• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Thermométries ultrasonore et infrarouge pour le contrôle de la protection myocardique / Ultrasonic and infrared thermometries for the control of myocardial protection

Engrand, Céline H. 30 November 2016 (has links)
Le succès de la chirurgie cardiaque dépend essentiellement de la préservation des tissus durant l'opération. Afin d'optimiser cette dernière, une protection myocardique est appliquée à travers la perfusion d'une cardioplégie hypothermique lui permettant de tolérer l'ischémie provoquée par l'absence de vascularisation. Malgré ces progrès techniques et les connaissances accumulées, la chirurgie cardiaque reste une chirurgie à risque dont les complications sont parfois de nature inconnue. Il n'existe pourtant pas de suivi opérationnel de la protection myocardique et les seules indications disponibles pour le chirurgien sont l'arrêt contractile du cœur en début de cardioplégie ou l'apparition de fibrillations cardiaques dénonçant une inefficacité à long terme de la cardioplégie. Parmi les paramètres de mesure pouvant contribuer à la surveillance du myocarde sous cardioplégie, le suivi du changement de température induit par celle-ci pourrait devenir un indicateur pertinent. L'objectif de ce travail de thèse est donc de mettre en place un dispositif de suivi thermique du cœur permettant d'évaluer concrètement la diffusion et l'efficacité de perfusion cardioplégique durant la chirurgie cardiovasculaire.Parmi les méthodes de suivi thermique non invasives implantables en salle d'opération, la thermométrie par ultrasons (TUS) et la thermographie par infrarouges (TIR) ont retenu notre attention. Dans un premier temps, une méthode directe de thermométrie par ultrasons basée sur le principe "d'écho tracking" est expérimentée via un capteur ultrasonore $2,25 MHz mono-élément sur une gamme de température de 10 à 30°C. Cependant la caractérisation du muscle cardiaque par ultrasons et les expérimentations menées en laboratoire ont mis en avant la complexité du milieu nécessitant une calibration préalable, difficile à mettre en place en conditions opératoires. La technique présente tout de même une précision de mesure satisfaisante pour une variation de température inférieure à 10°C. Un modèle d'ajustement est alors proposé afin d'identifier la tendance de réchauffement interne du cœur à partir de la température de surface mesurable via une caméra thermique à infrarouge et par l'estimation volumique du milieu par ultrasons. Le modèle est validé dans un premier temps par simulation par éléments finis et dans un second temps durant des expérimentations sur fantômes et cœur in-vitro.Au final, le dispositif multi-physique TIR et TUS est expérimenté sur modèle in-vivo lors d'opérations, durant lesquelles des sessions de refroidissement par cardioplégie hypothermique sont effectuées. L'étude se conclut sur des premiers résultats de suivi thermique satisfaisants où les températures surfaciques acquises par TIR et l'estimation de l'épaisseur des parois ventriculaires par ultrasons permettent d'obtenir efficacement la tendance de réchauffement du myocarde. Le dispositif multi-physique a également démontré la possibilité d'appliquer une calibration directe de la thermométrie ultrasonore. Cette étude de faisabilité a démontré la possibilité d'un monitoring thermique du cœur de manière non invasive et applicable en temps réel. Ce dispositif pourrait être, après adaptation spécifique, implémenté durant les interventions cardio-vasculaire et fournir un indicateur précieux aux chirurgiens quant à l'efficacité de la protection myocardique. / The success of cardiac surgery essentially depends on tissue preservation. To optimize this latter, a myocardial protection is applied thanks to a hypothermic cardioplegia that confers a marked protective effect to the heart under ischemia. Despite these technical developments, cardiac surgery still presents risks and complications are sometimes of an unknown nature. However, no operational real-time monitoring of myocardial tissue exists. Among the metrics that could be analyzed, the temperature change measurement may be a relevant indicator. The objective of the present thesis is therefore to establish a thermal monitoring system of the heart in a way to evaluate the quality of the cardioplegia perfusion during cardiovascular surgery.Among the non-invasive thermal monitoring methods implantable in the operating room, the ultrasonic thermometry and infrared thermography caught our attention. In the first stages of the study, a direct method of ultrasonic thermometry based on the echo tracking is performed on in-vitro samples with 2.25 MHz ultrasonic sensor in a temperature range between 10 to 30°C. The ultrasonic characterization of the heart muscle and the laboratory experiments brought to the forth an environmental complexity requiring prior calibration that may be difficult to implement in operational conditions. However, the technique has a satisfactory measurement accuracy for temperature variations of less than 10°C.An adjustment model is then proposed to identify the in-depth warming trend of the heart thanks to the surface temperature measurement performed by thermal infrared camera and the medium thickness estimated by ultrasound. The model is validated by finite element simulations and experiments realized on ghosts and in-vitro heart samples.Finally, the device is experimented on in-vivo animal models while hypothermic cardioplegia were conducted. Conclusive results were obtained on the heart thermal monitoring. In particular, the surface temperatures acquired by infrared thermography and the thickness estimation of the ventricular walls by ultrasound allowed an estimation of the myocardial-warming trend.This feasibility study has demonstrated the possibility of heart thermal monitoring, noninvasively and appropriate in real time. After specific adaptation, this device could be implemented during cardiovascular interventions and provide a valuable indicator for the surgeons about the efficacy of myocardial protection.
2

Etude d'une méthode ultrasonore d'estimation des températures locales du sodium liquide en sortie coeur RNR-Na / Study of an ultrasonic method of estimating local temperatures of liquid sodium at the output of the core of SFRs

Massacret, Nicolas 10 January 2014 (has links)
Dans le cadre des recherches menées sur les SFR (Sodium cooled Fast Reactor), le CEA souhaite développer une instrumentation innovante et spécifique à ces réacteurs. Le travail présenté concerne la mesure par ultrasons, de la température du sodium à la sortie des têtes des assemblages du coeur du réacteur. Cette instrumentation implique la propagation d'ultrasons dans du sodium liquide, thermiquement inhomogène et turbulent. Le milieu provoque des déviations du faisceau acoustique qu'il faut prévoir et quantifier pour envisager d'employer les ultrasons comme moyen de mesure dans un coeur de réacteur SFR.Pour cela un code nommé AcRaLiS (Acoustic Ray in Liquid Sodium) a été implémenté. Une étude thermo-hydraulique précise du sodium a tout d'abord été menée afin de proposer une description adaptée du milieu et de choisir le modèle de propagation acoustique adéquat. Puis une implémentation a été réalisée afin de permettre la simulation rapide de la propagation d'ondes de plusieurs mégahertz dans ce milieu particulier. Ce code prévoit les déviations et l'évolution de l'intensité du faisceau acoustique. Deux expériences ont ensuite été conçues et réalisées pour vérifier ce code. La première, nommée UPSilon, innove en remplaçant le sodium par de l'huile de silicone afin d'avoir une inhomogénéité thermique stable pendant l'expérience. Elle permet de déterminer la validité du code AcRaLiS dans des inhomogénéités thermiques. La seconde, nommée IKHAR, permet d'étudier en eau l'influence de la turbulence sur la propagation d'ondes, en exploitant les instabilités de Kelvin-Helmholtz. Les conclusions et les perspectives sont présentées en élargissant à d'autres domaines d'application. / In the frame of research on Sodium cooled Fast nuclear Reactor (SFR), CEA aims to develop an innovative instrumentation, specific to these reactors. The present work relates to the measurement of the sodium temperature at the outlet of the assemblies of the reactor's core by an ultrasonic method. This instrumentation involves the propagation of ultrasonic waves in liquid sodium, thermally inhomogeneous and turbulent. Environment causes deviations of the acoustic beam that must be understood to predict and quantify to consider ultrasound as a measure means in a core of SFR reactor. To determine the magnitude of these influences, a code named AcRaLiS (Acoustic Ray in Liquid Sodium) has been implemented. In a first step, a thermal-hydraulic study specific to the medium, was conducted to provide an adequate description of the environment and choose a suitable acoustic propagation model. Then an implementation has been performed to allow rapid simulations of the wave propagation at several megahertz in this particular environment. This code provides ultrasounds deviations and changes in beam intensity.Two experiments were designed and conducted to verify the code. The first, named UPSilon innovates by replacing sodium by silicone oil in order to have a stable thermal inhomogeneity during the experiment. It allows to determine the validity of the code AcRaLiS with thermal inhomogeneities. The second, called IKHAR allows to study the influence of water turbulence on the propagation of waves, using the Kelvin-Helmholtz instabilities. Conclusions and perspectives are presented, including perspectives for other application domains.

Page generated in 0.0671 seconds