• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Espectroscopia entre 10 e 4000 centímetros pot. Aplicação aos modos vibracionais da sodalita natural brasileira / The influence of capture centers on the dielectric relaxation of KI:M++ crystals

Zilio, Sergio Carlos 20 April 1983 (has links)
Encontrou-se que a relaxação dielétrica dos dipolos impureza-vacância em KI dopado com pequenas quantidades de KCl é extremamente diferente da relaxação dielétrica na matriz KI não contendo íons Cl-. Os novos picos de relaxação, atribuídos à presença do Cl- na vizinhança imediata do íon divalente, tem um tempo de relaxação 103 vezes menor que o normal na temperatura ambiente. Foi proposto um modelo para o aprisionamento dos íons divalentes pelo Cl- e estudado a influência dos raios atômicos do divalente e do anion estranho neste processo de aprisionamento. / The dielectric relaxation due to I-V dipoles in KI doped with small amounts of KCl was found to be strongly different than in KI crystals not containing Cl-ions. The new relaxation peak attributed to the presence of the Cl- in the close neighborhood of the divalent ion has a relax¬ation time 103 greater than the normal one. A model for the trapping of the divalent ions by the Cl- is proposed. The influence of atomic radius of the divalent and the impurity anion is discussed.
2

Influência de centros de captura na relaxação dielétrica de cristais de Ki:M++. / The influence of capture centers on the dielectric relaxation of Ki:M ++.

Zilio, Sergio Carlos 16 August 1976 (has links)
Encontrou-se que a relaxação dielétrica dos dipolos impureza-vacância em KI dopado com pequenas quantidades de KCl é extremamente diferente da relaxação dielétrica na matriz KI não contendo íons Cl&#8254.Os novos picos de relaxação, atribuídos à presença do Cl&#8254 na vizinhança imediata do íon divalente, tem um tempo de relaxação 103 vezes menor que o normal na temperatura ambiente.Foi proposto um modelo para o aprisionamento dos íons divalentes pelo Cl&#8254 e estudado a influência dos raios atômicos do divalente e do anion estranho neste processo de aprisionamento. / The dielectric relaxation due to I-V dipoles in KI doped with small amounts of KCl was found to be strongly different than in KI crystals not containing Cl&#8254.The new relaxation peak attributed to the presence of the Cl&#8254 in the close neighborhood of the divalent ion has a relax¬ation time 103 greater than the normal one.A model for the trapping of the divalent ions by the Cl&#8254 is proposed. The influence of atomic radius of the divalent and the impurity anion is discussed.
3

Influência de centros de captura na relaxação dielétrica de cristais de Ki:M++. / The influence of capture centers on the dielectric relaxation of Ki:M ++.

Sergio Carlos Zilio 16 August 1976 (has links)
Encontrou-se que a relaxação dielétrica dos dipolos impureza-vacância em KI dopado com pequenas quantidades de KCl é extremamente diferente da relaxação dielétrica na matriz KI não contendo íons Cl&#8254.Os novos picos de relaxação, atribuídos à presença do Cl&#8254 na vizinhança imediata do íon divalente, tem um tempo de relaxação 103 vezes menor que o normal na temperatura ambiente.Foi proposto um modelo para o aprisionamento dos íons divalentes pelo Cl&#8254 e estudado a influência dos raios atômicos do divalente e do anion estranho neste processo de aprisionamento. / The dielectric relaxation due to I-V dipoles in KI doped with small amounts of KCl was found to be strongly different than in KI crystals not containing Cl&#8254.The new relaxation peak attributed to the presence of the Cl&#8254 in the close neighborhood of the divalent ion has a relax¬ation time 103 greater than the normal one.A model for the trapping of the divalent ions by the Cl&#8254 is proposed. The influence of atomic radius of the divalent and the impurity anion is discussed.
4

Espectroscopia entre 10 e 4000 centímetros pot. Aplicação aos modos vibracionais da sodalita natural brasileira / The influence of capture centers on the dielectric relaxation of KI:M++ crystals

Sergio Carlos Zilio 20 April 1983 (has links)
Encontrou-se que a relaxação dielétrica dos dipolos impureza-vacância em KI dopado com pequenas quantidades de KCl é extremamente diferente da relaxação dielétrica na matriz KI não contendo íons Cl-. Os novos picos de relaxação, atribuídos à presença do Cl- na vizinhança imediata do íon divalente, tem um tempo de relaxação 103 vezes menor que o normal na temperatura ambiente. Foi proposto um modelo para o aprisionamento dos íons divalentes pelo Cl- e estudado a influência dos raios atômicos do divalente e do anion estranho neste processo de aprisionamento. / The dielectric relaxation due to I-V dipoles in KI doped with small amounts of KCl was found to be strongly different than in KI crystals not containing Cl-ions. The new relaxation peak attributed to the presence of the Cl- in the close neighborhood of the divalent ion has a relax¬ation time 103 greater than the normal one. A model for the trapping of the divalent ions by the Cl- is proposed. The influence of atomic radius of the divalent and the impurity anion is discussed.
5

Técnica de correntes termo-estimulada em circuito aberto. Aplicação ao estudo do transporte de cargas no polímero PETP / Thermo stimulated technique in open circuit. Application to the investigation of charge transport in PETP polymer

Malmonge, José Antonio 13 July 1988 (has links)
Foi construída uma nova versão de um sistema para medidas de correntes termo-estimuladas em circuito aberto (DTE). Mostrou-se que no Teflon FEP, carregado com corona negativa, os ruídos que aparecem nas curvas de DTE , que são devidos a micro rupturas elétricas na amostra, causam uma variação de potencial considerável na mesma. Verificou-se também que a corrente anômala originada pelo deslocamento de cargas na camada de ar entre a amostra e a placa sensora pode perturbar as medidas de DTE com amostras virgens carregadas positivamente. A inversão de polaridade da corrente nas medidas de DTE na região próxima a temperatura ambiente, foi explicado como sendo devido a variação da capacitância da amostra em função da temperatura. Medidas de DTE, realizadas com o polímero PETP (Mylar), mostraram que o processo de transporte que dá origem ao pico de corrente acima de 100 C é devido a uma condutividade intrínseca originária da geração de portadores em centros neutros de ionização. Essa geração possui uma dependência com o campo elétrico do tipo Poole-Frenkel e a mobilidade dos portadores livres, depende do volume livre o qual tem valor maior que o de equilíbrio abaixo da temperatura da transição vítrea / A new version of thermo stimulated current setup (DTE) in open circuit was built. It was shown in measurements electric noise is present in the DTE curve in Tefon FEP negatively charged which is due to micro electric breakdown in the sample. It was also found that the electric current in air gap between the sample surface and the sensor plate can disturb DTE measurements performed in positively charged samples. The polarity inversion on the DTE curves at room temperature range is due to the capacitance variation with the temperature. DTE measurements on PETP (Mylar) showed that the charge transport gives a current peak at 100 C due to an intrinsic conductivity generated by carriers from ionization centers. This process is described by a Poole-Frenkel
6

Técnica de correntes termo-estimulada em circuito aberto. Aplicação ao estudo do transporte de cargas no polímero PETP / Thermo stimulated technique in open circuit. Application to the investigation of charge transport in PETP polymer

José Antonio Malmonge 13 July 1988 (has links)
Foi construída uma nova versão de um sistema para medidas de correntes termo-estimuladas em circuito aberto (DTE). Mostrou-se que no Teflon FEP, carregado com corona negativa, os ruídos que aparecem nas curvas de DTE , que são devidos a micro rupturas elétricas na amostra, causam uma variação de potencial considerável na mesma. Verificou-se também que a corrente anômala originada pelo deslocamento de cargas na camada de ar entre a amostra e a placa sensora pode perturbar as medidas de DTE com amostras virgens carregadas positivamente. A inversão de polaridade da corrente nas medidas de DTE na região próxima a temperatura ambiente, foi explicado como sendo devido a variação da capacitância da amostra em função da temperatura. Medidas de DTE, realizadas com o polímero PETP (Mylar), mostraram que o processo de transporte que dá origem ao pico de corrente acima de 100 C é devido a uma condutividade intrínseca originária da geração de portadores em centros neutros de ionização. Essa geração possui uma dependência com o campo elétrico do tipo Poole-Frenkel e a mobilidade dos portadores livres, depende do volume livre o qual tem valor maior que o de equilíbrio abaixo da temperatura da transição vítrea / A new version of thermo stimulated current setup (DTE) in open circuit was built. It was shown in measurements electric noise is present in the DTE curve in Tefon FEP negatively charged which is due to micro electric breakdown in the sample. It was also found that the electric current in air gap between the sample surface and the sensor plate can disturb DTE measurements performed in positively charged samples. The polarity inversion on the DTE curves at room temperature range is due to the capacitance variation with the temperature. DTE measurements on PETP (Mylar) showed that the charge transport gives a current peak at 100 C due to an intrinsic conductivity generated by carriers from ionization centers. This process is described by a Poole-Frenkel

Page generated in 0.11 seconds