• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Validité du test cardiovasculaire à doubles marches, le CLW, à prédire les performances du test navette de 20 mètres et du test 12 minutes de Cooper chez les étudiants (es) âgés de 17 à 20 ans du Cégep de l’Abitibi-Témiscamingue / Validity of double steps test, CLW, to predict performence of 20 meters shuttle run and the 12 minutes run of Cooper on young students aged between 17 and 20 years olds of Cégep de l’Abitibi-Témiscamingue

Charles, Ugo January 2014 (has links)
Résumé : Le CLW (Chiasson, Lasnier et Whittom, 2005), un test à doubles marches sous-maximal (Step test) qui mesure le VO[indice inférieur 2max], requiert peu d’espace et exige 6 min 30 s à réaliser. Or, est-ce que le CLW peut remplacer un test de course comme le test navette de 20 mètres (Léger et Gadoury, 1989) ou le 12 minutes de Cooper (Cooper, 1968) lorsque l’espace n’est pas adéquat pour les effectuer? Soixante étudiants (es) du cégep de l’Abitibi-Témiscamingue âgés de 17 à 20 ans ont été sélectionnés à l’intérieur des cours d’éducation physique et ont accompli les trois tests physiques. L’objectif premier était de vérifier la capacité du CLW à prédire les résultats des tests de course navette de 20 mètres (Léger et Gadoury, 1989) et le 12 minutes de Cooper (Cooper, 1968). Deuxièmement, connaître si l’ajout d’un troisième palier au CLW était nécessaire pour une meilleure similarité entre les tests. Finalement, déterminer si une catégorisation des résultats permet une meilleure concordance. Cette étude n’a pas été en mesure de démontrer que le CLW est capable de prédire les performances des tests de course navette de 20 mètres et le 12 minutes de Cooper chez les étudiants du cégep de l’Abitibi-Témiscamingue. Par le fait même, l’ajout d’un troisième palier n’améliore pas de façon significative la capacité du CLW à prédire les performances des tests de course. Toutefois, le CLW s’avère être un meilleur prédicteur de la performance chez les femmes lorsque nous comparons les données brutes du VO[indice inférieur 2max]. Étant donné certaines faiblesses de cette étude, dont l’absence d’une mesure directe, nous recommandons des recherches futures pour comparer ces trois tests à une mesure directe du VO[indice inférieur 2max] pour déterminer lequel de ces tests est le plus approprié pour la clientèle générale du cégep de l’Abitibi-Témiscamingue. // Abstract : The CLW (Chiasson and Lasnier Whittom , 2005), a double steps test to measure VO[subscript 2max], has the advantage of being submaximal , to require little space and require only 6 min 30 s to achieve. Is the CLW can replace a running test as 20 meters shuttle test (Léger and Gadoury, 1989) or 12 minutes of Cooper (Cooper, 1968) when the space is not adequate to perform those running tests? Until now, no writing is not publicly available on the CLW and no one has yet measured the capacity of CLW to predict performance in the 20 meters shuttle test and test 12 minutes Cooper. Sixty students, divided by sex, selected within the physical education classes, have completed those physical tests. The objective of this research was to verify the capacity of CLW to predict the results of 20 meters shuttle run and the 12-minutes Cooper. In a second step, compared the results obtained to know if adding a third level to CLW is necessary for a better match between these tests. Finally, we grouped the values in class to determine if we can get a better result. This study did not demonstrate the CLW is able to predict the performance of 20 meters shuttle run test and 12 minutes of Cooper among our groups. Thereby, adding a third level does not improve significantly its ability to predict the performance of the run tests. However, the CLW proves to be a better predictor of performance in women when comparing raw data results obtained. Given some weaknesses of this study, as the a direct mesure to compare with, then we recommend that futures researches must compare these three tests with a direct measure of VO[subscript 2max] to determine which of these tests is most appropriate.
2

Built-In Self-Test of Flexible RF Transmitters Using Nonuniform Undersampling / Application de la technique de sous-échantillonnage non-uniforme au test intégré des émetteurs RF flexibles

Dogaru, Emanuel 06 March 2015 (has links)
Le secteur de communications sécurisés et portables connait une véritable révolution avec l’apparition des plateformes dites radios logiciels (Software Defined Radios, SDRs). Les performances exceptionnelles de ces systèmes sont les résultats d’une interaction assez complexe et souvent peu évidente entre le logiciel embarqué, le circuit de traitement numérique et les blocs mixtes analogiques/RF. Cette complexité limite la testabilité du produit fini. La méthodologie de test utilisée actuellement a atteint ses limites dues au cout élevé, le long temps de test et le bas degré de généralisation. De plus, les plateformes SDRs peuvent évoluer sur le terrain et elles vont supporter des standards et des scénarios qui n’ont pas été considérés pendant le la phase de conception. Donc, une stratégie de test sur le terrain (en ligne) n’est plus une caractéristique optionnelle mais une nécessité. Dans ce contexte, le but de notre recherche est d’inventer et développer une méthodologie de test capable de garantir le bon fonctionnement d’une plateforme SDR après la production et pendant sa vie. Notre objectif final est de réduire le coût du test en profitant de la reconfigurabilité de la plateforme. Pour les radios tactiques qui doivent être mises à jour sur le terrain sans équipement spécial, les stratégies Built-In Self-Test (BIST) sont, sans doute, la seule moyenne de garantir la conformité aux spécifications. Dans cette mémoire, nous introduisons une nouvelle architecture de test RF BIST qui utilise la technique de de sous-échantillonnage nonuniform à la sortie de l’émetteur (TX) d’une SDR afin d’évaluer la conformité de la masque spectrale. Notre solution s’appuie sur une implémentation autonome, est modulable et peut être appliquée pour le test sur le terrain avec des modifications minimes. Par rapport aux autres techniques de test analogiques/RF, cet approche ne dépends pas de la architecture du TX, ni d’un modèle ad-hoc, ce qui est idéale pour le test des SDRs. / The advent of increasingly powerful Integrated Circuits (IC) has led to the emergence of the Software Defined Radio (SDR) concept, which brought the sector of secured mobile communications into a new era. The outstanding performance of these systems results from optimal trade-offs among advanced analog/Radio Frequency (RF) circuitry, high-speed reconfigurable digital hardware and sophisticated real-time software. The inherent sophistication of such platforms poses a challenging problem for product testing. Currently deployed industrial test strategies face rising obstacles due to the costlier RF test equipment, longer test time and lack of flexibility. Moreover, an SDR platform is field-upgradeable, which means it will support standards and scenarii not considered during the design phase. Therefore, an in-field test strategy is not anymore 'a nice to have' feature but a mandatory requirement. In this context, our research aims to invent and develop a new test methodology able to guarantee the correct functioning of the SDR platform post-fabrication and over its operational lifetime. The overall aim of our efforts is to reduce post-manufacture test cost of SDR transceivers by leveraging the reconfigurability of the platform.For tactical radio units that must be field-upgradeable without specialized equipment, Built-in Self-Test (BIST) schemes are arguably the only way to ensure continued compliance to specifications. In this study we introduce a novel RF BIST architecture which uses Periodically Nonuniform Sampling (PNS2) of the transmitter (TX) output to evaluate compliance to spectral mask specifications. Our solution supports a stand-alone implementation, is scalable across a wide set of complex specifications and can be easily applied for in-field testing with small added hardware. Compared to existing analog/RF test techniques, this approach is not limited to a given TX architecture and does not rely on an ad-hoc TX model, which makes it ideal for SDR testing.
3

Built-In Self-Test of Flexible RF Transmitters Using Nonuniform Undersampling / Application de la technique de sous-échantillonnage non-uniforme au test intégré des émetteurs RF flexibles

Dogaru, Emanuel 06 March 2015 (has links)
Le secteur de communications sécurisés et portables connait une véritable révolution avec l’apparition des plateformes dites radios logiciels (Software Defined Radios, SDRs). Les performances exceptionnelles de ces systèmes sont les résultats d’une interaction assez complexe et souvent peu évidente entre le logiciel embarqué, le circuit de traitement numérique et les blocs mixtes analogiques/RF. Cette complexité limite la testabilité du produit fini. La méthodologie de test utilisée actuellement a atteint ses limites dues au cout élevé, le long temps de test et le bas degré de généralisation. De plus, les plateformes SDRs peuvent évoluer sur le terrain et elles vont supporter des standards et des scénarios qui n’ont pas été considérés pendant le la phase de conception. Donc, une stratégie de test sur le terrain (en ligne) n’est plus une caractéristique optionnelle mais une nécessité. Dans ce contexte, le but de notre recherche est d’inventer et développer une méthodologie de test capable de garantir le bon fonctionnement d’une plateforme SDR après la production et pendant sa vie. Notre objectif final est de réduire le coût du test en profitant de la reconfigurabilité de la plateforme. Pour les radios tactiques qui doivent être mises à jour sur le terrain sans équipement spécial, les stratégies Built-In Self-Test (BIST) sont, sans doute, la seule moyenne de garantir la conformité aux spécifications. Dans cette mémoire, nous introduisons une nouvelle architecture de test RF BIST qui utilise la technique de de sous-échantillonnage nonuniform à la sortie de l’émetteur (TX) d’une SDR afin d’évaluer la conformité de la masque spectrale. Notre solution s’appuie sur une implémentation autonome, est modulable et peut être appliquée pour le test sur le terrain avec des modifications minimes. Par rapport aux autres techniques de test analogiques/RF, cet approche ne dépends pas de la architecture du TX, ni d’un modèle ad-hoc, ce qui est idéale pour le test des SDRs. / The advent of increasingly powerful Integrated Circuits (IC) has led to the emergence of the Software Defined Radio (SDR) concept, which brought the sector of secured mobile communications into a new era. The outstanding performance of these systems results from optimal trade-offs among advanced analog/Radio Frequency (RF) circuitry, high-speed reconfigurable digital hardware and sophisticated real-time software. The inherent sophistication of such platforms poses a challenging problem for product testing. Currently deployed industrial test strategies face rising obstacles due to the costlier RF test equipment, longer test time and lack of flexibility. Moreover, an SDR platform is field-upgradeable, which means it will support standards and scenarii not considered during the design phase. Therefore, an in-field test strategy is not anymore 'a nice to have' feature but a mandatory requirement. In this context, our research aims to invent and develop a new test methodology able to guarantee the correct functioning of the SDR platform post-fabrication and over its operational lifetime. The overall aim of our efforts is to reduce post-manufacture test cost of SDR transceivers by leveraging the reconfigurability of the platform.For tactical radio units that must be field-upgradeable without specialized equipment, Built-in Self-Test (BIST) schemes are arguably the only way to ensure continued compliance to specifications. In this study we introduce a novel RF BIST architecture which uses Periodically Nonuniform Sampling (PNS2) of the transmitter (TX) output to evaluate compliance to spectral mask specifications. Our solution supports a stand-alone implementation, is scalable across a wide set of complex specifications and can be easily applied for in-field testing with small added hardware. Compared to existing analog/RF test techniques, this approach is not limited to a given TX architecture and does not rely on an ad-hoc TX model, which makes it ideal for SDR testing.

Page generated in 0.0797 seconds