils. Notamment, l’atténuation photonique, qui doit être corrigée afin de permettre le caractère quantitatif de l’imagerie, est un problème. Dans ce travail, nous abordons cette question en proposant des solutions pour les différentes régions du corps. Une attention particulière est portée à la région pelvienne. L’état de l’art des méthodes disponibles expose un faible nombre de solutions pour cette région, pourtant riche en tissus osseux atténuants et zone d’occurrence du second cancer le plus commun chez l’homme : le cancer de la prostate. Nous évaluons l’impact de la solution proposée sur la correction des photons diffusés, toujours dans un objectif d’obtenir une imagerie quantitative. Les différentes méthodologies de correction et d’évaluation font intervenir des simulations numériques Monte Carlo. / The clinical introduction of the bimodality combining the positron emission tomography (PET) and the computed tomography (CT) has been a major success in the 2000s. Multimodality, in the context of medical imaging, often has the aim of associating a physiological information and an anatomical information. Two approaches exist : either the two modalities are acquired separately and then fused through computerized image fusion, or we discard the issues related to image registration by acquiring in the same system the two modalities. However, there remain limits to PET/CT imaging. The idea to combinemagnetic resonance imaging (MRI) to PET offers solutions and advantages compared to the use of TDM.MRI offers an excellent tissue contrast and offers an access to multidimensional functional and morphological information thanks to the modularity offered by MRI. This information could improve the understanding of the physiopathological processes involved in diseases. Moreover, MRI is non-ionizing modality, on the contrary to CT. The introduction in the early 2010s of the first simultaneous PET/MRI systems offers a lot of possibilities, but there remains challenged to solve before observing the same spread as the PET/CT in imaging facilities. In particular, the photon attenuation, which must be corrected to provide a quantitative imaging, remains an issue. In this work, we address this issue by proposing solutions for the different regions of the body. A special attention is drawn to the pelvic region. Indeed, the state of the art of available methods exposes a small number of solutions for this area ; even so it is rich in attenuation osseous tissues et area of occurrence of the second most common cancer in men : prostate cancer. We assess the impact of the proposed solution on the scattered photons correction, still in the aim of obtaining a quantitative imaging modality. The different methodologiesof correction and evaluation use Monte Carlo numerical simulations.
4

Evaluation clinique et expérimentale des nouvelles modalités d'imagerie dans la prise en charge des néoplasies ORL notamment par la TEP/IRM / Clinical and experimental evaluation of multiparametric imaging of head and neck carcinomas in particular by TEP / MRI

Varoquaux, Arthur Damien 09 December 2014 (has links)
En oncologie ORL, l'imagerie multiparamétrique est utilisée par un nombre grandissant d'équipes. Parmi les bio-marqueurs, la captation normalisée du fluoro-désoxyglucose (SUV-FDG) en tomoscintigraphie par émission de positons (TEP) et la restriction de la diffusion en IRM (DWI-MRI) sont les plus utilisées.L'IRM couplée à la TEP (TEP/IRM) est une nouveauté qui permet une diminution très significative des doses d'irradiation délivrées par rapport à la TEP/TDM. Nous adressons notre première expérience concernant l'aspect en diffusion et en TEP/IRM dans la surveillance des patients après radio-chimiothérapie. A la question de l'interchangeabilité du FDG-PET et de la DWI-MRI, nous avons tenté d'identifier un lien en imagerie entre la cellularité tumorale et sa consommation glucidique. La cellularité tumorale est approchée en IRM par la mesure du coefficient apparent de diffusion (ADC) et son métabolisme glucidique est approché en TEP en utilisant le 18F-desoxyglucose (FDG) par la mesure de la valeur de fixation normalisée (SUV). Dans une série appariée de 33 patients, nous avons analysé la reproductibilité des mesures de l'ADC et de SUV. Puis nous avons évalué l'indépendance statistique de ces biomarqueurs. Nous avons ensuite voulu comparer les résultats de la TEP obtenus à partir de la TEP/TDM et de la TEP/IRM. Dans une série prospective appariée chez 32 patients explorés en FDG-TEP, nous avons évalué qualitativement les images obtenues par la fusion des images recalées en TEP/IRM et TEP/TDM. Nous avons ensuite comparé la pertinence clinique des deux techniques. Et enfin nous avons comparé les valeurs quantitatives de SUV obtenues du tissu sain et du tissu pathologique. / Multiparametric imaging interest and clinical use is rising for head and neck carcinoma (HNC). Among these modalities, FDG in PET and DWI-MRI are the most studied. PET/MRI is a new modality that allows in a single examination of combined various biologic biomarkers.After an optimization process of PET/MRI, we applied our first experience concerning the aspects of DWI-MRI and PET-MRI after radiation therapy. Thereafter we studied the correlation of SUV and ADC in HNC. In this study SUV and ADC values were independent parameters in HNSCC. Measurements of these two biomarkers were reproducible with almost perfect observer agreements for both methods. Neither SUV nor ADC values were able to predict the histologic grade, although a trend towards higher SUV and lower ADC values was observed in poorly differentiated tumours. Secondly, we we studied detection and quantification of focal uptake in head and neck tumours: 18F-FDG PET/MRI versus PET/CT in 32 consecutive HNSCC who underwent 18F-FDG PET/MRI and PET/CT. Attenuation correction sequence for PET/MRI and CT for PET/CT were used to caculate SUV. In results, PET/MRI coregistration and image fusion was feasible in all patients. There was no statistically significant difference between PET/MRI and PET/CT regarding rating scores for image quality, fusion quality, lesion conspicuity or anatomic location, number of detected lesions and number of patients with and without malignant lesions. A high correlation was observed for SUV measured on PET/MRI and PET/CT. SUV measured on PET/MRI were significantly lower than on PET/CT for malignant tumours, metastatic neck nodes, benign lesions, bone marrow, and liver (p <0.05).

Page generated in 0.0731 seconds