• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • 4
  • 1
  • Tagged with
  • 19
  • 19
  • 14
  • 7
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Imagerie quantitative du dépot d'aérosols dans les voies aériennes par résonance magnétique de l'hélium-3 hyperpolarisé / Hyperpolarized helium-3 MRI for detection and quantification of aerosol deposition in the airways

Sarracanie, Matthieu 06 July 2011 (has links)
Le paysage des thérapies inhalées connaît de profondes évolutions depuis les deux dernières décennies, avec pour objet la considération nouvelle du poumon comme un site de transfert des agents thérapeutiques vers le compartiment sanguin. Cette approche originale est apparue par la combinaison de développements théoriques et pratiques multiples impliqués dans la mise au point de nombreux médicaments, depuis le traitement de la douleur et du diabète jusqu'à la vaccination et le traitement de certains cancers. La quantité effective de médicament délivrée par aérosols est pondérée par de nombreux facteurs dont le mode et les conditions d’inhalation, les propriétés physiques des gaz en jeu, la morphologie des voies respiratoires ou encore les propriétés physico-chimiques des particules véhiculées. Les développements en cours ces quatre dernières années ont été conditionnés par des résultats encore mal compris, soulignant les limites des connaissances sur le transport et le dépôt d'aérosols dans le poumon. Ces manques mettent en avant le besoin d'outils performants pour l'évaluation du dépôt de particules dans les voies respiratoires.Les techniques d’imagerie permettent à la fois l’évaluation spatiale et quantitative du dépôt, avec pour seules références aujourd’hui, les techniques de médecine nucléaire. Outre l’aspect ionisant de ces techniques, elles bénéficient d’une sensibilité de détection encore inégalée. Elles demeurent néanmoins limitées par des résolutions spatiale et temporelle faibles, rendant le plus souvent difficile tant l’interprétation du dépôt que le rôle joué par les principaux mécanismes de clairance dans les voies aériennes. Depuis la fin des années 1990, les techniques de résonance magnétique imagent des noyaux hyperpolarisés (hélium-3 et xenon-129) et établissent de nouveaux standards dans l’exploration de la fonction pulmonaire.Cette thèse établit, sur la base de l’IRM de l’hélium-3 hyperpolarisé, une nouvelle modalité d’imagerie pour détecter et quantifier le dépôt d’aérosols dans les voies aériennes.Dans un premier temps, et dans un contexte où l’imagerie par résonance magnétique ne s’était pas encore penchée sur la problématique des aérosols thérapeutiques, un vaste travail d’investigation a été mené pour évaluer la sensibilité de l’IRM de l’hélium-3 hyperpolarisé au dépôt d’aérosols marqués à base d’oxyde de fer superparamagnétique. Le second volet de ce travail s’est porté sur la validation de notre méthode d’évaluation, et sur le développement de la quantification du dépôt d’aérosols. Nous avons enfin pu tester la reproductibilité de notre méthode d’évaluation du dépôt in vivo chez le rat, grâce à la réalisation d’une plateforme de ventilation et d’administration de gaz et d’aérosols dédiée, SAGAS. / Inhalation therapy has broadened its field of application over the last two decades by considering the lung not only as an organ to cure, but also as a portal toward systemic circulation. This new approach is being made possible by the emergence of biotherapeutics and a greater understanding of the absorption properties of the lung. Systemic delivery across the oronasal route was then investigated for a number of indications including migraine, diabetes, pain, and cancer. However, progress into the market of systemic aerosolized drug delivery has been slowed down to-date by a number of confounding factors including rapid clearance, instability, long-term toxicity, and dosing issues. Final drug distribution in such complex geometries strongly depends on a variety of parameters like the aerosol administration protocol, particle size, density, and physicochemical properties, as well as the airway geometry. Independently of drug formulation and pharmacokinetic considerations, these parameters determine the deposition distribution throughout the lung. Quantification and spatial localization are primordially needed to better control and optimize drug concentration at specific or less- and nonspecific sites. Nuclear medicine techniques are currently the only available modalities that combine both aerosol quantification and regional localization. They are considered as reference techniques even though they remain limited by their spatial and temporal resolutions as well as by patient exposure to radiations. With regard to lung imaging, hyperpolarized helium-3 MRI has been developed as a powerful tool to quantitatively characterize the parenchyma and the organ function and morphology. The technique is innocuous and provides millimeter and sub-second resolutions with rather high signal to noise ratios. In this thesis, a new imaging modality was developed on the grounds of hyperpolarized helium-3 MRI to probe and quantify aerosol deposition in the airways. In the first part of the thesis, I describe the potential of helium-3 MRI to probe aerosol deposition by using superparamagnetic contrast agents. The second part mainly focuses on the validation of this new modality by comparing it to a reference technique, single photon emission computed tomography (SPECT), and computational fluid dynamics. The last part of the manuscript is dedicated to aerosol administration and in vivo measurements in rat lungs. This experiment was possible by designing and building an MR compatible gas administrator and ventilator dedicated to small animals, SAGAS (Small Animal Gas Administration System). Its complete hardware and software description is presented in the same chapter.
2

Imagerie quantitative du dépot d'aérosols dans les voies aériennes par résonance magnétique de l'hélium-3 hyperpolarisé

Sarracanie, Mathieu 06 July 2011 (has links) (PDF)
Le paysage des thérapies inhalées connaît de profondes évolutions depuis les deux dernières décennies, avec pour objet la considération nouvelle du poumon comme un site de transfert des agents thérapeutiques vers le compartiment sanguin. Cette approche originale est apparue par la combinaison de développements théoriques et pratiques multiples impliqués dans la mise au point de nombreux médicaments, depuis le traitement de la douleur et du diabète jusqu'à la vaccination et le traitement de certains cancers. La quantité effective de médicament délivrée par aérosols est pondérée par de nombreux facteurs dont le mode et les conditions d'inhalation, les propriétés physiques des gaz en jeu, la morphologie des voies respiratoires ou encore les propriétés physico-chimiques des particules véhiculées. Les développements en cours ces quatre dernières années ont été conditionnés par des résultats encore mal compris, soulignant les limites des connaissances sur le transport et le dépôt d'aérosols dans le poumon. Ces manques mettent en avant le besoin d'outils performants pour l'évaluation du dépôt de particules dans les voies respiratoires.Les techniques d'imagerie permettent à la fois l'évaluation spatiale et quantitative du dépôt, avec pour seules références aujourd'hui, les techniques de médecine nucléaire. Outre l'aspect ionisant de ces techniques, elles bénéficient d'une sensibilité de détection encore inégalée. Elles demeurent néanmoins limitées par des résolutions spatiale et temporelle faibles, rendant le plus souvent difficile tant l'interprétation du dépôt que le rôle joué par les principaux mécanismes de clairance dans les voies aériennes. Depuis la fin des années 1990, les techniques de résonance magnétique imagent des noyaux hyperpolarisés (hélium-3 et xenon-129) et établissent de nouveaux standards dans l'exploration de la fonction pulmonaire.Cette thèse établit, sur la base de l'IRM de l'hélium-3 hyperpolarisé, une nouvelle modalité d'imagerie pour détecter et quantifier le dépôt d'aérosols dans les voies aériennes.Dans un premier temps, et dans un contexte où l'imagerie par résonance magnétique ne s'était pas encore penchée sur la problématique des aérosols thérapeutiques, un vaste travail d'investigation a été mené pour évaluer la sensibilité de l'IRM de l'hélium-3 hyperpolarisé au dépôt d'aérosols marqués à base d'oxyde de fer superparamagnétique. Le second volet de ce travail s'est porté sur la validation de notre méthode d'évaluation, et sur le développement de la quantification du dépôt d'aérosols. Nous avons enfin pu tester la reproductibilité de notre méthode d'évaluation du dépôt in vivo chez le rat, grâce à la réalisation d'une plateforme de ventilation et d'administration de gaz et d'aérosols dédiée, SAGAS.
3

Développement de substrats actifs et d'une méthode d'analyse de FRET quantitative pour décoder la mécanotransduction / Development of active substrates and of a quantitative FRET analysis method to decode mechanotransduction

Coullomb, Alexis 16 October 2018 (has links)
Les cellules vivantes sont capables de réagir aux signaux mécaniques tels que la rigidité de la surface sur laquelle elles adhèrent, les forces de tractions ou compressions auxquelles elles sont soumises, le flux de liquide à la surface de leur membrane ou encore la géométrie de leurs adhésions ou de leur forme globale. Ces signaux influent sur des processus cellulaires tels que la prolifération, la différenciation, la migration et la mort cellulaire. Ces processus sont finement régulés par des réactions biochimiques qui forment un réseau de signalisation. La mécanotransduction est la traduction du signal mécanique en signal biochimique.C’est dans le but d’étudier la mécanotransduction que nous avons étudié l’utilisation d’ultrasons pour stimuler mécaniquement les cellules à des fréquences temporelles et spatiales relativement élevées. De nombreux montages expérimentaux et de nombreuses voies ont été considérées dans cette partie très exploratoire. Nous en retenons finalement des pistes prometteuses pour la continuation future de ce projet.Nous avons développé ce que nous nommons des substrats actifs, qui nous permettent de contrôler à la fois spatialement et temporellement la stimulation mécanique appliquée à des cellules vivantes. Ces substrats actifs consistent en des micropiliers de fer incrustés dans un élastomère peu rigide (PDMS) et manipulés par deux électroaimants. Nous pouvons contrôler dynamiquement le déplacement des piliers qui vont déformer localement et de manière continue la surface. Cette déformation va ensuite déformer en traction ou en compression les cellules vivantes étalées sur la surface à proximité. En employant des marqueurs fluorescents nous pouvons réaliser de la Microscopie de Forces de Traction et surveiller la contrainte appliquée par les piliers aux cellules à travers la surface de PDMS, et nous pouvons étudier la réponse mécanique des cellules. De plus, ces substrats sont compatibles avec la microscopie de fluorescence en cellule vivante, ce qui rend possible l’observation de la réponse cellulaire au niveau morphologique (forme des adhésions focales, activité protrusive, …) et surtout biochimique.En effet, pour étudier la réponse biochimique des cellules après une stimulation mécanique, nous observons par microscopie de fluorescence des biosenseurs portant des paires de fluorophores donneur/accepteur. Ces biosenseurs nous permettent d’observer l’activité de protéines impliquées dans la signalisation cellulaire en calculant l’efficacité de Transfert d’Énergie Résonnant de Förster (FRET) de ces biosenseurs. Pour ce faire, les échantillons sont illuminés alternativement aux longueurs d’ondes d’excitation des fluorophores donneurs puis accepteurs. Le signal de fluorescence est collecté simultanément dans un canal d’émission du donneur et un canal d’émission de l’accepteur. Une grande partie de ma thèse a été consacrée à la mise au point d’une méthode quantitative pour analyser les images de fluorescence afin de mesurer une efficacité de FRET qui ne dépende pas de facteurs expérimentaux ni de la quantité de biosenseurs présents dans les cellules. Nous évaluons alors les différentes méthodes pour déterminer les facteurs de correction répandus corrigeant le débordement de spectre du donneur dans le canal accepteur et l’excitation directe de l’accepteur à la longueur d’onde d’excitation du donneur. Pour obtenir des mesures plus quantitatives, nous avons mis au point une nouvelles méthode pour déterminer 2 facteurs de correction supplémentaires. Nous comparons cette méthode à la seule préexistante et évaluons l’influence des paramètres de traitement des images sur les valeurs d’efficacité de FRET mesurées. / Living cells can react to mechanical signals such as the rigidity of the surface they adhere on, the traction or compression forces applied on them, the liquid flow at their membrane surface or the geometry of their adhesions or of their overall shape. Those signals influence cellular processes such as proliferation, differentiation, migration or cell death. Those processes are tightly regulated by biochemical reactions that constitute a signaling network. Mechanotransduction is the translation of the mechanical signal into the biochemical one.In order to study mechanotransduction, we have considered the use of ultrasounds to mechanically stimulate cells at relatively high temporal and spatial frequencies. Numerous setups and options have been considered in this very exploratory project. Finally, we will retain some promising leads for the continuation of this project.We have developed what we call active substrates that allows us to control both spatially and temporally the mechanical stimulation on living cells. Those active substrates consist of iron micropillars embedded in a soft elastomer and actuated by 2 electromagnets. We can control dynamically the displacement of the pillar that will deform locally and continuously the surface. This deformation will then deform in traction or in compression the living cells spread on the surface nearby. Thanks to fluorescent trackers we can perform Traction Force Microscopy and monitor the stress applied by the pillars to the cells through the PDMS surface, and we can look at the mechanical response of the cells. Moreover, those substrates are compatible with live cell fluorescence microscopy, which makes possible the observation of the cellular response at the morphological level (focal adhesions, protrusive activity, …) and most importantly at the biochemical level.Indeed, in order to study the cellular biochemical response after a mechanical stimulation, we use fluorescence microscopy to observe biosensors containing pairs of donor/acceptor fluorophores. Those biosensors allow us to monitor the activity of proteins implied in cellular signaling by computing the Förster Resonance Energy Transfer (FRET) efficiency of those biosensors. To do so, samples are alternatively excited at donor and acceptor excitation wavelengths. The fluorescence signal is then simultaneously measured in donor and acceptor emission channels. A substantial part of my thesis has been dedicated to the development of a quantitative method to analyze fluorescence images in order to measure FRET efficiencies that do not depend on experimental factors or biosensors concentration in cells. We assess different methods to compute standard correction factors that account for spectral bleed-through and direct excitation of acceptors at donor excitation wavelength. To obtain more quantitative measurements, we have developed a new method to compute 2 additional correction factors. We compare this method with the only one preexisting, and we assess the influence of image processing parameters on FRET efficiency values.
4

Optimisation de la dosimétrie en alphathérapie par approche multi-échelle : application au traitement des métastases osseuses par le ²²³Ra / Optimization of dosimetry in alphatherapy by a multi-scale approach : application to the treatment of bone metastases with ²²³Ra

Benabdallah, Nadia 21 December 2017 (has links)
La radiothérapie interne vectorisée (RIV) repose sur l’administration d’un radiopharmaceutique, qui va se distribuer dans le corps du patient et se fixer plus spécifiquement dans les régions tumorales afin de les détruire. Récemment, le développement de nouveaux radiopharmaceutiques, notamment des émetteurs alpha, rend la discipline particulièrement prometteuse. En effet, leurs propriétés leur confèrent, par rapport aux émetteurs β-, une plus grande cytotoxicité pour les cellules tumorales tout en limitant l’irradiation non désirée aux tissus sains.L’objectif dans le domaine est plus particulièrement de déterminer, pour chaque patient, l’activité à injecter permettant d’obtenir un maximum de dose à la tumeur tout en ne dépassant pas les limites de dose aux organes à risques. Pour les radiopharmaceutiques émetteurs alpha, l’évaluation dosimétrique est un véritable challenge au vu du faible parcours de ces particules.Pour répondre à ce challenge, les études proposées se sont portées sur le ²²³Ra (Xofigo®) qui est le premier radiopharmaceutique émetteur alpha à avoir obtenu en novembre 2013 l’autorisation de mise sur le marché, valide dans toute l’Union Européenne, pour le traitement de patients atteints de métastases osseuses du cancer de la prostate. Ces études se sont articulées sous la forme de trois défis.Le premier défi est d’être en mesure de réaliser des images afin de connaître la répartition de l’activité dans le corps du patient. En effet, le faible parcours des particules alphas ne permettent pas à ceux-ci d’être détectés. Toutefois, le ²²³Ra et ses descendants émettent plusieurs raies gamma. Un protocole optimisé pour l’obtention d’images du ²²³Ra à l’aide d’une gamma-caméra a été mis en place en collaboration avec l’Hôpital Européen Georges Pompidou. De nombreuses expériences ont été réalisées à l’aide de fantômes physiques. Ce protocole d’imagerie a été accepté dans le cadre d’un nouvel essai clinique multicentrique (HEGP, Cochin, IGR, Caen, Bordeaux) de phase I/II dédié au traitement par le ²²³Ra des métastases osseuses du cancer rénal.La distribution spatiale du radiopharmaceutique ainsi connue, il s’agit de prendre en compte son évolution temporelle. Ainsi, pour calculer l’activité cumulée à partir d’images dynamiques, un algorithme a été intégré au logiciel de dosimétrie interne OEDIPE (Outil d’Evaluation de la Dose Interne PErsonnalisée), développé depuis une quinzaine d’années à l’IRSN. Ce dernier permet, à l’aide de calculs Monte Carlo directs, d’effectuer une dosimétrie précise et personnalisée en prenant en compte les données anatomiques et fonctionnelles du patient.Le deuxième défi concerne la détermination de l’énergie absorbée dans les parties radiosensibles de l’os. A l’heure actuelle, les paramètres dosimétriques utilisés ne considèrent pas l’énergie de l’alpha, le site squelettique ou la proportion de moelle rouge. Ainsi, les calculs de dose ont été optimisés en utilisant les modèles de l’os les plus réalistes à l’heure actuelle.Enfin, le troisième défi est de connaître la distribution du ²²³Ra à l’échelle sub-cellulaire pour relier au mieux la dose aux effets biologiques. Ces paramètres étant difficilement caractérisables chez un patient, des études ont été réalisées sur la souris. Des modèles animaux sains et présentant des métastases osseuses dérivant d’un cancer du rein ou de la prostate ont été développés en collaboration avec le CIPA à Orléans. La différence de fixation et de répartition du ²²³Ra entre les tissus sains et les métastases pour les différents modèles a été étudiée, à l’échelle microscopique, à l’aide d’images autoradiographiques réalisées en collaboration avec le CRCNA de Nantes.Finalement ce travail de recherche a permis d’appréhender les divers aspects de la dosimétrie interne appliqués au ²²³Ra. Il offre également des outils pour aller plus loin dans la personnalisation de la dosimétrie des nouveaux radiopharmaceutiques émetteurs alpha, actuellement en plein essor. / Targeted therapy is based on the administration of a radiopharmaceutical, which will bind specifically in tumor regions in order to destroy them. Nowadays, this field is more and more promising thanks to the development of new radiopharmaceuticals, especially alpha emitters. Indeed, their characteristics confer a greater cytotoxicity to tumor cells while minimizing the unwanted radiation to healthy tissues in comparison with β- emitters.The goal here is to determine the administered activity, for each patient, which will ensure a maximum dose deposition in the tumor and a minimum dose deposition to the organs at risk. For alpha emitting radiopharmaceuticals, the dosimetric evaluation is a main challenge because of the particles short range.To meet this challenge, the proposed studies will focus on ²²³Ra (Xofigo®), which is the first alpha emitter that has received marketing authorization from European Commission in November 2013 for the treatment of patients with castration-resistant prostate cancer metastasized to bones. These studies were organized in three different challenges.The first challenge is to perform ²²³Ra imaging in order to determine the activity distribution in patient body. Indeed, the short path of alpha particles prevents their detection. Nevertheless, ²²³Ra and its daughters have several gamma emissions. An optimized ²²³Ra imaging protocol for gamma-camera was implemented in collaboration with the European Hospital George Pompidou. Many experiments were performed on physical phantoms. This protocol was then accepted in a new multicenter phase I/II clinical trial for the treatment of renal cell carcinoma with bone metastases.After the determination of the spatial distribution of the radiopharmaceutical, the temporal evolution must be taken into account. In order to calculate the cumulated activity from dynamic imaging, a biokinetic module has been implemented to the OEDIPE software (French acronym for “tool for personalized internal dose assessment”). This software developed by IRSN for the last fifteen years can perform precise and personalized Monte Carlo dosimetry from patient-specific anatomic and functional data.The second challenge involves the determination of the absorbed energy in the radiosensitive parts of the bone. Nowadays, the dosimetric parameters do not take the alpha particle energy, the bone site or the bone marrow proportion into account. Thus, dose calculations were optimized using the most recent and realistic bone models.Lastly, the third challenge is to characterize the distribution of ²²³Ra at the microscopic level in order to better assess the relationship between dose and biological effects. As theses parameters cannot be properly characterized on human, studies were performed on mice. Healthy mice and metastasis models, from a renal or prostate cancer, were developed in collaboration with the CIPA in Orléans. Differences of uptake between healthy tissues and metastases were studied in each model, at the microscopic scale using autoradiography methods performed in collaboration with the CRCNA at Nantes.Finally, this research work has helped to gain more insight into the various aspects of the ²²³Ra dosimetry. This work also offers tools to go further in dosimetry personalization for new alpha emitting radiopharmaceuticals, currently on the rise.
5

Développements précliniques de nouveaux outils utilisant les ultrasons transcraniens guidés par IRM haut champ pour la délivrance de médicaments dans le cerveau et la stimulation non invasive de circuits neuronaux / Development of preclinical tool using transcranial ultrasound under high field MR-guidance for drug delivery to the brain and non-invasive neurostimulation

Magnin, Rémi 07 January 2016 (has links)
La Barrière Hémato-Encéphalique (BHE) représente aujourd’hui un obstacle majeur pour le développement de nouveaux traitements des pathologies cérébrales puisqu’elle empêche le passage de la majorité des agents thérapeutiques vers le cerveau. Afin de contourner cet obstacle, une technique proposée dans les années 2000 a montré son potentiel pour perméabiliser la BHE de façon non-invasive, locale et transitoire grâce à l’utilisation conjointe de microbulles circulantes et d’ultrasons focalisés, permettant une augmentation significative de la quantité de molécules délivrée aux tissus cérébraux. Ce protocole peut néanmoins présenter des risques (œdèmes, micro-hémorragies) qu’il est possible de maîtriser grâce à un bon contrôle du faisceau acoustique. A ce titre, l’imagerie par résonance magnétique (IRM) représente un outil de choix permettant à la fois de planifier la procédure, puis de la suivre et enfin d’étudier ses effets grâce à l’utilisation d’agents de contraste et de séquences d’imagerie quantitative (relaxométrie T1 / T2). Durant cette thèse, nous avons développé de nouveaux outils permettant l’étude de la perméabilisation de la BHE chez le rongeur. Dans un premier temps, nous avons développé et validé un système motorisé compatible IRM, permettant de déplacer le transducteur ultrasonore à l’intérieur d’un scanner préclinique à 7T, avec un rétro-contrôle en temps réel du faisceau ultrasonore sur la base des images IRM de la force de radiation acoustique (MR-ARFI). Nous avons montré que ce dispositif permettait de réaliser l’ensemble du protocole de perméabilisation de BHE guidé par IRM en choisissant la structure anatomique à traiter de façon reproductible. Nous avons également montré qu’il pouvait être utilisé pour délivrer des molécules sur des régions étendues du cerveau selon des trajectoires arbitrairement programmées. Dans une seconde partie de cette thèse, nous avons réalisé plusieurs études en vue d’étudier l’innocuité de la technique. Nous avons mis en évidence l’influence de certains paramètres acoustiques sur l’efficacité du protocole (pression acoustique, temps de cycle), puis nous avons réalisé une étude histologique des dommages engendrés par une perméabilisation chez des animaux sains pour plusieurs pressions acoustiques, entre 0 et 14 jours post-ultrasons. Enfin, dans une troisième partie, nous avons étudié la diffusion de différents agents de contraste paramagnétiques dans les tissus cérébraux suivant une perméabilisation focale de la BHE. Nous avons montré que cette technique permettait d’obtenir des mesures précises de la tortuosité des tissus cérébraux de façon non-invasive et que cette tortuosité n’était pas modifiée par les ultrasons, contrairement à ce qui est observé suite à une injection intracérébrale. / By preventing most of the molecules from penetrating the brain in sufficient quantitiy, the Blood Brain Barrier represents a major obstacle for the development of new therapeutic drugs for brain diseases. A new technique introduced in the early 2000’s combining focused ultrasound and circulating microbubbles has however shown promising results, allowing to induce a local and transient permeabilization of the BBB in a non-invasive manner, thus significantly improving the amount of drugs delivered to the Central Nervous System (CNS). However, this protocol may present some risks (oedema, small hemorrages) which can be avoided by a good control of the acoustic beam properties. To do so, Magnetic Resonance Imaging (MRI) represents a very useful tool since it allows planning, monitoring and following the permeabilization effects by using MRI contrast agents and quantitative imaging sequences (T1/T2 relaxometry). During this PhD, we worked on developing new tools for the study of ultrasound induced BBB permeabilization in rodents. The first part of this work consisted in developing a MR compatible motorized device, allowing the displacment of the ultrasound transducer within a 7T preclinic MRI scanner, with a realtime feedback on the acoustic beam position thanks to MR Acoustic Radiation Force Imaging (MR-ARFI). We have shown that this system allowed performing a full BBB permeabilization protocol under MR-guidance, with an accurate and reproducible choice of the targeted anatomical structure. This system was also used to deliver drugs along arbitrary trajectories over extended regions of the brain. Another part of the work was dedicated to study and improve the safety of the procedure. The influence of different acoustic parameters (acoustic pressure, duty cycle) on the permeabilization efficacy was studied, as well as histologic investigations of short and mid-term effects of BBB permeabilization for different acoustic pressures on healthy rats. Finally, we investigated the diffusion process of contrast agents within the brain tissues following BBB permeabilization. We have shown that this technique allowed accurate measurements of brain tissues tortuosity in a non-invasive way, and found that the tortuosity was not modified by the ultrasound application.
6

Imagerie préclinique multimodale chez le petit animal : qualification des instruments et des méthodes (IRM, µTDM et µTEMP) / Preclinical multimodal small animal imaging : qualification of instruments and methods (MRI, µCT and µSPECT)

Dillenseger, Jean-Philippe 26 September 2017 (has links)
L’imagerie préclinique se pratique majoritairement sur des modèles animaux murins principalement des souris (61%), elle représente une étape indispensable en recherche préclinique car elle suit les deux premières recommandations de la règle des 3R (réduction, raffinement et remplacement). Pour donner une signification biologique aux mesures extraites des images acquises in vivo chez la souris, il est nécessaire d’évaluer les performances des instruments utilisés mais également des procédures expérimentales en jeu. La qualification des appareils nécessite l’usage de fantômes spécifiques, et l’évaluation des méthodes impose de tester les procédures sur des individus non pathologiques, avant le passage aux expérimentations proprement dites. L’objectif de ce travail a été de développer des outils et des méthodes permettant de qualifier les instruments d’imagerie et certaines procédures in vivo. La nécessité de quantification, à partir d’images réalisées chez le petit animal, nous amène à considérer les instruments d’imagerie préclinique comme des outils métrologiques ; ce qui amène à intégrer le principe d’incertitude de mesure dans l’expression des résultats. / Preclinical imaging is mostly performed on mouse animal models (61%). It is a necessary step in preclinical research, in compliance the first two recommendations of the 3Rs rules (reduction, refinement and replacement). In order to give a biological significance to measurements extracted from in vivo-acquired mouse images, it is necessary to evaluate instruments performances but also experimental procedures involved. The qualification of apparatuses requires the use of specific phantoms while the evaluation of methods requires procedures tests on non-pathological animals before experimentations. The scope of this work was to develop tools and methods to qualify imaging instruments and in vivo procedures. The need for quantification in small animal imaging, leads us to consider preclinical imaging instruments as metrological tools; which means integrating measurement uncertainty into.
7

Quantitative and functional ultrafast ultrasound imaging of the human brain / Imagerie quantitative et fonctionnelle du cerveau humain par ultrasons ultrarapides

Imbault, Marion 03 May 2017 (has links)
L'objectif de cette thèse était d'explorer le potentiel de l’imagerie du cerveau humain par ultrasons. L'anatomie, le flux sanguin et la rigidité des tissus mous ont déjà été étudiés avec l'imagerie ultrasonore ultrarapide chez l'homme et validés sur plusieurs organes, tels que le sein et le foie, mais pas encore sur le cerveau adulte. La principale limitation de l'imagerie échographique transcrânienne est aujourd'hui le très fort artefact d'aberration induit par le crâne. En effet, l’os, de par sa composition ne permet pas la propagation des ultrasons comme ailleurs dans le corps humain. Dans cette thèse, nous avons utilisé l'imagerie ultrasonore ultrarapide pour l'évaluation de la rigidité des tissus mous et l'imagerie neurofonctionnelle dans le cerveau humain adulte, lors de chirurgies du cerveau afin de contourner dans un premier temps le problème des aberrations induites par le crâne. La dernière partie de cette thèse était axée sur la correction d’aberration pour l’échographie quantitative et l’imagerie ultrasonore transcrânienne. Nous avons tout d’abord fourni plusieurs preuves de l'intérêt d'utiliser l’élastographie par onde de cisaillement pendant la chirurgie du cerveau. Nous avons également présenté notre nouvelle technique d’élastographie par onde de cisaillement en 3D à l'aide d'une sonde matricielle dans le but de pouvoir dépasser les limitations du 2D et notamment être moins dépendant de l’opérateur.Dans un second volet, nous avons démontré la capacité des ultrasons ultrarapides à identifier, cartographier et différencier en profondeur les régions d'activation corticales en réponse à un stimulus, à la fois chez les patients éveillés et chez les patients anesthésiés. Nous avons démontré que l'imagerie neurofonctionnelle par ultrasons a le potentiel de devenir une modalité complète de neuroimagerie avec des avantages majeurs pour une utilisation peropératoire.Dans un troisième volet, nous avons utilisé une technique en trois étapes pour calculer précisément la vitesse du son (SSE) dans un milieu. Cette technique a été testée dans des fantômes ultrasonores et in vivo dans les foies de patients. Dans les deux cas, notre méthode a été capable de trouver la vitesse du son correspondant au milieu. Nous avons démontré que la SSE était liée à la fraction de graisse. Cette analyse a permis de conclure que la SSE était en mesure de distinguer un foie sain et d’un foie malade aussi bien avec la biopsie qu’avec l’IRM comme méthode de référence. Combiné à l'utilisation de la formule de Wood, nous avons même pu avoir accès à une fraction de graisse mesurée par ultrasons de manière non invasive. Puis nous avons combiné la correction d’aberration de phase, d'amplitude et de vitesse du son pour faire de l’imagerie transcrânienne en simulation numérique. Nous avons atteint notre objectif en obtenant des images représentant fidèlement le milieu (position latérale et profondeur) et caractérisées par une résolution et un contraste similaires à ceux obtenus avec une source ponctuelle dans le milieu / The objective of this thesis was to explore the potential of human brain ultrasound imaging. Anatomy, blood flow and soft tissue stiffness have already been studied with ultrafast ultrasound imaging in humans and validated in several organs, such as, the breast and liver but not yet on the adult brain. The main limitation of transcranial ultrasound imaging is today the very strong skull-induced aberration artefact. Indeed, the bone, due to its composition, does not allow for ultrasound propagation as elsewhere in the human body. Therefore, this thesis was focused on the development of ultrafast ultrasound imaging for the evaluation of soft tissue stiffness and neurofunctional imaging in the adult human brain, during brain surgery to bypass the problem of skull aberration, and on an aberration correction technique for transcranial ultrasound imaging.We first provided several evidence of the benefit of using shear wave elastography during brain surgery. We also presented our new technique for 3D shear wave elastography using a matrix array in order to be able to overcome the limitations of 2D imaging and in particular to reduce the operator dependence.In a second phase, we demonstrated the capability of ultrasound to identify, map and differentiate in depth cortical regions of activation in response to a stimulus, both in awake patients and in anaesthetized patients. We have demonstrated that ultrasound neurofunctional imaging has the potential to become a comprehensive modality of neuroimaging with major benefits for intraoperative use. In a third part, we developed a new sound speed estimation (SSE) technique, based on a three-step technique that estimates the sound speed accurately corresponding to the illuminated medium. This technique was tested in ultrasound phantoms and in vivo in patient’s liver. In both cases, our method was able to find the sound speed corresponding to the medium. We demonstrated that SSE was related to the fat fraction. This analysis led to the conclusion that SSE was able to distinguish a healthy liver from a diseased liver with both biopsy and MRI as gold standard. Combined with the use of the Wood’s formula, we were even able to access a fat fraction measured by non-invasive ultrasound. Finally, by combining the phase, the amplitude and the sound speed estimation, we have developed a new aberration correction algorithm to perform transcranial ultrasound imaging. By performing numerical simulations, we obtained images that faithfully represented the medium (lateral position and depth) and characterized by one resolution and one contrast similar to those obtained with a punctual source in the medium
8

Imagerie microonde: influence de la polarimétrie du champ diffracté

Le Brusq, E. 23 October 2003 (has links) (PDF)
Le travail présenté dans ce mémoire de thèse s'intéresse au problème de l'imagerie microonde bidimensionnelle polarimétrique. Il est scindé en deux parties, la première est dédiée aux études expérimentales liées à la détection d'objets enfouis tandis que la seconde présente le développement d'un algorithme d'imagerie quantitative. Ainsi le travail effectué dans la première partie du manuscrit porte sur la réalisation d'antennes ultra-large bande et la détermination de leur comportement lors de mesures polarimétriques sur sites. Dans ce dernier cas, plusieurs tests ont été réalisés et permettent de conclure sur les qualités des capteurs développés. Dans une deuxième phase, un code d'imagerie bidimensionnelle prenant en compte à la fois la polarisation 2D-TM et 2D-TE est présenté. Le développement d'un algorithme de diffraction électromagnétique est tout d'abord exposé. Son association avec un algorithme de problème inverse existant déjà au laboratoire permet alors de générer le code d'imagerie quantitative. Plusieurs configurations de reconstruction d'objet homogène, isotrope ou non, permettent ensuite de mettre en évidence ses capacités.
9

Techniques d'imagerie quantitatives : fluorescence induite par laser appliquée aux écoulements et aux combustions

BRESSON, Alexandre 21 November 2000 (has links) (PDF)
Les techniques de mesures optiques non intrusives développées depuis plusieurs dizaines d'années permettent la mesure des paramètres physiques tels que la température, la concentration des espèces chimiques et la vitesse. Tous ces diagnostics optiques, bien que très performants, sont généralement appliqués en mesures ponctuelles.<br />Le but de la thèse est de développer une ou plusieurs techniques d'imagerie quantitatives et instantanées de température et de concentration. Deux axes d'études complémentaires ont été abordés au cours de ce travail. Il s'agit de la fluorescence induite par laser sur le radical OH pour l'étude des milieux en combustion et de la fluorescence induite par laser d'un traceur moléculaire (acétone) pour l'étude des écoulements non réactifs. Ces deux axes d'étude ont été menés en parallèle avec la même approche : après compilation des données bibliographiques, des modèles de fluorescence induite par laser de ces deux espèces ont été développés. Les résultats de ces modélisations ont servi à sélectionner les meilleures stratégies expérimentales. <br />Des expériences pilotes ont été mises en place en vue développer ces techniques d'imagerie. Elles consistent en l'utilisation des modèles proposés pour les deux traceurs étudiés afin d'obtenir des images instantanées et couplées de température et de concentration dans différents types d'écoulements (combustion hydrogène–air, mélange de jets, ...). <br />D'autres applications ont été réalisées sur des bancs d'essais à caractère semi-industriel afin de caractériser l'utilisation de ces techniques dans des conditions de mesures sévères. <br />Les résultats obtenus au cours de ces différentes expériences montrent que l'outil d'imagerie quantitative et instantanée développé est opérationnel, répondant ainsi à un besoin d'informations quantitatives et spatialement résolues et complétant les possibilités offertes par les autres diagnostics optiques.
10

Tomographie par rayons X : correction des artefacts liés à la chaîne d'acquisition

Wils, Patricia 17 November 2011 (has links) (PDF)
L'imagerie cone-beam computed tomography (CBCT) est une méthodologie de contrôle non destructif permettant l'obtention d'images volumiques d'un objet. Le système d'acquisition se compose d'un tube à rayons X et d'un détecteur plan numérique. La recherche développée dans ce manuscrit se déroule dans le contexte industriel. L'objet est placé sur une platine de rotation et une séquence d'images 2D est acquise. Un algorithme de reconstruction procure des données volumiques de l'atténuation de l'objet. Ces informations permettent de réaliser une étude métrologique et de valider ou non la conformité de la pièce imagée. La qualité de l'image 3D est dégradée par différents artefacts inhérents à la plateforme d'acquisition. L'objectif de cette thèse est de mettre au point une méthode de correction adaptée à une plateforme de micro-tomographie par rayons X d'objets manufacturés poly-matériaux. Le premier chapitre décrit les bases de la physique et de l'algorithmie propres à la technique d'imagerie CBCT par rayons X ainsi que les différents artefacts nuisant à la qualité de l'image finale. Le travail présenté ici se concentre sur deux types d'artefacts en particulier: les rayonnements secondaires issus de l'objet et du détecteur et le durcissement de faisceau. Le second chapitre présente un état de l'art des méthodes visant à corriger le rayonnement secondaire. Afin de quantifier le rayonnement secondaire, un outil de simulation basé sur des techniques de Monte Carlo hybride est développé. Il permet de caractériser le système d'acquisition installé au laboratoire de façon réaliste. Le troisième chapitre détaille la mise en place et la validation de cet outil. Les calculs Monte Carlo étant particulièrement prohibitifs en terme de temps de calcul, des techniques d'optimisation et d'accélération sont décrites. Le comportement du détecteur est étudié avec attention et il s'avère qu'une représentation 2D suffit pour modéliser le rayonnement secondaire. Le modèle de simulation permet une reproduction fidèle des projections acquises avec le système réel. Enfin, le dernier chapitre présente la méthodologie de correction que nous proposons. Une première reconstruction bruitée de l'objet imagé est segmentée afin d'obtenir un modèle voxélisé en densités et en matériaux. L'environnement de simulation fournit alors les projections associées à ce volume. Le volume est corrigé de façon itérative. Des résultats de correction d'images tomographiques expérimentales sont présentés dans le cas d'un objet mono-matériaux et d'un objet poly-matériaux. Notre routine de correction réduit les artefacts de cupping et améliore la description du volume reconstruit.

Page generated in 0.4954 seconds